SDR SIMA201910285002Light · inoperativeEMERGENCY LIGHT ABOVE LH WING INOP-C/A-REMOVED AND REPLACED EMERGENCY LIGHT ABOVE LH WING IAW EMB 145 AMM 33-50-10. OPS CHECK GOOD.Oct 25, 2019 · N681AE · Emb EMB145LR · Emergency LightingSDR SIMA2019101430001Lamp · inoperativeDURING PS-2 CHECK, FOUND LT SIDE CENTER FAIRING EMERG LIGHT INOP. REMOVED AND REPLACED EMERG LIGHT LAMP IAW EMB 145 AMM 33-50-10. OPS CHECK GOOD.Oct 13, 2019 · N681AE · Emb EMB145LR · Emergency LightingSDR SIMA20190907002Light · inoperativeLEFT OVERWING EMERGENCY LIGHT INOP. C/A-REMOVED AND REPLACED LEFT OVERWING EMERGENCY LIGHT BULB, IAW AMM 33-50-07. OPS CHECK GOOD. NO FURTHER DEFECTS NOTED.Sep 7, 2019 · N681AE · Emb EMB145LR · Emergency LightingSDR SIMA201908265001Inverter · inoperativeCENTER AISLE EMERGENCY LIGHT SYSTEM IS INOP. REMOVED AND REPLACED THE NR 5 DC/AC INVERTER IAW AMM 33-50-11. OPS CHECKED GOOD.Aug 25, 2019 · N681AE · Emb EMB145LR · Emergency LightingSDR SIMA201908221002Bleed Valve · failedAPU BLEED VALVE FAIL WITH THE OPEN INSCRIPTION ILLUMINATED. REMOVED AND REPLACED APU BLEED VALVE IAW AMM 36-12-03. OPC GOOD.Aug 21, 2019 · N681AE · Emb EMB145LR · APU Bleed Air SystemSDR SIMA20190819003Light · inoperativeLH OVER WING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED LH OVER WING EMERGENCY LIGHT IAW AMM 33-50-07-000-801-A AND 33-50-07-400-801-A.Aug 19, 2019 · N681AE · Emb EMB145LR · Emergency LightingSDR SIMA20190706004Charger · inoperative#4 EMERGENCY BATTERY/CHARGER INOP. C/A-REMOVED AND REPLACED BATTERY HOLDER AND BATTERY CHARGER ASSEMBLY IAW AMM 33-50-04, OPERATIONALLY CHECKED GOOD.Jul 6, 2019 · N681AE · Emb EMB145LR · Emergency LightingSDR SIMA20190706003Connector · damaged#8 EMERGENCY FLOOR LIGHTING STRIP ON A/C SIDE HAS DAMAGED CONNECTOR. C/A-INSTALLED NEW CONNECTORS ON WIRES W192-8832-22 AND W192-8833-22 IAW SWPM 20-21-00.Jul 6, 2019 · N681AE · Emb EMB145LR · Light System WiringSDR SIMA20190627001Skin · dentedTDMI PERFORM PERMANENT REPAIR OF DENT LOWER AFT CORNER OF SERVICE DOOR-C/A-PERFORMED PERMANENT REPAIR OF SERVICE DOOR LOWER AFT CORNER IAW ERS-EM-52MR-998Jun 27, 2019 · N681AE · Emb EMB145LR · Service DoorsSDR SIMA201906265005Nut Plate · corrodedCARGO DOOR LOWER NUT PLATE HOLES HAVE CORROSION.-C/A- INSTALLED SERVICEABLE CARGO DOOR LOWER PROFILE IAW EMB 145 SRM 51-40-02.Jun 25, 2019 · N681AE · Emb EMB145LR · Cargo/Baggage DoorsSDR SIMA201906265006Nut Plate · corrodedLOWER MOST NUTPLATE HOLE ON FWD EDGE OF CARGO DOOR IS OUT OF LIMITS.-C/A-REPAIRED LOWER NUTPLATE HOLE ON FWD EDGE OF CARGO DOOR IAW EMB 145 SRM 52-30-04.Jun 25, 2019 · N681AE · Emb EMB145LR · Cargo/Baggage DoorsSDR SIMA201906265007Nut Plate · corrodedCARGO DOOR UPPER NUT PLATE HOLES HAVE CORROSION 4 EA.-C/A-REMOVED AND REPLACED CARGO DOOR UPPER PROFILE IAW EMB 145 SRM 51-20-02.Jun 25, 2019 · N681AE · Emb EMB145LR · Cargo/Baggage DoorsSDR SIMA201906265003Floor Support · corrodedLEFT OMEGA BEAM CORRODED FROM FRAMES 22 TO 24. REPAIRED THE OMEGA BEAM IAW ERS-EM-53MR-3818.Jun 25, 2019 · N681AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA201906265004Door Sill · corrodedSERVICE DOOR CENTER SILL IS CORRODED-C/A-REMOVED AND REPLACED SERVICE DOOR CENTER SILL IAW SRM 51-40-02Jun 25, 2019 · N681AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA201906241002Light · brokenNUMBER 3 EMERGENCY FLOOR LIGHT STRIP WIRE BROKEN. REMOVED AND REPLACED LIGHT ON NUMBER 3 EMERGENCY FLOOR LIGHT STRIPS IAW EMB 145 AMM 33-50-12.Jun 21, 2019 · N681AE · Emb EMB145LR · Emergency LightingSDR SIMA2019062417013Door Sill · corrodedBAGGAGE DOOR SILL IS CORRODED. REMOVED AND REPLACED BAGGAGE DOOR SILL IAW EMB 145 SRM 53-40-02Jun 17, 2019 · N681AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20190519002Light · inoperativeWING TO FUSELAGE EMERG LIGHT LT AFT INOP. C/A-WING TO FUSELAGE LT AFT EMERG LIGHT RELAMPED IAW AMM 33-50-10 OPC GOOD.May 19, 2019 · N681AE · Emb EMB145LR · Emergency LightingSDR SIMA20190519004Light · inoperativeAFT AISLE EMERGENCY LIGHT INOP. C/A-AFT AISLE EMERGENCY LIGHT BULB REPLACED IAW AMM 33-50-08. LIGHTING TEST GOOD.May 19, 2019 · N681AE · Emb EMB145LR · Emergency LightingSDR SIMA2019040122001Warning Message · false indicationCABIN ALT DISPLAYED AMBER DASHES ON DEPARTURE, INDICATION RETURNED DURING DESCENT.-C/A-AT THIS TIME C/W OPS CK ON MANUAL PRESS. SYST PER AMM 21-31-00, FOUND SYST WORKING PROPERLY.Mar 31, 2019 · N681AE · Emb EMB145LR · Cabin Pressure Control SystemSDR SIMA201902265001Relay · malfunctionedOXYGEN LO PRESS IMMEDIATLEY AFTER TAKE OFF OXY PREE GAUGE READS 0 PSI-C/A-FOUND 02 GAUGE TO BE READING 1650 PSI. COCKPIT INDICATION READS ZERO DEFERRED OXYGEN PRESSURE INDICATION SYSTEM MEL 35-01 AUTH 020878-B. REMOVED AND REPLACED O2 CTRL TRANSFERRELAY K0417Feb 25, 2019 · N681AE · Emb EMB145LR · Crew Oxygen SystemSDR SIMA20190213003Fuse · blownLT AND RT OVER WING EMERGENCY LIGHTS INOP. FOUND FUSE BLOWN ON #4 EMERGENCY BATTERY CHARGER. REMOVED AND REPLACED FUSE IAW CMM 25-60-03. OPS CHECK GOOD IAW AMM 33-50-00-700-801.Feb 13, 2019 · N681AE · Emb EMB145LR · Emergency LightingSDR SIMA2019021108003Battery Pack · inoperativeRH AFT EXTERNAL OVERWING EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED RH AFT EXTERNAL OVERWING EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-10-000-801-A AND EMB AMM 33-50-10-400-801-A. DID NOT FIX. SUSPECT #4 EMERGENCY BATTERY AND POWER SUPPLY BAD. REMOVED AND REPFeb 8, 2019 · N681AE · Emb EMB145LR · Emergency LightingSDR SIMA20190206001Battery Pack · dischargedUPON PS-1 INSPECTION CHECK PART 11-C FOUND EXTERNAL EMERGENCY LIGHT LT-RT TOP INOP. R&R BATTERY PACK AND BATTERY CHARGER ON NR 4 REF AMM 33-50-04. OPS CHECK GOOD. MEL ITEM RESTORED. BATTERY CHARGER ASSY P/N 11-0049 S/N 19285Feb 6, 2019 · N681AE · Emb EMB145LR · Emergency LightingSDR SIMA2018100128006Nozzle · dirtyON TAKEOFF WITH THRUST SET, EXCESSIVE MOISTURE/SMOKE NOTICED-C/A-CLEANED WATER SPRAY NOZZLE ON NR 1 PACK IAW AMM 21-51-13. OPS CHECK OF NR 1 PACK GOOD IAW AMM 21-51-00.Sep 28, 2018 · N681AE · Emb EMB145LR · Cabin Cooling SystemSDR SIMA20180624004Unknown · odorAC GOT HIT BY LIGHTNING ON RIGHT SIDE OF NOSE. THE PILOTS THEN NOTICED A BURNING SMELL. TRANSFERRED TO NRWC 681-MIA-03705. COMPLIED WITH LIGHTNING STRIKE INSPECTION IAW W/C 05-200-00.Jun 24, 2018 · N681AE · Emb EMB145LR · Air Distribution SystemSDR SIMA2018042019006Lamp · inoperativeRIGHT EXTERNAL WING AFT EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE LAMP IAW AMM 33-50-10-000-801-A, AND 33-50-10-400-801-A. OPS CHECKED GOOD.Apr 19, 2018 · N681AE · Emb EMB145LR · Emergency LightingSDR SIMA20180401002Skin · dentedFOUND A LARGE DENT AND CRACK IN THE FWD RT FUSELAGE SKIN, FRAME 2, STRINGER 15R. REPAIRED THE DAMAGE IAW ERS-EM-53MR-3219.Apr 1, 2018 · N681AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20180319002Sign · inoperativeRIGHT ESCAPE HATCH UPPER EXIT SIGN INOPERATIVE. REMOVED AND REPLACED THE SIGN. OPS CHECKED GOOD IAW AMM 33-50-14.Mar 19, 2018 · N681AE · Emb EMB145LR · Emergency LightingSDR SIMA20180204002Wire · brokenSERVICE DOOR LINING EMERGENCY LIGHT INOPERATIVE. FOUND A BROKEN WIRE DURING VISUAL INSPECTION. SPLICED THE WIRE IAW SWPM-2430-20-21-00. OPS CHECKED GOOD. NO FURTHER DISCREPANCIES FOUND.Feb 4, 2018 · N681AE · Emb EMB145LR · Light System WiringSDR SIMA20171129001Connector · unsecureSERVICE DOOR EMERGENCY LIGHT EXIT INOPERATIVE. FOUND TWO CONNECTORS UNSECURE. SECURED THE CONNECTORS, OPS CHECKED GOOD.Nov 29, 2017 · N681AE · Emb EMB145LR · Light System WiringSDR SIMA20171128002Charger · failedSERVICE DOOR EMERGENCY LT INOP. R&R SERVICE DOOR EMERGENCY LIGHT LAMP IAW AMM 33-50-10-000-801-A & 33-50-10-400-801-A OPS CHECK FAILED, REMOVED AND REPAIRED NR 2 EMERGENCY BATTERY CHARGER ASSEMBLY AND EMERGENCY BATTERY IAW W/C 33-700-19 OPS CHECK FAILED, TROUBNov 28, 2017 · N681AE · Emb EMB145LR · Emergency LightingSDR SIMA20171126002Lamp · inoperativeSERVICE DOOR EXTERIOR EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE LAMP IAW AMM 33-50-09-000-801-A, AND 33-50-09-400-801-A. OPS CHECKED GOOD.Nov 26, 2017 · N681AE · Emb EMB145LR · Emergency LightingSDR SIMA20170929002Lamp · inoperativeMAIN DOOR EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE LAMP IAW AMM 33-50-06-000-801-A, AND 33-50-06-400-801-A. OPS CHECKED GOOD.Sep 29, 2017 · N681AE · Emb EMB145LR · Emergency LightingSDR SIMA20170913001Inverter · failedOVERHEAD EMERGENCY EXIT SIGN AND AT THE SERVICE DOOR INOPERATIVE. TROUBLESHOT AND FOUND THE NR 1 INVERTER TO BE BAD IAW WM 33-50-50. INSTALLED A USED INVERTER AND OPS CHECKED IAW W/C 33-700-17, OPS CHECKED GOOD. NO FURTHER DEFECTS NOTED.Sep 13, 2017 · N681AE · Emb EMB145LR · Emergency LightingSDR SIMA20170828001Sign · inoperativeRT OVERWING EXIT SIGN INOP AT SEAT 12 B/C. ALLOWED EMERGENCY SYSTEM CHARGE FOR 30 MIN AND THEN PERFORMED OPERATIONAL CHECK OF EMERGENCY LIGHTS IAW AMM 33-50-00. OPS CHECK GOOD.Aug 28, 2017 · N681AE · Emb EMB145LR · Emergency LightingSDR SIMA20170807003Bleed Valve · failedAT 17,000 FT ICING CONDITIONS BLEED 2 VALVE FAILED, WING ANTI ICE FAILED AND ICE COND-ANTI ICE INOPERATIVE MESSAGES. REMOVED AND REPLACED THE RT ENGINE BLEED VALVE IAW AMM 36-11-05. OPS CHECKED GOOD. NO DEFECT NOTED ACCOMPLISHED OPERATIONAL TEST OF ANTI ICE SYAug 7, 2017 · N681AE · Emb EMB145LR · Compressor Bleed ValveSDR SIMA20170426003Wire · brokenNR 7 FLOOR PROXIMITY LIGHT HAS BROKEN WIRES. REMOVED AND REPLACED NR 7 FLOOR PROXIMITY LIGHT STRIP IAW AMM 33-50-12.Apr 26, 2017 · N681AE · Emb EMB145LR · Light System WiringSDR SIMA20170417003Skin · crackedCRACK AROUND RIVET ON FRAME 75 AT STRINGER 2L. PERFORMED PERMANENT REPAIR OF CRACK AROUND RIVET ON FRAME 75 AT STRINGER 2L IAW SRM 53-31-01 RE FIG 219, SHEET 2.Apr 17, 2017 · N681AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20170415004Fitting · corrodedCARGO DOOR CUTOUT LATERAL L-SHAPE IS CORRODED AT LWR GUIDE PLATE ON FRAME 65. REPAIRED CARGO DOOR CUTOUT LATERAL L-SHAPE CORROSION AT LWR GUIDE PLATE ON FRAME 65 IAW SRM 53-31-04.Apr 15, 2017 · N681AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20170415005Skin · burned3 BURNS IN SKIN BETWEEN FRAMES 26-27 STRINGERS 21L-21R. REPAIRED FUSELAGE SKIN BURNS BETWEEN FRAMES 26-27 STRINGERS 21L-21R IAW SRM 53-22-01.Apr 15, 2017 · N681AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20170415006Frame · corrodedFRAME 65 IS CORRODED AT LOWER GUIDE PLATE. FABRICATED AND INSTALLED REPAIR DOUBLER ON FRAME 65 AT LWR GUIDE PLATE IAW SRM 53-31-04, FIG 212, SHEET 2Apr 15, 2017 · N681AE · Emb EMB145LR · Fuselage Main, FrameSDR SIMA20170407008Fitting · crackedLT PYLON FWD YOKE LOWER FWD FITTING CRACKED. REMOVED AND REPLACED LT LOWER FORWARD YOKE FITTING IAW EO EM-54MR-386.Apr 7, 2017 · N681AE · Emb EMB145LR · Nacelle/Pylon Miscellaneous StructureSDR SIMA20170328004Light · crackedLT EMERGENCY LIGHT EXTRUSION NR 1 AND NR 3 CRACKED. REMOVED AND REPLACED LT EMERGENCY LIGHT EXTRUSION NR 1 AND NR 3 IAW AMM 33-50-12. SEE NRTC BOW246051 FOR INSTALLATIONMar 28, 2017 · N681AE · Emb EMB145LR · Emergency LightingSDR SIMA20170220002Charger · inoperativeLT OVERWING EMERGENCY LIGHT INOP. R&R BATTERY CHARGER NR 4 IAW AMM 33-50-04. R&R BATTERY PACK NR 4 IAW AMM 33-50-04. OPS CK OF EMERGENCY LIGHTS GOOD. NO FURTHUR DEFECTS NOTED. EMERGENCY LIGHTING BATTERY P/N 2013-1A S/N 68896Feb 20, 2017 · N681AE · Emb EMB145LR · Emergency LightingSDR SIMA20170123001Thermostat · failedBLEED 2 OVERTEMP IN ICING CONDITION. T/S IAW FIM 36-11-00-810-804-A. REMOVED AND REPLACED FAN AIR CONTROL THERMOSTAT IAW AMM 36-11-06.Jan 23, 2017 · N681AE · Emb EMB145LR · Pneumatic Indicating SystemSDR SIMA20170122001Filter · failedNR 2 BLEED OVERTEMP DURING ICE PROTECTION TEST IN FLIGHT. REMOVED AND REPLACED THE RT FAN AIR VALVE FILTER IAW W/C 36-100-05. OPS CHECKED GOOD IAW AMM 36-00-00.Jan 22, 2017 · N681AE · Emb EMB145LR · Pneumatic Distribution SystemSDR SIMA20170101001Charger · failedLEFT AND RIGHT EXTERNAL OVERWING EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT SYSTEM CHARGER NR 4 AND BATTERY NR 4 IAW W/C 33-700-19. OPS CHECKED GOOD.Jan 1, 2017 · N681AE · Emb EMB145LR · Emergency LightingSDR SIMA20161215004Warning Message · false activationAFTER TAKEOFF, RT MLG INDICATED LANDING LEVER DISAGREE. INSPECTED MLG AND MLG UPLOCK, DOWNLOCK, AND WOW PROX SWITCHES IAW AMM 32-63-05. VERIFIED CMC MSGS AND FOUND NO MESSAGES ON CMC. PERFORMED LANDING GEAR SYS EXT AND RETRACTION TEST (4 TIMES) IAW AMM 32-30Dec 15, 2016 · N681AE · Emb EMB145LR · Landing Gear Retraction/Extension SystemSDR SIMA20161215003Warning Message · illuminatedAFTER TAKEOFF, THE RT MLG INDICATED LANDING LEVER DISAGREE AND RED WARNING INDICATION, DECLARED AN EMERGENCY.Dec 15, 2016 · N681AE · Emb EMB145LR · Landing Gear Retraction/Extension SystemSDR SIMA20161121003Power Supply · inoperativeCABIN FWD AISLE EXIT LIGHTS AND RT OVERWING FWD EMERGENCY EXIT LIGHTS INOPERATIVE. NR 2 POWER SUPPY BATTERY PACK AND BATTERY POWER SUPPLY R & R IAW WORKCARD 33-70-19. OPS CHECKED GOOD.Nov 21, 2016 · N681AE · Emb EMB145LR · Emergency Lighting
Back to N681AE