What was found
FOUND GOUGE ON FS1162.00 FRAME REINFORCEMENT PLATE BETWEEN STGR7R AND STGR8R, ~0.6" LONG, ~0.06" WIDE, AND ~0.06" MAX DEPTH. (FILED CLOSED)COMPLIED WITH PERMANENT REPAIR TO FS1162.00 FRAME BETWEEN STGR 7R AND SSTGR 8R PER REO 690-53-71-071 REV -- DATE 2023-12-03 AND REO 670-53-71-047 REV A DATE 2015-12-22. COMPLIED WITH STRUCTURAL MAJOR REPAIR RII 51-900-1002-SKY. COMPLIED WITH MAJOR REPAIR M-337. SEE CAMP 27532786 FOR ROTOR PEEN.