What was found
CENTER TANK IND BLANKS AT HIGH DECK ANGLE. PRESENT LEG FAULT "HI-Z SHORT TO GRND AO1". WILL REQUIRE TANK DRAINED AND SUMP FOR DRY CAPACITANCE TEST. POSSIBLE TANK ENTRY AND HARNESS REPLACEMENT. PROCESSOR SHOWS SEVERAL FAULTS FOR CENTER TANK. REPLACED BOTH LOW-Z & HI-Z CENTER TANK HARNESS. FQIS SYSTEM OP'S CHECK AND SYSTEM BIT CHECK PASSED NO FAULT. ALL FUEL WORK COMPLETE.