N655UA
Service difficulty reports · 383
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N655UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N655UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2010020100401Heat Exchanger · crackedHEAVY AIR LEAK NOISE COMING FROM RT PACK. FOUND DURING TOWING, UPON VISUAL INSP FOUND SECONDARY HEAT EXCHANGER WITH A CRACK 7 INCHES LONG. R & R SECONDARY HEAT EXCHANGER. OP CKS NORMAL.SDR UALA2010012800343Shutoff Valve · malfunctioned1 SPAR VALVE LIGHT REMAINED ILLUMINTATED WITH FUEL CONTROL SWITCH SELECTED (CUTOFF, RICH, RUN). EICAS MSG (L,R) SPAR VALVE DISPLAYED. POS(01=L,02=R) AFTER LT ENGINE START SPAR VALVE AND FUEL VALVE LIGHT ILLUMINATED ENGINE SHUTDOWN. REPLACED NR1 ENG FUEL SHUSDR UALA2010011100125Bleed Valve · faultyAPU BLEED BLEED AIR ON WITH SWITCH OFF. APU VALVE LOCK CLOSED. SUSPECT THE APU BLEED SWITCH AT FAULT. REPLACED VALVE, OPS TEST NORMAL.SDR UALA2009122904041Line · leakingLEFT ENG BLEED OFF TRIP OFF ON DECENT. ACP BITE CK PRSOV HIT. REPLACED PRSOV. DURING ENG RUN, FOUND NR 2 ENG SOMETIMES FOLLOWS THROTTLES UP PAST 60 PSI OTHER TIMES AFTER BLEED SHIFT, NR 2 KEEPS ON DECREASING TO 8 PSI THEN BLEED GOES OFF. ALSO FOUND AT IDLE HASDR UALA2009112003628Actuator · faultyONE SPAR VALVE LIGHT REMAINED ILLUMINATED WITH FUEL CONTROL SWITCH SELECTED (CUTOFF, RICH, RUN). EICAS MSG (L, R) SPAR VALVE DISPLAYED. REPLACED ENG FUEL SHUTOFF VALVE & OPS CHECKS NORMAL.SDR UALA2009110903508Circuit Card · faultyLT WING SLIDE ECAM INTERMITTENTLY CAME ON. CHECKED OVER WING SLIDE SENSORS S198 PINS C-5, D-5 RESISTANCE READ 13.5, S218 PINS A-5, B-5 RESISTANCE READ 18.6. REPLACED CARD DRIVER, OPS CHECKS NORMAL. NO EICAS MSGS WERE NOTED. NO LIGHTS AT LT OVERWING SLIDE.SDR UALA2009110403420Sensor · out of adjustLT WING SLIDE EICAS MSG, RTFL. FOUND SENSOR S218 ON LT OVERWING PACK DOOR LOOSE BUT APPEARED TO BE WITHIN TOLERANCE (0.10) BUT WITH MOVEMENT CAUSED EICAS MSG. REMOVED SHIM FROM SENSOR S218 FOR TROUBLESHOOTING, NO HELP. WILL NEED TO RE-GAP S-218. AFTER REMOVISDR UALA2009101403222Duct · malfunctionedCABIN PRESSURE LOSS, RTFL. REPLACED EQ COOLING OVERBOARD EXHAUST VALVE. NEW VALVE BAD FROM STOCK, ROBBED VALVE FROM KNOWN GOOD AC STILL FAILED, NEEDS MORE T-S. FOUND DUCT CONNECTED TO EXHAUST VALVE CRUSHED. REPLACED DUCT. A/C OKAY FOR SERVICE.SDR UALA2009092903061Pump · faultyTHE C HYD DEM PUMP EICAS MSG DURING GEAR FLAP RETRACTION. REPLACED ADP PRESSURE SWITCH S28, NO HELP. FOUND CTR DEM PUMP ADP OVERSPEED. REPLACED ADP. NO LEAKS AND OPERATIONAL TEST PASSED.SDR UALA2009091102871Pump · malfunctionedCTR HYD PRESS LIGHT ON, EICAS "C HYD DEM PUMP" MSSG W/ SWITCH IN "ON" POS. AS PER VERBAL WITH ARRIVING CREW. EICAS C-HYD DEM PUMP DURING GEAR AND FLAP RETRACTION. LIGHT EXTINGUISHED AFTER RETRACTION. CHECKED ADP. OPS NORMAL ON GROUND. REMOVED ADP, AND HUSDR UALA2009090802839Warning System · false activationTHE 'LT ENG FUEL FILTER' EICAS, FLT DIVERTED. AFTER LANDING CAPT REPORTED ENG RAN NORMAL WITH NO PARAMETER SHIFTS. NORMAL SHUTDOWN AT GATE. NO CONTAMINATION FOUND AT FUEL SYS, RPL FUEL FILTER & FUEL FILTER BYPASS SWITCH. LEAK CHECKED, NO LEAKS FOUND. ALSOSDR UALA2009081102459Generator · failedAPU GEN ISSUE. APU INOP ELECTRICAL. UNABLE TO LOAD GENERATOR. CREW COMMENTS: APU GEN TRIPPED OFF. WILL NOT RESET. REPLACED GENERATOR. ALL OPS AND CHECKS OKAY.SDR UALA2009072302177Pump · failedTHE C ADP INOP IN AUTO OR MAN MODE. CREW COMMENTS: AFTER PUSHBACK & AFTER FLAP ACTIVATION GOT EICAS C HYD DEM PUMP. SWITCH TO ON-NO CHANGE. AREA AROUND ADP REQUIRES CLEAN-UP. APPEARS THAT PAINT HAS DEGRADED DUE TO HYD LEAK. REQUIRES CLEAN-UP. REPLACED CSDR UALA2009070701960Skate Angle · leakingNR 2 ENGINE I/B SKATE ANGLE LEAKING FUEL AT AFT TANK SEAM. FOUND LEAK UNDERNEATH OF SKATE ANGLE AFT SEAM PYLON AREA. REMOVED TAIL SAIL PANELS. SCRAPPED SMALL AREA AT SEAM. CONFIRMED FUEL LEAK FROM SEAM UNDER SKATE ANGLE. SCRAPED SEAM AS REQUIRED CLEANED ASDR UALA2009060301598Battery · faultyRECEIVED "MAIN BATTERY CHARGER" STATUS MSG. REPLACED MAIN BATTERY & CHARGER. CHECKS OKAY.SDR UALA2009051801392Oil Filter · defectiveNR 1 ENGINE OIL FILTER MESSAGE DISPLAYED. MESSAGE REMAINED WHEN THRUST REDUCED AND AFTER ENGINE SHUTDOWN. REPLACED OIL FILTER. CHK C-D'S OK, RAN ENG, NO LEAKS NOTED. PROBABLE PART IS OIL FILTER DIFF PRESSURE SWITCH, REPLACED SWITCH.SDR UALA2009042401190Transmitter · faultyLEFT ENGINE OIL QTY INDICATION READS INACCURATE HIGH. REPLACED OIL QUANTITY TRANSMITTER, 1.5 MIN IDLE RUN, NO LEAKS NOTED.SDR UALA2009042401187Sensor · out of adjustLEFT OVERWING SLIDE EICAS MESSAGE. RTFL. ACCOMPLISHED BITE OF PSEU AND GOT CARDS (005,007 AND 004) FAULT. ALSO GOT S218 SENSOR & TARGET FAULT. FOUND DOOR WARNING SENSOR OUT OF LIMITS. DEACTIVATED OVERWING SLIDES. ADJUSTED TO CORRECT GAP & REACTIVATED SYSSDR UALA2009031000562Unknown · odorFLT ATTENDANTS REPORT SMOKE SMELL IN MID CABIN. ACCOMPLISHED VISUAL AND SMELL TEST FOR 30 MINUTES. NO ODOR DETECTED. RAN PACKS AND UTILITY BUSSES FOR 30 MINUTES, CHECKS GOOD. SUSPECT GLYCOL RESIDUE.SDR UALA2009021900563Exciter · unknownREPLACED NR 2 EXCITER BOX. OPS CHECKS OK. REPLACED NR 2 EXCITER BOX P/N 50T847 - SHIELD; P/N AA134S1 - IGNITER PLUG; P/N 48174 - CABLE; P/N 44958 - CABLE & P/N 10-621630-1 - EXCITER.SDR UALA2009021900562Unknown · odorFLIGHT ATTENDANTS REPORT, SMOKE SMELL IN MID CABIN. ACCOMPLISHED VISUAL AND SMELL TEST FOR 30 MINUTES. NO ODOR DETECTED. RAN PACKS AND UTILITY BUSSES FOR 30 MINUTES, CHECKS GOOD. SUSPECT GLYCOL RESIDUE.SDR UALA2009021300481Light · faultyFWD EEL LIGHT BARS L900 AND L908 DO NOT FULLY ILLUMINATE. REMOVED BAD LIGHT BARS AND REPLACED WITH SERVICEABLE BARS L900 AND L908 AT FWD LT CLOSET AND CENTER GALLEY AREA, AND OPS CHECK GOOD.SDR UALA2009021300480Light · faultyEEL LIGHT BAR L901 NOT FULLY ILLUMINATED. REPLACED LIGHT BAR L901 AT FWD RT GALLEY AND REPLACED BATTERY AT CHARGER M730, OPS CHECK GOOD.SDR UALA2009021300479Light · faultyEEL LIGHT BARS L905 AND L897 DO NOT FULLY ILLUMINATE. REMOVED BAD LIGHT AND INSTALLED SERVICEABLE LIGHT BARS L905 AND L897 AT MID LT LAV AND CENTER PARTITION AND OPS CHECK GOOD.SDR UALA2009021300478Light · faultyEEL LIGHT BAR L896 PARTIALLY ILLUMINATES. REPLACED LIGHT BAR L896 AT RT MID LAV-CLOSET AND OPS CHECK GOOD.SDR UALA2009021300477Light · faultyEEL LIGHT BAR L910 PARTIALLY ILLUMINATES. REMOVED BAD EEL LIGHT BAR AND INSTALLED SERVICEABLE LIGHT BAR L910 AT AFT LT LAV, AND OPS CHECK GOOD.SDR UALA2009021300476Light · faultyEEL LIGHT BAR L985 AND L904 PARTIALLY ILLUMINATES. REMOVED BAD LIGHT BARS AND REPLACES WITH SERVICEABLE LIGHT BARS L985 AND L904 AT RT AFT LAV AND CENTER AFT GALLEY AREA AND OPS CHECK GOOD.SDR UALA2009011300150Disc · damagedLOW BOTTLE. DAMAGE TO BURST DISC CAUSING A SLOW LEAK. R&R BURST DISC.SDR UALA2009010500053Switch · failedFUEL CONFIG EICAS AND LIGHT. RT TANK 2.6 LOW. DURING BALANCE PROCEDURE THE RT AFT FUEL PUMP EICAS NOT DISPLAYED. NEEDS SWITCH ASSY. REMOVED AND REPLACED AFT PRESSURE SWITCH. OPS CKS NORMAL.SDR UALA2008122206946Actuator · faultyAILERON LOCKOUT EICAS AND OVERHEAD LIGHT CAME ON AROUND 300 KTS. CREW ADVISED BOTH O/B AILERONS APPEAR TO BE LOCKED OUT IN CRUISE. RT AIL LOCKOUT MODULE FAULT BALL DISPLAYED, RT AIL LOCKOUT ACTUATOR REPLACED.SDR UALA2008121906923Idg · inoperativeL GEN OFF EICAS & L GEN CONT OFF LIGHT ILLUMINATED. COMPLIED WITH MEL - NR 1 ENG GENERATOR DISCONNECTED. GENERATOR HAS UNDER VOLTAGE PER BPCU MSG. SWAPPED GCU'S, NO HELP. REPLACED LEFT IDG. GROUND RAN, OPS CHECK NORMAL.SDR UALA2008121506875Bleed Valve · excess playNR 1 ENGINE 2.5 BLEED VALVE HAS EXCESSIVE PLY ON THE RIGHT SIDE OF THE RING. ALSO FOUND METAL SHAVINGS IN RING AREA AROUND 3 O`CLOCK POS. REPLACED ESN 724666 WITH ESN 727987 IN POS 01.SDR UALA2008120806783Starter · inoperativeNR 2 ENGINE NO START. REPLACED STARTER.SDR UALA2008120406752Engine · hot startNR 1 ENG HOT START, MAX EGT 768. (EXCEEDS 535). SEE EICAS ENG EXCD FOR MAX EGT AND DURATION. CREW COMMENTS: NO FUEL INITIATED DURING START. INSPECTED ENGINE INLET AND EXHAUST. RAN ENGINE IN GATE START WAS NORMAL. CREW STATED IT HAD EGT INDICATION ON PUSHSDR 2008UALA06293Idg · faultyLEFT IDG RISE SHOWS 0 TEMP, RIGHT IDG SHOWS 17. CLEANED AND SECURED L IDG CONNECTORS. INSTALLED NEW GCU WITH NO HELP. REINSTALLED OLD GCU. REPLACED NR 1 ENGINE IDG. IDG OP CHECKS NORMAL.
SDR 2008UALA05755Light · disconnectedEMERGENCY EXIT LIGHTING STRIP DISCONNECTED NEAR SEATS 10E. LIGHT STRIP FOUND DISCONNECTED. SECURED LOOSE LIGHT STRIP. OP CHECKS OKAY.SDR UALA2008111305731Fmu · faultyNR 2 ENG, TURBINE CASE COOLING ACTUATOR IS LEAKING FUEL AT A RATE OF 30 DROPS PER MINUTE. FOUND CHUNKS OF RUBBER COVERING 10 PERCENT OF STRAINER. PERHAPS O-RING MATERIAL. NO METAL FOUND. CLEANED AND REINSTALLED STRAINER. COMPLETED INSP OF STRAINER INSTALLSDR 2008UALA05731Actuator · leakingNR 2 ENG, TURBINE CASE COOLING ACTUATOR IS LEAKING FUEL AT A RATE OF 30 DROPS PER MINUTE.SDR UALA2008111304388Circuit Breaker · faultyLEFT GEN DID NOT STAY ONLINE AFTER ENG START. REPLACED GCU, NO HELP. REPLACED IDG, NO HELP. REPLACED GENERATOR CONTROL BREAKER C901 UP TO IDG PHASE CABLES. SYSTEM TEST GOOD.SDR 2008UALA04388Generator · malfunctionedLEFT GEN DID NOT STAY ONLINE AFTER ENG START.
SDR 2008UALA04168Light · looseEEL STRIP LOOSE ON FLOOR BY MID LAV. *S/D* FOUND LOOSE LIGHT ASSEMBLY. SECURED LIGHT ASSEMBLY, OP CHECK GOOD. AC OK FOR SERVICE.SDR 2008UALA03781Actuator · faultyLT PACK TEMP MSG IN CRUISE. *S/D* SUSPECT RAM AIR DOOR ACTUATOR. REPLACED ACTUATOR, OP CHECK GOOD. AC OK FOR SERVICE.
SDR 2008UALA03761Wire · looseCABIN EEL INOP AFT GALLEY. *S/D* FOUND LOOSE CONNECTION. SECURED CONNECTION, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03760Wire · disconnectedEMERGENCY EXIT LIGHT INOP RT MID LAV. *S/D* FOUND LOOSE CONNECTION. SECURED CONNECTION, OP CHECK GOOD. AC OK FOR SERVICE.SDR 2008UALA03759Light · inoperativeEXTERIOR EEL LT INOP AFT RT SIDE SLIDE LT. *S/D* FOUND FAULTY LAMP. REPLACED LAMP, OP CHECK GOOD. AC OK FOR SERVICE.SDR 2008UALA03585Heat Exchanger · faultyCREW COMMENTS: GOT HOT IN CABIN 74-79-81, HAVE TO OPERATE RT PACK IN STBY C TO HAVE A COMFORTABLE TEMP. *S/D* SUSPECT FAULTY HEAT EXCHANGER. REPLACED LEFT HEAT EXCHANGER IAW MM 21-51-02, OP CHECKED GOOD. AC OK FOR SERVICE.SDR UALA2008111303552Structure · damagedDAMAGE TO LWR CHORD IN LT AC BAY ABOVE PLENUM. MAJOR REPAIR ACCOMPLISHED. AFTER HEAT TREAT AND CAD PLATING INSTALLED ANGLES, STRAP AND CHORD SECTION. LOWER CHORD REPAIRED PER UA-EVA-71685.SDR 2008UALA03552Structure · damagedDAMAGE TO LWR CHORD IN LT AC BAY ABOVE PLENUM.SDR 2008UALA02992Light · inoperativeEMERGENCY ESCAPE LIGHT STRIP IN FRONT OF RT MID LAV IS INOP. FOUND LIGHT ASSEMBLY BROKEN. REPAIRED LIGHT ASSEMBLY, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03013Cover · unsecureBUSINESS EMERGENCY LIGHTING COMING OUT AGAIN. FOUND LIGHT ASSEMBLY LOOSE RE-ATTACHED EMERGENCY LIGHT STRIP COVER. AC OK FOR SERVICE.
Back to N655UA