N671AE
Service difficulty reports · 130
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N671AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N671AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA20220404001Lamp · inoperativeGALLEY CEILING EMERGENCY LIGHT INOP-C/A-RAR GALLEY CEILING EMERGENCY LAMP IAW AMM 33-50-09-000-801-A AND 33-50-09-400-801-A. OPS CHECK GOOD. END.SDR SIMA20220226002Not Reported · not reportedSERVICE DOOR EMERGENCY LIGHT INOP-C/A-RAR SERVICE DOOR EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC GOOD. END.SDR SIMA20211222003None · nonePASSENGER SEAT 15A AND 16A EMERGENCY LIGHT FLOOR POWER STRIP WIRE BORKEN.-C/A-RAR EMERGENCY FLOOR PROXIMITY STRIP LIGHT IAW AMM 33-50-12 OPC GOODSDR SIMA202108154001Lamp · inoperativeGALLEY EMERGENCY LIGHT INOP. R & R GALLEY EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-09-000-801-A AND 33-50-09-400-801-A. OPC GOOD. END.SDR SIMA20210618002Inverter · inoperativeEMERGENCY INTERIOR LIGHT ADJ TO RH EMERGENCY EXIT INOP-C/A-REF TURNOVER, COMPLETED RAR OF #5 EMERG LIGHTS INVERTER IAW AMM 33-50-11. OPC GOOD.SDR SIMA20210225002Flashlight Assy · brokenAFT CABIN EMERGENCY FLASHLIGHT HOLDER HAD BROKEN CLIP-C/A-R & R AFT CABIN EMERGENCY FLASHLIGHT HOLDER ASSEMBLY IAW EMB AMM 33-50-16-000-801-A AND 33-50-16-400-801-A. OPS CHECK GOOD.SDR SIMA20210113001Light · inoperativeAFT RT OVERWING EMERGENCY LIGHT INOPERABLE. C/A: R & R AFT RT OVERWING EMERGENCY LIGHT ASSEMBLY OPERATIONS CHECK GOOD, IAW AMM 33-50-10.SDR SIMA20201217001Bulb · inoperativeRT UPPER EMERGENCY EXIT LIGHT INOPERABLE. C/A: R & R RT UPPER EMERGENCY LIGHT BULB, IAW EMB 145 AMM 33-50-10. OPERATIONS CHECK GOOD. NO DEFECTS NOTED.SDR SIMA20201128004Lamp · inoperativeRT OVERWING EMERGENCY LIGHT INOPERABLE. C/A: R & R RT OVERWING EMERGENCY LIGHT LAMP, IAW EMB AMM TASK 33-50-07-000-801-A AND 33-50-07-400-801-A. OPERATIONS CHECK GOOD.SDR SIMA202007232002Light · inoperativeFOUND RT WING EMERGENCY LIGHT INOPERATIVE DURING PS-1 CHECK. REMOVED AND INSTALLED A NEW RT WING EMERGENCY LIGHT IAW AMM 33-50-10. OPS CHECKED GOOD. NO DEFECTS NOTED.SDR SIMA2020031614003Light · inoperativeRH OVERWING EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED RH OVERWING EMERGENCY LIGHT IAW EMB AMM 33-50-07-000-801-A AND 33-50-07-400-801-A. OPS CHECKED GOOD. END.SDR SIMA202003110001Light · inoperativeR/H WING EMERGENCY LIGHT INOP-C/A-RAR R/H WING EMERGENCY LIGHT IAW EMB 145 AMM 33-50-10. OPS CHECK GOOD. NO FURTHER DEFECTS NOTED.SDR SIMA202003032005Transducer · failedH.S. REJECTED T/O (80 KTS) DUE E2 A/I FAIL ON T.O. ROLL-C/A-RRMOVED AND REPLACED ENGINE #2 ANTI-ICING PRESSURE TRANDUCER IAW EMB145 AMM 30-21-06 LEAK/ OPS CHECK GOODSDR SIMA202002132004Anti-Ice Valve · failedE1 A/ICE FAIL MESSAGE DURING CLIMB. RAN CHECHLIST, BUT MESSAGE REMAINED AND VALVE WOULD NOT OPEN WITH OVERRIDE NOB IN ALL. ALSO GOT AN ENG A/I OVERPRESS ADVISORY MESSAGE.-C/A-DEFFERED PER MEL 30-11 "M" PROCEDURES COMPLIED WITH. REMOVED AND REPLACED E1 ENG PRESDR SIMA201912275002Battery Pack · inoperativeDURING PS-1 CHECK, FOUND EMERGENCY LIGHT INOPERATIVE BETWEEN 12A AND 9A. REMOVED AND REPLACED THE NR 3 BATTERY POWER SUPPLY AND BATTERY IAW AMM 33-50-04, OPS-CHECKED GOOD. NO FURTHER DEFECTS NOTED.SDR SIMA201912274001Battery Pack · dischargedFOUND EMERGENCY LIGHT BATTERY PACKS NR 2 AND 3 LOW, LIGHTS SHUT OFF AFTER APPOX 10 SECONDS. REMOVED AND REPLACED THE NR 2 BATTERY. OPS CHECKED GOOD IAW AMM 33-50-04. REMOVED AND REPLACED NR 3 BATTERY, OPS CHECKED GOOD IAW AMM 33-50-04.SDR SIMA201912274003Bulb · inoperativeLEFT FORWARD LOWER FAIRING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE BULB IAW AMM 33-50-10.SDR SIMA201912274002Light · inoperativeFLOOR PROXIMITY STRIP NR 1 AFT SECTION INOPERATIVE. REMOVED AND REPLACED FLOOR PROXIMITY STRIP LIGHT IAW AMM 33-50-12. OPS CHECKED GOOD, NO FURTHER DEFECTS NOTED.SDR SIMA201912032003Battery Pack · inoperativeDURING PS-1 CHECK FOUND MULTIPLE EMERGENCY LIGHTS OUT NEAR CENTER FUSELAGE.-C/A-REMOVED AND REPLACED #3 EMERGENCY LIGHT BATTERY AND CHARGER ASSEMBLY IAW EMB 145 W/C 33-700-19. OPS CHECK GOOD. BATTERY CHARGER ASSY P/N 11-0049 S/N 12788SDR SIMA201911143010Unknown · smokeON TAXI OUT AFTER SWITCHING PACK 1 BACK ON, COCKPIT FILLED WITH SMOKE. AFTER SWITCHING PACK 1 BACK OFF SMOKE DISSIPATED-C/A-PERFORMED FIM TASK PROCEDURES EMB 145 FIM 21-20-00. RAN PACK 1 AND PACK 2 AND PERFORMED ALL VISUAL INSPECTIONS. NO DISCREPANCIES NOTED. SDR SIMA201911087004Light · inoperativeSERVICE DOOR EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED SERVICE DOOR EMERGENCY LIGHT IAW AMM TASK 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC GOOD. END.SDR SIMA201910086010Wire · broken3EA WIRES BROKEN ON EMERGENCY LIGHT STRIP FLOOR CONNECTIONS-C/A-REPAIRED 3EA WIRES AT FLOOR PAELS 261BF AND 251FF IAW SWPM 20-21-00. OPS CHK GOODSDR SIMA201910086009Wire · broken1EA BROKEN WIRE ON EMERGENCY LIGHT STRIP AT FLOOR PANEL 251BF-C/A-REPAIRED 1EA WIRES AT FLOOR PANEL 251BF IAW SWPM 20-21-00. OPS CHK GOODSDR SIMA201910083010Shunt · gougedFRAME 80 AFT SIDE AT APU SHUNT CONNECTION IS GOUGED (FRAME REINFORCEMENT)-C/A-REMOVED AND REPLACED REINFORCEMENT IAW SRM 53-32-04, GPM17-13 AND SRM 51-40-02.SDR SIMA201910083009Shear Tie · corrodedSSI 53-30-48 FR 65 SHEAR CLIP IS CORRODED AT CARGO DOOR SILL AND ABOVE GUIDE PLATE-C/A-REMOVED AND INSTELLED SERVICEABLE SECTION OF FRAME 65 SHEAR IAW EMB 145 SRM 53-31-04.SDR SIMA201910083008Rib · crackedLH WING RIB 21 IS CRACKED INSIDE PANEL 551CB.-C/A-REPAIRED LH WING RIB 21 INSIDE PANEL 551CB IAW EMB 145 SRM 57-20-07, ITEM #4.SDR SIMA201910083007Door Sill · corrodedCARGO DOOR LOWER SILL IS CORRODED-C/A-REMOVED AND REPLACED CARGO DOOR LOWER SILL IAW EMB-145 SRM 51-40-02.SDR SIMA201910083006Stringer · crackedSTGR 6R CRACKED AT FR 13-C/A-REMOVED AND INSTALLED NEW STRINGER 6R AT FRAME 13 IAW EMB 145 SRM 51-40-02.SDR SIMA201910083005Floor Support · crackedLH OMEGA BEAM OUTBD SUPPORT IS CRACKED AT PREVIOUS REPAIR AT FR 47-C/A-REMOVED AND REPLACED L/H OMEGA OUTBD SUPPORT AT FR 47 IAW EMB 145 SRM 53-23-02 AND SRM 51-40-02SDR SIMA201910083004Stop Fitting · damagedCARGO DOOR FWD CONTINUOS STOP IS BENT AND CRACKED AT LOWER END-C/A-REMOVED AND INSTALLED NEW CARGO DOOR FWD CONTINUOS STOP IAW EMB 145 SRM 51-40-02SDR SIMA201910083003Rib · crackedRH WING RIB 21 IS CRACKED INSIDE PANEL 651CB. REPAIRED RH WING RIB 21 INSIDE PANEL 651CB IAW EMB 145 SRM 57-20-07, ITEM #4SDR SIMA201910083011Floor Support · corrodedSSI 53-20-11 LH OMEGA BEAM SIDEWALL CORRODED AT FR 29. REPAIRED LH OMEGA BEAM SIDEWALL AT FR 29 IAW ENVOY ERS-EM-53MR-3903SDR SIMA201910083012Frame · gougedFR 68 Z FRAME IS GOUGED AROUND 4 SCREW HOLES RH SIDE LOWER END-C/A-REMOVED AND REPLACED GOUGED FR 68 Z FRAME IAW EMB 145 SRM 51-40-02.SDR SIMA201910083002Rib · crackedLEFT ELEVATOR INBOARD HINGE CUTOUT INBOARD NOSE RIB IS CRACKED -C/A-REMOVED AND INSTALLED NEW INBD NOSE RIB ON THE LEFT ELEVATOR INBOARD HINGE CUTOUT IAW EMB 145 SRM 51-40-02 AND 51-20-03.SDR SIMA201910083001Door Frame · corrodedCARGO DOOR LOWER FRAME IS CORRODED AROUND 2 SCREW HOLES AT FWD END.-C/A-REMOVED AND INSTALLED NEW CARGO DOOR LOWER FRAME IAW EMB 145 SRM 51-20-03, 51-40-06 AND 51-40-02.SDR SIMA20190721001Ecu · failedAFTER TAKE OFF UPON RETRACTING THE FLAPS, WE GOT FLAPS FAIL MESSAGE ON THE EICAS. FLAPS DID NOT RETRACT AND STAYED AT 9*. WE COMPLIED WITH CHECKLIST AND LANDED IN MIA. C/A-REMOVE AND REPLACE FECU IAW AMM 27-53-02. OPS CHECK GOOD.SDR SIMA201809187005Inverter · inoperativeEMEREGENCY EXIT LIGHTED SIGN ON BACKSIDE OF AFT CALLEY (FACING THE SEATS) INOP. REMOVED AND REPLACED NR 2 DC/AC INVERTER IAW AMM 33-50-11 AND EMERGENCY LIGHTS OPS CHECK GOO IAW AMM 33-50-00-700-801.SDR SIMA201808275002Generator · malfunctionedNR 3 GENERATOR OFF BUSS DURING TAKEOFF ROLL. REMOVED AND REPLACED THE NR 3 GENERATOR IAW WC 24-800-00, OP CHECKED GOOD AND LEAK CHECKED GOOD.SDR SIMA2018082019001Control Unit · failedFLAP FAIL AFTER TAKE OFF STUCK AT 9. CMC HAD MULTIPLE OCURRENCES OF DRIVE SENSOR FAIL. HAD ONE OCURRENCE OF FLAP RT TRANSMISSION FAIL. TROUBLESHOT IAW FIM 27-51-00-810-817-A, AND FIM 27-51-00-810-801-A. REMOVED AND REPLACED THE FECU IAW AMM 27-53-02. OPS CHSDR SIMA201808032001Lamp · inoperativeEMERGENCY LIGHT AT THE SERVICE DOOR WAS INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT LAMP IAW AMM 33-50-10. OPS CHECKED GOOD.SDR SIMA20180224002Charger · failedBOTH AFT OVERWING EMERGENCY LIGHTS FAILED TO ILLUMINATE. COMPLIED WITH FIM 33-50-00. REMOVED AND REPLACED THE NR 4 EMERGENCY LIGHT BATTERY AND CHARGER IAW 33-50-04. OPS CHECKED GOOD IAW AMM 33-50-04.SDR SIMA20180217012Charger · inoperativeBOTH AFT OVERWING EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED THE BATTERY AND CHARGER IAW W/C 33-700-19. OPS CHECKED GOOD.SDR SIMA20180215005Battery Pack · inoperativeSEVERAL EMERGENCY LIGHTS FOUND INOPERATIVE, LT AND RT EXTERNAL OVERWING. REMOVED AND REPLACED THE NR 4 BATTERY, PERFOMED AN OPS CHECK IAW 33-700-17. OPS CHECKED GOOD.SDR SIMA20180215004Contactor · dirtyAFT GALLEY EMERGENCY EXIT SIGN INOPERATIVE. REMOVED AND CLEANED THE CONTACTORS IAW GENERAL MAINTENANCE, OPS CHECKED GOOD.SDR SIMA20180202003Power Supply · failedLEFT AND RIGHT OVERWING EXTERNAL EMERGENCY LIGHTS FAILED TO ILLUMINATE. TROUBLESHOT IAW WM 33-50-50, AND R 7 R THE NR 4 EPSU IAW AMM 30-50-04. OPS CHECKED GOOD. BATTERY CHARGER ASSY.SDR SIMA20180202002Wire Harness · failedRECEIVED A LANDING GEAR AIR/GND FAIL CAUTION MESSAGE DURING CLIMBOUT. COULD NOT BRING GEAR UP. MESSAGE EXTINGUISHED 2 MINUTES LATER. BROUGHT GEAR UP. LANDED BACK AT DEPARTURE, GEAR DOWN. REMOVED AND REPLACED NLG AIR /GROUND WOW PROXIMITY SENSOR NR 2 IAW AMM 32SDR SIMA20180107003Charger · failedBOTH AFT OVERWING EMERGENCY LIGHTS ARE INOPERATIVE. REMOVED AND REPLACED THE NR 4 EMERGENCY LIGHT CHARGER AND BATTERY ASSY, OPS CHECKED BAD IAW AMM 33-50-04.SDR SIMA20171214002Fuse · failedLH AND RH AFT OVERWING EMERGENCY LIGHTS INOP.-C/A-T/S PER FIM 33-50-00-810-804A. FOUND #4 EMERGENCY BATTERY POWER SUPPLY FUSE F1 INOP. REMOVED AND REPLACED #4 EMERGENCY BATTERY POWER SUPPLY FUSE F1 IAW CMM 25-60-03. OPS CHECK GOOD AT THIS TIME.SDR SIMA20171108006Power Supply · inoperativeBOTH OVERWING EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED THE POWER SUPPLY IAW AMM 33-50-04. OPS GOOD.SDR SIMA20171101001Battery · dischargedLT AND RT OVERWING EMERGENCY LIGHT INOP. REPLACED NR 4 EMERGENCY BATTERY AND BATTERY POWER SUPPLY IAW AMM 33-50-04 OPS GOOD. BATTERY CHARGER ASSY P/N 11-0049 S/N 19591.
Back to N671AE