N692CA
Service difficulty reports · 203
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N692CA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N692CA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWI2024F00420Landing · cracked* L/H FORWARD EQUIPMENT COMPARTMENT BOTTOM DOOR LANDING IS CRACKED AT THE FORWARD LATCH CUTOUT. (C-CHECK RO 5/28/2024) REMOVED AND REPLACED WITH NEW L/H FWD AVIONICS COMPARTMENT DOOR LANDING P/N: CC670-33151-3 REF REO 690-53-11-1731, REV --, DATED 2024-04-SDR SWI2024F00419Landing · cracked* R/H FORWARD EQUIPMENT COMPARTMENT BOTTOM DOOR LANDING IS CRACKED AT THE AFT LATCH CUTOUT. (C-CHECK RO 5/28/2024) REMOVED AND REPLACED RH FWD EQUIPMENT COMPARTMENT DOOR LANDING REF CRJ900 SRM 51-42-06-001-001-A01, DWG CC670-33040, REV -G, AND REO 690-53-1SDR SWIA2024052900308Skin · dentedCOMPLY WITH SCHEDULED MAINTENANCE CODE: RA26795-STS EA 30-2015-001 692CA-DTI - SMALL DENT FOUND ON LEFT SIDE FUSELAGE NEAR NOSE WHEEL, C/W PERMANENT REPAIR REF STS EA 30-.2015-001 REV A, PERFORM NDT GVI & LFEC PER STS EA 30-2015-001 REV B SEC II DTI. , PART NUSDR SWIA2024052900208Floor Support · corrodedCOMPLY WITH SCHEDULED MAINTENANCE CODE: RA59205-690-53-41-236 N692CA MXCODEID51913-TR - LH PRESSURE FLOOR ANGLE FS 720 €“ 744 L BL 40 APPROX. COMPLIED WITH TEMPORARY REPAIR OF L/H PRESSURE FLOOR ANGLE FS720-FS744 AT APPROX LBL40 REFERENCING REO 690-53-41-SDR SWI2024F00480Floor Support · corrodedCOMPLY WITH SCHEDULED MAINTENANCE CODE: RA59209-690-53-41-236 N692CA MXCODEID51918-TR - LH PRESSURE FLOOR ANGLE FS 797 €“ 847 L BL 40 APPROX. HAS CORROSION. COMPLIED WITH TEMPORARY REPAIR OF L/H PRESSURE FLOOR ANGLE FS797-FS847 AT APPROX LBL40 REFERENCING SDR SWI2024F00479Floor Support · damagedCOMPLY WITH SCHEDULED MAINTENANCE CODE: RA59204-690-53-41-236 N692CA MXCODEID51912-TR - LH PRESSURE FLOOR ANGLE FS 761 €“ 785 L BL 40 APPROX. COMPLIED WITH TEMPORARY REPAIR OF L/H PRESSURE FLOOR ANGLE FS761-FS785 AT APPROX LBL40 REFERENCING REO 690-53-41-2SDR SWI2024F00478Floor Support · corrodedCOMPLY WITH SCHEDULED MAINTENANCE CODE: RA59191- 690-53-41-236 N692CA MXCODEID51900-TR - RH PRESSURE FLOOR ANGLE FS 708 €“ 744 R BL 40 APPROX. HAS CORROSION. COMPLIED WITH TEMP REPAIR PRESS FLOOR ANGLE REF REO 690-53-41-236 REV B DATED 2020-04-20. TEMPORARSDR SWI2024F00477Floor Support · corrodedCOMPLY WITH SCHEDULED MAINTENANCE CODE: RA59136-690-53-41-236 N692CA MXCODEID51899-TR - RH PRESSURE FLOOR ANGLE FS 761 €“ 785 R BL 40 APPROX. HAS CORROSION. COMPLIED WITH TEMP REPAIR PRESSURE FLOOR ANGLE REF REO 690-53-41-236 REV B DATED 2020-04-20, TEMPORASDR SWI2024F00476Floor Support · corrodedCOMPLY WITH SCHEDULED MAINTENANCE CODE: RA59203-690-53-41-236 N692CA MXCODEID51910-TR - RH PRESSURE FLOOR ANGLE FS 785 €“ 830 R BL 40 APPROX. HAS CORROSION AS MARKED. COMPLIED WITH TEMPORARY REPAIR OF R/H PRESSURE FLOOR ANGLE FS785-FS830 AT APPROX RBL40 SDR SWI2023F00569Unknown · gougedFOUND GOUGE ON STGR7R AT FS1155 ~0.75 LONG, ~0.5 TALL AND ~0.25" DEEP CAUSED BY RAM AIR WATER SPRAYER LINE CHAFFING ON STRINGER AFTER STAND OFF BRACKET BROKE. (FILED CLOSED)COMPLIED WITH PERMANENT SPLICE REPAIR TO STGR7R BETWEEN FS1144.00 AND FS1162.00 PER RESDR SWIA202312130003Unknown · gougedFOUND GOUGE ON FS1162.00 FRAME REINFORCEMENT PLATE BETWEEN STGR7R AND STGR8R, ~0.6" LONG, ~0.06" WIDE, AND ~0.06" MAX DEPTH. (FILED CLOSED)COMPLIED WITH PERMANENT REPAIR TO FS1162.00 FRAME BETWEEN STGR 7R AND SSTGR 8R PER REO 690-53-71-071 REV -- DATE 2023-1SDR SWIA20230822728Unknown · crackedLINTEL STGR3 BTWN FS280 AND FS295 IS CRACKED (C-CHECK RO 8/20/2023) PERFORMED REPAIR ON LINTEL STGR3 BETWEEN FS280 AND FS295. REF. REO 670-53-21-493 REV. D, DATED 2015/07/10 AND SB 670BA-53-040 REV. C, DATED 09/20/2012. COMPLIED WITH SKYCARD 51-900-1002SDR SWI2023F00256Unknown · crackedRH FS220 UPPER INSTRUMENT PANEL SUPPORT BRACKET IS CRACKED (C-CHECK RO 8/20/2023) REMOVED AND REPLACED RH FS220 UPPER INSTRUMENT PANEL SUPPORT BRACKET REF CRJ 900 SRM 51-42-06-001-001-A01 AND DWG CC670-51720 REV -A COMPLIED WITH TASK CARD 51-900-1002-SKSDR SWI2023F00255Unknown · crackedLH FS235 FRAME UPPER GUSSET IS CRACKED (C-CHECK RO 8/20/2023) REMOVED AND REPLACED LH FS235 FRAME UPPER GUSSET IS CRACKED CRJ 900 SRM 51-42-06-001-001-A01 REVISION 38 JUL 25/2020B DWG CC670-34040 REV -C COMPLIED WITH TASK CARD 51-900-1002-SKYSDR SWIA20230822727Unknown · crackedLH FS235 UPPER FRAME IS CRACKED (C-CHECK RO 8/20/2023) VREMOVED AND REPLACED LH FS235 FRAME UPPER SECTOR WITH NEW P/N CC670-34133-9 REF CRJ 900 SRM 51-42-21-001-001-A01, SRM 51-42-06-001-001-A01 AND DWGCC670-34040 REV -CPERFORMED LEAK TEST OF THE LH FS2SDR SWIA2023051600014Unknown · warning messageR BLEED DUCT WARNING MESSAGE IN CLIMB JUST AFTER TAKEOFF. SHORTLY AFTER MESSAGE BECAME R BLEED DUCT CAUTION. QRH WAS RUN AND RETURNED TO FIELD. (FLT 3882 FILED CLOSED)THIS DISCREPANCY WAS TRANSFERRED TO CAMP ITEM 26623370 WITH THE FOLLOWING CORRECTIVE ACTION: SDR SWIA202305150014Unknown · warning messageR BLEED DUCT WARNING MESSAGE IN CLIMB JUST AFTER TAKEOFF. SHORTLY AFTER MESSAGE BECAME R BLEED DUCT CAUTION. QRH WAS RUN AND RETURNED TO FIELD. (FLT 3882 FILED OPEN)THIS IS CURRENTLY A WORK IN PROGRESSSDR SWIA20230511Unknown · dentedCOMPLY WITH SCHEDULED MAINTENANCE CODE: RA82382-REO 690-57-41-381,MXCODEID65957-PR - ON WALK AROUND, FOUND DENT IN THE MIDDLE OF THE RIGHT WING LEADING EDGE. COMPLIED WITH TEMPORARY REPAIR IN REFERENCE TO REO 390-57-41-381 REV -- DATED 2023-02-05. PERMANENT RSDR SWIA202265575None · crackedVERTICAL STABILIZER SKIN STRAP ANGLE TO FUSELAGE SKIN ON STRG2L FWD OF 67.5% REAR SPAR DATUM IS CRACKED. (FILED CLOSED) VERTICAL STABILIZER LH FWD DRAG ANGLE REPAIRED AS STATED IN MHIRJ SOW PER REO 670-55-31-018 REV A DATED 11-10-2016. NO FURTHER ACTIONSDR SWIA202163363None · noneDURING CLIMBOUT FORWARD FA REPORTED INTERMITTENT LOUD SPARKING FROM LOWER PORTION OF COMPARTMENT CONTAINING THE CREW O2 BOTTLE. (FLIGHT 3644 - FILED CLOSED)THIS DISCREPANCY WAS TRANSFERRED TO CAMP ITEM 24086334 WITH THE FOLLOWING CORRECTIVE ACTION: "REFERENCESDR SWIA2021113062856Fan · odorD: RECIRC FAN FAULT STATUS MESSAGE APPEARED IN FLIGHT. FOUND CIRCUIT BREAKER 1-A5 OPENED. WE SMELLED A SLIGHT SMELL OF ELECTRICAL BURN AND TURNED RECIRC FAN OFF. MESSAGE CLEARED AND SMELL WENT AWAY. / C: MEL 21-22-1B / CAT C EXP 12-9-21 / MTC ACTION COMPLIED WSDR SWIA202005190788Doubler · corrodedREMOVE AND REPLACE RADIO ALTIMITER #2 FWD AND AFT DOUBLERS (SPACERS) DUE TO CORROSION. (C-CHECK) RO 5/16/2020 REMOVED AND REPLACED RADIO ALTIMETER #2 FWD AND AFT DOUBLERS (SPACERS) REF CRJ900 SRM. CHECKS OKAY, COMPLETED TASK CARDSDR SWIA202005190825Panel · corrodedCORROSION ON THE LEFT HAND WING PANEL 542AZ. (C-CHECK) RO 5/16/2020 REPLACED LH WING PANEL 542AZ WITH NEW PANEL REF CRJ-900 SRM.SDR SWIA202005190824Panel · corrodedCORROSION ON THE RIGHT HAND WING PANEL 642AZ (C-CHECK) RO 5/16/2020 ORDERED AND RECEIVED NEW PANEL P/N CC670-10334-4, LOCATED AND DRILLED MOUNTING HOLES REF CRJ900 SRMSDR SWIA202005190785Skin · damagedCOMPLY WITH REPAIR TO FUSELAGE SKIN FOR CAMPS 20724547 (91509244/111), 20724552 (91509244/112), 20724556 (91509244/113), 20840027 (91509244/182) (C-CHECK) RO 5/16/2020 COMPLIED WITH PERMANENT REPAIR FUSE SKIN REF REO, VERIFIED ALL STEPS COMPLIED WITH, COMPSDR SWIA202005190784Rib · damagedUPON REMOVAL OF RH WING LESADING EDGE INBD FIXED SLAT SEAL FOUND 2EA ELONGATED HOLES THROUGH SLAT RIB AND SHIM AT BLIND FASTENER LOCATIONS (C-CHECK) RO 5/16/2020 REPAIRED RH WING LEADING EDGE INBD RIB 2EA ELONGATED HOLES COMMON TO IB FIXED SEAL REF REO. SESDR SWIA202005190783Angle · corrodedFWD PAX FLOOR STRUCTURE @ FS310 ATTACHING TO PAX FLOOR KICKPLATE ANGLE (PN SH670-31821-5) HAS CORROSION (C-CHECK) RO 5/16/2020 REMOVED ANS INSTALLED NEW FWD PAX FLOOR STRUCTURE @ FS310 ATTACHING TO PAX FLOOR KICKPLATE ANGLE IAW CRJ 900 SRM AND BOMBARDIER DSDR SWIA202005190782Floorbeam · crackedLH FLOOR BEAM FS274.00 IS CRACKED IN RADIUS (C-CHECK) RO 5/16/2020 REMOVED AND REPLACED LH FS274 FLOOR BEAM SECTION P/N 690-53-11-228-003S. REF: CRJ-900 SRM.SDR SWIA202005190781Doubler · corrodedANTENNA DOUBLER BETWEEN FS295 AND FS310 AT STGR 27 HAS CORROSION. (C-CHECK) RO 5/16/2020 REMOVED AND REPLACED DOUBLER REF SRM, BOMBARDIER DWG COMPLETED TASK CARD, ALL CHECKS OKAYSDR SWIA202005190828Angle · corrodedFRAME ANGLE LOCATED AT FS1047.00 FROM STGR 16L TO STGR 17L HAS CORROSION AROUND NUTPLATE LOCATION. (C-CHECK) RO 5/16/2020 REMOVED CORROSION ON LINER SUPPORT BRACKET ATTACHED TO FRAME FS1047 STGR 16L-7L REF. CRJ 900 SRM. ORIGINAL THICKNESS IS .040" REF. CRSDR SWIA202005190780Floorbeam · crackedRH FLOOR BEAM FS274.00 IS CRACKED IN RADIUS (C-CHECK) RO 5/16/2020 REMOVED AND REPLACED RH FLOOR BEAM SECTION P/N 690-53-11-228-004S. REF: CRJ-900 SRM.SDR SWIA202005190779Structure · corrodedCHORD ATTACHED TO AFT CARGO DOOR FLOOR SILL FROM FS1015.00 TO FS1031.00 HAS CORROSION (C-CHECK) RO 5/16/2020 REMOVED AND REPLACED INNER CHORD ON AFT CARGO DOOR FLOOR SILL FROM FS1015.00 TO FS1031.00 REF CRJ900 SRM AND DWG.SDR SWIA202005190778Stringer · corrodedCORROSION ON STGR 26R BETWEEN FS.319.70 AND FS.333.00. (MARKED) (C-CHECK) RO 5/16/2020 REMOVED AND REPLACED STRINGER REF CRJ 900 SRM AND DWG, COMPLETED TASK CARD, ALL CHECKS OKAYSDR SWIA202005190831Stringer Splice · corrodedCORROSION ON STGR 25R SPLICE ANGLE BETWEEN FS.319.70 AND FS.333.00 AT APPROX.FS.329.00. (MARKED) (C-CHECK) RO 5/16/2020 REMOVED AND REPLACED STRINGER SPLICE ANGLE REF SRM AND DWG, CHECKS OKAY, COMPLETED TASK CARDSDR SWIA202005190823Angle · corrodedPAX FLOOR ANGLE HAS CORROSION (C-CHECK) RO 5/16/2020 REMOVED AND INSTALLED NEW PAX DOOR ANGLE IAW CRJ 900 SRM.SDR SWIA202005190777Stringer · corrodedINTERGRANULAR CORROSION ON STRINGER 22R BETWEEN FS333 AND FS349. (C-CHECK) RO 5/16/2020 REMOVED AND REPLACED STR 22R BETWEEN FS333 TO FS349 REF CRJ-900 SRM AND DWG. SEE CONTINUATION CARD FOR DETAILS. CHECKS OKAYSDR SWIA202005190776Stringer Splice · corrodedINTERGRANULAR CORROSION ON THE AFT END OF STRINGER SPLICE ON STR 21R AT FS333. (C-CHECK) RO 5/16/2020 REMOVED AND REPLACED CORRODED STRINGER SPLICE ON STRG 21R AT FS333 REF CRJ900 SRM AND DWG. SEE CONTINUATION CARD FOR DETAILS. CHECKS OKAYSDR SWIA202005190775Stringer · corrodedSTRINGER25R AT FS324 HAS CORROSION (MARKED) (C-CHECK) RO 5/16/2020 REMOVED AND REPLACED STRINGER REF SRM AND DWG, CHECKS OKAY, COMPLETED TASK CARDSDR SWIA202005190774Frame · corrodedFRAME FS295.00 STGR26L TO STGR26R HAS SEVERE CORROSION (C-CHECK) RO 5/16/2020 REMOVED AND REPLACED FRAME SECTOR REF REO, VERIFIED ALL STEPS COMPLIED WITH, COMPLETED TASK CARD, CHECKS OKAYSDR SWIA202005190773Angle · crackedANGLE BL26.00 FS280.00 P/N CC670-34117-5 IS CRACKED (C-CHECK) RO 5/16/2020 REMOVED AND REPLACED ANGLE P/N CC670-34117-5 @ LBL26.00 FS280.00. REF: CRJ-900 SRM AND DRAWING.SDR SWIA202005190772Stringer · corrodedCORROSION UNDER THE FLOOR ON STGR26R IN BETWEEN FS1015.00 - FS1031.00 - MARKED. (C-CHECK) RO 5/16/2020 REMOVED AND REPLACED STR 26 REF SRM AND DWG, COMPLETED TASK CARD, CHECKS OKAYSDR SWIA202005190771Stringer · corrodedCORROSION ON STGR27 IN BETWEEN FS1069.75 - FS1088.20 - MARKED. (C-CHECK) RO 5/16/2020 REPLACED STGR 27 BETWEEN FS977 - FS1098 REFCRJ -900 SRM AND DWG, COMPLETED TASK CARD , ALL CHECKS OKAYSDR SWIA202005190770Door · cracked* R/H FWD EMERGENCY EXIT DOOR HAS A CRACK ON THE UPPER EDGE MEMBER. (MARKRD RED) (C-CHECK) RO 5/16/2020 REPAIRED FWD RHS OVERWING EMERGENCY EXIT USING BOMBARDIER REO. SEE CONTINUE CARD FOR FURTHER DETAIL.SDR SWIA202005190769Door · cracked* R/H AFT EMERGENCY EXIT DOOR HAS A CRACK ON THE UPPER EDGE MEMBER. (MARKRD RED) (C-CHECK) RO 5/16/2020 REPLACED THE RH AFT EMERGENCY EXIT DOOR WITH NEW DOOR P/N SH670-36600-1 INSTALLED ON CAMP# 20413474. FIT AND CLEARANCE CHECKED GOOD.SDR SWIA202005190768Door · cracked* L/H AFT EMERGENCY EXIT DOOR HAS A CRACK ON THE UPPER EDGE MEMBER. (MARKRD RED) (C-CHECK) RO 5/16/2020 REPAIRED AFT LHS OVERWING EMERGENCY EXIT DOOR USING BOMBARDIER REO. SEE CONTINUE CARD FOR FURTHER DETAIL.SDR SWIA202005190767Seat Track · puncturedUPON REMOVAL OF THE OUTBOARD CO PILOT SEAT TRACK, ELONGATED HOLES AND PUNCTURE THROUGH FLIGHT DECK FLOOR (C-CHECK) RO 5/16/2020 PERFORMED PERMANENT REPAIR TO OUTBOARD CO-PILOT SEAT TRACKAND FLIGHT DECK AS PER BOMBARDIER REO. VERIFIED ALL APPLICABLE STEPS CSDR SWIA202005190766Angle · corrodedRH PRESSURE FLOOR ANGLE FS 785 €“ 830 R BL 40 APPROX. HAS CORROSION AS MARKED (C-CHECK) RO 5/16/2020 COMPLIED WITH TEMPORARY REPAIR OF R/H PRESSURE FLOOR ANGLE FS785-FS830 AT APPROX RBL40 REFERENCING REO. COMPLIED WITH SKYWEST TASK CARD. COMPLETED SKYWSDR SWIA202005190765Skin · corrodedEXTERNAL FUSELAGE SKIN HAS CORROSION IN BETWEEN FS1069.75 AND FS1088.20, STGR 27 AND 26L AT STRUCTURAL COMPONENT - ANTENNA LABELED E8. (C-CHECK) RO 5/16/2020 REPAIRED EXTERNAL FUSELAGE SKIN BEETWEEN FS1069.75 AND FS1088.20, STR27 AND STR26L REFERENCING BOSDR SWIA202005190764Intercostal · corrodedINTERCOSTAL AT STGR26R, FS349 - FS364 FOUND TO BE CORRODED (C-CHECK) RO 5/16/2020 REMOVED CORROSION FROM INTERCOSTAL AND FOUND REWORKED AREA TO BE OUT OF LIMITS. REPLACED INTERCOSTAL AT STGR 26R, FS349 - FS364 REF CRJ-900 SRM, DWG. COMPLIED WITH TASK CARDSDR SWIA202005190822Door Sill · corroded* RIGHT HAND FWD EMERGENCY EXIT DOOR SURROUND - DOOR SILL HAS CORROSION AROUND NUTCLIP HOLES (2 EACH) (MARKED) (C-CHECK) RO 5/16/2020 REMOVED AND REPLACED THE RH FWD EMER EXIT DOOR SURROUND DOOR SILL. REF CRJ900 SRM.