N671AE
Service difficulty reports · 130
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N671AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N671AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA20170926002Charger · failedFOUND O/W RT AND O/W LT EXTERIOR EMERGENCY LAMPS INOP. REMOVED AND REPLACED BATTERY POWER SUPPLY IAW AMM 33-50-04 OPS CHECK GOOD. EMERGENCY LIGHTING BATTERY P/N 2013-1A S/N 73813.SDR SIMA20170831001Sensor · failedDURING CLIMB, RETRACTED FLAPS TO 0 DEGREES ON THE SELECTOR. RECIEVED FLAP FAIL ON EICAS. FLAPS INDICATED 9 DEGREES. RETURNED FOR LANDING AND LANDED. REMOVED AND REPLACED THE RT VELOCITY SENSOR IAW AMM 27-51-12. REMOVED AND REPLACED FLAP CONTROL UNIT IAW AMSDR SIMA20170625002Controller · failedCLIMBING TRHROUGHT 15000 FT, THE CABIN RATE BEGAN TO FLUCTUATE, BETWEEN 2000 AND -2000 FPM, CABIN ALTITUDE DISPLAY, FOUR ORANGE DASHES. SELETED MANUAL MODE IAW AOM, VOL 1 PROCEDURES, COULD NOT CONTROL PRESSURIZATION IN MANUAL MODE BOTH IN AIR AND ON GROUND.SDR SIMA20170616004Charger · failedALL EMERGENCY LIGHTS THAT ARE POWER BY EMERGENCY BATTERY NR 1 DO NOT TURN ON. REMOVED AND REPLACED EMERGENCY BATTERY AND CHARGER IAW WC 33-700-19SDR SIMA20170612002Stringer · chafedSTRINGER 2L IS CHAFED BETWEEN FRAMES 20 - 21. REMOVED AND REPLACED THE STRINGER IAW SRM 51-40-02.SDR SIMA20170606009Floor Support · corrodedLEFT OMEGA BEAM IS CORRODED BETWEEN FRAMES 58 AND 59. REPAIRED THE OMEGA BEAM IAW ERS-EM-53MR-2773.SDR SIMA20170606008Channel · corrodedFR 65 CHANNEL IS CORRODED AROUND SCREW HOLE AT STRINGER 14L. REPAIRED THE CHANNEL IAW ERS-EM-53MR-2761.SDR SIMA20170605002Wire · brokenLEFT EMERGENCY LIGHT NR 4 WIRES ARE BROKEN. REMOVED AND REPLACED THE EMERGENCY LIGHT IAW AMM 33-50-12SDR SIMA20170604005Frame · crackedFRAME 73 CRACKED AT STRINGER 17R-C/A-REMOVED AND REPLACED FR 73 AT STRINGER 17R IAW EMB 145 SRM 51-40-02SDR SIMA20170604007Door Sill · corrodedSERVICE DOOR CUTOUT LOWER CENTER SILL CORRODED. REPAIRED SERVICE DOOR CUTOUT LOWER CENTER SILL IAW 53-21-02, AND 51-20-03SDR SIMA20170604006Skin · crackedLEFT AFT FUSELAGE FRAME 75 HAS A SKIN CRACK ABOVE STRINGER 2L. PERFORMED A PERMANENT REPAIR IAW SRM 53-31-01SDR SIMA20170603004Structure · corrodedLAVATORY BUCKET IS CORRODED AROUND TOILET WASTE VALVE. REMOVED AND REPLACED TOILET WASTE VALVE SUPPORT BUCKET IAW SRM 51-40-02SDR SIMA20170509001Manifold · no testNOSE WHEEL STEERING MANIFOLD FAILED TO TEST IAW AMM 32-50-04 STEP J1E. SERVO VALVE CURRENT MUST BE 0 +- O.5 MILLIAMPS. CURRENT READS OVER 2 MILLIAMPS. REPLACE MANIFOLD. REMOVED AND REPLACED NOSE WHEEL STEERING MANIFOLD IAW AMM 32-50-04. INSTALLED NEW ZERO SDR SIMA20170303004Wire · brokenFLOOR EMERGENCY LIGHT NR 8, HAS A BROKEN WIRE SPLICE. REMOVED AND REPLACED EMERGENCY LIGHT IAW AMM 33-50-12. OPS CHECKED GOOD.SDR SIMA20170303003Reflector · corrodedPILOT`S FLASHLIGHT LIGHT REFLECTOR CORRODED. REMOVED AND REPLACED THE FLASHLIGHT ASSY IAW AMM 33-50-16.SDR SIMA20150314002Power Supply · inoperativeEMERGENCY LIGHTS INOPERATIVE IN GALLEY, ROW 7 OVERHEAD & 3 FWD AISLE STRIPS. R & R BATTERY POWER SUPPLY NR 2, BATTERY AND CHARGER, IAW AMM 33-50-04. OPERATIONAL TEST GOOD.SDR SIMA20150304003Power Supply · inoperativeLEFT & RT OVERWING PANEL EXIT LIGHTS DO NOT COME ON. R & R NR 4 BATTERY POWER SUPPLY, CHARGER & NR 4 BATTERY ASSEMBLY IAW AMM 33-50-04. EMER LIGHTING OPERATIONAL CHECKED GOOD.SDR SIMA20150304002Light · inoperativeEMERGENCY LAMP ON CEILING PANEL 263ALC WILL NOT COME ON. R & R EMER LAMP ON CEILING PANEL 263ALC IAW AMM 33-50-08. OPERATIONAL CHECK PERFORMED & FOUND SATISFACTORY.SDR SIMA20150219008Frame · chafedFUSELAGE FRAME 60 CHAFED AT STRINGER 05L.L PERFORMED ERS-EM-53MR-1098 FOUND TO BE ACCEPTED AS IS.SDR SIMA20150219007Rib · gougedLEFT WING INBD RIB GOUGED AFT OF THE MLG UPLOCK BOX. PERFORMED ERS-EM-57MR-388 FOUND TO BE ACCEPTED AS IS.SDR SIMA20150219006Frame · chafedGALLEY AREA FRAME 19 CHAFED AT STRINGER 03R. PERFORMED ERS-EM-53MR-1099 FOUND TO BE ACCEPTED AS IS.SDR SIMA20150219009Structure · corrodedSERVICE DOOR LOWER FWD & AFT SCREW HOLES ARE CORRODED WHERE LINER ATTACHES. PERFORMED ERS-EM-52MR-294 FOUND TO BE ACCEPTED AS IS.SDR SIMA20150218004Wire · nickedFLOOR PROX LIGHT WIRE INSULATION NICKED AT FRAME 49. REPAIRED THE FLOOR PROX LIGHT WIRE INSULATION AT FRAME 49 IAW SWPM 20-21-00.SDR SIMA20150218003Wire · nickedCABIN MOST AFT FLOOR PROXIMITY LIGHT WIRE INSULATION NICKED AT LT OMEGA BEAM. REPAIRED THE CABIN MOST AFT FLOOR PROXIMITY LIGHT WIRE INSULATION AT LT OMEGA BEAM IAW SWPM 20-21-00.SDR SIMA20150215003Skin · scratchedFUSELAGE SKIN SCRATCHED FRAME 16 - 17, STRINGER 12R. PERFORMED ERS-EM-53MR-1087 FOUND TO BE ACCEPTED AS IS.SDR SIMA20150215002Skin · gougedSERVICE DOOR FWD INNER SKIN GOUGED AT LOWER CORNER. PERFORMED ERS-EM-52MR-292 FOUND TO BE ACCEPTED AS IS.SDR SIMA20150206008Support · crackedRIGHT OMEGA BEAM INBD SUPPORT CRACKED BETWEEN FRAME 47 - 48. REMOVED & INSTALLED SERVICEABLE SUPPORTS FOR RT OMEGA BEAM INBD SIDE BETWEEN FRAME 46 - 50 OVER THE WING BOX IAW SRM 51-40-02 & SRM 53-23-02.SDR SIMA20150206009Support · crackedRIGHT OMEGA BEAM OTBD SUPPORT CRACKED BETWEEN FRAME 47 - 48. REMOVED & INSTALLED SERVICEABLE LONGER SUPPORT FOR RT OMEGA BEAM OTBD SIDE BETWEEN FRAME 46 - 50 OVER THE WING BOX IAW SRM 51-40-02 & SRM 53-23-02.SDR SIMA20150206010Light · brokenEMERGENCY LIGHT STRIP ON LT FLOOR EXTRUSION NR 1 WIRES BROKEN. R & R EMER LIGHT STRIP ON LT FLOOR EXTRUSION 1 IAW AMM-33-50-12.SDR SIMA20150115007Light · shortedDURING PS1 INSPECTION FOUND BOTH OVERWING AFT EMER LIGHT INOPERATIVE. FURTHER TROUBLESHOOTING FOUND CONNECTOR P8503, PIN 9 PUSHED OUT & WILL NOT RESEAT. R & R CONNECTOR P8503 IAW ESPM 20-50-01, DID NOT FIX PROBLEM. R & R EPSU INVERTER 6 IAW AMM 33-50-11, DISDR SIMA20141126005Light · inoperativeMAIN CABIN DOOR EMER LIGHT INOPERATIVE. R & R MAIN CABIN DOOR EMER LIGHT LAMP IAW AMM 33-50-06-000-801-A & 33-50-06-400-801-A. OPERATIONS CHECKED GOOD AT THIS TIME.SDR SIMA20141104003Charger · inoperativeOVERWING EMER LIGHT INOPERATIVE. R & R NR 4 BATTERY PACK & CHARGER ASSEMBLY IAW AMM-33-50-04. OPERATIONS CHECKED GOOD.SDR SIMA20141027003Light · inoperativeRIGHT AFT OVERWING EMER EXIT LIGHT INOPERATIVE. REPLACED RT SIDE CTR FAIRING EXTERNAL EMER LIGHT LAMP IAW AMM 33-50-10 2 L 2 4 K 13. OPERATIONS CHECKED GOOD.SDR SIMA20141002007Unknown · failedTAKEOFF ABORTED AT 70 - 80 KNOTS DUE TO MASTER WARNING & MASTER CAUTION & SPS ADVANCED GPWS INOPERATIVE SPS 1 & 2. STALL PROTECTION SYS OPERATIONS GOOD IAW AMM 145 27-36-00. SEE THIS LOG PAGE ITEMS 2 & 3. EGPWS WIND SHEAR WARNING & FLIGHT GUIDANCE SYS, WISDR SIMA20140831001Unknown · malfunctionedAD 2 AIRSPEED & ALT WAS OFF DUE TO WATER OR ICE ON THE STATIC PORTS. CLEARED ON DESCENT. INSPECTED PITOT DRAIN HOSE FOR WATER IAW AMM 34-13-00 & PERFORMED OPERATIONS CHECK OF ADC 2. ADC 2 CHECKS NORMAL IAW AMM 34-15-00.SDR SIMA20140527004Icu · failedDURING FLIGHT 3273 CREW REPORTED COMM 1 & COMM 2 RADIO FAILURE AFTER TAKEOFF. EMER WAS DECLARED THE ACFT WAS REMOVED FROM SERVICE. TROUBLESHOOT IAW FIM TASK 23-12-00-810-802-A. FOUND COMM 2 TO BE WORKING NORMALLY. R & R VHF 1 ICU IAW AMM 23-00-01-000-801-ASDR SIMA20140504002Cradle · damagedFIRST OFFICER`S FLASHLIGHT CRADLE DAMAGED. R & R FIRST OFFICER`S FLASHLIGHT CRADLE IAW AMM TASK 33-50-16-000-801-A & 33-50-16-400-801-A.SDR SIMA20140430001Light · inoperativeSERVICE DOOR FAIRING EMERGENCY LIGHT INOPERATIVE. R & R EMERGENCY LIGHT LAMP IN SERVICE DOOR FAIRING IAW AMM 33-50-09-000-801-A & 33-50-09-400-801-A. OPERATIONS CHECKED GOOD AT THIS TIME.SDR SIMA20140407008Sensor · malfunctionedCLIMBING THROUGH 7000 FT, RECEIVED A NR 2 BLEED OVERTEMP IN ICING CONDITIONS. REMOVED AND REPLACED PRECOOLER TEMP SENSOR IAW MM 36-20-01.SDR SIMA20140303004Battery · dischargedLEFT AFT OVERWING EMERGENCY LIGHT INOPERATIVE. R & R EMERGENCY LIGHT CHARGER & BATTERY IAW WC 33-700-17, OPERATIONS CHECKED GOOD.SDR SIMA20140222004Charger · inoperativeRIGHT & LT EXTERIOR OVERWING EMERGENCY LAMPS INOPERATIVE. R & R NR 4 EMERGENCY BATTERY & CHARGER IAW AMM 33-50-04-000-801-A & 33-50-04-400-801-A. NO FIX, TROUBLESHOT EXTERNAL OVERWING EMERGENCY LAMPS USING WM 33-50-50. LAMPS TESTED GOOD WITH 6VDC APPLIED TOSDR SIMA20140213001Light · inoperativeSERVICE DOOR EMERGENCY LIGHT INOPERATIVE. R & R SERVICE DOOR EMERGENCY LIGHT LAMP IAW AMM 33-50-09-000-801-A & 33-50-09-400-801-A. OPERATIONS CHECKED GOOD.SDR SIMA20131027004Flashlight · inoperativeF/O'S RECHARGEABLE FLASHLIGHT INOPERATIVE. R & R FLASHLIGHT IAW AMM 33-50-16.SDR SIMA20131027003Lamp · inoperativeFOUND F/A'S FLASHLIGHT INOPERATIVE. REPLACED LAMP IAW AMM 33-50-16. OPS CHECKED GOOD.SDR SIMA20130603003Light · inoperativeDURING B-INPSECTION, FOUND THE MAIN DOOR EMERGENCY LIGHT INOPERABLE. THE ACFT WAS REMOVED FROM SERVICE. R & R THE MAIN DOOR EMERGENCY LIGHT IAW AMM TASK 33-50-06-000-801-A AND 33-50-06-400-801-A. THE OPS CHECK WAS GOOD. THE ACFT WAS RETURNED TO SERVICE.SDR SIMA20130601010Battery · dischargedTHE CREW REPORTED THE LT WING TO FUSELAGE EMERGENCY LIGHT INOPERABLE. THE ACFT WAS REMOVED FROM SERVICE. LT LIGHT EMERGENCY PN: 30-2510-3. BATTERY, EMERGENCY LIGHTING PN: 2013-1A. SN: 113275. BATTERY CHARGER ASSY PN: 11-0049. SN: 15185. ALLOWED BATTERIES SDR SIMA20130530001Unknown · unknownSHORTLY AFTER TAKEOFF IN ICING CONDITIONS, RECEIVED A NR 2 BLEED OVERTEMP EICAS MESSAGE. RAN AOM VOL 1 CHECKLIST. RECEIVED A WING ANTI ICE FAIL EICAS CAUTION MESSAGE FOLLOWED BY AN ICE COND - A/I INOPERATIVE EICAS WARNING MESSAGE. DECLARED AN EMERGENCY ANSDR SIMA20130503012Light · unsecureDURING B INSPECTION, FOUND THE EMERGENCY LIGHT STRIP AT SEAT 10A LIFTING OFF OF THE FLOOR. THE ACFT WAS REMOVED FROM SERVICE. REATTACHED THE EMERGENCY LIGHT STRIP AT SEAT 10A. THE OPS CHECK WAS GOOD. THE ACFT WAS RETURNED TO SERVICE.SDR SIMA20130503011Terminal · missingDURING MX INSP, FOUND THE TERMINAL FOR EMERGENCY LIGHT STRIP AT FLOOR PANEL 241DF MISSING. THE ACFT WAS REMOVED FROM SERVICE. REPAIRED THE TERMINAL FOR EMERGENCY LIGHT STRIP AT FLOOR PANEL 241DF IAW MM 20-21-00. THE OPS CHECK WAS GOOD. THE ACFT WAS RETURNESDR SIMA20130503010Gusset · corrodedDURING MX INSPECTION, FOUND THE GALLEY CENTER BEAM GUSSET CORRODED BETWEEN FRAMES 20 AND 23. THE ACFT WAS REMOVED FROM SERVICE. REMOVED AND INSTALLED NEW GALLEY CENTER BEAM GUSSET IAW SRM 51-40-02. THE LEVEL OF CORROSION WAS NOT SPECIFIED. THE ACFT WAS RETURN
Back to N671AE