As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ON CLIMBOUT ON THEECAM VENT BLOWER AND EXTRACT APPEARED SUSPECTING POSSIBLE AVIONICS SMOKE HOWEVER NO OTHER INDICATIONS WERE PRESENT. PERFORMED AEVC TEST IAW 21-26-00. PFR SHOWS INLER EXTRACT FAULT AND VENT BLOWER FAULT. CLASS 3 FAULTS SHOW'S AEVC. OBSERVED DURING AEVC TEST, BOTH INLER AND EXTRACT VALVES STAYED CLOSED FOR APPROXIMATELY 15 MIN AFTER TEST. CONTINUED TO L/P 2532639-2