N660UA
Service difficulty reports · 347
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N660UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N660UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2015010992923Battery · dischargedEMERGENCY EXIT LIGHT INOPERATIVE AT CEILING ABOVE SEAT ROW 13 LT. REPLACED BATTERY & POWER SUPPLY CHARGER IAW AMM 33-51-07.SDR CALA2015010992922Battery · dischargedSEAT MOUNTED EMER EXIT LIGHTS INOPERATIVE FROM SEATS 19 LT - 24 LT. REPLACED BATTERY & POWER CHARGER IAW AMM 33-51-07 & ACCOMPLISHED SYS TEST FOR SAME.SDR CALA2014031490603Placard · missingLT FWD OVERWING ESCAPE HATCH DISARM HANDLE DOES NOT HAVE ARMED PLACARD ON HANDLE VISIBLE, WHEN HANDLE IS PLACED IN THE ARMED POSITION. HATCH & SLIDE ARE CURRENTLY ARMED, INSTALLED PLACARD.SDR CALA2014010290035Pressure Switch · dirtyRT ENG ANTI ICE VLV INTERMITTENTLY CAME ON AT ALL POWER SETTINGS. CLEANED RT ENG ANTI ICE PRESS SWITCH. ALL OPERATIONS CHECKED SATISFACTORY.SDR CALA2013122393858Longeron · crackedLT UNDERWING LONGERON FITTING INSPECTION. FOUND CRACKED. ACCOMPLISHED LT UNDERWING LONGERON INSPECTION. THE LONGERON WAS FOUND CRACKED, REQUIRING ISSUANCE OF OP NR 3 OF EA 5710-02220, REV A. OP NR 3 COMPLIED WITH IN CONJUNCTION WITH ECRA 5710-02331 FOR MINOR DSDR CALA2013112293202Fseu · faultyEICAS MSG TE FLAP DISAGREE & TE FLAP LIGHT ILLUMINATED, WHEN FLAP LEVER & INDICATOR IN SAME POSITION. INTERMEDIATE TE FLAP DISAGREE DURING TAXI WITH FLAPS SET TO 15, ITEM ROLLED FORWARD. ADJUSTED OTBD SLAT PDU SENSOR M548, CHECKED ADJUSTMENT OF FLAP LEVER POSDR CALA2013111492933Light · inoperativeFOUND RT BLEED LIGHT KORRY SWITCH. REPLACED RT P5 PANEL BLEED LIGHT WITH SPARE, NO HELP. POSSIBLE SOCKET BAD OR PANEL R & R. R & R RT BLEED KORRY SWITCH RT BLEED LIGHT, CHECKED GOOD.SDR CALA2013110792725Probe · faultyRT AUXILIARY PITOT EICAS & LIGHT. REPLACED RT AUXILIARY PITOT PROBE.SDR CALA2013092591460Blade · damagedRT ENGINE FAN BLADE TIP REPAIRED. NEEDS NDT INSPECTION. REPAIRED AREA TO BE EDDY CURRENT INSPECTED IAW UA NTM PART 6, 72-31-401 WITHIN 6 FLIGHT CYCLES. CURRENT PTC 13948. BLADE NBR 1. ALSO IDENTIFIED WITH WHITE DOT. INSPECTION PERFORMED AMM 72-31-02 PARA SDR CALA2013092491410Smoke Goggles · missingOBSERVERS SMOKE GOOGLES MISSING. ROBBED SMOKE GOGGLES FROM SECOND OBSERVERS SEAT. SECOND OBSERVERS SEAT INOPERATIVE. REPLACED MISSING SMOKE GOGGLES AT SECOND OBSERVERS SEAT.SDR CALA2013102392332Servo Valve · faultyLT AUTOPILOT DISCONNECTED TWICE DURING CLIMB OUT. RT AP OPERATES NORMALLY. R & R EAS SERVO VLV FOR CNTR SERVO IAW AMM 22-12-02. R & R FCC CNTR IAW AMM 22-11-01. OPERATIONS CHECKED NORMAL, NO LEAKS FOUND. TEST 8 & 30 PASSED. A-C CAT IS FULL CAPABILITY.SDR CALA2013090991106Packing · distortedFOUND HYDRAULIC LEAK UNDER RT WING. DISTORTED PACKING AT UNION FOR OUTPORT B ANTI-SKID MODULE ASSEMBLY NORMAL. PRESSURED SYSTEM NO LEAKS NOTED.SDR UALA2013072305192Processor · faultyRT FUEL QTY BLANKING. REPLACED FQP IAW 28-41-08 AND RT TANK PROBES NR 5 AND 7 IAW 28-41-01. MOVED FUEL FROM LT TO RIGHT AND BACK. ALL INDICATIONS WERE NORMAL. SCREEN DID NOT BLANK OUT.SDR UALA2013072305191Computer · faultyDUE TO HISTORY OF RT FUEL QTY BLANKING REPLACED RT FMC COMPUTER IAW AMM 28-41-00-0100A. ACCOMPLISHED R & R OF RT FMC. DATA CROSSLOAD AND OPS CHECKED GOOD.SDR UALA2013072305169Transceiver · faultyCONSTANT STATIC ON VHF 2 RADIO ONLY ON 121.5, NR 1 RADIO 121.5 OK REPLACED NR 2 VHF TRANSCEIVER, ALSO PERFORMED GROUND RADIO CHECK. CHECKED OK.SDR UALA2013071604994Controller · faultyLEFT ENGINE PRIORITY VALVE EICAS ILLUMINATED. REPLACED PRIORITY VALVE CONTROLLER.SDR UALA2013071504921Densitometer · malfunctionedFUEL QTY BLANKING, REPLACED DENSITOMETER IAW 28-41-03. PERFORMED TEST IAW, NO FAULTS.SDR UALA2013071204902Exciter · inoperativeAPU EXCITER BOX INOPERATIVE. R & R EXCITER BOX, OPS CKS GOOD. SN PART INSTALLED 0916250, 402068.SDR UALA2013071204901Engine · hung startAPU WILL NOT START. HANGS BETWEEN 25 AND 35 PERCENT RPM AND SHUTSDOWN WITH FAULT LIGHT ON. R & R IGNITER , LEAD AND STARTER MOTOR, OPS CKS GOOD.SDR UALA2013070104583Shutoff Valve · failedEICAS MESSAGE "LT ENG PRV" CREW PERFORMED FLIGHT MAN PROCEDURE FOR LT PRV. WITH LT BLEED SELECTED OFF. THE LT BLEED MANIFOLD SHOWED 10 PSI & LT PACK DID NOT GIVE OFF LIGHT. SUSPECT PRSOV NOT FULLY CLOSED IN ADDITION TO PRV FAULT. REPLACED PRV REF AMM. RANSDR UALA2013062704507Antenna · damagedWEATHER RADAR PAINTS SIGNIFICANT GROUND RETURN ON LEFT SIDE, WITH NO VISIBLE MOISTURE (OR TERRAIN). TROUBLESHOT & CHECKED FOR MOISTURE REF 53-12-01. NO MOISTURE FOUND, INSPECTION OF FLAT ANTENNA HAS DAMAGE LOWER LEFT CORNER BENT. R & R FLAT PLATE ANTENNA.SDR UALA2013062504392Processor · inoperativeRT FUEL QTY INDICATOR IS INOPERATIVE ON OVERHEAD. R & R FUEL QTY PROCESSOR IAW MM. OPS NORMAL.SDR UALA2013062004289Indicator · malfunctionedFUEL TANK AND TOTAL FUEL QTY INDICATOR INOPERATIVE. INDICATOR BLANK EICAS MESSAGE, FUEL QTY INDICATOR NOT DISPLAYED. PERFORMED OPS AND BITE CHECK OF FQIS. ALL OPS, INDICATION AND BITE CHECKED GOOD. PROCESSOR SHOWS NO CURRENT FAULTS.SDR UALA2013060703963Relay · failedFUEL QTY INDICATOR, CHANNEL MSG'S PROBLEM NOT CODED. CREW COMMENTS: CB C34 "FUEL QTY 1" POPPED IN FLIGHT. FUEL QTY STILL INDICATES NORMALLY. REPLACED K356 FUEL QUANTITY TRANSFER RELAY RESET BREAKER PERFORMED FQIS PROCESSOR BITE AND OPS TEST, OPS CHECK NORMASDR UALA2013052403616Blade · damagedNR 1 ENGINE FOUR LPC BLADES DAMAGED ON L/E, BLADES NOT NUMBERED. BLENDED IAW MM72-31-02. CARRIED FORWARD RAISED FOR HFEC INSP TO BLADES (X4) TO BE ACP IAW NTM UAL PART 6 72-31-401 WITHIN 6 CYCLES.SDR UALA2013052803681Blade · nickedNR 1 ENGINE HAS ONE 1ST STAGE FAN BLADE WITH A L/E NICK LOCATED 5" FROM TIP IN AREA "A" & IS 0.060" DEEP. ACP BLEND TO LE OF BLADE IAW MM, BLEND WHITE DOTTED & CARRY FORWARD RAISED FOR HFEC INSP TO BE ACP WITHIN 6 CYCLES IAW NTM UAL PART 672-31-401. ACCOMPLISSDR UALA2013052403623Blade · dentedNR 2 ENGINE FIRST STAGE FAN BLADE NR 36 HAS TWO DENTS ON L/E. ON LOCATED TWO INCHES FROM TIP AND MEASURES 0.20 INCH DEEP AND ONE LOCATED SIX INCHES FROM MIDSPAN SHROUD AND IS 0.060 INCH DEEP. ACCOMPLISHED BLEND TO L/E OF BLADE NR 36 IAW MM.SDR UALA2013043003013Unknown · unknownVERY LOUD AIR NOISE FROM CEILING DUCTS ON RT SIDE AT THE BUSINESS GALLEY. INSPECTED MID GALLEY ZONE FOR DAMAGE ON DUCTS, NO FINDINGS. COULD NOT DUPLICATE.SDR UALA2013042202780Actuator · leakingHYDRAULIC LEAK COMING FROM LEFT OUTBD AILERON. LEAK WAS FROM AILERON ACTUATOR ROD, APPROX 15 DRIPS PER MINUTE WITH PRESSURE ON 0 WITH PRESSURE OFF.SDR UALA2013041202510Wire · defectivePIGTAIL IN ECON GALLEY SMOKING. P52 LOC. PULLED AND CAPPED P52 CB. REPLACED PIGTAIL.SDR UALA2013032001716Autothrottle Sys · malfunctionedAUTOTHROTTLES KICKED OFF THREE TIMES. ACCOMPLISHED CATIII CHECK, FAILED TLA FWD L/R.SDR UALA2013031101441Hydraulic Line · leakingHYDRAULIC FLUID LEAKING FROM L MAIN STRUT. ABOUT 3 DRIPS PER MINUTE WITH SYSTEM PRESSURE. FOUND BAD HYDRAULIC LINES FROM LEFT MAIN STRUT HYDRAULIC ANTI-AUTOBRAKE SYSTEM ITEM 955, 975 REF IPC 32-41-65-001 PG 1. REPLACED FAULTY HYD LINES PER AMM. LEAK CHECKESDR UALA2013022601155Connector · dirtyCREW REPORTED APU DOOR STATUS MESSAGE DURING TAXI OUT. CYCLED APU MASTER SWITCH, MESSAGE REMAINS. ACCOMPLISHED BITE CHECK OF CONTROLLER, NO MESSAGES, CLEANED CONNECTOR ON APU DOOR ACTUATOR. ACCOMPLISHED THREE APU STARTS. NO MESSAGE FOUND, OPS CHECKED GSDR UALA2013021100779Drain Mast · obstructedFWD LAVATORY OVERFLOWED, RETURNED TO FIELD. FOUND PLASTIC CAP IN FWD DRAIN MAST. REMOVED CAP, CLEARED DRAINS. CHECKED FWD SINKS AND GALLEY DRAINS FOR CLOGS, OPS CHECKED GOOD.SDR UALA2013020400684Controller · faultedLEFT ENGINE HPSOV MESSAGE WHEN REDUCING THRUST FOR DESCENT. BITE TEST CONFIRMS HPC FAULTY, REPLACED PER MM. ACTIVATED HPSOV. BITE TEST NO LONGER FAULTING HPC.SDR UALA2012120406946Anti-Skid Valve · crackedRIGHT HYD SYSTEM QUANTITY SLOWLY DECREASED DURING FLT TO .057 (RF). REPLACED CRACKED RIGHT OUTBOARD ANTISKID VALVE (PCN 643-0746) PER AMM, LEAK CHECKED GOOD.SDR UALA2012111406574Seal · out of positionSEAL ON LEFT GEAR HAS SLIPPED; MAY INTERFERE WITH GEAR RET-EXT. REPOSITIONED AND SECURED SEAL ON LEFT MAIN GEAR DOOR.SDR UALA2012103106274Accessory Unit · malfunctionedOVERWING CROSS AISLE INTERPHONE CANNOT CALL AFT CABIN. REPLACED MID HANDSET (P/N 285N0412-3 - POSITION 3) AND AUDIO ACCESSORY UNIT, SYSTEM CHECKS NORMAL WHILE AT THE GATE.SDR UALA2012102306084Indication Sys · inoperativeCREW REPORTS RT MAIN FUEL QTY INDICATION INOP ON FLT DECK AND FUELING PANEL. PLACED RT MAIN FUEL QTY INDICATION INOP ON FLT DECK AND FUELING PANEL. REF NUMBER 2841P, COMPLIED WITH DDP USED ALTERNATE FUELING PROCEDURES.SDR UALA2012082904847Warning Light · false activationLEFT WING HYD VALVE EICAS MESSAGE OFF LIGHT ILLUMINATED AFT PANEL. VERIFIED VALVE IN OPEN POSITIONS PER MAINT PROCEDURE.SDR UALA2012082804826Gasket · out of positionLEFT SIDE HORZ STAB HAS APPROX 4 FT RUBBER GASKET HANGING DOWN. BLADE SEAL AND REMAINING SEALANT MATERIAL ARE SECURED AND UNDAMAGED. SPEED TAPE APPLIED PER ECRA 5510-02249. ACP DAILY INSP OF SPEED TAPE SECURITY. REAPPLY IF NECESSARY. REPAIR AND REAPPLY SESDR UALA2012082404744Pseu · faultyCREW REPORTED AFTER TAKEOFF AND IN CRUISE, ALL THREE GREEN GEAR DOWN LIGHTS ILLUMINATED WITH THE GEAR HANDLE IN THE UP OR OFF POSITION WITH LANDING GEAR MONITOR, AIR-GRD DISAGREE AND NOSE AIR-GRD DISAGREE STATUS MSG'S DISPLAYED ON EICAS. NO ABNORMAL VIBRATIONSDR UALA2012082104678Warning System · false activationCREW REPORTS RT REVERSER ISOLATION EICAS MSG & REV ISOL LIGHT ILLUMINATED AFTER ENGINE START. ALL CB' S ARE IN AND NO MESSAGES ON EPCS PG. AIRCRAFT RETURNED TO GATE. PROG TEXT: ITEM ROLLED FORWARD. RIGHT ENGINE REVERSER LOCKED AS PER MEL 7831D. ACCOMPLISHSDR UALA2012082104670Fitting · crackedNR 1 PYLON HYD FITTING CRACKED. REF LM4404 REMOVED COVER PLATE ON ENGINE HYD QUICK DISCONNECT BOX, ALSO LOOSEN HYD LINE 'B' NUT IN BOX 1. 25 BONNEY WRENCH. REPLACED FITTING AND LINE. NO LEAKS FOUND. SECURED FITTING AND SECURED COVER PLATE.SDR UALA2012082104669Fitting · leakingHYD LEAK DISCOVERED DURING START VALVE INSPECTION OF THE NUMBER ONE ENGINE. LEAK APPEARS TO BE FROM UPPER INBOARD SIDE OF THE SUPPLY AND PRESSURE LINE FOR THE EDP. REPLACED UPPER FITTING AND HYD PRESSURE LINE ON NR 1 ENGINE. LEAK CHECK GOOD.SDR UALA2012082104681Start Valve · malfunctionedLEFT ENGINE STARTER EICAS. REPLACED NR 1 ENGINE START VALVE & OPS CHECKED GOOD.SDR UALA2012080804312Line · leakingLEFT HYD SYSTEM LOW. FOUND LEFT ENG HYD PRESSURE LINE LEAKING NEAR DISCONNECT. TORQUED, NO HELP. REPLACED HYD LINE FROM RACEWAY TO ENGINE DRIVEN HYD PUMP. TORQUED B-NUTS, PERFORMED DRY SPIN NO LEAKS FOUND. PERFORMED ENG RUN AS PER JRH FOR 5 MIN AND INSPESDR UALA2012073104126Engine · unknownAT FL360, IN SMOOTH AIR, FOR ABOUT 15 MINS, BOTH ENG HAD FLUCTUATING PARAMETERS. LEFT ENG EPR RAPIDLY CHANGED FM LESS THAN 1.0 TO 1.45, N1 +--4%, EGT +-- 6, FF +--.4. CHECKED LEFT PIMU EEC CH A REVERSER RNG FAIL DISPLACED CHECKED ASSOCIATED WIRING PLUGS AND SSDR UALA2012080604205Fmu · faultedNR 1 ENGINE 'ENG EEC C1' MESSAGE APPEARED ON EICAS. ENGINE OPERATION NORMAL. CREW COMMENTS: AUTOTHROTTLE OPERATING NORMALLY. DEFERRED AS PER MEL. PIMU FAULT 352-25 AND 353-25 OCCURRED ON FLT 909-08JUL. RANG OUT WIRING. W1P7 PIN G TO -A 241 OHMS. H TO F 302 OHSDR UALA2012071803896Densitometer · failedFUEL TANK AND TOTAL FUEL QTY INDICATOR INOPERATIVE, INDICATOR BLANK, FUEL QTY INDICATOR EICAS MESSAGE DISPLAYED. POSITION 2 (01=L, 02=R, 03=C). DENSITOMETER FAILED. REPLACED. OPS CHECKED GOOD.