N689EC
Service difficulty reports · 171
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N689EC' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N689EC' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HNAA2026071300594Hydraulic System · lowHYD 1 LOW DISPLAYED IN FLIGHT. SERVICED NR 1 HYD SYSTEM IAW AMM 12-13-01. OPS CHECK GOOD AT THIS TIME. OK FOR SERVICESDR HNAA2026052600434Bleed Valve · failedE1 HSV FAIL ON EICAS FACT 23MAY26 17:19 GSO. R & R NR 1 HSV IAW AMM 36-11-02. OPS AND LEAK CHECK GOOD.SDR HNAA2026050400366Windshield · no discrepancyBIRD STRIKE DURING TAKEOFF. PERFORMED BIRDSTRIKE INSPECTION IAW 05-50-08. CLEANED BIRD REMAINS OFF WINDSHIELD. NO DAMAGE/DEFECTS NOTED. AIRCRAFT OK FOR SERVICE AT THIS TIMESDR HNAA2026020100107Adc · failedADC 1 FAILED IN FLIGHT FACT 01FEB26 17:47 ALB R&R'D ADC1 AT POS 100 IAW EMB145 AMM 34-15-01. PERFORMED LEAK CHECK IAW AMM 34-13-00. OPS CHECK DONE IAW AMM 34-15-00, SYSTEM TESTED SERVICEABLE, OK FOR SERVICE.SDR HNAA2025090100583Acm · smokeSMOKE IN CABIN DURING CRUISE AT FL250. INSPECTED PACK SYSTEM, FOUND #200 ACM SIEZED W/ MELTED DUCTS ON #200 DUAL TEMP CONTROL VALVE. R/R'D DUCTS ON #200 DUAL TEMP CONTROL VALVE IRW AMM 21-60-01. R/R'D #200 ACM IRT AMM 21-61-03. OPS AND LEAK CHECK GOOD WITH NOSDR HNAA2025081200567Fan · cloggedFA REPORTS RUBBER HOSE SMELL WITH HISSING NOISE IN A ISLE GASPER AREA BETWEEN ROWS 2 AND 8 WITH GASPER FAN RUNNING. FOUND SEAT 8B GASPER TO BE CLOGGED. R/R'D PSU GASPER AIR ASSY IAW MM 25-22-05, OPS CK GOOD.SDR HNAA2025040800197Engine · bird ingestionBIRD STRIKE ON #2 ENGINE. #2 ENG CHANGE. SEE W/C 71-00-00 ON WORK PACKAGE.SDR HNAA2025030300117Bleed Valve · abnormalREJECTED T/O WITH HSV 2 FAIL DISPLAYED MSG WENT AWAY AFTER THRUST LEVERS PULLED BACK (DEACTIVATED BLEED VLV 2). R&R'D #200 HSV IAW 36-11-02-04 OPS CHECK GOOD NO RELATED EICAS MSGS OR OTHER DEFECTS NOTED AT THIS TIMESDR HNAA2024103001043Floor Support · corrodedE058889 CARGO DOOR LOWER CUTOUT FLOOR SILL CORRODED. RAR CARGO DOOR LOWER CUTOUT FLOOR SILL IAW EMB 145 SRM 51-40-02SDR HNAA2024103001048Floor Support · corrodedE058583 PAX DOOR LWR FWD FLOOR SUPPORT HAS CORROSION AROUND NUT-PLATES HOLES. RAR PAX DOOR LWR FWD FLOOR SUPPORT IAW EMB 145 SRM 51-40-02SDR HNAA2024103001047Floorbeam · corrodedE058611 GALLEY FLOOR CROSSBEAM AT FR-20 BETWEEN STGRS 21L/18L HAS CORROSION. BLENDED OUT CORROSION ON GALLEY FLOOR CROSSBEAM AT FR-20 BETWEEN STGRS 21L/18L IAW EMB145 SRM 51-10-03 AND FOUND REMAINIG THICKNESS TO BE WITHIN ALLOWABLE LIMITS IAW EMB145 SRM 53-21SDR HNAA2024103001046Floor Support · corrodedE058596 PAX DOOR LWR AFT FLOOR SUPPORT HAS CORROSION AROUND NUT-PLATES HOLES. RAR PAX DOOR LWR AFT FLOOR SUPPORT IAW EMB 145 SRM 51-40-02.SDR HNAA2024103001042Door Sill · corrodedE058598 SERVICE DOOR LWR CENTER SILL HAS CORROSION AROUND NUT-PLATES HOLES. PREPPED, FABRICATED, AND INSTALLED DOUBLERS ON SERVICE DOOR CENTER SILL IAW EMB 145 SRM 53-21-02RE FIGURE 201 AND EO1-53-24-0604SDR HNAA2024103001045Attach Fitting · gougedE058125 RH AILERON DAMPENER ATTACHMENT FITTING IS GOUGED IN MULTIPLE AREAS (ON AILERON). REMOVED AND REPLACED RH AILERON DAMPENER FITTING IAW EMB 145 SRM 51-40-02SDR HNAA2024103001041Housing · corrodedE058328 RH HORIZONTAL STAB SPHERICAL BEARING HOUSING PITTED. RPAIRED IAW SRM 55-30-02SDR HNAA2024103001040Profile · corrodedE058190 PAX DOOR LWR AFT PROFILES HAS CORROSION AROUND NUTPLATES HOLES. REPAIRED IAW EMB 145 SRM 52-10-04 STEP 3 FIGURE 201 SHEET 3 AND PIEDMONT EO1-52-24-0623.SDR HNAA2024103001044Torque Box · damagedE056822 RH WING TORQUE BOX 1 LOWER FWD CENTER FASTENER HOLE IS OVERSIZED AND DAMAGED. PREPPED, FABRICATED, AND INSTALLED BUSHINGS AND HILOCK IN RH WING TORQUE BOX 1 LOWER FWD HOLE IAW ETS2024-145-025752 "REV A" AND EO1-57-24-0603SDR SIMA20220103001None · noneINCORRECT FLIGHT ATTENDANT FLASHLIGHT INSTALLED-C/A-RAR FA FLASHLIGHT WITH CORRECT LED FLASHLIGHT ASSY IAW EMB-145 AMM 33-50-16 AND ETN-EM-33-059. OPC GOOD.SDR SIMA20211217001None · noneE2 SHUTOFF AT FL240/ SPD 290KTS/ OIL QUANTITY WENT TO RED AT 3 QTS. FLT DECLRD EMERG. LANDED SAFELY-C/A-REMOVED AND REPLACED #2 ENGINE IAW ENGINE REMOVAL AND INSTALLATION EMB 145 WORK CARD 71-000-00 OPERATION AND LEAK CHECK ARE GOOD.SDR SIMA20211212001None · noneFWD FA EMERGENCY FLASHLIGHT HOLDER ASSEMBLY BROKEN-C/A-FLIGHT CREW PLACARDED FWD FA EMERGENCY FLASHLIGHT HOLDER ASSEMBLY M PROCEDURES C/W REF: MEL 25-32 AUTH: 120159M-C MOC: 056020SDR SIMA20210920003None · noneCA DECLARED EMERGENCY DUE TO UNRELIABLE AIRSPEED. AMBER IAS ON AIRSPEED INDICATOR FOLLOWED BY SPS ADVANCED EICAS MSG. QRH PROCEDURE C/W. AIRSPEED RETURNED TO NORMAL AND MSG CLEARED IN DESCENT.CAPT DECLARED EMERGENCY DUE TO UNRELIABLE AIRSPEED. -C/A-INTERROGATSDR SIMA20210614001Light · inoperativeFLOOR EMERGENCY LIGHTS, 2 AND 3 INOP. R & R 2 AND 3 FLOOR PROXIMITY EMERGENCY LIGHT STRIPS IAW EMB145 AMM 33-50-12. OPS CHECK GOODSDR SIMA20210516003Inverter · inoperativeROW 12 OVERHEAD EMERGENCY LIGHT INOP-C/A-RAR #6 EMERGENCY DC/AC INVERTER IAW EMB AMM 33-50-11-000-801-A AND 33-50-11-400-801-A. OPC GOODSDR SIMA20210301002Wire · damagedSEVENTH EMERGENCY LIGHT STRIP ON LH SIDE FLOOR WIRES DAMAGED, LIGHT INOP-C/A-RAR FLOOR STRIP EMERGENCY LIGHT IAW EMB145 AMM 33-50-12. OPS CHECK GOOD.SDR SIMA202009098005Warning Message · illuminatedSPS 2 INOP WARNING AND SPS ADVANCED CAUTION ON EICAS DURING APPROACH TO LANDING. C/A PERFORMED FIM TASKS 27-36-00. SPS ADVANCED MESSAGE REMAINS, SEE AML 4558647 ITEM 2 FOR CONTINUED DISCREPANCY.SDR SIMA202009065002Clamp · looseBLEED 1 LEAK IN FLIGHT (DIVERTED BACK TO DFW) NO EMERGENCY DECLARED. -C/A-OPENED PACK 1 TO VERIFY BLEED LEAK TIGHTENED HOSE CLAMPS WAITED FOR EICAS MESSAGE. OPC GOOD IAW AMM 36-00-00/ETN-EM-21-956/21-51-02.SDR SIMA202009064001Computer · malfunctionedON DESCENT SPS 2 INOPERABLE WARNING WENT AWAY, BUT CAME RIGHT BACK AS WE RAN THE QRH SPS 1 INOPERABLE AS WELL WE ALSO RECEIVED STICK PUSHER FAIL AND SPS ADVANCED MECH, SPS FAIL. EMERGENCY DECLARED C/A-REF FIM TASK 27-36-00-810-A. PERFORMED RESET OF STALL PROTSDR SIMA20200827001Door Sill · corrodedSSI 53-30-48; CARGO DOOR SILL IS CORRODED. -C/A-EVALUATED CORROSION ON CARGO DOOR CENTER SILL AND FOUND TO BE OUT OF LIMITS IAW EMB 145 SRM 53-31-15AD. REMOVED AND REPLACED CARGO DOOR CENTER SILL IAW EMB 145 SRM 51-40-02 MATERIALS USED PN: 145-25480-603SD CARGSDR SIMA202008276002Structure · corrodedSSI 53-30-03; FRAME 68 CARGO DOOR LATERAL L-SHAPE IS CORRODED. -C/A-ACCOMPLISHED PERMANENT REPAIR ON FRAME 68 CARGO DOOR LATERAL L-SHAPE SHEAR CLIP IAW EMB 145 SRM 53-31-04RE ITEM 4DSDR SIMA202008276001Rib · crackedLH WING RIB 21 IS CRACKED INSIDE PANEL 551CB (AS MARKED).-C/A-REMOVED, FABRICATED AND INSTALLED REPAIR FILLER, DOUBLER, AND SHIM AT LH WING RIB 21 IAW EMB 145 SRM 57-20-07. MATERIAL LIST: FILLER: AL CLAD 2024 T3 OR AL CLAD 2024 T42 OR AL 7475 T7451 OR AL 7475 SDR SIMA202008242004Web · gougedCARGO DOOR INTERNAL WEB STRUCTURE GOUGED. REPAIRED CARGO DOOR INNER WEB IAW SRM 52-30-01.SDR SIMA202008242002Skin · crackedLH UPPER AFT FUSELAGE SKIN CRACKED JUST AFT OF FRAME 75 AND ABOVE STRINGER 2L, CRACK IS APPROX. 3/8? LONG ENDS ARE MARKED.-C/A-FABRICATED AND INSTALLED A REPAIR DOUBLER, FILLER, REPAIR ANGLE AND SHIM IAW EMB 145 SRM 53-31-01. MATERIALS USED: REPAIR DOUBLER ? ASDR SIMA202008251003Doubler · gouged2 PREVIOUSLY INSTALLED DOUBLERS ON CARGO DOOR LOWER WEB SECTION GOUGED. -C/A-REMOVED, FABRICATED AND INSTALLED DOUBLERS FOR CARGO DOOR INNER LOWER WEB IAW EMB 145 SRM 52-30-01 ITEM 12. MATERIAL FOR DOUBLERS: AL 7475-T761 (.040).SDR SIMA20200821002Door Frame · corrodedCARGO DOOR LOWER FRAME CORRODED AT SCREW HOLE. REMOVED AND REPLACED THE CARGO DOOR LOWER FRAME IAW SRM 51-40-02.SDR SIMA202008210002Floor Support · corrodedCENTER OMEGA BEAM AT FR 24-25 IS CORRODED. -C/A-BLENDED OUT CORROSION ON CENTER OMEGA BEAM AT FR 24-25 IAW SRM 51-10-03 AND CPM 51-14-02. REMAINING THICKNESS FOUND TO BE BEYOND LIMITS IAW SRM 53-22-10. FABRICATED AND INSTALLED A DOUBLER FOR REPAIR OF CENTER OMSDR SIMA2020082519006Frame · corrodedFRAME 65 IS CORRODED ABOVE CARGO DOOR SILL.-C/A-REMOVED AND REPLACED FR 65 SECTION AT CARGO DOOR CUTOUT IAW EMB 145 SRM 51-40-02. REPLACEMENT PN: 145-64106-001 FR 65 SECTION, PN: 145-03301-003 STR 16L SUPPORT (SHEAR CLSDR SIMA2020082419005Shear Tie · corrodedFRAME 65 CARGO DOOR SHEAR TIE WAS CORRODED. REMOVED AND REPLACED FR 65 CARGO DOOR SHEAR TIE IAW SRM 51-40-02.SDR SIMA20200817001Frame · crackedDURING HMBV INSPECTION, FR 73 CRACKED BETWEEN STR 15R-16R-C/A-RAR FR 73 LOWER SECTION TO REPAIR CRACK BETWEEN STR 15R-16R IAW EMB 145 SRM 51-40-02SDR SIMA202008174004Fitting · damagedRH AILERON PCA FITTING HAS ELONGATED BUSHING HOLES-C/A-RAR RH AILERON PCA FITTING IAW EO-EM-27MR-112SDR SIMA202008174003Service Panel · corrodedLAV BUCKET CORRODED AROUND SERVICING NIPPLE AND DRAIN HANDLE-C/A-RAR LAV BUCKET IAW EMB 145 SRM 51-40-02 AND 51-20-03SDR SIMA20200813002Floor Support · corrodedDURING HMBV INSPECTION, QA FOUND THE LH OMEGA BEAM AT FR 24-25 CORRODED-C/A-ACCOMPLISHED PERMANENT REPAIR ON LH OMEGA BEAM AT FR 24-25 IAW ERS-EM-53MR-4163. REPAIR MATERIAL; DOUBLER- 2024T3-.063?SDR SIMA20200726008Bulb · inoperativeEMERGENCY LIGHT ON CEILING PANEL AT 7A INOP. C/A COMPLETE: REMOVED AND REPLACED BULB ON CEILING PANEL 7A, IAW EMB 145 AMM 33-50-08. CHECKS GOOD.SDR SIMA20200726007Floor Support · corrodedRT FLOOR SILL HAS CORROSION AT FR 31, AS MARKED. C/A COMPLETE: FOUND CORROSION ON RT FLOOR SILL AT FR 31 TO BE OUT OF LIMITS, IAW EMB 145SRM 53-22-10. R & R CABIN RT NR 2 FLOOR SILL, IAW EMB 145 SRM 51-40-02.SDR SIMA20200726006Cradle · brokenEMERGENCY FLASHLIGHT CRADLE ON LAV WALL IS BROKEN. C/A COMPLETE: R & R EMERGENCY FLASHLIGHT CRADLE ON LAV WALL, IAW EMB 145 AMM 33-50-16. OPS CHECK GOOD.SDR SIMA20200726009Power Supply · not reportedSTD REQ A110 OPS A. REPLACE EPSU CRJ WC 33-002 OR EMB WC 33-700-19 PN: 11-0049 SN: 18369 POS: 2. C/A COMPLETE: PCW BY RECORDS REVIEW AND DVI OF EQUIPMENT INSTALLED ON AIRCRAFT, REF CITRIX (MTX OPS) NRWC 689-DFW-04797 DATED: 07/19/20. FOR R&R OF POS NR 2 EMESDR SIMA20200726005Floor Support · corrodedLT FLOOR SILL HAS CORROSION AT FR32, AS MARKED. C/A COMPLETE: BLENDED AND FOUND AREAS AT LT FLOOR SILL AT FR 32 TO BE OUT OF LIMITS, IAW EMB 145 SRM 51-10-03 AND 53-22-10. R&R LT OUTBOARD SILL NR 3, IAW EMB 145 SRM 51-40-02.SDR SIMA20200726004Connector · brokenEMERGENCY LIGHT STRIP NR 6 HAS BROKEN CONNECTOR. C/A COMPLETE: REMOVED AND REPLACED EMERGENCY LIGHT STRIP NR 6 BROKEN CONNECTOR, IAW EMB 145 SWPM 20-21-00.SDR SIMA202007189003Charger · inoperativeDURING PS-1 INSP FOUND EMERGENCY LIGHTS AT SERVICE DOOR AND RH WING TO FUSELAGE FAIRING INOP.-C/A-RAR #2 EMERGENCY BATTERY AND CHARGER ASSY IAW E145 AMM 33-50-04. OPERATIONAL CHECK GOODSDR SIMA2020040130001Battery · dischargedSUPPLEMENTAL MAIN DOOR (ENTRANCE CEILING) EMERG LIGHT INOP. CONTINUITY TO GROUND WHEN CONNECTOR P8500 (BATTERY CRADLE) DISCONNECTED AND POSITIVE WIRE AT BULB (W766-8052-20) BOTH WIRES AT BULB DISCONNECTED. NEW CRADLE NEEDED. (WHEN A NEW CRADLE INSTALLED BULB LSDR SIMA2020040130003Battery · broken#4 EMERGENCY LIGHT BATTERY HAS A BROKEN CAM LOCK.-C/A-REPLACED #4 EMERGENCY LIGHT BATTERY IAW AMM 33-50-04. OPS GOOD