N67052
Service difficulty reports · 79
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N67052' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N67052' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026101920449Valve · faultedFWD EQPT VALVE CAUTION MSG ON CLIMB OUT. TRIED TO CLOSE FWD EQUIP VAL PER FLIGHT MANUAL NON-NORMAL 2.20.45 VALVE AND MESSAGE WOULD NOT CLEAR. NEED TO MANUALLY CLOSE IAW MEL 2158S PROCEDURE 1. PERFORMED MAINTENANCE PROC ACCORDING MEL 2158S. ENSURED EXHAUST VALSDR CALA2026080418249Controller · faultedLT BLEED TRIPPED ON FINAL, NO EXISTING FAULTS FOUND IAW FIM 36-00 FAULT TREE 801, FOUND L A429 CTC 1 AND 2 IN FAULT HISTORY. REPLACED ASCTU REF AMM 36-11-22, OPS TEST PASSED. PERFORMED AIR SUPPLY DISTRIBUTION SYS OPS TEST IAW AMM 36-11-00-715-029-001, OPS TESDR CALA2026062917375Lamp · inoperativeDURING SAFA INSPECTION, REPORTED EMERGENCY LIGHT AT CEILING 21LK INOPERATIVE, CEILING AISLE EMERGENCY LAMP 21LK INOPERATIVE PER MEL 3351A. REPLACED THE LAMPS, CEILING AISLE EMER LAMP 21LK. REMAINED INOPERATIVE.SDR CALA2026050415931Sleeve · damagedDURING WALKAROUND FOUND #2 ENG INB THRUST REVERSER SLEEVE LINER DAMAGED 11 O CLOCK POSITION.AREA OF TRIM OUT 1FT X 2FT AT 11 O'CLOCK POSITON. ACCOMPLISHED INTERIM REPAIR PART 1 OF ECRA 7831-01423 REV D. REINSPECTED #2 ENG INB THRUST REVERSER SLEEVE LINER 11 SDR CALA2026042715732Oven · failedFORWARD GALLEY OVEN 109 ODOR POSSIBLY ELECTRICAL. PRECAUTIONARY C-B PULLED OPEN GALLEY OVEN 109. GALLEY OVEN REPLACED IAW AMM 25-31-00SDR CALA2026041915477Charger · inoperative47 TO 54 CENTER PROXIMITY EMERGENCY LIGHT INOPERATIVE. R & R BATTERY CHARGER, ITEM GOOD FOR SVC, IAW AMM 33-51-07-002-014-001.SDR CALA2026041715440Sensor · faultedRIGHT ENG ANALOG N2 STATUS MSG DISPLAYED DEBRIEFED CREW. CREW STATED AFTER TAKE OFF INTO CRUISE THEY NOTICED RIGHT ENG BLEED LIGHT OFF LIGHT ILLUMINATED. QRH WAS PERFORMED WITH NO HELP. SHORTLY AFTER RIGHT CTR FUEL PUMP LIGHT ILLUMINATED WITH NO OTHER ALERTS. SDR CALA2026033014920Paint · missingDURING INSPECTION FOUND MISSING PAINT ON NOSE RADOME. DURING PHASE 2 INSPECTION FOR LIGHTNING STRIKE. FOUND MISSING PAINT ON RADOME MEASURING APPROX. 1 SQ INCH. NO STRUCTURAL DAMAGE FOUND. APPLIED CLEAR TAPE TO EXPOSED AREA PER EC/RA 5350-02074. ACCOMPLISH ASDR CALA2026032014699Wire · damagedUPON INSTALLATION OF EE FORWARD CHILLER ADJACENT WIRE BUNDLE ARCHED FLAGGED SDR ON LOGPAGE. WIRE HARNESS BUNDLE DAMAGED BY CHILLER APPROXIMATELY BETWEEN STA 250 AND STA 287 AND RBL 50.00 AND RBL 75.00 IN EE BAY. DURING REPLACEMENT OF FORWARD CHILLER, CHILLER CSDR CALA2026022414036Lens · missing35D AND 38D PROXIMITY LIGHT LENS MISSING INSTALLED LENSES, ITEM GOOD FOR SVC, REF DWG 3351DD16252 PARTS USED: 29-3326-3-0013,QTY :2SDR CALA2025111411206Pitot Tube · faultedAUX PITOT CAUTION MESSAGE, FOUND C/B K16 TRIPPED, CAPTAIN'S PITOT PROBE HEAT, AUX PHASE B. C/B K16 (C01873) PITOT PROBE HT, AUX PHASE B T/S IAW FIM 30-31-00-815-814-001. R & R RT AUX PITOT PROBE IAW AMM 34-11-01.SDR CALA2025110210828Skin · crackedSLAT NR 11, NOSE SKIN BETWEEN OSS 871.63 AND OSS 833.74 CRACKED. PERFORMED REPAIR IAW EC/RA: 5743-02020. REMOVED FASTENERS, PERFORMED HOLE PROBE AND HFEC INSPECTIONS. INSTALLED THE REPAIR AND EXTERNAL REPAIR DOUBLER. PERFORMED THE REPAIR IAW EC/RA 5743-02SDR CALA2025110210822Stringer · corrodedSTRINGER 38L BTW BS 1417 - 1439 AT BULK CARGO BAY WITH CORROSION POINTS. PERFORMED INTERIM REPAIR IAW ECRA 5331-02173. REMOVED THE STRINGER, PERFORMED OPEN HOLE HFEC AND HFEC INSPECTIONS AT THE CUT-OUT EDGES, FINAL WEIGHT OF THE REPAIRS PARTS WAS 4.51LB IAWSDR CALA2025110210818Skin · damagedWHILE ACCOMPLISHING EC/RA 5760-01117 (AVO15691) THERMOGRAPH INSPECTIONS ON LT & RT OTBD AILERONS, FOUND INGRESS LIQUIDS ON THE RT OTBD AILERON INBOARD CAP, AT THE SPAR AREA. ALL STEPS OF THE ECRA: 5760-01117 (THERMOGRAPHIC INSPECTION) AND ECRA: 5760-01114 WESDR CALA2025090908647Lens · brokenSEAT 52D EMERGENCY LIGHT LENS BROKEN. R & R 52D EMERGENCY LIGHT REF AMM 33-51-10. OPS CHECK GOOD. A/C OKAY FOR SERVICE AT THIS TIME.SDR CALA2025081107547Warning Light · false activationRIGHT ENGINE BLEED OFF LIGHT THRU 10000. CLB PWR AND TAT +20. ASSOCIATED, OFF.DISCONNECTED CONNECTORS FROM N2 SPEED SENSOR ON NR 2 ENGINE IAW AMM 77-12-02, REMOVED LT & RT DCU IAW AMM. 31-63-06, DISCONNECTED CONNECTORS D5552P & D8032P. JUMPED PINS 3 & 4 ON P7SDR CALA2025072806985Sensor · faultedR ENG BLEED OFF ICAS WIT BLEED OFF LIGHT ON OVERHEAD ADDED PICS OF ASCTU RT ENG FAULT HISTORY PER CREW DEBRIEF, BLEED OFF AND PACK OFF WAS INTERMITTENT. REF HISTORY OF R BLEED OFF ON LEVEL OFF AND DESCEND PERFORM FIM 36-10 FT913 ALONG WITH PNEUMATIC HEALTH CHESDR CALA2025040803626Seal · faultyREMOVED L3 SLIDE SAFTEY PIN AND STOWED. FOR MAINTENANCE REINSTALLED L3 DOOR SLIDE SAFTEY PIN PER WORK CARD 64-2560-1-3801.PARTS USED: 99-5611-3-0025, QTY :1 CORRECT ENTRY SHOULD BE, "INSTALLED L3 SLIDE SAFTEY PIN FOR MAINTENANCE" CORRECT ENTRY SHOULD BE, "REMSDR CALA2025030502597Girt Bar · fodDOOR 4L NOT ARMING PROPERLY FOUND AND REMOVED DEBRIS FROM THE GIRT BAR LOCK. CHECKED ARM FUNCTION OKAY. REF AMM 25-66-01.SDR CALA2025021002251Relay · faultedGEAR DISAGREE AND GEAR DOOR ICAS MESSAGES AFTER TAKEOFF. MAIN G EAR STUC K IN TRANSIT.ACPD MAIN GEAR TILT SENSORS TARGET TEST FOR S-245/S-246/S-267/S-268 OK REF AMM 32-09-07-702-027-001 ALSO ACPD PSEU LDG GEAR SYSTEM TEST 1 & #2 OK REF FIM 32-09 FAULT TREE 80SDR CALA2024121201483Lens · brokenEMERGENCY LIGHTS - ESCAPE PATH LIGHT (SEAT-MOUNTED) OF POSITION 35D OUT OF POSITION. FOUND 35D EMERGENCY ESCAPE PATH LIGHT WITH RETAINER LENS BROKEN. REMOVED AND REPLACED 35D ESCAPE PATH LIGHT ASSY REF AMM TASK 33-51-10-962-104. OPS CHECK GOOD. ITEM OK FOR SVCSDR CALA2024102800937Warning Message · false indicationAILOCKOUT / ENG EEC MODE L AND R / ELEV FEEL / RUDDER RATIO ALL SEEN AFTER FO IAS FAIL.DUE TO THE RELATED FAULT MESSAGES IT'S NECESSARY TO PERFOM THESE TESTS AS FOLLOW: TEST RUDDER RATIO-CHANGER SYSTEM USING YSM BITE IAW AMM 27-21-00-715-001-002, EEC STATIC TESDR CALA2024102800935Gasket · faultedFO AIRSPEED INOP. AIR DATA RIGHT SELECTED ON FO SIDE AND AIRSPE ED RETURNED.DURING ACCOMPLISHMENT OF THE FIM 34-11-806 THE F/O PITOT PROBE WAS REMOVED REF AMM 34-11-01-004-304 AND FOUND HOSE PT PN:41073-9 SWAPPED WITH THE STATIC PORT S2 PN:421073-14 AFTER THASDR CALA2023061201838Fire Detector · unknownL ENG FIRE LP 1 STATUS MSG REF FIM 26-11 FAULT TREE 804 MESSAGE CLEARED WITH FIRE DETECTION DETECTION TEST GOOD. AIRCRAFT OK FOR SERVICE. TEST PER FIM. LOOP CONTINUITY CHECKS GOOD. CHECKED AND RESECURED LOOP CONNECTION POINTS, RAN ENGINE AT IDLE POWER, NO FAULSDR CALA2023051101454Unknown · odorVERY STRONG FUEL/OIL SMELL IN AFT GALLEY COFIRMED BY IRO SOURCE UNKNOWN ACP''D CONDITIONAL INSPECTION PER AMM 05-51-56-202 RAN ENGINES, RAN PACKS, CYCLED ALL PACK TEMPS. RAN ALL AFT GLLY OVENS. NO FUEL SMELL NOTED THRU CABIN OR IN AFT GLLY.SDR CALA2023020100295None · missingPDA 3 1 STATIC WIC MISSING FROM LEFT HORIZONTAL STAB OUTBOARD REQ CDL FOR 1 DISCHARGER MISSING LEFT HORIZONTAL STAB AC OK FOR SERVICE APPROVED CDL 23B REPLACED MISSING STATIC WICK ON LEFT HORIZONTAL STAB TIP AS PER AMM 23-61-01SDR CALA2022010700040Filter · dirtyDISTRIBUTION SMOKE FROM AIR CONDITIONING OUTLETS; CONTINUED WITH BOTH UTILITY BUSES OFF. (REF CHAPTER 24 FOR FAULT CODE DIAGRAM) OILY RAG ODOR ROW 27. DISSIPATED WITH LEFT PACK OFF. CONTD W/ LE FT PACK OFF PER DD/TOMC TROUBLESHOT PER FIM 21-00 TASK 802. REMOVESDR CALA2021112202145None · nonePAX O2 SWITCH INADVERT ANTLEY PUSHED. ALL MASKS DEPLOYED REPACKED ALL DEPLOYED MASKS IN THE CABIN AS REQUIRED, REF. AMM. 35-21-10, 11, 12, 13, 14, AND 15. ADD EMP:U241740,U233291,U330713SDR CALA2021021900190Battery Pack · no testEMERGENCY BATTERY NEEDS REPLACED DUE TO BATTERY NOT HOLDING CHARGE. LOCATED ROW 24BA. REMOVED AND REPLACED EMERGENCY BATTERY AT BS 988, REF AMM 33-51- 07-002-014-001; 33-51-07-404-018-001. (MFG PN AD-D717-01-100) WPB AERSALE ROW, V931306 ADD EMP:V931306.SDR CALA2019092801650Charger · inoperativeSUPPORT TASK CABIN SEAT 22 TO 27 EMERGENCY PATH LIGHTING FOUND DIM.REFER NR L/P:9131288 M732 BATTERY CHARGER AND BATTERY REPLACED AND OP TEST NORMAL AS PER AMM 33-51-07 ADD EMP: IDT INSP APPROVEDSDR CALA2019092801649Battery · dischargedSUPPORT TASK G8 GALLEY EXIT SIGN & L4 DOOR LIGHT FOUND DIM.REFER NR L/P:9131287 M739 BATTERY AND CHARGER REPLACED, EMERGENCY LIGHT TEST C/OUT NORMAL AS PER AMM 33-51-07 ADD EMP: IDT INSP APPROVEDSDR CALA2019040500523Tube · brokenC HYD QTY EICAS LT. PUMPS SELECT OFF. QTY STABLE AT .27 REMOVED (UPPER) R/WING ACCESS PANEL # 651PT TO F.O.M. REMOVED (UPPER) R/WING ACCESS PANEL # 651NT TO F.O.M. REMOVED (LOWER) R/WING ACCESS PANEL # 652HB TO F.O.M. DISCOVERED HYD. LEAK AT HYD. TUBING B-NUT SDR CALA2018121602586Battery Pack · inoperative(REFERNCE SUPPORT TASK64-3350-1-7100) EXTERIOR EMERGENCY LIGHTS AT MID DOOR AND AFT ENTRY DOOR DO NOT TURN ON. REF VTSAA N/R 004 1583. TROUBLESHOOT MID ENTRY AND AFT ENTRY DOOR EXTERIOR EMERGENCY LIG HTS. REPLACED 1EA FUSE AT POWER SUPPLY (M6759) FOR MID ENTRYSDR CALA2018121402581Battery Pack · inoperative(REFERENCE SUPPORT TASK 64-3350-1-7100) AFT SERVICE DOOR AND AFT ENTRY DOOR EMERGENCY LIGHTS DO NOT COME ON. REF ST-SAA NR 00415 82. REMOVED AND REPLACED BATTERY PACK FOR POWER SUPPLY M1210, OP CHE CK GOOD IN REF TO B767-4 AMM 33-51-07-022-005-001 P/N AD-0717-SDR CALA2018041601169Wire · brokenRIGHT EMERGENCY LIGHTS IN COACH ON, FOUND BLUE WIRE OF SENSOR S222 OF THE RT CENTER DOOR BROKEN. SPLICED 2 FT FROM DOOR SENSOR S222 IAW SWPM 20-10-13, AND 20-30-12. SYSTEM OPS CHECKED GOOD.SDR CALA2018030500836Skin · crackedSKIN CRACK FOUND JUST AFT OF BS 1654, STRINGER 13AL. VERIFIED CRACK NDT MANUAL PART6 51-00-19. FABRICATED A DOUBLER AND FILLER IAW SRM 53-80-0, AND SRM 53-80-01 REPAIR 7. INSTALLED THE REPAIR DOUBLER AND FILLER.SDR CALA2018030100833Skin · crackedSKIN CRACK FOUND JUST AFT OF BS 1654, STRINGER 13AR. CUT OUT AND REMOVED DAMAGE IAW SRM 53-80-01, STEP 4E. FABRICATED -1 DOUBLER, DRILLED, COUNTERSUNKED, DEBURRED, ALODINE IAW SRM 53-80-01 REPAIR 7. INSTALLED THE REPAIR.SDR CALA2018012900392Flag · out of adjustDOOR 4R YELLOW TAB ONLY COMES UP ONE THIRD NORMAL HEIGHT WHEN ARMED. ADJUSTED AND REPOSITIONED YELLOW "EMERGENCY ONLY" TAB. OK TO CONTINUE.SDR CALA2017111704088Stringer · damagedSTRINGER 39L DAMAGED 6.75 INCHES FORWARD OF BS 1439. REPLACED THE STRINGER IAW SRM 53-00-03, REPAIR 2.SDR CALA2017111704086Stringer · damagedSTRINGER 38R DAMAGED 5.5 INCHES FORWARD OF BS 1439. REPLACED THE STRINGER IAW SRM 53-00-03, REPAIR 2.SDR CALA2017111704090Stringer · damagedSTRINGER 37L DAMAGED 9.75 INCHES FORWARD OF BS 1439. REPLACED THE STRINGER IAW SRM 53-00-03, REPAIR 2.SDR CALA2017111704089Stringer · damagedSTRINGER 38L DAMAGED 8 INCHES FORWARD OF BS 1439. REPLACED THE STRINGER IAW SRM 53-00-03 REPAIR 2.SDR CALA2017111704087Stringer · damagedSTRINGER 39R DAMAGED 6 INCHES FORWARD OF BS 1439. FABRICATED A NEW STRINGER, ALODINED AND PRIMED IAW SRM 53-00-03, REPAIR 2. INSTALLED THE STRINGER IAW SRM 53-00-03, REPAIR 2.SDR CALA2017081102597Oven · smokeOVEN 712 20 MIN INTO COOK CYCLE BEGAN SMOKING SO OVEN WAS TURNED OFF RESET CB OPS OK NOW ADD EMP:NSDR CALA2017080802538Door · out of sequenceL4 DOOR WILL NOT ARM. FOUND DOOR OUT OF SEQUENCE, CYCLED FROM OUTSIDE. SLIDE FOR L4 DOOR ARMS NORMALLY.SDR CALA2017022400476Light · inoperativeBULB BURNED OUT ON OVERHEAD PANEL-EMERG EXIT UNARMED LT. RELAMPED CKS OK.SDR CALA2016111400900Floorbeam · corrodedCABIN BS 303 LBL 11-55 FLOORBEAM SUPPORT SURFACE FOUND CORROSION. CABIN AT STA 303 LBL 11 - LBL 55 FLOORBEAM UPPER CHORD. CORROSION REMOVED AS PER SRM 51-10-02, BLEND OUT AREA DEPTH: 0.035" (ORG THK: 0.090") X WIDTH: 1" X LENGTH: 5" OUT OF SRM 53-00-51 ALLOWABSDR CALA2014082701167Power Supply · inoperativeR4 EMER LIGHTS FAILED LIGHT TEST. R & R R4 DOOR EMER LIGHT POWER SUPPLY IAW 33-51-07.SDR CALA2014082701166Charger · inoperativeEMER LIGHT BY L4 & R4 DOORS STAY ON. R & R EMER POWER BATTERY CHARGER BY R4 FLIGHT ATTENDANT SEAT. OPERATIONS CHECKED GOOD IAW AMM 33-51-07.SDR CALA2014032800402Battery Pack · failedM732 BATTERY PACK TEST FAILED. M732 BATTERY PACK REPLACED & TESTED NORMAL IAW AMM 33-51-07 & AMM 33-51-00.
Back to N67052