N657UA
Service difficulty reports · 337
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N657UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N657UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2012020200659Rub Strip · looseNR 2 ENG RUB STRIP LOOSE LEADING EDGE OF REV COWL. INTERIM REPAIR ACCOMPLISHED PER ECRA 7111-01296. CLEANED AREA WITH SOLVENT PER GPM. APPLIED 3 LAYERS OF ALUMINUM TAPE 2524-2-0200 TO DISCREPANT AREAS. TAPE TO BE RE-INSPECTED EVERY 25 HOURS BEGINNING PTT 8SDR UALA2012012000436Computer · faultyR EICAS CMPTR STATUS. REPLACED RT EICAS COMPUTER. DOWNLOADED DATA PER MM. OPS CKS OKAY.SDR UALA2012011700356Actuator · faultyAILERON LOCK-OUT, RTFL. REPLACED RIGHT AND LEFT AILERON LOCKOUT ACTUATORS REF MM. LOCKOUT ACTUATOR AND MECHANISM TEST GOOD ON RIGHT AND LEFT SIDE.SDR UALA2011122107051Rub Strip · damagedNR 2 ENG O/B REV RUBSTRIP DAMAGED AND LOWER GUIDE CHANNEL WORN. REPLACED NR 2 ENG OTBRD REV RUBSTRIP. WAITING ON GUIDE CHANNEL ON AOG. REPLACED NR 2 ENGINE OUTBOARD GUIDE CHANNEL. GUIDE CHANNEL REQUIRES SEALANT APPLICATION.SDR UALA2011121906969Actuator · unknownAILERON LOCKED LIGHT ON AT HIGH SPEED. EICAS MESSAGE AILERON LOCKOUT DISPLAYED. OUTBD AILERONS INDICATED NORMAL - LOCKED OUT. ANNUNCIATION DISPLAYED FOR APPROX 10 SECONDS. ACCOMPLISHED FIM 27-11-00 F104 AND FAULT BALLS FOR 'ADC' ON RIGHT SAM AND 'R AIL LOCKSDR UALA2011110706006Fairing · missingNR 2 ENGINE MID SPAN SHROUD PANEL MISSING AT THE 8 O'CLOCK POSITION. INSTALLED MISSING INTERMEDIATE CASE FAIRING AT THE 8 O'CLOCK POSITION AS REQUIRED.SDR UALA2011110706011Fairing · damagedRIGHT WING INBD MID FLAP FAIRING DAMAGED FROM ENGINE MID SPAN SHROUD. DAMAGE MEASURES APPROX 4" IN LENGTH BY 2.5" IN WIDTH. DAMAGE GOES INTO THE HONEYCOMB. REMOVED MID FAIRING AND AFT FAIRING PER CDL 57H. MID FAIRING IN ORD MM SHEETMETAL SHOP FOR REPAIRS ASDR UALA2011110105925Tube · unknownNR 2 ENG DRAIN SYS TUBES ARE REMOVED FROM BOTH SIDES OF THE J-BOX AND SECTION OF RT SIDE. INSTALLED REMOVED TUBES.SDR UALA2011110105924Tube · obstructedNR 2 ENG DRAIN SYS TUBES FROM J-BOX BOTH LEFT AND RIGHT SIDES ARE OBSTRUCTED. REPLACED OBSTRUCTED TUBES.SDR UALA2011100305360Circuit Card · failedAFTER EXTERNAL POWER PULLED, "EICAS SCC" STATUS MESSAGE DISPLAYED AND WILL NOT ERASE. REPLACED EICAS SCC CARD PER MM.SDR UALA2011093005306Window · scratchedCAPTAIN'S NR 1 WINDOW IS SCRATCHED AND IS UNSERVICEABLE. VISIBILITY AFFECTED. REMOVED & INSTALLED WINDOW PER MM.SDR UALA2011092805246Lamp · inoperativeLEFT SQUIB TEST INOPERATIVE. RELAMPED AND CYCLED SWITCH, TEST NORMAL.SDR UALA2011090504779Pressure Switch · faultyAPU AUTOSHUTDOWN ON THE GROUND. REPLACED GEN OIL PRESSURE DIFFERENTIAL SWITCH PER MM, OPS NORMAL.SDR UALA2011082904585Unknown · odorELECTRICAL SMELL IN COCKPIT, FLIGHT DIVERTED. CREW REPORTED INTERMITTENT ELECTRICAL ODOR IN FLT DK. UTILITY BUSSES TURN OFF, ACFT DIVERT TO KEF. CK'D WINDOW HEAT TERMINALS FOR ANY DISCREPENCIES. NONE NOTED. CHECKED AND OPERATED RECIRC FANS FOR ANY DISCREPANCISDR UALA2011082204496Indicator · faultyFLT CREW REPORTING CAPT ADI BLANKING OUT, SWITCH TO ALT POSITION AND ADI ERRATIC. CAPT HSI ALL NORMAL. REPLACED THE CAPT'S EADI. INDICATIONS OK IN NORMAL AND ALTERNATE.SDR UALA2011080304052Heat Shield · failedNR 2 ENG OIL TANK HEAT SHIELD HAS DETERIORATED. REPLACED HEAT SHIELD.SDR UALA2011080103961Monitor · defectiveHYDRAULIC QUANTITY MONITOR UNIT NEEDS REPLACEMENT. REPLACED HYD QTY MONITOR.SDR UALA2011072703838Transmitter · failedLEFT HYD QTY INDICATION. REPLACED LT HYD QTY TRANSMITTER AMM 29-33-02. R AND E WORKING SIGNAL WIRE OF PTU. AFTER TRANSMITTER WAS REPLACED FOUND DIODE BLOCK R397 WITH BRUNDY TERMINAL JAMMED IN POSITION "C". WIRE TO POSITION "C" WAS BROKEN OFF AND TIED BACK. SDR UALA2011072803894Actuator · leakingNR 1 ENG VSV ACT HAS HISTORY OF FLUID LEAKS. NEED TO REPLACE THE VSV. REPLACED PER MM.SDR UALA2011072703855Warning Light · illuminatedLEFT HYD QTY INDICATION.SDR UALA2011080103960Filter · defectiveAPU AUTO SHUTDOWN THREE TIMES. APU INOP GENERATOR FILTER FAULT. REPLACED LUBE AND GENERATOR SCAVENGE OIL FILTER PER MM. ALSO SERVICED OIL, ADDED 1 QT. RAN APU AND LEAK CHECKED FILTER, NO LEAKS NOTED. RAN APU FOR 45 MIN. APU DID NOT AUTO SHUTDOWN.SDR UALA2011061702972Actuator · malfunctionedRUDDER OUT OF RIG 5 UNITS TO LEFT. WORKING RDR RIG. MEASURED RUDDER ACTUATOR INDEX POSITIONS FOR LEFT, CENTER AND RIGHT HYDRAULIC SYSTEMS. WHEN ALL SYSTEMS PRESSURIZED, INDEX IS SLIGHTLY TO THE LEFT OF PLATE. WHEN RIGHT SYSTEM PRESSURIZED ONLY, RUDDER TRAILISDR UALA2011061502945Heat Shield · deterioratedNR 2 ENG, OIL TANK HEAT SHIELD DETERIORATED. REPLACED NR 2 ENG OIL TANK HEATSHIELD.SDR UALA2011060302711Actuator · leakingL HYD LOW ON TAXI IN RF .63 INDICATED. FOUND CENTER RUDDER PCA LEAKING ACTUATOR. APPLIED SEALANT ON THE ACTUATOR. LEAKING 26 DROP PER MN WITHIN LIMITS AS PER AMM. OK TO CONTINUE. ACCESS PANEL 324JL.SDR UALA2011052002487Connector · unsecureRT PACK TRIPPED OFF AT GATE WHILE ON APU. SECURED CONNECTOR ON R PACK CPRSR OUT OVHT, OPS CHECKS OKAY. CLEANED CONNECTORS TO 490 AND 190 TEMP BULBS.SDR UALA2011050302171O-Ring · faultyNR 1 ENG OIL CONSUMPTION. INSPECTED ENG. FOUND OIL IN COWLINGS AND AROUND OIL PUMP AND CHIP DETECTORS. CLEANED OIL PUMP AND COATED EXTERIOR OF PUMP WITH DYE CHECK DEVELOPER. RAN ENG FOR 5 MIN. FOUND OIL LEAKING FROM OIL PUMP PARTING SURFACE WITH GEAR BOX. ALSOSDR UALA2011042602026Power Supply · inoperativeEMERGENCY ESC PATH LIGHTS L896 AND L910 ARE INOP. REPLACED PWR SUPPLIES M1553 AND 1561, PATH LIGHTS TEST OKAY.SDR UALA2011041801881Fseu · faultyFLAP-SLAT ELEC STATUS AND TRAILING ASYMMETRIC EICAS CAME ON WHILE SELECTING FLAPS 5. REPLACED FLAP SLAP ELEC UNIT AND ASYMMETRY RELAY K351 IN P36. RAN FLAPS AND SLAPS UP AND DOWN SEVERAL TIMES. ALSO ACCOMPLISHED VISUAL INSPECTION ON T/E FLAP TORQUE TUBES, ASDR UALA2011041501815Indicator · intermittentRT MAIN FUEL IND AND TOTAL INTERMITTENT. REPLACED COCKPIT FUEL QTY INDICATOR PER MM, OP CHECKS GOOD.SDR UALA2011040601654Actuator · out of adjustNR 2 ENGINE, STATIC LEAK UNDER ANGLE GEAR BOX. REMOVED AND REPLACED NR 5 FAN EXIT LINER IAW B767-300 AMM. REMOVED, REPLACED AND ADJUSTED THE 2.5 BLEED VALVE ACTUATOR IAW AMM AND CONNECTED ELECTRICAL CONNECTOR IAW AMM. OPS AND LEAK CHECKED GOOD.SDR UALA2011040401631Floor Support · corrodedRII-CANTED DECK STATION 955, LBL 12 IS CORRODED AT THE SEAM OUTBOARD OF THE RIB. MAJOR REPAIR ACCOMPLISHED: REPAIRED ALL CORROSION IN CANTED DECK AREA PER EA PD WITHOUT DEVIATION.SDR UALA2011031101173Connector · shortedPASSENGER AT 23H COMPLAINED OF BEING SHOCKED FROM THE AUDIO JACK. REPLACED AUDIO JACK AT 23H. 23H AUDIO OPS CHECK OK.SDR UALA2011022100894Valve · faultedNOSE STEERING CHECK. DUPLICATED AND ISOLATED STICKING STEERING TO METERING VALVE. REPLACED IAW AMM. STICKING ISSUE RESOLVED, BUT NEW VALFE FAILED OPS CK. INTERMITTENTLY HARD TO MAKE RT TURNS. SUSPECT BAD VLV FROM STOCK. REPLACED METERING VALVE AGAIN, NO HESDR UALA2011021000685Bottle · reads low2L DOOR SLIDE BOTTLE PRESSURE LOW. MED 2L SLIDE-RAFT CYLINDER PRESSURE GAUGE INDICATOR IS BELOW TEMP COMPENSATOR GREEN BAND. REPLACED DOOR 2L ESCAPE SLIDE PACK PER MM. INSPECTED DR 2L ESCAPE SLIDE INSTALLATION IAW MM.SDR UALA2011021000684Rod · wornENG NR 2 STARTER DUCT SUPPORT RODS WORN. REPLACED STARTER DUCT SUPPORT RODS.SDR UALA2011021000683Shroud · deterioratedENG NR 2 OIL TANK HEAT SHROUD DETERIORATED BEYOND LIMITS. REPLACED ENG NR 2 OIL TANK HEAT SHIELD.SDR UALA2011020700631Contact · dirtyRT EMERGENCY LIGHT AT T/E OF WING IS INOP. CLEANED CONTACT, OPS CHECKED GOOD.SDR UALA2010110804147Bulkhead · damagedLEFT SIDE COAX FEED THRU AT AFT PRESSURE BULKHEAD WAS LEAKING. SEALANT PR1458-B2 APPLIED TO AREA. NO FURTHER LEAKS.SDR UALA2010102203903Gcu · faultyBPCU FAULT APU GCU. REPLACED APU GCU, NO HELP. REPLACED APU GCU, NO HELP. WHEN LT GEN SELECTED APU GEN OFF LT ILLUM AND WOULD NOT COME BACK ON LINE. FREQS AND VOLTS GOOD. CYCLED CB FOR APU GEN CONT, NO HELP. REPLACED NR 1 ENG IDG AND BPCU. ALL AUTOMATIC SWISDR UALA2010102203902Gcu · faultyLT ENG GEN DID NOT COME ONLINE AUTOMATICALLY AFTER ENG START. HAD TO MANUALLY SELECT GEN ON. REPLACED GCU & BPU FOR NR1 ENG. OPS NORMAL.SDR UALA2010102103889Lens · brokenSEAT 37J, EMERGENCY LIGHT LENS BROKEN. REPLACED BROKEN EMERGENCY LIGHT LENS SEAT 37J.SDR UALA2010081202951Starter · faultyAFTER PUSHBACK CREW STATES NR 2 ENG DID NOT START IN IGNITION NR 2. N2 ROSE AND FELL BACK DOWN TO 5 PERCENT AND BOUNCED TO 8 PERCENT THEN BACK TO 6 PERCENT ON SECOND START. REPLACED NR 2 ENG STARTER AND START VALVE. RAN AND LEAK CHECKED ENG. ENG 2 OPS CKD NORSDR UALA2010080202777Wire · shortedEDP (ENGINE DRIVEN PUMP) HYD PWR. POS 2O1=L,O2=R) EDP HYD LOW PRESS LGT ILLUM. EICAS MSG DISPLAYED (LT,RT) HYD PRIM PUMP. EICAS MSG (LT,RT) HYD SYS MAINT (WAS, WAS NOT) DISPLAYED. CREW COMMENTS: PUMP AND SYS LO PSI LIGHT ON WITH R ELEC DEMAND SWITCH IN AUTO OSDR UALA2010072602681Transmitter · fluctuatesLT HYD QTY FLUCTUATING. REMOVED AND SECURED PTU SIGNAL WIRE AND WILL REQUIRE RECONNECTION IAW MEL ITEM. SYS IS INOP IAW MEL. QUANTITY VERIFIED. QTY NORMAL AND LOW PRESSURE LIGHT IS OPERATIVE. REPLACED LT HYD TRANSMITTER IAW MM. NO LEAKS NOTED. RECONNECTSDR UALA2010071202482Trim System · malfunctionedCREW REPORT: STAB TRIM EICAS ON TAXI OUT. CYCLED STAB TRIM CTRL C/B'S NO HELP, CYCLED FLT CTRL ELEC LT & RT 1&2 C/B'S FAULT CLEARS & STAYS OUT WHEN MOVING CAPT'S ELECT STAB TRIM SWITCHES. LIGHT & EICAS MSG RETURN WHEN F/O'S STAB TRIM SWITCHES ARE USED. STASDR UALA2010062102185Lamp · inoperativeLIGHT IN LAVATORY BUSINESS CLASS RT SIDE, LIGHT INOP. RELAMPED.SDR UALA2010060101896Line · leakingFOUND HEAVY HYD LEAK AT RT MLG DURING WALK AROUND. LEAK ISOLATED ON A BROKEN HYD FLEX LINE ON THE TOP RT OF MLG ON A FLEX HYD LINE PN 00624-AC127J-0300SS OR AS4624J-0300SS AT 3000 PSIG 275F AS4623*. FLEX HYD LINE REPLACED IAW AMM. LEAK CHECK PERFORMED, NO LEAKSDR UALA2010050601527Switch · defectiveRAT FAILED TO MANUALLY DEPLOY, DURING OPS CHECK RELATED TO KORRY SWITCH REPLACE COA 617952. REMOVED AND REPLACED RAT DEPLOY SWITCH S4 PER BACO SB. OPS CHECK OF RAT CHECKED GOOD, MANUAL DEPLOYMENT GOOD PER MM ON NON ROUTINE 21815.SDR UALA2010050601526Light · inoperativeEXTERIOR EMERGENCY LIGHT AT R-4 DOOR INOP. RELAMPED AFT RT EMERGENCY LIGHT AND OPS CHECK GOOD.SDR UALA2010050301491Actuator · crackedNR 7 SPOILER ACTUATOR SIDE HSG IS CRACKED. RUNNING LEAK AT 1 DROP IAW SECOND. ACTUATOR ON AOG NR Y1799. REPLACED NR 7 SPOILER ACTUATOR, OPS CHECKS GOOD.
Back to N657UA