N657UA
Service difficulty reports · 337
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N657UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N657UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2019032900487Wire Harness · chafedNR 1 ENG FUEL FLOW FLUCTUATED CONSIDERABLY AFTER APPLYING TO TH RUST INSP WIRING FOUND MULTIPLE WIRES ON HARNESS CHAFFED. CONNECTOR W AS SECURED CHAFFED TO BACK SHELL OF CONNECTOR D11000. RETERMINATED W3510-034-20 AND W3510-302R-20 TO CONNECTOR D11000 AS SWPMSDR CALA2017120804350Light · shortedL/H AFT EMERGENY PATH LIGHT ASSEMBLY AT SEAT 21DEF IS SHORTED. RELAMPED 21DEF EMERGENCY PATH LIGHT ASSY-OPS CKS NORMALSDR CALA2017091503190Connector · damagedEMERGENCY LIGHT ROW 27AB CONNECTOR ON CEILING PANEL DAMAGED. INSTALLED A NEW CONNECTOR IAW SWP 20-61-00, AND WDM 33-51-13. OP CHECKED OK.SDR CALA2017091503189Lamp · inoperativeEMERGENCY LIGHT AT RIGHT AFT LOWER FUSELEAGE IS INOPERATIVE. REPLACED THE LAMP, TESTED OK.SDR CALA2017091503188Lamp · inoperativeEMERGENCY LIGHT AT LEFT CEILING ROW 24 WAS INOPERATIVE. REPLACED THE LAMP. OPS CHECKED OK.SDR CALA2017081102610Lamp · inoperativeRIGHT SIDE EXTERNAL EMERGENCY LIGHT JUST FORWARD OF AFT CARGO DOOR IS INOPERATIVE. REPLACED THE LAMP, OPS CHECKED OK.SDR CALA2017052101510Unknown · odorELECTRICAL ODOR AND SHORT-LIVED THUMPING SOUND EMANATING FROM THE AFT GALLEY FLOOR. AMM 25-33-00. OPS CK NORMAL OK TO CONTINUE.SDR CALA2017010900040Rotary Actuator · trippedON FINAL APPROACH TRAILING EDGE DISAGREE. EMERGENCY DECLARED. FIM PROCEDURE 27-90-30 PERFORMED FOR TE FLAP DESAGREE, FDE TE DISAGREE INTERMITTENT INACTIVE FOUND, FSEU BITE PERFORMED IAW A MM 27-51-00-735 NO FAULT CONFIRMED, FLAP ASSY GENERAL VISUAL INSPECTIONSDR CALA2016112800979Gcu · faultyHEAVY SMOKE ODOR IN THE FLIGHT DECK ONLY, IMMEDIATELY FOLLOWED BY LOSS OF LEFT GEN AND BOTH UTILITY BUSES. FIRE DEPT REPORTED SEEING SMOKE COMING OUT OF E&E COMPT. NO EICAS MESSAGES REPORTED. APU STARTED AND DID NOT PICK LEFT BUS. SUSPECT A SHORT IN E&E. FOUNDSDR CALA2016101100750Flap System · false activationTE FLAP DISAGREE MESSAGE. PERFORMED FLAP/SLAT ELEX UNIT, EMERGENCY DECLARED. BITE CHECKED IAW FIM 27-51 FT 809. NO EXISTING FAULTS DETECTED. EXTENDED FLAP/SLATS SEVERAL TIMES AND FAUL T DID NOT REPEAT. OK TO CONTINUE.SDR CALA2016081500544Power Supply · failedCABIN CENTER SEAT ROW 21 - 23, FLOOR PROXIMITY EMERGENCY LIGHT FOUND DIM. POWER SUPPLY M1209 REPLACED AND TEST CARRIED OUT NORMAL IAW AMM 33-51-07, AND 33-51-10.SDR CALA2016080900509Battery Pack · dischargedCABIN SEAT 4D TO 6D FLOOR PROXIMITY EMERGENCY LIGHT FOUND DIM. CABIN EMER LT BATTERY PACK. REPLACED AND SEAT 4D TO 6D FLOOR PROXIMITY EMER LT TEST CARRIED OUT NORMAL AS PER AMM 33-51-07.SDR CALA2016072700453Floor Support · corrodedBS 1518 LBL 1, FLOOR SUPPORT FOUND CORRODED BS 1518 LBL 1. FLOOR SUPPORT REPAIRED IAW SRM 53-00-51 REPAIR 2 FIG 201SDR CALA2016072700452Skin · crackedREF NR LP 6201534, 410-0058, B767-54-3-6017 NR 1 PYLON INBD PANEL 436BR CUTOUT SKIN FOUND CRACKED NR 1 PYLON INBD PANEL 436BR CUTOUT SKIN. REPAIRED IAW SRM 54-53-01, REPAIR 7, FIG 201.SDR CALA2016012895059Battery · dischargedSEAT MOUNTED EMER EXIT LIGHTS INOPERATIVE FROM SEAT ROW 35 RT - 39 RT. REPLACED BATTERY AT M99804 IAW MM 33-51-07 PG 201. OPERATIONS CHECKED NORMAL.SDR CALA2015122494915Light · arcedON FINAL APPROACH LIGHT BURNING ODOR NOTED. SMOKE ALARM IN LAVATORY 2R WENT OFF, NO APPARENT FIRE. CAPTAIN STATES MID RT LAVATORY IS WHERE SMOKE DETECTOR ACTIVATED. INSPECTED LAVATORY WATER HEATER, LAVATORY ASSEMBLY, ASSEMBLY ELEC COMPONENTS FOR ANY SIGN OFSDR CALA2014102192534Light · defectiveLEFT AFT OVERWING EMER PATH LIGHT DIM. REPLACED LIGHT & LENS ASSEMBLY IAW BSWPM 20 - 30-11 & AMM 33-51-06. OPERATIONS CHECKED GOOD IAW AMM 33-51-06.SDR CALA2014101692450Frame · crackedAFT PIT STATION 1197 AT APPROX RBL 32, FRAME WEB IS CRACKED. REMOVED DAMAGE AT FASTENER HOLE LOCATION. FABRICATED A REPAIR DOUBLER & FILLER IAW REO G18376 REV A & INSTALLED IAW ECRA 5310-06276.SDR CALA2014100792383Structure · corrodedCORROSION FOUND ON J CHORD AFT PIT FLOOR STRUCTURE STATION 1197 RBL 3 - 45. REMOVED DAMAGE BY REPLACING AFT PIT FLOOR J CHORD PN 146T1060 2 IAW SRM 51-40-02.SDR CALA2014092992336Doubler · corrodedAFT LT EXTERNAL FUSELAGE SKIN REPAIR DOUBLER AT BS 1832.9 TO 1847.9 IS GOUGED. FOUND EXISTING DOUBLER TO BE OUT OF LIMITS. REMOVED REPAIR DOUBLER, FABRICATED A NEW DOUBLER & FILLER. INSTALLED IAW SRM 53-80-01.SDR CALA2014092992326Doubler · gougedAFT RT EXTERNAL FUSELAGE SKIN DOUBLER BS 1832.9 TO 1847 AFT OF RT HORIZONTAL STAB CUT OUT IS GOUGED. REMOVED SKIN DOUBLER, FABRICATED, DRILLED & LOCATED A NEW DOUBLER IAW SRM 53-80-01 REPAIR 3 FIG 201 DETAIL V SHEET 6 OF 7. INSTALLED IAW SRM 53-80-01 & 51-40SDR CALA2014092292267Structure · corrodedAFT CARGO STATION 1197+110, LBL 10 - RBL 36 UPPER J CHORD HAS CORROSION UNDER NUTPLATES. UPPER J CHORD CORRODED BEYOND SRM LIMITS. REMOVED IAW SRM 51-40-02. RECEIVED NEW UPPER J CHORD PN 146T1061-1. LOCATED & DRILLED IAW SRM 51-40-05 & DWG 146T1228 REV A. SDR CALA2014090892072Floorbeam · mechanic errorFLOORBEAM SINGLE FLANGE REPAIR AT BS 764, RBL 34 - 55 REQUIRES EVALUATION FOR PROPER NUMBER OF STRUCTURAL FASTENERS ON THE UPPER STRAP. EVALUATED PREVIOUS REPAIR STRAP & FOUND IMPROPER NUMBER OF FASTENER HOLES INSTALLED. R & R & FABRICATED A NEW REPAIR STRAPSDR CALA2014090892071Floorbeam · corrodedMAIN CABIN FLOOR STRUCTURE AT BS 847 & LBL 58, TRANSVERSE FLOORBEAM CORRODED, MID LAVATORY AREA. MATERIAL REMAINING AFTER CORROSION BLEND OUT EXCEEDED SRM 53-50-51. REMOVED DAMAGED FLOORBEAM SECTION, FABRICATED A NEW UPPER CHORD SECTION & INSTALLED IAW SRM 53SDR CALA2014080191576Light · inoperativeEMERGENCY ESCAPE PATH LIGHT L905 INOPERATIVE. EMER LIGHT REPLACED AT MID CROSS AISLE AT FWD COACH BULKHEAD L905 IAW MM 33-51-10.SDR CALA2014050690976Pin · shearedLEFT OVERWING SLIDE DOOR FWD ALIGNMENT PIN IS SHEARED OFF. REMOVED SHEARED PIN, PIN IS AOG.SDR CALA2014042190889Structure · corroded3 EACH AREAS OF CORROSION FOUND AT STATION 1540 IN CTR OF BELLY NEXT TO BELLY DRAIN, JUST FWD & INBD OF OUTFLOW. ACCOMPLISHED REPAIRS AS NECESSARY IAW 5360-01370 & APPLICABLE SRM.SDR CALA2014041790843Stringer · corrodedCORROSION DAMAGE ON STRINGER 39R AT STATION 1540. CUT STRINGER TO REMOVED CORROSION DAMAGESDR CALA2014031990643Smoke Detector · inoperativeRIGHT AFT LAVATORY SMOKE DETECTOR HAS NO POWER LIGHT. REPLACED SMOKE DETECTOR.SDR CALA2014021090356Warning System · activatedON SHORT FINAL CTR HYD DEM EICAS CAME ON WITH GEAR SELECTED DOWN & FLAPS 20 SELECTED.SDR CALA2013121693752Hydraulic Line · leakingNR 1 ENG WHILE PERFORMING ENGINE RUN FOUND A HEAVY HYD FLUID LEAKING OUT OF LARGE DRAIN MAST. FOUND FAR AFT HYD SUPPLY LINE IN J BOX LOOSE, TIGHTENED LINE. LEAKED CHECKED GOOD & OPERATIONS CHECKED GOOD.SDR CALA2013112693284Wire · looseDOOR 2L ARCING, RTFL. DUE TO LOOSE WIRING FOUND ON 115VAC SERVICE OUTLET AT DR 2L, REPLACED THE OUTLET.SDR CALA2013100491758Isolation Valve · faultyWHILE DOING SERVICE CHECK FOUND LT ISOLATION VALVE LIGHT ON. R & R LT ISOLATION VALVE. OPERATIONS CHECKED GOOD.SDR CALA2013100491733Coax · damagedSATCOM INOPERATIVE BIT TEST SHOW STBD BSU FAIL LOW GAIN ONLY CIRCUIT BREAKER PANEL P11 H7, H9 PULLED & SAFE TIED. REMOVED & REPLACED STBD BSU IAW AMM 23-25-17, NO HELP. CHECKED FWD & AFT COAX CABLES FROM STBD BSU FOUND CENTER PIN PULLED THRU CONNECTOR AT POS SDR CALA2013080990317Light · inoperativeSEAT 14B EMERGENCY LIGHT INOPERATIVE. EMERGENCY LIGHT ASSY REPLACED AND TESTED OK.SDR CALA2013080990316Lens · crackedSEAT 32A, EMERGENCY LIGHT LENS CRACKED. EMERGENCY LIGHT ASSY REPLACED AND TESTED IAW AMM 33-51-001, TEST OK.SDR CALA2013080990315Light · inoperativeSEAT 39J, EMERGENCY LIGHT INOPERATIVE. EMERGENCY LIGHT ASSY REPLACED AND LIGHT TESTED.SDR CALA2013080990314Light · faultySEAT 33A, EMERGENCY LIGHT DIM, EMERGENCY LIGHT ASSY REPLACED AND LIGHT TEST.SDR UALA2013071204900Microphone · defectiveNR 3 BOOM MICROPHONE IS DEFECTIVE. UNABLE TO TRANSMIT ON 1ST OBS MICROPHONE. REPLACED MIC AT 1ST OBSERVERS SEAT AND TESTED.SDR UALA2013071104847Motor · faultyFLAPS WILL NOT MOVE ELECTRICALLY. LOWERED FLAPS IAW TASK 27-51-00-862-026, STEP 7 WITH HYDRAULICS. REPLACED ALTERNAT FLAP ELECTRIC MOTOR IAW AMM, UPPER MOUNT BOLT WITH GROUND WIRE IS WRONG PART. PERFORMED ECRA 2751-01436. PERFORMED SYS TEST IAW MM, NO FAULTSDR UALA2013070104561Transmitter · inaccurateLEFT HYD QUANT FLUCTUATING BETWEEN 0-98% CHECKED LEFT HYD QTY AT LT PYLON 95 PERCENT. OK TO CONTINUE. REPLACED LEFT HYD QTY TRANSMITTER IAW AMM. SERVICED TO FULL. REINSTALLED SIGNAL WIRE AT P37 PANEL. OPS CK NORMAL.SDR UALA2013061704180Circuit Card · faultyFWD EQIPMENT OVERHEAT ON EICAS AT 4000 FT AFTER TAKEOFF. REPLACED ECS FAN CONTROL CARD (M990) AND PERFORMED INSTALLATION TEST IAW MM 21-26-05-401. TEST OP CHECKED GOOD.SDR UALA2013061704178Circuit Card · malfunctionedLOW AIR FLOW AT E & E EXHAUST DUCT. REPLACED ECS FAN CONTROL CARD (M990) AND PERFORMED INSTALLATION TEST PER MM 21-26-05-401. TEST OP CHECKED GOOD.SDR UALA2013053003769O-Ring · leakingNR 1 ENGINE HYD LEAK. REPLACED BAD O-RING UNDER DPI FOR EDP PRESSURE CASE DRAIN FILTER MODULE IAW AMM.SDR UALA2013052303575Circuit Card · malfunctionedLOWER EICAS RT ENGINE OH LP 2 WILL NOT ERASE. REPLACED RT ENG AFLOTS CARD NR 2 M10274, NO STS MSGS, CONFIRM FIX AFTER ENG RUN REF MM ACCEL, DECEL TEST NR 4. STATUS MESSAGE "RT ENG OH LP 2" WAS STILL PRESENT BEFORE ENG RUN. WOULD NOT ERASE. ENG RUN WAS NOT SDR UALA2013052203533Motor · failedWHILE ACCOMPLISHING FLAP ALTERNATE POWER AND DRIVE TEST, IAW AMM 27-51-00. CIRCUIT BREAKER TRIPPED AT P6-4 D21 ALTERNATE FLAP MOTOR. SUSPECT MOTOR BAD. HEATS UP DURING START THEN BREAKER TRIPS. WIRE CHECKS, FOUND GOOD. T/E ALTERNATE MOTOR REMOVED. REPLACSDR UALA2013032001715Relay · malfunctionedLEFT THRUST REVERSER DID NOT DEPLOY ON LANDING. PERFORMED THRUST REVERSER OPS CHECK PER MM 78-31-00. LEFT ENG THRUST REVERSER OPERATES NORMAL, NO LEAKS. NO FAULTS ON TR RELAY MODULE. TROUBLESHOT SUSPECT LEFT THRUST REVERSER DEPLOY RELAY. REMOVED AND REPLASDR UALA2013031501590Pump · faultyCENTER HYD PUMP EICAS, RTFL REMOVED ADP CONTINUE WITH STEP 3 PAGE 408 OF MM. REPLACED ADP PER AMM. REPLACED HYD ELEC PUMP CTR 2 IAW MM. REMOVED NR 2 CNTR HYD ACMP. REPLACED CASE AND PRESSURE FILTERS AT FILTER MODULE. INSTALLED NR 2 CNTR HYD ELEC PUMP.SDR UALA2013031101450Actuator · faultyNEED TO REPLACE LEFT SIDE UPPER LCCA ACTUATOR. REPLACED LEFT HYD SYS LCCA AND ADJUSTED, OPS CHECKED GOOD.SDR UALA2013031101404Actuator · faultyFLT CONTROLS BIND A LITTLE BIT AFTER A LEFT TURN WHEN RETURNING THE CONTROL TO CENTER. REPLACED LY HYD SYS LCCA (FOUND INPUT OUTPUT ROD OUT OF ADJUSTMENT).
Back to N657UA