What was found
AFTER TAKEOFF, RT MLG INDICATED LANDING LEVER DISAGREE. INSPECTED MLG AND MLG UPLOCK, DOWNLOCK, AND WOW PROX SWITCHES IAW AMM 32-63-05. VERIFIED CMC MSGS AND FOUND NO MESSAGES ON CMC. PERFORMED LANDING GEAR SYS EXT AND RETRACTION TEST (4 TIMES) IAW AMM 32-30-00-700-801. NO DEFECTS NOTED OPS CHECK GOOD. PERFORMED MLG SHOCK ABSORBER INSPECTION AND EXT CHECK IAW AMM 32-10-02. NO DEFECTS NOTED. OK FOR SERVICE