N658UA
Service difficulty reports · 282
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N658UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N658UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011050202117Rudder · bindingCREW REPORTED BOTH RUDDER PEDAL HEAVY AND BINDING. FOUND NO BINDING WITH HYD PRESS ON AND OFF. ACCOMPLISHED RUDDER PEDAL FORCE CHECK PER MM. FOUND ALL FORCES WITHIN LIMITS. AIRCRAFT TO BE TEST FLOWN FOR FURTHER EVALUATION.SDR UALA2011041301792Rod · misinstalledWHEN CHANGING RT REAR TIRE ON RT MLG FOUND BRAKE ANTI ROTATION ROD ATTACH HARDWARE DAMAGED FROM BEING INSTALLED IMPROPERLY. REPLACED BRAKE ROD PER AMM.SDR UALA2011032901492Actuator · faultyTHE "AIL LOCK" LIGHT ON AT LOW SPEED. EICAS MSG AILERON LOCKOUT DISPLAYED. OUTBD AILERONS DID NOT INDICATE NORMAL -LOCKED OUT- BOTH. CREW COMMENTS: AILERON LOCKOUT DISPLAYED AT 220 KNOTS FL140. REPLACED ACT PER MM.SDR UALA2011032801466Slide · damagedAFT ALIGNMENT PIN FOR OVERWING SLIDE ON RT DOOR BROKEN OFF. REMOVED RT OVERWING SLIDE.SDR UALA2011031501243Wire · damagedSEAT EMERGENCY LIGHT AT SEAT 28B INOP. REPLACED SEAT MOUNTED EMERGENCY LIGHT LAMP ASSY AT 28AB, NO HELP. SUSPECT WIRING UNDER THE SEAT AT FAULT.SDR UALA2011031501242Power Supply · faultyEMERGENCY CEILING LIGHTS FROM SEATS 2AB- 8AB ARE INOP. REPLACED POWER SUPPLY, OPS CHECKED GOOD.SDR UALA2011031501241Battery Pack · inoperativeEMERGENCY EXIT SIGN ADJACENT TO MID GALLEY INOP. REPLACED BATTERY PACK. CHECKED, OKAY.SDR UALA2011031501240Battery Pack · faultySEAT EEL LIGHTS FROM SEATS 19AB-23AB INOP. REPLACED BATTERY PACK ASSY. CHECKED OKAY.SDR UALA2011031501239Light · missingEEL LIGHT AT SEAT 10K'S VIDEO PANEL MISSING. INSTALLED NEW LIGHT. CHECKS GOOD.SDR UALA2011030901146Pca · malfunctionedRIGHT AILERON FLOATS WITH RT HYD SYSTEM DEPRESSURIZED. REPLACED AND OPS CHECKED THE RT INBD AILERON PCA PER MM. OPS CHECKED GOOD.SDR UALA2011030201016Floorbeam · corrodedCORROSION ALONG FLOOR SUPPORT STA 853, LBL 75 FOUND TO BE BEYOND ALLOWABLE LIMITS. MAJOR REPAIR ACCOMPLISHED: REMOVED AND REPLACED T-CAP AND SPLICE ANGLES BTWN STA 853 AND 888 ALONG LBL 75 IAW SRM REPAIR 3. APPLIED TOPCOAT IAW SRM. APPLIED CIC IAW SRM ON PESDR UALA2011030201015Floorbeam · corrodedCORROSION ON FLOOR SUPPORT STA 853, LBL 54 BEYOND ALLOWABLE LIMITS IAW SRM. MAJOR REPAIR ACCOMPLISHED: REMOVED AND REPLACED TEE CAP BETWEEN STA 833 AND 920 IAW SRM REPAIR 3. APPLIED TOPCOAT IAW SRM, APPLIED CIC IAW SRM ON PEMCO NR 249N0 0154 BY TECH 600177, SDR UALA2011021600801O-Ring · tornON NR 2 ENG VISUAL INSP FOUND FUEL LEAK FROM FUEL OIL COOLER OUTLET HOSE LEAKING, FUEL ON FUEL PUMP INLET LINE CONNECTION. FOUND AND REPLACED TORN PACKING ON FUEL LINE, RAN NR 2 ENG AND NO LEAKS NOTED. FOUND FUEL LINE OK, JUST NEEDED TO REPLACE TORN O-RING.SDR UALA2011012500417Door · damagedDOOR 1R AFT BUSTLE HAS A 2" GASH THAT PROTRUDES INTO THE CORE. REPAIRED BUSTLE.SDR UALA2011012600430Relay · faulty1 SPAR VALVE LIGHT FAILED TO ILLUMINATE WITH FUEL CONTROL SWITCH SELECTED (CUTOFF, RICH, RUN). EICAS MESSAGE (LT, RT) SPAR VALVE DISPLAYED. POS(1=LT,2=RT). TESTED OK. DID NOT LIGHT WITH ENG START OR SHUTDOWN. VALVE OPS OK. INDICATOR INOPERATIVE. SLAVED NEWSDR UALA2011012500414Circuit Breaker · inoperativeCREW REPORTED NO POWER AT THE MID GALLEY. CREW ALSO REPORTED MID GALLEY C/B ON P11-3 PANEL GRID U06 TRIPPED. REPLACED C/B U6 ON P11-3 AND MID GALLEY ELCU M1241 IAW MM. POWERED UP ALL GALLEYS FOR 15 MIN. ALL GOOD.SDR UALA2011012500415Wire · inoperativeGALLEY PIGTAIL-ELECTRICAL INOPERATIVE AT AFT CTR-AFT GAL 425. THE WIRE IS OVRHEATING AND SPARKING, REPLACED PIGTAIL AT N52. OPS NORMAL.SDR UALA2011012100349Latch · bentFOUND RT OVER WING SLIDE FWD LINK-LATCH BENT AND FWD LATCH MISSING SPRING. REPLACED ALL DOOR LATCHES ON RT OFF WING ESCAPE SLIDE IAW MM. ACCOMPLISHED RII INSP OF THE RT WING SLIDE DOOR LATCHES IAW AMM.SDR UALA2010101503827Light · unsecureSEATS 24KJ, 25KJ AND 30AB HAVE EMERGENCY LIGHTS INOP. SECURED EMERGENCY LIGHTS, OPS CK OK.SDR UALA2010100403653Actuator · leakingNR 2 ENG VARIABLE STATOR VANE ACTUATOR HAS FUEL STREAMING FROM DRAIN. REPLACED NR 2 ENG VSV ACTUATOR IAW MM.SDR UALA2010092003491Actuator · faulty"AIL LOCK" LT ON AT HIGH SPEED. EICAS MESSAGE "AILERON LOCKOUT" DISPLAYED. OTBD AILERONS INDICATED MOVEMENT, UNLOCKED, BOTH. LIGHT CAME ON FOR 5 MIN AND THEN WENT OUT. PERFORMED SAM BITE. NO FAULT BALL ON LT AND RT SAM. NO AILERON LOCKOUT STATUS MESSAGE ON SDR UALA2010070102347Light · inoperativeSEAT 8J EMERGENCY AISLE LIGHT INOP DUE TO OTTOMAN SEAT BROKEN. SEAT 8J EMERGENCY LIGHT REMOVED WIRES PROTECTED AND STOWED, NIL TIME TO REPAIR. NEED EEL HARNESS ASSY. REPLACED LIGHT ASSY.SDR UALA2010052101725Controller · malfunctionedNO APU GEN AFTER GROUND START. APU FIELD LIGHT ON REAR PANEL. FOUND BPCU FAULTS "SHORTED PMG TRIP" AND "GEN-FIELD WIRING-GCU". REPLACED APU GCU, NO HELP. FOUND WIRE BETWEEN D264C PIN 4 AND D4040P PIN 4 OPEN. REPLACED APUC. CHECKED CONTINUITY FROM APU GEN SDR UALA2010042301350Power Supply · faultyROW 19, (1) STRIP OF FLOOR LIGHTING CAME ON 2 HOURS INTO THE FLIGHT. CHECKED EMERGENCY LIGHT SYS IAW AMM, NO FAULTS FOUND. DUE TO PREVIOUS HISTORY, REPLACED POWER SUPPLY M1559. RECHECKED SYS, OPS NORMAL.SDR UALA2010042201341Actuator · stuckUNABLE TO START APU 'APU FAULT' EICAS MSG. FOUND 'NO FLAME' MSG ON APU CONTROL BOX. PERFORMED FIM AND FOUND APU FUEL VALVE STUCK IN CLOSED POSITION. REPLACED APU FUEL VALVE ACTUATOR. APU OPS TEST PERFORMED, APU IS WORKING PROPERLY.SDR UALA2010031900916Window · crazedR2 AND L2 WINDOWS VERTICALLY CRAZED TO THE POINT OF RESTRICTING VISIBILITY. REPLACED BOTH L2 & R2 SLIDING WINDOWS.SDR UALA2010031200842Circuit Card · faultyRT ENG FIRE LP 1 ON STATUS PAGE. SAMC TEXT: CYCLED B22 ON P11 AND PERFORMED FIRE TEST FAULT CLEARED. CREW PUSHED POWER UP ON NR 2 ENG AND FAULT RE-APPEARED AND WENT AWAY WHEN BACK TO IDLE. REPLACED M683 CARD LOOP 1. RAN ENG, OPS CHECKS OKAY. NO FAULTS NOSDR UALA2010010700079Skin · corrodedLEFT HIGH GAIN BEAM STEERING ANT AT FUSELAGE SKIN CORROSION DUE TO INADEQUATE SEALING. DURING SEALANT REMOVAL FOR CORROSION INSP FOUND SCRIBE MARKS AROUND 30 PERCENT OF ANTENNA PERIMETER. REPAIRED IAW SRM. ACCOMPLISHED HFEC AND ULTRASOUND, ALL FOUND OK. ALODSDR UALA2010010500074Antenna · damagedWATER FALLING FROM OVRHD 22-23. R & R SATURATED INSULATION BLANKETS. REPLACED 2 EA ADF ANTENNAS AND LOW GAIN ANT. WORKING BOTH HIGH GAIN ANT REPLACED. RT INBD AILERON TRACKING B5971. WORKING INSULATION BLANKETS.SDR UALA2009113003704Regulator · malfunctionedCREW OXYGEN MASK PROBLEM. POSITION 1.(1=CAPT,2=FO, 3=1ST OBS,4=2ND OBS). CREW COMMENTS: HEAD HARNESS LEAKS ATTACHMENT POINT WITH REGULATOR WHEN SQUEEZING TRIGGERS TO INFLATE. REPLACED O2 MASK-REGULATOR. OP CHKS NORMAL.SDR UALA2009111603563Connector · disconnected2 FOOT SECTION OF EMERGENCY EXIT FLOOR LIGHTING IN FRONT OF L SIDE MID LAV BLINKING INTERMITTENTLY. RECONNECTED EMERGENCY LIGHT PLUG. CHECKED OKAY.SDR UALA2009111003516Starter · faultyNO ROTATION ON LEFT ENGINE WHEN ATTEMPTING TO ENGAGE STARTER. REPLACED STARTER & STARTER VALVE. OPS ARE NORMAL.SDR UALA2009110603462Engine · vibrationNR 2 ENG VIBRATION. NR 2 ENG EICAS VIB READS HIGH. HIGHEST READING 35 (X.X, RANGE 0.0 TO 5.0, ABNORMAL ON 767-322 IF ABOVE 4.0). EXCESSIVE VIBRATION NOT FELT IN AIRFRAME. 3.5 IS REACHED AT 1.11EPR. AT ALL OTHER EPR SETTINGS THE VIB IS LOWER. ACPD VISUAL INSDR UALA2009091402877Power Supply · faultyNEAR DOOR 2L EMERGENCY FLOOR PATH LIGHTING FLASHING ON AND OFF. REPLACED EMERGENCY LIGHT POWER SUPPLY (M1561). LIGHTS OPS CHECKED NORMAL.SDR UALA2009090402795Actuator · failedRIGHT AILERON LOCKOUT ACTUATOR FAILS LOCKOUT ACTUATOR AND MECHANISM TEST. RIGHT AILERON LOCKOUT ACTUATOR REPLACED. TESTED AILERON LOCKOUT SYSTEM, OPS NORMAL.SDR UALA2009090302771Light · inoperativeTWO EMERGENCY AISLE LIGHT ASSYS INOP AT 2B AND 7B. RELAMPED, NO HELP. NEED TO REMOVE SEAT 1A TO ACCESS POWER SUPPLY M735 FOR FURTHER T/S.SDR UALA2009082702687Cooling Fan · malfunctionedSTATUS MESSAGE, FWD EQ EXH FAN. REPLACED THE CENTER FAN CONTROL CARD, NO HELP. REPLACED FAN. MESSAGE GONE; FAN RUNS.SDR UALA2009082002557Fuse · malfunctionedPER CREW ACFT WILL NOT ACCEPT GROUND POWER. REPLACED BUS POWER CONTROL UNIT. REPLACED ONE INTERLOCK FUSE, GND INDICATION OF EXTERNAL PWR NORMAL.SDR UALA2009081102448Gcu · faultyAPU GENERATOR INOPERATIVE. MM COMMENTS: APU GENERATOR SHUTDOWN AT DEPARTURE. RECYCLED SWITCH, NO HELP. REPLACED APU GCU. OPS CHECK NORMAL ON GROUND.SDR UALA2009081102447Stator · damagedCREW REPORTS AFTER RT ENG START, EICAS MSG'S 'R ENG EEC C1','R ENG CNTL' STATUS MSG'S, AND 'RT ENG CNTL' ADVISORY MSG DISPLAYED. REPLACED ALTERNATOR STATOR FOR EEC RAN ENG ON A AND B CHANNELS NO MAINTENANCE OR STATUS MESSAGES.SDR UALA2009080302309Connector · corrodedCONNECTOR M1944 AT LEFT MAIN TANK, CORRODED, FAILED LOOP RESISTANCE CHECK. REPLACED BACKSHELL ASSY ON CONNECTOR M1944. BOND CHECKS, BITE CHECKS, AND LOOP RESISTANCE CHECKS GOOD.SDR UALA2009080302305Ram Air Turb · faultyRAT DID NOT COMPLETELY DEPLOY AND PUSH BUTTON DID NOT STAY FLUSH, HAD UNLOCK LIGHT BUT NO PRESSURE LIGHT. (REFLY) RAT SYS TEST GOOD. MANUALLY DEPLOYED RAT 5 TIMES, ALL GOOD.SDR UALA2009080302304Connector · corrodedFOUND CONNECTOR M1946 CORRODED, LEFT AUX FQIS. INSTALLED NEW M1946 BACKSHELL CONNECTOR KIT. ELECT AND BONDING CHECKS GOOD. LOOP RESIST TEST GOOD. READS 14.10 OHMS.SDR UALA2009080302303Connector · looseEMERGENCY EXIT FLOOR STRIP LIGHT BY G2 IS INOP. FOUND EMERGENCY LIGHT STRIP LOOSE AT CONNECTOR AT G2. REPAIRED AND OPS CHECKS GOOD.SDR UALA2009073102296Floorbeam · crackedELECTRONICS BAY, MAIN CABIN FLOORBEAM UPPER CHORD HAS EVIDENCE OF CRACK STARTING AT FASTENER'S HOLE, STA 325, RBL 11. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED SECTION OF FLOORBEAM T-CAP, RBL 11 TO RBL 25. INSTALLED NEW SECTION T-CAP AND ANGLE DOUBLER REPASDR UALA2009072202164Static Inverter · malfunctioned"STBY INVERTER" EICAS, FLIGHT DIVERTED. DUE TO OVERHEAT DAMAGE REPLACED STANDBY INVERTER. ALSO REPLACED LEFT & RIGHT TRANSFORMER-RECTIFIERS. OPS CHECKS GOOD.SDR UALA2009040600989Gauge · leakingLOW PRESSURE. LEAKING FROM TOP OF GAUGE FAC THAT WAS BENT. REPLACED GAUGE.SDR UALA2009032300869Socket · shortedFOUND AFT LEFT LAV DOME SOCKET SHORTED, REMOVED POWER WIRE AND SECURED. FOUND AFT LEFT LAV DOME SOCKET SHORTED, REMOVED POWER WIRE AND SECURED. NEEDS SOCKET, NOT STOCKED ORD. REPLACED LIGHT SOCKET, OP CHECKED OKAY.SDR UALA2009020200364Feeder Cable · misinstalledNR 1 ENG IDG FEEDER CABLES ARE INCORRECTLY ROUTED. REROUTED FEEDER CABLES FROM UPPER ENG AREA TO NR 1 IDG DISCONNECT. SECURED HARNESS.SDR UALA2009011500169Engine · oil consumptionOIL CONSUMPTION IS TRENDING UP. REPLACED NR 2 ENGINE FCOC. RUN CHECK NORMAL, NO LEAKS.
Back to N658UA