N684JW
Service difficulty reports · 130
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N684JW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N684JW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA202002242002Channel · corrodedGALLEY SERVICE DOOR CENTER SILL HAS CORROSION AT MULTIPLE LOCATIONS.-C/A-REMOVED AND REPLACED SERVICE DOOR CENTER SILL IAW EMB 145 SRM 51-40-02.SDR SIMA20200218001Fitting · crackedDURING HMBV INSPECTION, QC FOUND LH PYLON FWD LOWER YOKE FITTING CRACKED.-C/A-REMOVED AND REPLACED YOKE FITTING IAW ERS-EM-54MR-698.SDR SIMA2020031204007Escape Rope · frayedCOPILOT AND PILOTS EMERGENCY ESCAPE ROPE FRAYED-C/A-COMPLETE:REMOVED AND REPLACED COPILOT AND PILOTS EMERGENCY ESCAPE ROPE IAW EMB145 AMM 25-60-07, 20-10-01, EASI TQ WR: EASI 7409.SDR SIMA2020031204008Battery · dischargedEMERGENCY LIGHT ON MAIN ENTRY WAY INOP-C/A-COMPLETE:REMOVED AND REPLACED BATTERY SUPPLY #1 IAW EMB 145 AMM 33-50-04. OPC GOOD.SDR SIMA2020031204010Wire Splice · brokenAFT FLASHLIGHT CHARGER ON LAV TOILET WALL SPLICE BROKEN AND BROKEN ON THE OPPOSITE SIDE ON THE LAV CEILING.-C/A-COMPLETE:REPAIRED WIRE TO SPLICE SP3557 IAW EMB 145 SWPM 20-21-00 AND WM 33-51-50SDR SIMA2020031204011Wire · damagedEMERGENCY LIGHT STRIP WIRE AT FR 45 ON AIRCRAFT SIDE IS DAMAGED-C/A-COMPLETE:UPON FURTHER INVESTIGATION BROKEN EMERGENCY LIGHT STRIP WIRE AT FR49 TO BE DAMAGED. RAR DAMAGED CONNECTOR FOR EMERGENCY LIGHT STRIP AT FR49 IAW EMB 145 SWPM 20-21-00. FOR OPC OF EMERGSDR SIMA2020031204012Holder · cracked4EA PROX LIGHT HOLDER AND 4EA RH SIDEWALLS ARE CRACKED-C/A-COMPLETE:REMOVED AND REPLACED 4EA PROX LIGHT HOLDER AND 4EA RH SIDEWALLS IAW EMB 145 AMM 33-50-12 SEE NRTC BOW340146 FOR FINAL INSTALLSDR SIMA2020031204013Wire · brokenEMERGENCY LIGHT STRIP WIRE FOR #1 LIGHT STRIP HAS BROKEN WIRE AT PIN ON AIRCRAFT SIDE-C/A-COMPLETE:RE TERMINATED EMERGENCY LIGHT STRIP #1 LIGHT STRIP WIRE AT PIN ON AIRCRAFT SIDE IAW EMB 145 WM 33-50-50, SWPM 20-00-03, 20-21-00. SEE TURNOVER FOR DETAILSSDR SIMA2020031204006Wire · broken2EA PROX LIGHT WITH ARROWS, 1EA SERVICE DOOR EXIT PROX LIGHT, AND 1EA PROX LIGHT WITHOUT ARROWS HAVE BROKEN WIRES-C/A-COMPLETE:REMOVED AND REPLACED 2EA PROX LIGHT WITH ARROWS, 1EA SERVICE DOOR EXIT PROX LIGHT, AND 1EA PROX LIGHT WITHOUT ARROWS IAW EMB 145 AMM SDR SIMA2020031204005Wire · brokenEMERGENCY EXIT LIGHT ON COCKPIT STEP PNL HAS A BROKEN WIRE-C/A-COMPLETE:REMOVED AND REPLACED EMERGENCY EXIT LIGHT ON COCKPIT STEP PNL IAW EMB 145 AMM 33-50-13. SEE NRTC# E778330 FOR COMPELTION OF EMERGENCY LIGHT OPS CHECK.SDR SIMA202001221002Warning Message · illuminatedFLAP LOW SPEED ADVISORY ON APPROACH-C/A-DEFERRED FLAP LOW SPEED, CH-2. M PROCEDURES C/WED.CMC MSG "FLAP L/H MOTOR BRAKE FAIL"MEL AUTH# 010786DM-B REF# 27-9SDR SIMA201911187003Warning Message · illuminatedFLAP LOW SPEED ON FINAL APPROACH-C/A-DEFERRED FLAP CHANNEL #2. "M" PROCEDURES C/W. CMC MESSAGE "FLAP LH MOTOR BRAKE FAIL".SDR SIMA201910098001Display · failedFO PFD INOP ELECTRICAL BURN SMELL. SOURCE OF ODOR FOUND AND CORRECTED. INSTALLED NR 2 PFD IAW MM 34-22-01. OPS CK GOOD IAW EMB MM 34-22-00. GROUND RAN AIRCRAFT PER R/R MM 72-00-00. OPERATED PACKS, COCKPIT LIGHTING AND WINDSHIELD HEAT. NO ODORS FOUND, OK FOR SDR SIMA201910032002Sign · unsecureEXIT SIGN AT 1A UNSECURE. SECURED THE EXIT SIGN AT 1A IAW AMM 25-60-00.SDR SIMA20190925003Light · burnedVISIBLE SMOKE AND ASSOCIATIED ELECTRICAL BURNING SMELL EMINATING FROM CAPTAINS YOKE, FLOOR AREA. INTERNAL APU POWER WAS SUPPYING ELECTRICAL LOADS. EVENT OCCURED AFTER STICK SHAKER/PUSHER, TRIM AND HYDFLIGHT CONTROL TESTS. TOKE MAP LIGHT WAS OFF. TESTS WERE SATSDR SIMA201908276002O-Ring · failedBLEED 2 LEAK AFTER AUDIBLE POP SOUND. REMOVED AND REPLACED O-RINGS AND COUPLING COVER AT BLEED COUPLING #8 IAW AMM 36-11-10. BLEED 2 LEAK CHECK GOOD IAW AMM 36-11-09-200-803.SDR SIMA20190728001Light · inoperativeCEILING EMERGENCY LIGHT AT ROW 17 INOP. C/A-REMOVED AND REPLACED CEILING EMERGENCY LIGHT LAMP AT ROW 17 IAW AMM 33-50-08 OPC GOOD.SDR SIMA201906108001Fan · failedSMELL OF RUBBERY SMOKE AT FL 260 ALL COCKPIT INDICATIONS IN COCKPIT WERE NORMAL AOM PERFORMED AND DIVERTED AS REQUIRED.-C/A-INSPECTED GALLEY AND CABIN BALLETS LAMPS AND FLASH LIGHTS AND COCKPIT LIGHTS FOR ABNORRMAL SMELL COMPLIED WITH ETN-EM-72-034 R 10 NO SMESDR SIMA201904220003Light · inoperativeEMERGENCY LIGHT BETWEEN ROW 7 & 9 INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT STRIP FROM ROW 7 8 9 PER 33-50-12 OPS CK GOODSDR SIMA20181106001Coupling · detachedBLEED 1 LEAK ON CLIMB OUT. REATTACHED HOSE COUPLING AT ACM NR 1 IAW MM CH 21-51-04.SDR SIMA20181104001Sleeve · damagedBLEED 1 LEAK CLIMBING OUT OF 6,000 AND CABIN ALT CONTINUED TO CLIMB. REMOVED PACK 1 PANEL IAW 06-41-01 OF AMM. PERFORMED GVI OF PACK 1 FOUND COUPLER ABOVE ACM LEAKING ISOLATED PACK 1 AND RAN ENGINE FOR 5 MIN IAW GHC WITH BLEED 1 SELECTED NO MESSAGES NOTED. REMSDR SIMA201810087002Duct · leakingBLD 1 LEAK DURING CLIMBOUT, EPC C/W. -C/A-PERFORMED REMOVED AND REPLACED OF DUAL TEMP CONTROL VALVE Y-DUCT IAW AMM 21-60-01. LEAK CHECK GOOD.SDR SIMA20180704003Light · inoperativeCEILING EMERGENCY LT AT ROW 17 INOP. R&R AISLE EMERGENCY LIGHT LAMP AT ROW 17 IAW AMM TASK 33-50-08-000-801-A AND 33-50-08-400-801-A, OPS CHECK GOOD AT THIS TIME.SDR SIMA201805165003Bulb · inoperativeRIGHT OVERWING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE BULB IAW AMM 33-50-07. OPS CHECKED GOOD IAW AMM 33-50-00.SDR SIMA20180320005Light · inoperativeMAIN DOOR EXTERNAL EMERGENCY LIGHT INOP.-C/A-REMOVED AND REPLACED MAIN DOOR EXTERNAL EMERGENCY LIGHT LAMP. OPS CHECKED GOOD IAW AMM 33-50-10SDR SIMA20171203001Flashlight · not reportedAFT CABIN EMERGENCY FLASHLIGHT NEEDS TO BE REPLACED-C/A-REMOVED AND REPLACED EMERGENCY FLASHLIGHT AS REQUIRED, NO OTHER DEFECTS NOTED AT THIS TIME.SDR SIMA20171114002Strap · damagedTEAR STRAP DAMAGED AT FRAME 22L BETWEEN STR 13L AND 14L. MAJOR REPAIR, PERFORMED REPAIR DAMAGED TEAR STRAP AT FRAME 22 BETWEEN STR 13L AND 14L IAW ERS-EM-53MR-3021.SDR SIMA20171023002Skin · crackedLT AFT FUSELAGE FR75 HAS SKIN CRACK ABOVE STR 2L. REPAIRED LT AFT FUSELAGE FR 75 SKIN CRACK ABOVE STR 2L IAW SRM 53-31-01 ITEM 11 FIG 219.SDR SIMA20171023001Skin · crackedSKIN CRACK AROUND RIVET AT FR75 BTW STGRS 2R-3R. REPAIRED SKIN CRACK AROUND RIVET AT FR 75 BTW STGRS 2R-3R IAW SRM 53-31-01 ITEM 11 FIG 219.SDR SIMA20171019006Skin · corrodedCORROSION ON INTERNAL SKIN FR 60-61 STR 20L-21L. REMOVED AND INSTALLED SERVICEABLE INT FUSELAGE REINFORCEMENT PLATE BTW FR 60-61 STR 20L-21L IAW SRM 51-40-02.SDR SIMA20171007002Power Supply · inoperativePAX DOOR EMERGECY LIGHTS INOPERATIVE. REMOVED AND REPLACED THE NR 1 POWER SUPPLY IAW AMM 33-50-04, OPS CHECKED GOOD.SDR SIMA20171007003Power Supply · inoperativeEMERGENCY LIGHT FLOOR ROWS 6 - 8 INOPERATIVE. REMOVED AND REPLACED THE POWER SUPPLY IAW AMM 33-50-04.SDR SIMA20170826001Bleed Valve · faultyDURING TAKEOFF E2 ATTCS NO MARGIN WARNING MSG. ABORT AT 90 KTS. AFTER ABORT E 2 EXCEEDANCE CAUTION MSG. OUTSIDE AIR TEMP, ATIS AND REF TO TEMP ALL 31C MAX ITT WAS 922C. REMOVED AND REPLACED RT ENG COMP BLEED VALVES AND RT ENG CABCV. PERFORMED ENGINE GROUND RUNSDR SIMA20150405003Wire · brokenNUMBER 6 EMER LIGHT STRIP HAS BROKEN WIRE. REPAIRED WIRE ON NR 6 EMER LIGHT STRIP IAW SWPM 20-21-00.SDR SIMA20150403005Skin · chafedFUSELAGE SKIN CHAFED INSIDE PANEL 414DB. PERFORMED REPAIR IAW ERS-EM-53MR-1206.SDR SIMA20150403004Connector · brokenEMERGENCY LIGHT STRIP HARNESS HAS BROKEN CONNECTOR AT FLOOR PANEL 251FF. R & R THE EMER LIGHT STRIP HARNESS CONNECTOR AT FLOOR PANEL 251FF SP9211 IAW SWPM 20-00-03.SDR SIMA20150402005Epsu · unknownREPLACE EPSU 4. R & R EPSU 4 IAW MNTC WC 33-700-19.SDR SIMA20150402007Epsu · unknownREPLACE EPSU 2. R & R EPSU 2 IAW MNTC WC 33-700-19.SDR SIMA20150402008Epsu · unknownREPLACE EPSU 3. R & R EMER EPSU 3 IAW MNTC WC 33-700-19.SDR SIMA20150402006Epsu · unknownR & R EPSU 1 IAW MNTC WC 33-700-19.SDR SIMA20150331006Structure · corrodedSERVICE DOOR CUT OUT STRUCTURE HAS SURFACE CORROSION AT LOWER FWD NUTPLATE HOLE. PERFORMED ERS-EM-52MR-1186 FOUND TO BE ACCEPTED AS IS.SDR SIMA20150316012Structure · corrodedCARGO DOOR LOWER INBD EDGE MEMBER NUTPLATE HOLES ARE CORRODED. REMOVED CORROSION FROM CARGO DOOR LOWER INBD EDGE MEMBER NUTPLATE HOLES & FOUND TO BE ACCEPTED AS IS IAW ERS-EM-52MR-312. SEE TURNOVER FOR DETAILS.SDR SIMA20141222009Tire · wornON SHORT FINAL, NOSE GEAR WAS MAKING A THUMPING SOUND. EXECUTED GO AROUND, CYCLED LG, & HEARD SAME THUMPING SOUND. APPROX 15 - 20 THUMPS IN 15 MINUTES. BOTH NOSE TIRES WORN TO LIMITS, DECLARED EMER. R & R LT NLG WHEEL ASSEMBLY & RT NLG WHEEL ASSEMBLY IAW WSDR SIMA20141113001Pump · leakingHYD 2 LOW QTY ON EICAS. SERVICED NR 2 HYDR RESERVOIR IAW EMB 145MM 12-13-01. TROUBLESHOOTING ITEM 1 ABOVE. FOUND NR 2 EDP TO BE LEAKING. REPLACED NR 2 EDP IAW EMB 145MM 29-10-03. OPERATIONS CHECKED GOOD.SDR SIMA20141111001Light · inoperativePARKING BRAKE LIGHT IS INOPERATIVE. R & R BRAKE LIGHT BULBS IAW AMM 20-13-04.SDR SIMA20131130002Sign · unsecureOVERHEAD EXIT SIGN IN CEILING FALLING DOWN 12A. SECURED CTR AISLE EXIT SIGN AT ROW 12 IAW STANDARD MTX PRACTICES.SDR SIMA20131105004Light · inoperativeFLOOR PROXIMITY LIGHT STRIP AT SEAT 6 IS INOPERATIVE. R & R LIGHT IAW AMM 33-50-12. OPS CHECKED GOOD. NO FURTHER DEFECTS.SDR SIMA20130827005Flashlight · inoperativeCAPTAIN`S FLASHLIGHT MUST BE SHAKEN TO WORK. R & R FLASHLIGHT IAW AMM 33-21-06. FLASHLIGHT OPS CHECKED GOOD.SDR SIMA20130808008Wire · brokenNR 1 EMERGENCY LIGHT HAS BROKEN WIRES. R & R LIGHT IAW AMM 33-50-12, OPS CHECKED GOOD.SDR SIMA20130801003Inverter · inoperativeEMERGENCY LIGHT ON AFT WALL OF GALLEY IS INOPERATIVE. R & R NR 3 EMERGENCY LIGHT INVERTER IAW AMM 33-50-11. OPS CHECKED GOOD IAW AE W/C 33-700-17.