N660UA
Service difficulty reports · 347
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N660UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N660UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011010300028Heat Exchanger · crackedLEFT PACK HAS CRACKED HEAT EXCHANGER WELD APROX 6 INCHES LONG MARKED WITH TAPE AND LEAKING EXCESSIVELY. REPLACED CRACKED SECONDARY HEAT EXCHANGER. OPS NORMAL.SDR UALA2010122704730Windshield · arcedF/O WINDSHIELD'S VISIBILITY IS IMPAIRED, REPLACEMENT IS REQUESTED. WINDOW IS ARCING IN TOP LT CORNER. APPEARS ASSOC W DELAMINATION. .5CM X 1CM W BROWNISH CT. R & R F/O WINDSHIELD IAW MM. ACCOMPLISHED INITIAL TORQUE.SDR UALA2010112904368Skin · damagedLARGE FASTENER MISSING FROM INBD SIDE NR 2 ENGINE PYLON, HOLE IS JUST IN FRONT OF PANEL 447ELX. BOLT IS THE FILLER FOR THE BOOTSTRAP SLING. NOT STRUCTURAL. TEMPORARY REPAIR WITH TAPE. REPLACED IN 5 CYCLES. SEE SERVICE TIP 54-52-01. IPC REF 54-51-57 ITEM 8SDR UALA2010100103642Linkage · brokenNR 1 ENGINE NOT SPOOLING UP PAST 50 PERCENT N1. ACCOMPLISHED ENGINE OVERSPEED INSPECTION CHECK. FOUND INLET GUIDE VANE LINKAGE BROKEN. REPLACED ENGINE.SDR UALA2010100103632Module · failedAPU AUTOSHUTDOWN ON TAXI OUT. APU CAME UP TO SPEED, GENERATOR CAME ON LINE THEN IT SHUTDOWN. REPLACED APU FLOW SENSING MODULE AND SURGE CONTROL VALVE IAW MM, NO HELP. FOUND BLOWN GASKET ON FLOW SENSOR REPLACE GASKET RUN APU, OPS CHECK GOOD.SDR UALA2010092703569Cylinder · reads lowNR1 LT ENTRY DOOR SLIDE CYLINDER PRESSURE IS LOW. REPLACED PASSENGER DOOR 1L ESCAPE SLIDE - RAFT.SDR UALA2010091403417Seal · missingON WALKAROUND FOUND UPPER INBOARD SEAL OF RIGHT INBOARD AILERON COMPLETELY MISSING. SEAT P-N 10-60754-221 NIS FRA. BOUGHT SEAL FROM LT FRA AND INSTALLED SAME ON ACFT. OK FOR SERVICE.SDR UALA2010090203222Circuit Breaker · pulledWATER QTY ISSUE, FLIGHT DIVERTED. FOUND U 28 CB POTABLE WATER WITH COLLAR ON IT. RESET, SERVICED WATER TANK TO FULL. CHECKED ALL LAVS AND GALLEY SPIGOTS. ALL FUNCTIONING NORMAL.SDR UALA2010082303078Connector · faultySEAT 8J ALL ELEC OPS ARE INOPERATIVE. INOP SEATS. MANUAL MODE OK. CONFIRMED IFE FUNCTION OF THE SEAT OPS CHK OK. REPAIRED SEAT. FOUND BAD CONNECTOR.SDR UALA2010081602996Antenna · faultyWWR RADAR FAIL ON BOTH SIDES. ANTENNA IN BLUE. REPLACED ANTENNA PER MM. OPS CHECK NORMAL.SDR UALA2010080402833Shutoff Valve · faultyENGINE BLEED ISSUE. ON SHUT DOWN LT HPSOV BLEED LIGHT ON. REPLACED HPSOV AND CHECKED IAW AMM, NO FAULT PRESENT. AFTER ENG START, UNABLE TO GET ANY BLEED PRESSURE OFF LT ENG. CYCLED LT ENG BLEED CONTROL CB AND NO HELP. REPLACED PRESSURE REGULATING AND SHUTOFF VSDR UALA2010080202795Connector · damagedRIGHT NR 7 SPOILER BLOWDOWN ACTUATOR CONNECTOR PINS BENT. REMOVED AND REPLACED SQUIB WITH NEW SQUIB IAW MM.SDR UALA2010080202762Structure · dentedBULK CARGO DOOR LOWER FWD CORNER HAS (2) DENTS. (1) DENT IS 0.5 INCH BY 0.25" DEEP AND THE OTHER 1.0 INCH BY 0.O50 INCH. BOTH DENTS ARE 2 INCHES FROM DOOR EDGE AT LOWER FWD CORNER. CUT-OUT DAMAGED AREA AND FABRICATED A REPAIR FILLER AND DOUBLER AND INSTALLEDSDR UALA2010071202458Terminal · brokenRT STAB POSITION TRANSMITTER CABLE TERMINAL ASSY IS BROKEN. REPLACED RT STAB POS. TRANSMITTER CABLE TERMINAL ASSY AND ACPD CABLE ADJUSTMENT. OP CHECK GOOD.SDR UALA2010070902452Shutoff Valve · intermittentNR 1 PRSOV INTERMITTENT OPERATION WHEN CHECKING IDLE RUN AIR PRESSURE. REMOVED NR2 PRSOV VALVE. RPLD NR 2 PRSOV. ACCOMPLISHED POWER RUN. NR 2 BLEED OPS CHECKED GOOD AT POWER. OVERNIGHT TROUBLESHOOTING IDENTIFIES PROBLEM AS BLEED PRESSURE DROPPING OFF TO MINISDR UALA2010031500851Overheat Loop · out of positionREPEAT GRIPE BODY DUCT OVERHEAT LIGHT ON MOMENTARILY AFTER SECOND ENG START. RAN ENGINES 1 AND 2 GOT DUCT OVERHEAT GOT LIGHT AGAIN. REPLACED CARD M691, NO HELP. RE-INSTALLED ORIGINAL CARD. FOUND DETECTION LOOP TS226 LAYING ON APU BLEED DUCT JUST FWD OF APUSDR UALA2010031500855Detection Sys · out of positionADP INOPERATIVE PERFORMANCE PENALTIES WILL BE APPLIED BECAUSE BODY LOOP DETECTION SYSTEM IS DEFERRED. FOUND DETECTION LOOP TS226 LAYING ON APU BLEED DUCT JUST FWD OF APU BLEED VALVE. REPOSITIONED LOOP. RAN ENG. DUCT LEAK LIGHT REMAINS EXTINGUISHED.SDR UALA2010031500854Shutoff Valve · faultyL & R DUCT PRESSURE SPLIT & ACFT ON GROUND, WITH ENG RUNNING, LT & RT ISOL VALVES CLOSED & BLEED SW ON. PRESSURE EQUAL WHEN N2 INCREASED ABOVE 82 PERCENT. NEED HIGH PRESSURE SHUTOFF VALVE ITEM NR 375. REPLACED NR 2 ENGINE HPSOV. OPS NORMAL.SDR UALA2010030800779Fire Loop · faultyEICAS MSG 'ENG1 FIRE LP2' DISPLAYED. (LT=1,RT=2). LOOP IS FAULTY. REPLACED UPPER AFT FIRE LOOP. TEST NORMAL. NO FAULTS.SDR UALA2010030500765Wire · damagedFOUND DAMAGED WIRES 6 INCHES UP FROM NR 1 ENGINE LWR AFT FIRE DET LOOP, ON OUTBD SIDE OF ENG. REF. WD 26-11-11. RETERMINATED WIRES AT LOOP TS662. OPS OKAY.SDR UALA2010022300674Controller · faultyON ENGINE SHUTDOWN GOT BLEED LT AND HPSOV MSG FOR RT ENGINE. REPLACED NR 2 ENG HIGH PRESSURE CONTROLLER. NEEDS RUN TO CONFIRM FIX. REPLACED M860 CARD FILE. REACTIVATED HPSOV AND TESTED OK ON ENG RUN.SDR UALA2010011500189Switch · faultedLT ENG FUEL FILTER EICAS, RTFL. REPLACED FILTER AND FUEL DIFFERENTIAL PRESSURE SWITCH RAN ENG, LEAK AND OPS CKS OK.SDR UALA2009122904046Circuit Card · malfunctionedPROBE HEAT EICAS MSG. AFTER ACFT JACKED FOUND THE FOLLOWING IND LTS ILLUM ON P11: LT AUX PITOT, FO PITOT, RT AOA. NEEDS FURTHER TROUBLESHOOTING. FOUND K518 ENERGIZED IN AIR, AT K518 PIN X2 HAD APPROX 4 VDC,SHOULD BE 28 VDC, REPLACED PSEU VOLTAGE AT K518 OK. OSDR UALA2009122403997Static Inverter · failedSTATIC INVERTER FAILURE. STATIC INVERTER REPLACED, ALL OPS AND INDICATIONS NORMAL.SDR UALA2009120303734Transceiver · malfunctionedUSING VHF-LT NO TRANSMITTING ACCOMPLISHED FROM ALL 3 MIC SELECTOR PANELS. REPLACED LT VHF TRANSCEIVER AND OPS CHECK GOOD.SDR UALA2009111603560Monitor · faultyRT & LT HYD QTY LWR EICAS, RTFL. FAULT OCCURRED AFTER STATIC DISCHARGE. REPLACED HYDRAULIC FLUID QTY MONITOR UNIT. ALL OPS CHECKS SATISFACTORY.SDR UALA2009102303317Anti-Ice Valve · stuckLEFT ENG ANTI ICE EICAS LIGHT CAME ON ATTEMPTING TO CLOSE ON GRD. APPEARS VALVE STUCK OPEN. REPLACED ENGINE INLET ANTI-ICE VALVE. OPS CHECK OKAY.SDR UALA2009100503122Transmitter · malfunctionedFLAP SLAT ELEC STATUS MESSAGE PROBLEM. ATTEMPTED TO DUPLICATE PROBLEM BY TAXIING AIRCRAFT IN TAKEOFF CONFIGURATION. IF NO FAULTS OCCUR WILL ACCOMPLISH FLAP POSITION TRANSMITTERS RESISTANCE CHECKS WHILE TAPPING ON TRANSMITTERS. IF NO FAULT FOUND WILL REPLACESDR UALA2009093003071Actuator · leakingNR 11 SPOILER ACT LEAKING HYD FLUID. REPLACED NR 11 SPOILER ACTUATOR.SDR UALA2009091802949Processor · defectiveCENTER TANK IND BLANKS AT HIGH DECK ANGLE. PRESENT LEG FAULT "HI-Z SHORT TO GRND AO1". WILL REQUIRE TANK DRAINED AND SUMP FOR DRY CAPACITANCE TEST. POSSIBLE TANK ENTRY AND HARNESS REPLACEMENT. PROCESSOR SHOWS SEVERAL FAULTS FOR CENTER TANK. REPLACED BOTH SDR UALA2009091402888Processor · malfunctionedFUEL CONFIG LIGHT ILLUM. WITH 'C' PUMPS ON AND MAINS BALANCED, EICAS MSG *FUEL CONFIG* DISPLAYED. ON INITIAL CLIMB FUEL CONFIG EICAS DISPLAYED, CTR TANKS INDICATED. FUEL PROCESSOR REPLACED, OP CKS OKAY.SDR UALA2009083102722Bottle · lowLEFT SIDE OVERWING ESCAPE SLIDE CYLINDER PRESSURE IS 0 PSI. REPLACED LEFT SIDE OVERWING ESCAPE SLIDE CYLINDER.SDR UALA2009081702513Smoke Detector · inoperativeLAV 123 SMOKE DETECTOR INOP. REPLACED SMOKE DETECTOR IN LAV 123. ITEM OK.SDR UALA2009081402498Monitor · faultyCENTER HYD QTY WENT FROM .85 TO .60. REPLACED HYD MONITOR UNIT.SDR UALA2009080602389Guard · damagedEVACUATION ALARM WENT OFF UNCOMMANDED DURING CRUISE. ACCOMPLISHED TEST AND TESTED NORMALLY. SUSPECT PROBLEM CAUSED BY DAMAGED GUARD AT DOOR 2L EVAC SWITCH.SDR UALA2009072002116Connector · disconnectedSEAT MOUNTED EMERGENCY LIGHT AT SEAT 24JK INOPERATIVE. FOUND LIGHT DISCONNECTED, SECURED CONNECTOR, OPS NORMAL.SDR UALA2009072002115Light · inoperativeEXTERIOR EMERGENCY LIGHT AFT LT SIDE INOP. RELAMPED EMERGENCY LIGHT, OPS NORMAL.SDR UALA2009070201899Battery · inoperativeDOOR L1 AND R4 AND LEFT OVERWING SLIDE EMERGENCY LIGHTS INOPERATIVE. DOOR L1 REPLACED BATTERY AND CHECKS GOOD. DOOR R4 CHECKS NORMAL.SDR UALA2009052601509Feeder Cable · arcedFOUND RT IDG FEEDER CABLE T3 ARCING AT CLAMP AT 0900 O'CLOCK POSITION. BEGAN REMOVING FEEDER CABLE AND LOOSENED CLAMPS FOR RT IDG FEEDER CABLE REPLACEMENT. WORKING CF0005. BEGAN REINSTALLATION OF ORIGINAL FEEDER CABLE, COMPLETED SECURING FROM IDG TO FEED THSDR UALA2009043001265Apu · faultyAPU FAULT AND AUTO SHUTDOWN. 4 TIMES EACH TIME APU LASTED FOR LESS TIME. DPI'S ON THE OIL FILTERS ARE GOOD. FOUND BIG CHIPS AND BALL BEARING ON GEAR BOX CHIP DETECTOR. ALL OIL DRAINED OUT BECAUSE VALVE DID NOT CLOSE. CHIP DETECTOR REINSTALLED. REPLACED ASDR UALA2009042901250Feeder Cable · shortedR GEN TRIPPED OFF LINE. FLIGHT DIVERTED. FOUND RT ENG IDG FEEDER CABLE SHORTED TO ADJACENT BRACKET. ALSO FOUND CHAFING AT CLAMP. WILL REQUIRE REPLACEMENT OF FEEDER CABLE. INTERIM RPR WITH SPLICE & NEW SECTION OF CABLE, RAN RT ENG PER JRH OKAY. THE PINS OSDR UALA2009042701207Idg · faultyEICAS MSG R GEN OFF DISPLAYED. GEN OFF LIGHT ILLUM & FAILED TO RESET. REPLACED IDG. SERVICED IDG TO FULL. ACCOMPLISHED OPS CHECK, FREQ AND VOLTS OKAY. FOUND FWD UPPER CONNECTOR, IDG SIDE CONTAMINATED WITH CARBON BUILD UP PIN TO PIN. REMOVED CARBON AND FLSDR UALA2009040600988Monitor · faultyENG VIBE BITE STATUS MSG WILL NOT CLEAR. REPLACED ENGINE VIBRATION MONITOR UNIT, RAN BOTH ENGINES. INDICATIONS ARE NORMAL.SDR UALA2009011200132Aspirator · leakingASPIRATOR LEAKING. MFG DEFECT. REPLACED BARREL.SDR UALA2008122907027Light · inoperativeRT EXTERIOR EMERG LIGHT INOP RT SLIDE LIGHT. RELAMPED, OPS OK.SDR UALA2008121506876Light · inoperativeCOCKPIT EMERGENCY EXIT LIGHT DOES NOT COME ON IN ARM WITH BATT AND STBY POWER OFF. REPLACED LIGHT ASSY AND OPS CHECKS GOOD.SDR UALA2008121506871Sign · faultyRT AISLE EXIT SIGN FAILS LIGHT COMPARATOR TEST. INSTALLED NEW SIGN.SDR UALA2008121506870Sign · faultyLT AFT AISLE EXIT SIGN FAILS COMPARATOR TEST. INSTALLED NEW EXIT SIGN AND OPS CHECKS GOOD.SDR UALA2008121506869Sign · faultyLT FWD AISLE EXIT SIGN FAILS LIGHT COMPARATOR TEST. INSTALLED NEW EXIT SIGN.SDR UALA2008121506868Lamp · inoperativeAFT LT EXTERIOR EMERGENCY LIGHT AT DOOR 4L IS INOP. RELAMPED AND RESEALED AND OPS CHECKS GOOD.