N657UA
Service difficulty reports · 337
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N657UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N657UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2013031101429Light · brokenSEAT 19B EMERGENCY LIGHT ON SIDE OF SEAT BROKEN. REPLACED LIGHT ASSY.SDR UALA2013031101428Light · brokenSEAT 21B EMERGENCY LIGHT ON SIDE OF SEAT BROKEN. REPLACED LIGHT ASSY.SDR UALA2013030701360Bearing · bindingDURING FLT CONTROL CHECK, FELT BINDING AND HANG UP WHEN FULL CONTROL WHEEL TO THE LEFT. REPLACED AILERON CAM FOLLOWER BEARING.SDR UALA2013030701357Toilet · cloggedAFT LEFT LAV OVERFLOWING. REMOVED DEBRIS AND UNCLOGGED LAV, OPS CHECKS OKAY.SDR UALA2013030501313Unknown · bindingCREW REPORTS DURING FLIGHT CONTROL CHECK TO THE LEFT, CONTROL WHEELS BINDS AND IS SLOW TO RETURN. WORKS NORMALLY TO RIGHT TURN. FLAPS DOWN OR UP. HYD PRESS AND INDICATIONS NORMAL. OPERATED ALL FLIGHT CONTROLS SEVERAL TIMES AND OPERATION FOUND SMOOTH AND NOSDR UALA2013021500895Stator Vane · damagedNR 1 ENGINE STATOR VANE AT 11:30-12:00 POS MISSING CHUNK OF LEADING EDGE REF AMM 72-33-02, DAMAGE STATOR MEASURES BETWEEN .250 AND .500 "AXIAL LENGTH" TAPED AS REQ OK FOR SERVICE.SDR UALA2013021500894Stator Vane · damagedNR 2 ENGINE STATOR VANE AT 11:30 POS MISSING CHUNK OF LEADING EDGE. REF AMM 72-33-02 DAMAGE STATOR MEASURES BETWEEN .250 AND.500"AXIAL LENGTH" WITHIN LIMITS TAPED AS REQ OK FOR SERVICE.SDR UALA2013021200849Apu · malfunctionedAT DEPARTURE, CREW REPORTS SMOKE IN CABIN. FIRE DEPARTMENT FOUND NO HOT SPOTS. TROUBLESHOOTING SMOKE IN CABIN CAUSED BY APU, NEED TO REPLACE RECIRCULATION FILTERS.SDR UALA2013020400675Screw · missingFOUR SCREWS MISSING FROMM ONE PANEL ON LEFT ENGINE PYLON INBD SIDE ABOVE ENGINE. INSTALLED MISSING SCREWS ON PANEL OK TO CONTINUE.SDR UALA2013020100605Sliding Window · out of adjustCAPTAIN'S WINDOW BINDING. ADJUSTED CAPTAIN'S SLIDING WINDOW, OPS CHECKED GOOD.SDR UALA2013012400419Computer · failedLEFT FCC FAILURE MESSAGE. REPLACED LEFT FCC, OPS CHECKED GOOD.SDR UALA2013012400418Autopilot Sys · inoperativeAUTOPILOT ASA DISPLAYED NO LAND 3 WITH F-D ON. LEFT AUTO PILOT INOPERATIVE.SDR UALA2013012200386Coupler · damagedLEFT HF INOPERATIVE. REPLACED NR 1 HF COUPLER REF AMM.SDR UALA2013010300020Coupler · weakHF TRANSMISSION AND RECEPTION ARE INOP, WEAK, GARBLED INTERMITTENT, ETC. AT ALL CREW STNS.(1 = L HF, 2 = R HF). HF1 WILL NOT TRANSMIT IN FLIGHT, TESTED OK ON THE GROUND. RECEPTION IS NORMAL PROG TEXT: ACCOMPLISH CHRONIC REVIEW, HAS HISTORY. TUNE CYCLE TAKSDR UALA2012122807450Unknown · odorCREW REPORTS OIL SMELL IN FWD CABIN AND FLT DECK AREA IN FLT. ODOR SEEMED TO DISSIPATE WITH LEFT PACK SELECTED OFF. NO SMOKE REPORTED. MAINT TEXT: PER SMOKE ODOR QUESTIONARE-PILOT REPORTS SWEET BURN SMELL MORE LIKE DE-ICING FLUID, OR HYD FLUID THAN FUEL. SDR UALA2012122707423Heat Exchanger · faultyRIGHT ENGINE EEC C1 STATUS MSG. REMOVED AIR OIL HEAT EXCHANGER AND VALVE ASSY IAW MM 79-21-09 UP TO AND INCLUDING STEP 2 F(5) OF PAGE 404. NEED TO COMPLETE FROM STEP 3 OF PAGE 404 TO END. COMPLETED INSTALLATION EXCEPT FOR 1 SET OF LINE CLAMPS AT 6 O'CLOCK PSDR UALA2012121907300Guard · missingCENTER ISOLATION VALVE SWITCH COVER MISSING. REPLACED SWITCH GUARD.SDR UALA2012121407207Skin · dentedFUSELAGE DENTED AT BS 379 S21-22L. INSTALLED DOUBLER REPAIR IAW ECRA 5311-01574 & REO-G15687, REV C.SDR UALA2012121207196Structure · crackedAFT FUSELAGE INTERNAL BULKHEAD T-CHORD CRACKED AT BS 1809.5, LBL 27. MAJOR REPAIR ACCOMPLISHED: FABRICATED A -1 AND -2 ANGLE WITH FILLER AND REPAIRED HORIZONTAL INNER CHORD PER SRM 53-80-08, REPAIR 10.SDR UALA2012111306542Guide Vane · missingNR 1 ENGINE INLET GUIDE VANE MISSING AT 6 O'CLOCK POSITION. FOUND 1 VANE MISSING AT THE 6 O'OCLOCK POSITION OK TO CONTINUE TO THE NEXT ENGINE SHOP VISIT REF MM-72-33-02.SDR UALA2012110906464Union · looseWHEEL WELL HYDRAULIC LEAKS. FOUND RIGHT WHEEL WELL FLAP SLAT SHUTOFF VALVE MODULE LEAKING AT THE FLAP PRESSURE PORT LINE UNION. FOUND UNIONS (5)(7) LOOSE, REPLACED PACKING ON BOTH UNIONS.SDR UALA2012110506302Eec · faultySTATUS MSGL ENGIINE EEC C1 MAINT TEXT: CREW REPORT PROBLEM ON LEFT ENGINE. BITE CHECK OF PIMU SHOWED EEC CHANNEL A AOC FD-BK FAIL AND EEC CAT 1 CH A AND B. REF PIMU MSG INDEX PAGE 600, MSG NUMBER 351-28 FOR TROUBLESHOOTING INFO DEACTIVATED VALVE IN OPEN POSSDR UALA2012110506306Oil Cooler · faultySTATUS MSGL ENG A-O VALVE. CREW REPORT PROBLEM ON LEFT ENGINE SEE DF647 BOTH ITEMS RELATED. BITE CHECK SHOWS EEC CH A AOC FD-BK FAIL. AOC VALVE DEACTIVATED PER MEL CARD 75040. VALVE IN OPEN POSITION AND PLUG DISCONNECTED AND SAFTIED. DF PLACARD PLACED ON SDR UALA2012110506305Pressure Switch · faultyRIGHT ENGINE ELEC HYD DEMAND PUMP DID NOT COME ON IN AUTO OK IN ON POSITION. REF SSM 29-00-03 SHT 1 JUMPERED SWITCH S31 PINS 3 AND 2 AND PUMP OPERATES NORMALLY IN AUTO. REQUIRES SWITCH S31 PCN 481-0076 AND SEAL 750-5644. PUMP AND SYSTEM PRESSURE LT OPS NORMSDR UALA2012110506307Connector · damagedRT ENG HYD PUMP LOW PRESSURE LIGHT OUT WHEN RT ELEC DEMAND PUMP IS IN THE AUTO OR ON POSITION, PUMP OPERATION NORMAL. JUMPERED SWITCH S31 PINS 2 AND 3 AND LT OPERATED NORMAL. SUSPECT S31 PCN 481-0076 AND SEAL 750-5644 AT FAULT. PUMP OPERATED NORMALLY AND SYSSDR UALA2012103106273Wire Harness · faultyNEED IDLE RUN TO VERIFY EGT OPS DUE TO W-6 HARNESS REPLACEMENT ON NR 2 ENGINE NR 2 ENGINE EGT, OPS CHECKS OK.SDR UALA2012101705937Generator · faultyAPU GENERATOR FIELD OFF. REPLACED APU GENERATOR PER MM.SDR UALA2012091905304Fill Port · strippedCREW O2 BOTTLE FILL PORT HAS STRIPPED THREADS. REPLACED FILL PORT.SDR UALA2012082904844Display · failedSATCOM STATUS ON LINK STATUS PAGE NO COMMS. SATCOM FAILURE DOES NOT DISPLAY SATCOM LOSS, EICAS MESSAGE SATCOM FAILED AFTER RESETTING CIRCUIT BREAKERS, ACCOMPLISH REVIEW. REPLACED SATCOM DISPLAY UNIT PER MM. GROUND CHECKED NORMAL.SDR UALA2012082804836Tray · warpedSATCOM INOPERATIVE. FOUND PLASTIC COOLING TRAY FOR SAT SDU WARPPED. REPLACED TRAY AND SEAL PCN 160-7204 REF IPC 25-71-41. RETURNED SDU, RFU HGA AND LGA ACCOMP TEST MM23-27-00. NO OTHER ISSUES NOTED. STILL REQUIRES VOICE TEST.SDR UALA2012082804841Structure · delaminatedLEFT ENGINE UPPER PYLON PANEL NOT FLUSH. PANEL FARING MID SECTION FIBERGLASS IS DELAMINATING ON THE FWD LEADING EDGE.SDR UALA2012082804840Cover · out of toleranceEMERGENCY LIGHT LENS ABOVE SEAT 2A DAMAGED. REPLACED LENS COVER.SDR UALA2012082904849Panel · damagedLT ENGINE UPPER PYLON PANEL NOT FLUSH. REPAIRED PANEL IAW ECRA 5430-01932 & SRM 54-53-70.SDR UALA2012082804825Engine · surgesECM DETECTED A 'SILENT' SURGE (NO CREW GRIPE) AT OR NEAR TOP OF DESCENT AT LOW POWER. THIS IS A RING CASE ENGINE. ACCOMPLISHED PRECAUTIONARY VISUAL CHECKS OF INLET AND EXHAUST AS WELL AS 2.5 BLEED AND 2.9 BLEED OPENINGS FOR DMG OR UNUSUAL MATERIAL. CONFIRM SDR UALA2012081604552Oxygen Mask · damagedFIRST OFFICERS O2 MASK PRESS TO TEST SWITCH STICKS ON AND O2 CONTINUES TO FLOW. REMOVED AND REPLACED FIRST OFFICER 02 MASK AS PER MM, OPS CHECKED GOOD.SDR UALA2012081304416Brake · fireNR 6 BRAKE FIRE REPORTED. ACCOMPLISHED INSPECTION AND CLEAN UP REF ECRA 0551-01032. NO DAMAGE NOTED. WHEEL ASSY'S 1 ,2, 5 AND 6 REPLACED REF AMM 32-45-01. BRAKE ASSY'S 5 AND 6 REPLACED.SDR UALA2012080904331Actuator · leakingDURING WALK AROUND, MECH NOTICED SIGN OF HYD LEAK FROM APU ACCESS DOOR. ON REMOVAL OF RUDDER ACCESS PANEL, FOUND LOWER PCA LEAKING AT THE ACTUATOR STATIC SEAL. THE LEAK IS APPROX 5 DROP PER MIN AND FOUND WITHIN LIMITS IAW AMM.SDR UALA2012072303980Amplifier · faultySATCOM SYSTEM INOPERATIVE. REPLACED SDU, OPS NORMAL. SATCOM STARTED WORKING AGAIN. REPLACED HIGH POWER AMPLIFIER (LGA).SDR UALA2012071603829Adc · failedADC MECHANICAL ISSUE, FLIGHT DIVERTED. CREW REPORTED AT FL370 FIRST OFFICER'S AIR DATA FLAGS IN VIEW AND THE RUDDER RATIO FAILED. SWITCHED TO FIRST OFFICERS ON STBY AND REGAINED AIR DATA INFO BUT THE RUDDER RATIO IS INOPERATIVE. RT ADC FAIL INDICATOR IN VISDR UALA2012070203511Rfu · inoperativeSATCOM INOPERATIVE. REPLACED RADIO FREQ UNIT.SDR UALA2012062903489Feeder Cable · shortedF/A SMELLED AN ELECTRICAL ODOR. NOTICED ODOR IN COCKPIT. FOUND PIGTAIL CONNECTOR AT LOCATION P53 LOOSE. REPLACED PIGTAIL.SDR UALA2012052402911Computer · faultyCENTER AUTOPILOT WILL NOT ENGAGE AND FIRST OFFICER FLT DIRECTOR BARS LOST WHEN CENTER FLT DIRECTOR ENGAGED. CENTER FCC INOPERATIVE. REPLACED CENTER FLIGHT CONTROL COMPUTER AS PER AMM. OPS CHECKED NORMAL. ALSO ACCOMPLISHED AUTOPILOT FLIGHT CONTROL TEST AS PSDR UALA2012052402910Computer · faultyAUTO THROTTLE DISCONNECTED ON SEVERAL OCCASIONS AND UNABLE TO STAY IN ARMED POSITION. REMAINDER OF FLT FLOWN WITH AUTOTHROTTLE OFF. REPLACED THRUST MANAGEMENT COMPUTER AS PER AMM. OPS CHECKED NORMAL.SDR UALA2012052102863Starter · faultedAFTER LANDING APU WOULD NOT START. THREE ATTEMPTS MAX EGT 777 N40. PRIOR START IN AIR WAS OK. CLEANED CONNECTORS AT IGV, FCU & FUEL FLOW DIVIDER & SOLENOID VALVE PER AMM & MM(S) RESPECTIVELY, CHECKED ALL MAG CD'S PER MM. FOUND CLEAN AND REPLACED APU STARTERSDR UALA2012041702312Stator Vane · damagedLEFT ENGINE, FOIL COMING OFF OF STATOR VANE. FOUND TAPE REPAIR COMING OFF OF LEADING EDGE. APPLIED TAPE. REPAIRED PER AMM.SDR UALA2012032601890Warning Light · illuminatedCREW ABORTED TAKEOFF AT 78 KTS DUE TO GENERATOR DRIVE LIGHT AND ASSOCATED EICAS MESSAGE. CREW REPORT 6 BRAKES WENT TO "6" THEN DOWN TO '4' BY END OF TAXI BACK TO GATE. WEIGHT WAS 383K, OAT 9DEG C, 1500' PRESS ALT. CONDITIONAL INSPECTION CARRIED OUT SATISFACTSDR UALA2012030901532Hydraulic Line · leakingUNABLE TO RETRACT L MLG, RTFL L MLG EXTENSION RETRACTION LINE LEAKING HYDRAULIC FLUID. REPLACED LINE LEAK CHECK OK WITH LANDING GEAR DOWN AND LOCKED GEAR PINNED AND HANDLE CYCLED. NEED TO JACK AND SWING LANDING GEAR AND CHECK FOR LEAKS IN LT MLG. ACCOMPLISHSDR UALA2012030701486Seal · leakingDURING WALKAROUND, FOUND HYD LEAKING DOWN BOTH SIDES OF TAIL COMPT. CYCLED RUDDER, FOUND UPPR RUDDER PCA LEAKING OUT OF FWD SHAFT SEAL. REMOVED UPPER RUDDER PCA. SHOP REPAIRED ACTUATOR BY REPLACING FWD SHAFT SEALS. WORKING INSTALL.SDR UALA2012022001035Union · leakingNR 1 ENG HYDRAULIC LEAK FROM DRAIN. ACCOMPLISHED AMM 71-71-00 P61, HYDRAULIC LEAK IN LT PYLON VIA STRUT DRAIN FROM CTR MOUNT DRAIN LINE. AREA CHECKED. FOUND UNION OF LT HYDRAULIC SYSTEM BETWEEN HYDRAULIC BAY AND PYLON LEAKING UNION RETIGHTENED AND LEAK CHESDR UALA2012020600724Pump · unknownNR 2 ENG FUEL PUMP REPLACEMENT.
Back to N657UA