N668UA
Service difficulty reports · 349
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N668UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N668UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2012081304434Floorbeam · damagedBS 246 RBL 13.5 FLOORBEAM WEB REPAIR MUST RECEIVE 8100-9 SHOWING COMPLIANCE WITH 14 CFR 26.43. REPAIR ACCOMPLISHED ON HAECO NON ROUTINE HHY503372.SDR UALA2012050402637Connector · looseSEAT 24HJ EMERGENCY LIGHT INOPERATIVE. FOUND CONNECTOR LOOSE. SECURED CONNECTOR, OPS NORMAL.SDR UALA2012043002561Window · leakingLOUD SQUEAL FROM LEAK COMING FROM FIRST OFFICER WINDOW, NOISE WENT AWAY WHEN BELOW 10000 FT AND 220KIAS. CLEANED AND INSPECTED R1, 2, 3 COCKPIT WINDOWS. NO DEFECTS FOUND.SDR UALA2012022901259Pcu · leakingEVIDENCE OF SKYDROL AS VIEWED FROM GROUND COMING DOWN BOTH SIDES OF TAIL CONE ABOVE APU CONTINUING DOWN FUSELAGE TO BELLY DRIPPING ON GROUND. FOUND UPPER RUD PCU (CTR SYS) LEAKING FROM FWD ROD END, RPLCD UPR RUD PCU WITH BORROWED PCU FROM AA, SNAA10, PN 28290SDR UALA2012022201077Actuator · leakingDURING INSPECTION OF TAIL FOR HYD LEAKS, THE CENTER RUDDER PCA WAS FOUND TO BE LEAKING FLUID FROM SHAFT SEAL WHEN STATIC. RPL'D CTR ACTUATOR PER AMM.SDR UALA2012022101057Actuator · leakingHYDRAULIC FLUID LEAKING AND FLOWING ALONG TAIL SECTION NEAR APU AND ELEVATOR AREA. REMOVED LT OUTBOARD ELEVATOR PCA PER AMM. REMOVED AND REPLACED LT OUTBOARD PCA PER MM. VERIFIED OPS OF ELEVATOR WITH SYSTEM PRESSURIZED AND SINGLE HYDRAULIC SOURCE TEST. NO SDR UALA2012021300860Windshield Wiper · out of adjustCAPTAIN'S WINDSHIELD WIPER FLOATS ON WINDSCREEN NOT HELD AGAINST WINDOW. DEFERRED PER MEL, ADJUSTED CAPTAIN'S WIPER. OPS NORMAL.SDR UALA2012020600685Connector · dirtyRIGHT EMERGENCY ESCAPE SQUIB FAILS TO TEST. CLEANED CONNECTOR. TESTS OKAY.SDR UALA2012020300669Blade · nickedNR 2 ENG HAS 1EA NICKED FAN BLADE ON FAN BLADES NR 26 AND 35. BLENDED NR 2 ENG BLADES NR 26 AND 35 PER MM.SDR UALA2012020300681Panel · wornLEFT ENGINE, OUTBOARD PYLON PANEL 436AL HAS FASTENER HOLE WORN OUT FASTENER JUST FALLS THROUGH. ROUND SMALL PANEL WITH 4 FASTENERS. REMOVED PANEL AND PLACED IN LOB. PARTS: 160-8839 311T3065-159 (DOOR ASSY) REPLACED OLD PANEL WITH NEW PANEL. SECURED ON PYSDR UALA2012020200623Battery Pack · no testTEST 1 RIGHT SIDE SLIDE NO TEST. REPLACED RIGHT SIDE FWD SLIDE BATTERY PACK, TEST OKAY. ACCOMPLISHED CRITICAL STEP INSPECTION FOR INSTALLATION OF RT SLIDE BATTERY PACK. INSTALLED BATTERY PACK PER MM.SDR UALA2012011900421Hydraulic Line · leakingNR 2 HYD QTY READS XXRF. CREW COMMENTS: RIGHT HYDRAULIC QUANTITY SHOWS 0.44 RF SAMC TEXT: FOUND PIN HOLE ON RT OUTBOARD AILERON ACT PRSS LINE. NR 2 HYD QTY READS XXRF. SEE CREW COMMENTS FOR READING. RPL DAMAGE LINE WITH FLEX LINE BACH6M0310AA. PER GPMM SDR UALA2012010600142Helicoil · failedLEFT THRUST REVERSER DEACTIVATION PIN HELICOIL PULLED OUT. REPLACED RIGHT ENGINE INBOARD DEACTVATION PIN HELICOIL.SDR UALA2011120706734Selector Panel · faultedCAPTAIN'S VHF SWITCH INOPERATIVE, NO TRANSMIT. REPLACED AUDIO SELECTOR PANEL CHECKED OKAY.SDR UALA2011112706524Selector Panel · faultyFOUND CAPTS AUDIO CONT PANEL PTT SWITCH STICKING. SWITCH NOW UNSTUCK AND SWAPPED CAPTS WITH THE FIRST OBS SEAT. REPLACED F-OBS AUDIO SELECTOR PANEL.SDR UALA2011111406221Wire Harness · damagedFWD EMERGENCY LIGHT STRIP ON SEAT 1H INOPERATIVE. LIGHT STRIP CONNECTOR DAMAGED. CAPPED AND STOWED WIRES AND SECURED. REPLACED LIGHT HARNESS ASSY LIGHT TEST GOOD.SDR UALA2011111406217Battery Pack · faultyCABIN EMERGENCY EXIT FLOOR LIGHTS FLASH ON OFF INTERMITTENTLY. A ZONE, LEFT SIDE EMERGENCY LIGHTS FLICKERING. REPLACED BATTERY PACK AND OP CHECKED.SDR UALA2011111406197Connector · damagedFWD EMERGENCY LIGHT STRIP ON SEAT 1H INOPERATIVE. LIGHT STRIP CONNECTOR DAMAGED. CAPPED AND STOWED WIRES & SECURED. REPLACED LIGHT HARNESS ASSY LIGHT TEST GOOD.SDR UALA2011111406215Light · looseEMERG FLOOR LIGHT STRIP LOOSE ROW 1 RT SIDE. SECURED LIGHT STRIP.SDR UALA2011111406216Power Supply · inoperativeCREW REPORT: EMERGENCY FLOOR PATH LIGHTING ON FIRST CLASS RIGHT SIDE IN FLIGHT. REPLACED M730 POWER SUPPLY.SDR UALA2011111006134Circuit Card · faultyIDLE DISAGREE EICAS. REPLACED EEC DISCRETE CARD M590 AND RELAYS K141 & K434.SDR UALA2011110706026Power Cable · brokenESCAPE PATH LIGHTS ARE FLICKERING UNCOMMANDED ON RT SIDE OF FIRST CLASS. FOUND BROKEN PWR CABLE AT SEAT 10H. REPLACED CABLE PER MM. EEL OPS CHECK OKAY.SDR UALA2011110706043Battery · faultyFLOOR LEVEL EMERGENCY LIGHTS FLICKER ON AND OFF IN FLIGHT. RECHECK BATTERY REPLACED AT FWD RT CABIN, RESET CB'S AND TESTED EMERGENCY LIGHTING GOOD.SDR UALA2011110405992Battery · dischargedEEL LIGHTS IN FWD RIGHT SIDE OF CABIN ARE INOP. REPLACED BATTERY. CHECKS GOOD.SDR UALA2011110305949Circuit Breaker · trippedFUEL PUMP C/B POPPED, RTFL. LEFT TANK FWD FUEL BOOST PUMP LOW PRESS LIGHT ON WITH EICAS MSG ABOUT AN HOUR AFTER TAKEOFF, NOTICED CB G24 OUT, PER CREW. ACCOMPLISHED 3-PHASE VOLTAGE CHECK AT L FWD PUMP CONNECTOR D1550. 115 VAC ON PINS 2, 4, 6 CHECK GOOD. GROUSDR UALA2011110205930Switch · faultyL PACK INOP' LIGHT ON. EICAS MSG 'L PACK TEMP' DISPLAYED. OPERATED NORMAL AFTER 'STANDBY' SELECTED. CREW COMMENTS: 4000FT CLIMB L PACK TEMP EICAS & L PACK INOP LIGHTS. WENT OUT AFTER 30 SEC W-O PILOT ACTION. REPLACED ALTITUDE SWITCH.SDR UALA2011102405752Control Unit · out of toleranceL PACK INOP LIGHT ON. EICAS MSG 'L PACK TEMP' DISPLAYED. OPERATED NORM AFTER 'STANDBY' SELECTED. OK IN STANDBY. REPLACED LEFT PACK TEMP CONT'L. OPS CHECKED GOOD.SDR UALA2011101305564Actuator · leakingON WALK AROUND, FOUND HYDRAULIC FLUID AT THE OUTBOARD AILERON. REPLACED RT WING O/B AILERON ACTUATOR, OPS & LEAK CHECKED NORMAL. PERFORMED RII INSPECTION ON LT WING OUTBOARD AILERON PCU. PERFORMED OPS CHECK. NO DEFECTS FOUND.SDR UALA2011101105518Shutoff Valve · faultedRT HPSOV DURING TAXI-IN. LOCKED HPSOV CLOSED PER MEL. REPLACED HPSOV PER MM. LEAK CHECKED AND IDLE ENGINE OPS CHECKED GOOD.SDR UALA2011101105497Light · unsecureEMERGENCY LIGHT ON SIDE OF SEAT 1H NEEDS TO BE SECURED. RESECURED EMERGENCY LIGHT STRIP TO SEAT.SDR UALA2011101005488Isolation Valve · failedLEFT ISOLATION VALVE MESSAGE ILLUMINATED. ASSOCIATED BLEED ISOLATION VALVE EICAS MESSAGE NOT DISPLAYED. INTERMITTENT AT CRUISE ALTITUDE. REMOVED AND REPLACED LT ISOLATION VALVE IAW AMM, OPS CHECKED GOOD.SDR UALA2011100505380Snubber · brokenL1 DOOR SLIDE DEPLOYMENT GIRT BAR SNUBBER BROKEN. REMOVED & REPLACED SNUBBER ASSY IAW AMM. OPS CHECKED GOOD.SDR UALA2011100505369Cylinder · reads low46 MAN LIFE RAFT OUTBOARD PRESSURE BOTTLE READS 2900 PSI. REMOVED & REPLACED LIFE RAFT IAW MM 35-62-98.SDR UALA2011100305347Skin · puncturedRIGHT INBD MAIN FLAP UPPER SURFACE HAS SMALL PUNCTURE. LOCATED 32 INCHES FROM INBD END & 3.5 INCHES FWD OF T/E. REPAIRED PER SRM. RESTORED FINISH.SDR UALA2011100305346Pin · brokenSEAT 1H FWD EMERGENCY EXIT PATH LIGHT INOPERATIVE. FOUND PIN BROKEN. REPLACED PIN & OPS CHECKED GOOD.SDR UALA2011092605191Control Panel · faultyWX RADAR FAIL ANTENNA MESSAGE DISPLAYED ACCOMPLISHED WIRING CHECK FROM WX TRANSCEIVER TO PLANNER ASSY ALL CHECKS GOOD, REPLACED WX RADAR CONTROL PANEL M75, WX RADAR ASSY INCLUDING FLAT PLATE ANTENNA AND MOUNT M269, OPS CHECKED NORMAL ON THE GROUND.SDR UALA2011092105111Terminal Block · looseDURING ACP OF COA 618423 FOUND LOOSE TERMINAL BLOCK J5, WINDOW IS OUT. NR 1 LEFT WINDSHIELD REPLACED.SDR UALA2011092005091B-Nut · looseHYD FLUID LEAKING FROM RUDDER AREA, RIGHT SIDE. FOUND B-NUT LOOSE AND PACKING DETERIORATED ON LEFT SYS RUDDER PCU. REPLACED PACKING. LEAK CHECKED GOOD.SDR UALA2011091905053Scanner · malfunctionedWX RADAR INOPERATIVE. REPLACED WX RADAR SCANNER AND FLAT PLATE. WX RADAR WAS TOTALLY INOP WITH WX FAIL ANT DISPLAYED. AFTER REPLACEMENT, FAIL MSG WAS NOT DISPLAYED AND WX RADAR TESTS AND IS OPERATIONAL. CHECKS OKAY.SDR UALA2011082904642Control Unit · faultyON LANDING GOT SPOILER LIGHT & EICAS. REPEAT MAINT TEXT: SEE HISTORY ON RECENT HIT. NEED TO CHECK SCMS FOR POSSIBLE FAULT OR HISTORY INTERROGATION. FAULT HISTORY RECORDED INTERMITTENT APL 757, SCM, OR WIRING, SPOILER SHUTDOWN, LAST 4 LEGS. REPLACED SCM M53SDR UALA2011082204475O-Ring · leakingFLIGHT CREW NOTICED HYD LEAK JUST OUTBOARD OF LT BODY GEAR. FOUND ANTI SKID LINE LEAK AT UNION. REPLACED O-RING. DID OPERATIONAL TEST AND NO LEAKS FOUND.SDR UALA2011082204474Pin · missingRT SIDE FWD PIT GUIDE RAILS MISSING PINS. REPLACED MISSING PINS AND SPRING.SDR UALA2011081504305Light · missingSEAT 1H AFT EEL LIGHT MISSING. REPLACE SEAT 1H AFT EEL LIGHT, OPS CHECK GOOD.SDR UALA2011080404064Unknown · malfunctionedEQUIP OVHT LIGHT ILLUMINATED AFTER T/O. RAN CHECK LIST NOW NN STBY POSITION LIGHT OFF. "FWD EQT FLOW" EICAS MSG DISPLAYED WITH ASSOCIATED OVHT LIGHT ON. FAN AND VALVE OPERATED NORMAL ON GROUND. KOA NO TIME TO T/S FURTHER. -INF- :SUSPECT EXHAUST FAN NOT RUSDR UALA2011080404073Battery · overheatedMAIN BAT CHGR EICAS STATUS MSG. MAIN SHIPS BATTERY WAS OVERHEATING AND SHUTTING CHARGER. REPLACED MAIN SHIP BATTERY, OPS TEST OKAY.SDR UALA2011080204006Pump · faultyON DEP CTR HYD DEMAND EICAS ON FOR GEAR RETRACTON THEN AGAIN FLAPS 5-1. NOTED HISTORY FOR THIS PROBLEM. NEEDS MORE TROUBLESHOOTING. INF- SUSPECT ADP OUTPUT IS MARGINAL DURING HIGH DEMANDS AND MOST LIKELY WILL NEED REPLACED. -CQT- :ADP PCN IS 643-9064, ONSDR UALA2011080103990Satcom · inoperativeON STATUS PAGE CANNOT ERASE SATCOM HIGH GAIN. RESET SAT COM C-B'S AND SAT COM BITE TESTS OK MADE SAT COM RADIO CONTACT TO SAMC. ALL LOUD AND CLEAR. MADE SEVERAL CALLS TO SAMC, SYSTEM OPERATED NORMALLY. BUT AFTER ABOUT ONE HOUR ON THE GATE GOT "SATCOM HIGH SDR UALA2011080103937Fan · malfunctionedEQUIP OVERHEAT LIGHT ILLUMINATED AFTER TAKEOFF. RAN CHECK LIST NOW NN STBY POSITION LIGHT OFF. "FWD EQT FLOW" EICAS MSG DISPLAYED WITH ASSOCIATED OVHT LT ON. FAN AND VALVE OPERATED NORMAL ON GROUND. KOA, NO TIME TO T/S FURTHER. SUSPECT EXHAUST FAN NOT RUNNSDR UALA2011080103926Light · faultyPAX SEAT 1H CVR PLATE ON SIDE OF SET CAME OFF, HAVE IN COCKPIT. RE-SECURED AFT LIGHT ASSY, LIGHT INOP. REPLACED LT ASSY.SDR UALA2011072903902Shutoff Valve · faultedCENTER HYD DEM PUMP EICAS AND OVERHEAD PANEL PRESS LIGHT DISPLAYED DURING GEAR RETRACTION. TROUBLESHOT PER FIM. FOUND RT PRV FAULT ON ASBM. REPLACED PRV PER MM. RAN CENTER ACCOMPLISHED C1, C2 AND ADP SEPARATELY. CYCLED FLIGHT CONTROLS, GEAR DOORS. NO LOW P
Back to N668UA