N659AW
Service difficulty reports · 232
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N659AW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N659AW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA2009090892382Lens · missingFLT 394 - LAS - EEL - EMERGENCY LIGHT LENS MISSING SEAT 13L. MAINTENANCE INSTALLED MISSING LENS.SDR USAA2009081792135Battery Pack · dischargedFLT 680 - PHX - EEL - AFT FLIGHT ATTENDANT FLASHLIGHT INOPERATIVE. MAINTENANCE REPLACED BATTERY PACK.SDR USAA920081750Wire · damagedFLT NR 231 - LAS - FLOOR AISLE EMERGENCY LIGHT INOP 22L. REPAIRED BROKEN WIRE UNDER SEAT. OPS CHECK GOODSDR USAA920080716Windshield · crackedFLT 17 - JFK - PHX - DIVERSION - FIRST OFFICER'S OUTER PANE WINDSHIELD CRACKED. AIRCRAFT DIVERTED TO PHL WHERE THE F/O'S WINDSHIELD WAS REMOVED AND REPLACED.SDR USAA920080450Smoke Detector · defectiveFLT 920 - PHX-PDX - EE - CARGO SMOKE DETECTOR FAULT. MAINTENANCE REMOVED AND REPLACED THE SMOKE DETECTOR CONTROL UNIT AND CARGO SMOKE DETECTOR. OPERATIONAL CHECK WAS GOOD. CARGO SMOKE DETECTOR, MFR SIEMENS, MPN PPA1102-00, MSN 2199, TOTAL TIME 21393, TOTAL SDR USAA920071374Smoke Detector · false activationFLT 0025 - FFW - PHX - CREW REPORTED LAVATORY SMOKE DETECTOR FAULT LIGHT ILLUMINATED. MX REPLACED THE LAVATORY SMOKE DETECTOR IAW 26-16-15. OPERATIONAL CHECK WAS GOOD. A/C WAS RETURNED TO SERVICE.SDR AWXA200601919Power Supply · faultyLAS - EEL - FORWARD EMERGENCY LIGHT POWER SUPPLY HAS INTERNAL FAULT. MAINTENANCE REPLACED THE FORWARD EMERGENCY LIGHT POWER SUPPLY IAW TASK CARD R1C33303, OPS CHECK WAS GOOD.SDR AWXA200501457Fuel Divider · failedLAS - SMOKE - ON GROUND CATERER REPORTED EXCESSIVE SMOKE COMING FROM APU AND A GATES AGENT REPORTED FLAMES COMING FROM APU. THE APU WAS SHUT DOWN, NO ECAM MESSAGE. APU WAS DEFERRED. MAINTENANCE REMOVED AND REPLACED THE FUEL DIVERTER IAW AIRBUS 320 AMM 49-32SDR AWXA200600250Skin · damagedPHX - DURING INSPECTION DISCOVERED RT ELEVATOR HAD TRAILING EDGE DAMAGED. MAINTENANCE REMOVED DAMAGED SECTION ON THE TRAILING EDGE OF THE RT ELEVATOR. FABRICATED REPAIR PARTS FROM 2024T3 IAW AMERICA WEST AIRLINES ENGINEERING REPAIR NR 26-5520-05256-HF1. INSSDR AWXA200500852Wire Harness · damagedDURING EMERGENCY LIGHT OPERATIONAL CHECK, THE FORWARD LEFT EPSU FAULTED EXTERNAL LIGHT. MAINTENANCE REMOVED AND REPLACED THE L1 SLIDE IAW AMERICA WEST AIRLINES TASK CARD R1C25305. FOUND LAMP HARNESS DAMAGED. LAMP HARNESS WAS REPLACED IAW CMM 53-60-56 REV. 1SDR AWXA200500561Slide · faultyLAS - EEL - DURING 8-DAY CHECK THE EMERGENCY LIGHT SYSTEM TEST FAILED FOR EPSU EXT LOAD FWD L. MAINTENANCE ISOLATED PROBLEM TO THE L-1 DOOR SLIDE, REMOVED AND REPLACED L-1 DOOR SLIDE ASSEMBLY, OPERATIONAL CHECK WAS GOOD.SDR AWXA200500221Container · delaminatedSAL - EES - DURING BC-4 CHECK THE EXTERIOR SURFACE OF THE RT OVERWING SLIDE STOWAGE CONTAINER WAS FOUND DELAMINATED AT THE FORWARD LOWER CORNER. MAINTENANCE REMOVED AND REPLACED THE RT OVERWING SLIDE ASSEMBLY IAW T/C C1A25301.SDR AWXA200500220Floorbeam · corrodedSAL - MAJOR REPAIR - DURING BC-4 CHECK EXFOLIATION CORROSION WAS FOUND ON FLOOR SUPPORT BEAM Y765 AT FR 16. MAINTENANCE CUT OUT DAMAGED SECTION OF FLOOR SUPPORT BEAM Y765 AT FR 16; FABRICATED A NEW SECTION OF BEAM AND A SPLICE REPAIR; INSTALLED REPAIR PARTS ISDR AWXA200500219Floorbeam · corrodedSAL - MAJOR REPAIR - DURING BC-4 CHECK EXFOLIATION CORROSION WAS FOUND ON FLOOR SUPPORT BEAM Y1292 AT FR 16. MAINTENANCE CUT OUT DAMAGED SECTION OF FLOOR SUPPORT BEAM Y1292 AT FR 16; FABRICATED A NEW SECTION OF BEAM AND SPLICE REPAIR; INSTALLED REPAIR PARTS ISDR AWXA200500212Floorbeam · corrodedSAL - MAJOR REPAIR - DURING BC-4 CHECK CORROSION WAS FOUND ON FLOORBEAM Y520 AT FR 16. MAINTENANCE REMOVED CORRODED SECTION OF FLOORBEAM Y520 FROM FR 12 TO FR 16; FABRICATED A NEW REPLACEMENT SECTION OF BEAM PER DWG D53112825; INSTALLED REPAIR PART IAW A320 SSDR AWXA200500210Floorbeam · corrodedSAL - MAJOR REPAIR - DURING BC-4 CHECK EXFOLIATION CORROSION WAS FOUND ON FLOORBEAM -Y1292 AT FR 68. MAINTENANCE REMOVED CORRODED FLOORBEAM -Y1292 FROM FR 68 TO FR 70; FABRICATED A NEW REPLACEMENT FLOORBEAM PER DWG D53472040; INSTALLED REPAIR PART IAW A320 SRSDR AWXA200500207Floorbeam · corrodedSAL - MAJOR REPAIR - DURING BC-4 CHECK EXFOLIATION CORROSION WAS FOUND ON FLOORBEAM Y1292 AT FR 68. MAINTENANCE REMOVED CORRODED FLOORBEAM Y1292 FROM FR 68 TO FR 70; FABRICATED A NEW REPLACEMENT SECTION OF FLOORBEAM PER DWG D53472040; INSTALLED REPAIR PART IASDR AWXA200500206Seat Track · corrodedSAL - MAJOR REPAIR - DURING BC-4 CHECK EXFOLIATION CORROSION WAS FOUND ON FLOORBEAM Y1292 AT FR 66+3 INCHES. MAINTENANCE REMOVED CORRODED FLOORBEAM Y1292 FROM FR 66 TO FR 69; FABRICATED A NEW REPLACEMENT SECTION OF FLOORBEAM PER DWG D53472090; INSTALLED REPAISDR AWXA200500205Floorbeam · corrodedSAL - MAJOR REPAIR - DURING BC-4 CHECK EXFOLIATION CORROSION WAS FOUND ON FLOORBEAM -Y765 AT FR 66. MAINTENANCE REMOVED CORRODED FLOORBEAM -Y765 AT FR 66; FABRICATED A NEW REPLACEMENT SECTION OF FLOORBEAM PER DWG D53472090; INSTALLED REPAIR PART IAW A320 SRM SDR AWXA200500204Sill · corrodedSAL - MAJOR REPAIR - DURING BC-4 CHECK EXFOLIATION CORROSION WAS FOUND ON LOWER SILL -Y1732 AT FR 66. MAINTENANCE CUT OUT DAMAGE IN LOWER SILL -Y1732 AT FR 66; FABRICATED A REPAIR ANGLE; INSTALLED REPAIR PART IAW A320 SRM 53-41-14, FIG 201.SDR AWXA200500203Floorbeam · corrodedSAL - MAJOR REPAIR - DURING BC-4 CHECK EXFOLIATION CORROSION WAS FOUND ON FLOORBEAM -Y1292 AT FR 66+8 INCHES. MAINTENANCE REMOVED CORRODED FLOORBEAM -Y1292 FROM FR 66 TO FR 68; FABRICATED A NEW REPLACEMENT SECTION OF FLOORBEAM PER DWG D53472040; INSTALLED REPSDR AWXA200500189Seat Track · corrodedSAL - MAJOR REPAIR - DURING BC-4 CHECK EXFOLIATION CORROSION WAS FOUND ON FLOORBEAM SEAT RAIL Y765, AT FR 66. MAINTENANCE REMOVED CORRODED FLOORBEAM SEAT RAIL Y765, FROM FR 64 TO FR 66; FABRICATED A NEW REPLACEMENT FLOORBEAM SEAT RAIL PER DWG 18D53472040; INSSDR AWXA200500218Beam · corrodedSAL - MAJOR REPAIR - DURING BC-4 CHECK EXFOLIATION CORROSION WAS FOUND AROUND FASTENER HOLES ON SILL BEAM AT BULK CARGO DOOR FR 62+12 INCH, STR 38 RT. MAINTENANCE CUT OUT DAMAGED SECTION OF SILL BEAM AT BULK CARGO DOOR FR 62+12 INCH, STR 38 RT; FABRICATED A FSDR AWXA200500217Sill · corrodedSAL - MAJOR REPAIR - DURING BC-4 CHECK EXFOLIATION CORROSION WAS FOUND AROUND FASTENER HOLES ON SILL BEAM AT BULK CARGO DOOR FR 62+3 INCHES, STR 38 RT. MAINTENANCE CUTOUT DAMAGED SECTION OF SILL BEAM AT BULK CARGO DOOR FR 62+3 INCHES, STR 38 RT; FABRICATED A SDR AWXA200500216Sill · corrodedSAL - MAJOR REPAIR - DURING BC-4 CHECK EXFOLIATION CORROSION WAS FOUND AROUND FASTENER HOLES ON SILL BEAM AT BULK CARGO DOOR FR 61, STR 38 RT. MAINTENANCE CUT OUT DAMAGED SECTION OF SILL BEAM AT BULK CARGO DOOR FR 61, STR 38 RT; FABRICATED A FILLER AND DOUBLESDR AWXA200500215Sill · corrodedSAL - MAJOR REPAIR - DURING BC-4 CHECK EXFOLIATION CORROSION WAS FOUND AROUND FASTENER HOLES ON SILL BEAM AT BULK CARGO DOOR FR 60+11 INCHES, STR 38 RT. MAINTENANCE CUT OUT DAMAGED SECTION OF SILL BEAM AT BULK CARGO DOOR FR 60+11 INCHES, STR 38 RT; FABRICATEDSDR AWXA200500214Sill · corrodedSAL - MAJOR REPAIR - DURING BC-4 CHECK EXFOLIATION CORROSION WAS FOUND AROUND FASTENER HOLES ON SILL BEAM AT BULK CARGO DOOR FR 60, STR 38 RT. MAINTENANCE CUTOUT DAMAGED SECTION OF SILL BEAM AT BULK CARGO DOOR FR 60, STR 38 RT; FABRICATED A FILLER AND DOUBLERSDR AWXA200400972Battery Pack · dischargedDURING 4-DAY CHECK THE AFT SECTION OF SEAT MOUNTED EMERGENCY ESCAPE PATH LIGHTS FAILED TEST. MAINTENANCE REMOVED AND REPLACED LT OVERWING EMERGENCY LIGHT BATTERY PACK AT EMERGENCY POWER SUPPLY UNIT (11WL), FUNCTIONAL CHECK WAS GOOD.SDR AWXA200301211Control Unit · failedON SHORT AND FINAL APPROACH INTO EWR EN ROUTE FROM PHX RECEIVED LANDING GEAR CONTROL AND INTERFACE UNIT (LGCIU) FAULT. EXECUTED MISSED APPROACH AND DECLARED EMERGENCY ON SECOND APPROACH. CONTRACT MAINTENANCE PERFORMED A LANDING GEAR BITE TEST IAW AMM 32-69-00,SDR AWXA200200993Windshield · failedFLT 0722 - EN ROUTE FROM LAS TO ORD THE LT WINDSHIELD OUTER PANE SHATTERED, DIVERTED TO DEN AND LANDED WITHOUT FURTHER EVENT. AIRCRAFT WAS MAINTENANCE FERRIED TO PHX FOR WINDSHIELD REPLACEMENT. MAINTENANCE IN PHX REMOVED AND REPLACED THE LT WINDSHIELD IAW AMMSDR AWXA200200657Power Supply · defectivePHX - EEL - FORWARD FLIGHT ATTENDANT PANEL INDICATES INTERIOR EMERGENCY LIGHT FAULT CODE. MAINTENANCE REMOVED AND REPLACED EMERGENCY POWER SUPPLY UNIT (10WL) IAW AMM 33-51-38-000-001, OPERATIONAL CHECK WAS GOOD.SDR AWXA0000614Adc · failedEMERGENCY DECLARED, FLT LEVEL 350 AP 1 DISCONNECTED ON ITS OWN FOLLOWED BY C/CTL ALTN LAW AND CABIN PRESSURE SYS 1 FAULT, THEN A SFCS MSG DURING APPROACH AT 210 KTS. REMOVED AND REPLACED NR 1 ADRIU AND NR 2 AOA SENSOR.