What was found
C HYD QTY EICAS LT. PUMPS SELECT OFF. QTY STABLE AT .27 REMOVED (UPPER) R/WING ACCESS PANEL # 651PT TO F.O.M. REMOVED (UPPER) R/WING ACCESS PANEL # 651NT TO F.O.M. REMOVED (LOWER) R/WING ACCESS PANEL # 652HB TO F.O.M. DISCOVERED HYD. LEAK AT HYD. TUBING B-NUT CONNECTION LOCATED UNDER R/WING (UPPER) ACCESS PANEL # 651NT. (LOCATION HAS BEEN MARKED WITH RED TAPE). AMM TASK # 12-12-01. RE-SERVICED HYD. SYSTEM FLUID QUANTITY BACK UP TO 90% IRW 767-4 T/S LEAK IN THE RIGHT LANDING GEAR EXTENTION & RETRACT SYSTEM, FOUND TO BE LEAKING FROM A CRACK IN TUBE ASSY. P/N 272T1200-1432. REMOVED TUBE P/N 272T1200-1432 & TUBE 272T1200-1434 REF. I.P.C. 32-32-56-03 ITEMS 171 & 172. ADD EMP:U222091 ADDITIONAL EMP. WORK PERFORMED. REMOVED 2 EA HYD TUBE ASSY - LANDING GEAR, UP IPC 32-32-56-03 ITEM 271 &