N678AE
Service difficulty reports · 128
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N678AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N678AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA20170802003Light · inoperativeEMERGENCY LIGHT FAILED TO ILLUMINATE. R & R THE EMERGENCY LIGHT IAW AMM 33-50-12.SDR ASOA20160328030HSAcm · inoperativeSUP: MAINTENANCE R & R THE NR 2 ACM, OPERATIONALLY TESTED WITH NO DEFECTS NOTED, REMOVED THE MEK, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20160328030HA/C Pack · smokeTHE CREW REPORTED THAT SMOKE COMES OUT WHEN NR 2 PACK WAS TURNED ON. MAINTENANCE PLACED THE NR 2 PACK ON MEL 21-51-00-3, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA20150510006Skin · dentedDENT AT FRAME 3 - 5, STRINGER 13L - 15L. REPAIRED DENT IAW ERS-EM-53MR-1306 & SRM 51-75-00.SDR SIMA20150510007Skin · damagedCREASE AT FRAME 65 - 66, STRINGER 13R - 14R & IN PROXIMITY TO RIVET LINE. REPAIRED CREASE AT FRAME 65 - 66, STRINGER 13R - 14R & IN PROXIMITY TO RIVET LINE IAW SRM 53-31-01RE & 51-75-00.SDR SIMA20150509006Light · looseCEILING PANEL 253CLC FWD EXIT LIGHT LOOSE. R & R LIGHT ASSEMBLY IAW AMM 33-50-15. FOUND DURING PS 2 CHECK. OPERATIONS CHECKED GOOD.SDR SIMA20150507003Fastener · looseMAIN DOOR LIGHT FAILED FUNCTIONAL CHECK. SECURED THE LOOSE HARDWARE TO GND WIRE, W734-0002-20, ON MAIN DOOR EXTERNAL LIGHT ASSEMBLY, DS7062, IAW AMM 20-10-01. LIGHT CHECKED GOOD.SDR SIMA20150507002Light · looseROW 12 CEILING PANEL EMER LIGHT AFT SIDE LOOSE. R & R ROW 12 CEILING PANEL EMER EXIT LIGHT PANEL IAW AMM 33-50-15. OPERATIONAL CHECKED GOOD.SDR SIMA20150426006Floor Support · corrodedGALLEY RT OMEGA BEAM CORRODED AT FRAME 23. REPAIR GALLEY RT OMEGA BEAM AT FRAME 23 IAW ERS-EM-53MR-1230.SDR SIMA20150426005Yoke · crackedRIGHT ENG FWD LOWER YOKE CRACKED IN CTR FWD UPPER RADIUS. COMPLIED WITH EO EM-51MR-386 R1 LT OR RT ENG FWD LOWER YOKE REPAIR & REPLACEMENT.SDR SIMA20150405004Yoke · crackedLEFT ENG FWD LOWER YOKE CRACKED IN CTR FWD UPPER RADIUS. COMPLIED WITH EO EM-54MR-386 R1 LT OR RT ENG FWD LOWER YOKE REPAIR & REPLACEMENT.SDR SIMA20150404001Structure · bentLEFT LE NR 1 INBD FLANGE BENT. REPAIRED LT LE NR 1 INBD FLANGE IAW ERS-EM-5700-418.SDR SIMA20150403008Angle · corrodedCARGO DOOR LOWER INBD ANGLE EDGE MEMBER NUTPLATE HOLES ARE CORRODED. REMOVED & INSTALLED CARGO DOOR LOWER INBD ANGLE WITH SERVICEABLE IAW SRM 51-40-02.SDR SIMA20150402009Connector · brokenFLOOR EMER LIGHT CONNECTOR IS BROKEN OFF AT FRAME 33. REPAIRED FLOOR EMER LIGHT CONNECTOR IAW SWPM 20-21-00. SEE BOW 185942 FOR OPERATIONS CHECK.SDR SIMA20150402011Splice · not seatedEXTERNAL EMER LIGHT ON MAIN DOOR INOPERATIVE. RESEATED & OHMED SPLICES 7425 & 7426 IAW SWPM 20-21-00. OPERATIONS CHECKED GOOD. MULTIMETER EASI 4366 CONNECTOR MALE PN 48-7190.SDR SIMA20150402012Floor Support · corrodedGALLEY RT OMEGA BEAM CORRODED AT FRAME 23. REPAIRED RT OMEGA BEAM AT FRAME 23 IAW ERS-EM-53MR-1230.SDR SIMA20141219003Light · inoperativeMAIN DOOR EXTERIOR EMER LAMP INOPERATIVE. R & R MAIN DOOR EXTERIOR EMER LAMP IAW AMM 33-50-10-000-801-A & 33-50-10-400-801-A. OPERATIONS CHECKED GOOD.SDR SIMA20141209002Cradle · brokenFLIGHT ATTENDANT`S EMER FLASHLIGHT CRADLE BROKEN. R & R FLIGHT ATTENDANT'S EMER FLASHLIGHT ASSEMBLY IAW AMM.SDR SIMA20141111008Electronic Unit · failedON APPROACH WHEN GEAR WAS SELECTED DOWN, NO INTRANSIT BOX WAS NOTED & TRUST RATING NEVER CHANGED FROM CRZ TO 1. R & R LG ELECTRONICS UNIT IAW AMM 32-32-01. PERFORMED OPERATIONAL CHECK OF LG IAW AMM 32-30-00. OPERATIONS CHECKED GOOD.SDR SIMA20140922003Motor-Brake Unit · faultedFLAP LOW SPEED ON EICAS 678 MEL DEFERRAL 67827051D. FLAP CHANNELS FLAP LOW SPEED ADV ON FLAP LOW SPEED CHANNEL 2 INOPERATIVE. RESTORATION OF MEL PLANE ACFT PN SN EMB145 14500813. TROUBLE SHOT FOUND FLAP LT MOTOR BRAKE FAIL & FLAP LT WING BRAKE FAIL ON CMC. SDR SIMA20140922002Light · inoperativeMAIN DOOR EXTERNAL EMER LIGHT INOPERATIVE. R & R MAIN DOOR EXTERNAL EMER LAMP IAW TASK 33-50-10-000-801-A & TASK 33-50-10-400-801-A. OPERATIONS CHECK NO GOOD. MAIN DOOR EXTERNAL EMER LIGHT ASSEMBLY REQUIRED TRANSFERRED TO AML PAGE 3688870 ITEM 4.SDR SIMA20140918006Warning System · false activationE1 REV DISAGREE ON TAKEOFF ROLL AT APPROX 40KTS, MSG DISAPPEARED AT 50 KTS AFTER ABORT. E1 REV DISAGREE DEFER IAW MEL 78-2.SDR SIMA20140813003Battery · dischargedOVERWING & AFT AISLE EMER LIGHTS INOPERATIVE. R & R NR 4 EMER LIGHT BATTERY & CHARGER IAW WC 33-700-19. OPERATIONS CHECKED GOOD IAW WC 33-700-17. EMER LIGHT BATTERY PN 2013-1A & SN 70408.SDR SIMA20140806003Roller · dirtyMAIN CABIN DOOR DIFFICULT TO OPEN. CLEANED & LUBED ROLLERS AS REQUIRED IAW AMM 52-18-00.SDR SIMA20140720003Flashlight · defectiveTHE FLASHLIGHT BEHIND THE CAPTAIN SEAT IS VERY DIM & SMELLS LIKE BURNING. R & R ASSEMBLY IAW 33-50-05 AMM. OPERATIONS CHECKED OK.SDR SIMA20140517001Battery · dischargedFIRST OFFICER'S FLASHLIGHT DOESN'T HOLD CHARGE. REMOVED & INSTALLED BATTERY ON FIRST OFFICER`S FLASHLIGHT IAW AMM 25-60-00.SDR SIMA20140326004Flashlight · defectiveFIRST OFFICER'S FLASHLIGHT HOLDER LOOSE ON SIDEWALL & DOES NOT CHARGE CONTINUOUSLY. R & R FIRST OFFICER'S FLASHLIGHT ASSEMBLY IAW AMM 33-50-16. OPERATIONS CHECKED GOOD.SDR SIMA20140324005Holder · looseFLIGHT ATTENDANT`S FLASHLIGHT HOLDER LOOSE. TIGHTEN FLIGHT ATTENDANT`S FLASHLIGHT SCREWS AS REQUIRED, OPERATIONS CHECKED GOOD.SDR SIMA20140205005Flashlight · looseFORWARD FLIGHT ATTENDANT FLASHLIGHT & HOLDER IS LOOSE. FLASHLIGHT & CRADLE PROPERLY SECURED.SDR SIMA20131205003Light · inoperativeEMERGENCY LIGHT ON PAX DOOR INOPERATIVE. R & R BULB ON PAX DOOR EMERGENCY LIGHT IAW 145 AMM-33-50-06, OPERATIONS CHECKED GOOD.SDR SIMA20131029005Lamp · inoperativeMAIN DOOR EMERGENCY LIGHT INOPERATIVE. R & R EMERGENCY LIGHT LAMP ON MAIN DOOR IAW AMM 33-50-06-000-801-A AND 33-50-06-400-801-A. OPS CHECKED GOOD AT THIS TIME.SDR SIMA20131014003Lamp · unserviceableEMERGENCY LIGHT ON THE MAIN DOOR IS INOPERATIVE. R & R EMERGENCY LIGHT ON THE MAIN DOOR. OPS CHECKED GOOD.SDR SIMA20131009006Lamp · inoperativeROW 12 B/C EMERGENCY LIGHT INOPERATIVE. R & R LAMP IAW AMM 33-50-07-000-801-A AND 33-50-07-400-801-A. OPS CHECKED GOOD.SDR SIMA20130921003Lamp · inoperativeEMERGENCY LIGHT INOPERATIVE AT MAIN DOOR. R & R LAMP IAW AMM TASK 33-50-06-000-801-A AND 33-50-06-400-801-A. OPS CHECKED GOOD.SDR SIMA20130803002Bulb · inoperativeGALLEY OVERHEAD EMERGENCY LIGHT INOPERATIVE. GALLEY OVERHEAD EMERGENCY LIGHT BULB IAW AMM 33-50-09, OPS CHECKED GOOD IAW 33-50-00.SDR SIMA20130729001Smoke Detector · malfunctionedDURING TAXI, BAGGAGE SMOKE EICAS MSSAGE. PRESSED EXTINGUISHER BUTTON. R & R CARGO BAY SMOKE DETECTOR IAW AMM 26-15-01, FWD.SDR SIMA20130727002Warning Message · false activationDURING TAXI BAGGAGE SMOKE EICAS MESSAGE, PRESSED EXTG BAGGAGE BUTTON. R & R HIGH RATE AND METERING BOTTLES IAW AMM 26-23--01 AND OPS CHECKS GOOD.SDR SIMA20130711003Skin · crackedDURING MX INSPECTION, FOUND THE RT REAR FUSELAGE I SKIN CRACKED AT FRAME 75. ACFT REMOVED FROM SERVICE. REPAIRED IAW EO EM-53MR-2161. ACFT RETURNED TO SERVICE.SDR SIMA20130709010Door Frame · crackedDURING MX INSPECTION, FOUND DOOR FRAME CRACKED AT HANGING BRACKET. ACFT REMOVED FROM SERVICE. REPAIRED IAW EO-EM-52MR-361. ACFT RETURNED TO SERVICE.SDR SIMA20130625004Cradle · brokenFORWARD PAX CABIN FLASHLIGHT CRADLE IS CRACKED. R & R FLASHLIGHT ASSY FOR CRACKED CRADLE IAW AMM 33-50-16, SYS CHECKED GOOD.SDR SIMA20130625005Sill · corrodedSERVICE DOOR CENTER SILL IS CORRODED. REMOVED AND INSTALLED NEW SERVICE DOOR CENTER SILL IAW SRM 51-40-02.SDR SIMA20130625003Connector · brokenCABIN EMERGENCY LIGHT NR 7 HAS ONE BROKEN CONNECTOR. INSTALLED NR 7 CONNECTOR IAW SWPM 20-21-00, STEP 5.SDR SIMA20130430001Holder · brokenON FLIGHT 3539 THE CREW REPORTED THE FIRST OFFICER’S FLASHLIGHT HOLDER WAS FOUND TO BE BROKEN. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED FIRST OFFICER’S FLASHLIGHT HOLDER IAW MM 25-60-00. THE AIRCRAFT WAS RETURNED TO SERVICE.SDR SIMA20130315004Display · faultyON FLIGHT 3309 THE CREW REPORTED A BURNING SMELL (INSULATION) IN FLIGHT. THE CAPTAIN’S MFD WENT BLACK. THE CREW REFERED TO THE CHECKLISTS TO NO AVAIL. AFTER WORKING WITH REVERSION PANEL, SCREEN CAME BACK ON IN REVERSIONARY PANEL "NORMAL" MODE. MFD NORMAL ASDR SIMA20121231002Flashlight · inoperativeDURING MAINTENANCE INSPECTION FOUND THE CAPTAIN’S FLASHLIGHT INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE CAPTAIN’S FLASHLIGHT ASSEMBLY IAW EMB 145 AMM 33-50-16. THE OPERATIONAL CHECK WAS GOOD. THE AIRCRAFT WAS RETURNED TO SESDR SIMA20121227003Flashlight · inoperativeCAPTAIN FLASHLIGHT INOP. FLIGHT CREW PLACARD PER MEL 25-53.SDR SIMA20121201001Roller · unknownON FLIGHT 4208 THE FLIGHT ATTENDANT REPORTED THE MAIN CABIN DOOR WAS EXTREMELY HARD TO OPEN. THE AIRCRAFT WAS REMOVED FROM SERVICE. SERVICED PASSENGER DOOR FRAME ROLLERS AS PER EMB AMM 53-21-02. THE PASSENGER DOOR OPENS WITH EASE. THE OPERATIONAL CHECK WASSDR SIMA20121117005Fairing · crackedDURING B INSPECTION FOUND THE MAIN DOOR EMERGENCY LIGHT ASSEMBLY FAIRING CRACKED. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE MAIN DOOR EMERGENCY LIGHT ASSEMBLY FAIRING. ANCHOR NUT - PART NUMBER: MS21059L06. RIVET- PART NUMBER: CCR244CSDR SIMA20120719007Power Supply · inoperativeDURING MAINTENANCE INSPECTION, FOUND THE AFT FLOOR EMERGENCY LIGHTS INOPERATIVE. AIRCRAFT REMOVED FROM SERVICE. REPLACED NR 3 AND 4 POWER SUPPLIES IAW MM 33-50-04. OPS CHECKED GOOD IAW MM 33-50-00. AIRCRAFT RETURNED TO SERVICE.SDR SIMA20120627006Light · inoperativeDURING B INSPECTION FOUND THE LEFT AFT OVERWING EMERGENCY LIGHT INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE LEFT OVERWING EMERGENCY LIGHT LAMP IAW EMB 145 AMM 33-50-07-000-801-A AND 33-50-07-400-801-A. THE OPERATIONAL CHECK W