N697AB
Service difficulty reports · 149
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N697AB' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N697AB' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA20190628001Flashlight · odorSUPPLEMENTAL COCKPIT SMOKE FUMES @FL 320 STRONG SMELL OF BURNT RUBBER. C/A-RAN BOTH PACKS WITH CREW NO SMELLS NOTED CREW SAID IT WAS NOT A PACK ISSUE. FOUND FOS FLASHLIGHT INOP AND EMITTING ELECTRICAL SMELL SWAPPED FO WITH AFT FLASHLIGHT DEFERRED AFT FLASHLIGHSDR SIMA201904087002Inverter · inoperativeRIGHT OVERWING EXIT MARKER INOP. REMOVED & REPLACED #5 INVERTER, RIGHT OVERWING EXIT MARKER OPERATES OK IAW EMB AMM 33-50-11.SDR SIMA20190327001Roller · lack of lubeDIFFICULTY OPENING MAIN CABIN DOOR. C/A-LUBED MAIN DOOR FRAME ROLLERS IAW MM 53-21-02.SDR SIMA20190320005Flashlight · inoperativeSUPPLEMENTAL AFT FA FLASHLIGHT INOP. C/A-FLIGHT CREW PLACARDED AFT FLIGHT ATTENDENT FLASHLIGHT // TEMP INSTALLED AUTH 030706-C REF 25-53 MOC 630997. REMOVED AND REPLACED AFT FA FLASHLIGHT IAW AMM 33-50-16. OPS CHECK GOOD MEL RESTORED.SDR SIMA20190317002Light · inoperativeOVERHEAD EMERGENCY LIGHT NR 3 FROM FWD IN CEILING PANEL INOP. C/A-REMOVED AND REPLACED OVERHEAD EMERGENCY LIGHT NR 3 FROM FWD BULB IAW AMM 33-50-08 OPS CHECK GOOD.SDR SIMA20190317001Connector · dirtyWHILE PERFORMING W/C 33-700-17 EMERGENCY LIGHTING SYS OPS CHECK FOUND RT OVER WING EXIT LIGHT INOP. C/A-CLEANED ELECTRICAL CONNECTORS AT NR 3 EMERGENCY LIGHTING POWER SUPPLY AND NR 4 AND NR 5 EMERGENCY LIGHTING AC/DC INVERTERS IAW AMM 33-50-04 AND 33-50-11. OPSDR SIMA2018121413003Oxygen Mask · disconnectedOBSERVER MASK LEAKING O2 IN FLIGHT. CREW O2 840 PSI AT 23 C -C/A-INSPECTED FOUND TO BE OBSERVER OXYGEN MASK DISCONNECTED MASK AND RESTOWED REF 4389396 ITEM 1. SERVICED CREW O2 IAW EMB 145 AMM 12-14-00 OK FOR SERVICESDR SIMA2018121009001Connector · looseBLD 1 LEAK IN FLIGHT QRH PROCEDURES COMPLIED WITH MESSAGE EXTINGUISHED.-C/A-INSPECTED PACK 1 FOR LOOSE DUCTING/CLAMPS. NO DEFECTS NOTED IAW EMB 145 AMM 21-20-04. FOUND #1 ENG BLEED VALVE CONNECTOR LOOSE. RESECURED CONNECTOR IAW EMB 145 AMM 36-11-05. NO DEFETCSSDR SIMA201812107002Clamp · leakingON CLIMB OUT NOTICED AIRCRAFT NOT PRESSURIZING. THAT WAS FOLLOWED BY BLD 1 VLV CLSD & PACK 1 VLV CLSD MSG ADVISORY. RESET THEM BUT MESSAGES KEPT COMIMG BACK WITH RUSH OF AIR EACH TIME-C/A-REMOVED AND REPLACED COUPLING AND CLAMP ON DUAL TEMP VALVE DUCT IAW ETN-SDR SIMA201809276003Light · inoperativeEMERGENCY LIGHT ON SEAT 12C INOP-C/A-RAR EMERG LIGHT EXIT SIGN ON SEAT 12C IAW AMM 33-50-14 OPC WAS GOOD AT THIS TIMESDR SIMA201806185002Flashlight · inoperativeTHE FORWARD FA FLASHLIGHT WAS INOPERATIVE. INSTALLED THE FLASHLIGHT IAW AMM 33-50-16. OPS CHECKED GOOD.SDR SIMA201804130001Cradle · inoperativeFLASHLIGHT IN BACK OF CABIN NOT CHARGING. REMOVED AND REPLACED THE FLASHLIGHT CRADLE IAW AMM 33-50-16, OPS CHECKED GOOD.SDR SIMA20171201001Flashlight · inoperativeFA FOWARD FLASHLIGHT INOP.-C/A-REMOVVED AND REPLACED FLASHLIGHT IAW AMM 33-50-16. OPS CK GOOD.SDR SIMA20170912005Floor Support · corrodedRIGHT OMEGA BEAM HAS CORROSION AROUND NUTPLATE HOLE AT FRAME 60 AND Y-479. REPAIRED THE OMEGA BEAM IAW SRM 53-24-10SDR SIMA20170912004Floor Support · corrodedLEFT OMEGA BEAM HAS CORROSION AROUND NUTPLATE HOLE AT FRAME 59 AND Y-479. REPAIRED THE OMEGA BEAM IAW SRM 53-24-10.SDR SIMA20170912006Floor Support · corrodedLEFT OMEGA BEAM HAS CORROSION AROUND NUTPLATE HOLE AT FRAME 60 AND Y-479. REPAIRED THE OMEGA BEAM IAW SRM 53-24-10.SDR SIMA20170909005Shear Tie · crackedCRACKED SHEAR TIE AT FRAME 67, STRINGERS 6 - 7L. REMOVED AND THE SHEAR TIE IAW SRM 51-40-02.SDR SIMA20170909009Skin · damagedSEVERAL HOLES IN FUSELAGE SKIN ARE ELONGATED WHERE SERVICE DOOR OR THRESHOLD ATTACHES TO SKIN STRINGER 16R, FRAMES 20 - 22. REAMED DISCREPANT HOLES TO REMOVE DAMAGE AND PREP FOR INSTALLATION OF FREEZ PLUG BUSHING.SDR SIMA20170909004Stiffener · crackedFRAME 18, STRINGER 3L STIFFENER CRACKED. INSTALLED A NEW STIFFENER.SDR SIMA20170909003Threshold · corrodedCORROSION AROUND THREE NUTPLATES FOR THE SERVICE DOOR THRESHOLD BETWEEN FRAMES 20 - 22. BLENDED THE CORROSION IAW SRM 51-10-03. REPLACED THE THRESHOLD.SDR SIMA20170909002Shear Tie · crackedCRACKED SHEAR TIE AT FRAME 66 STRINGERS 6 - 7. REMOVED AND REPLACED THE SHEAR TIE IAW SRM 51-40-02.SDR SIMA20170909001Floor Support · corrodedCENTER OMEGA BEAM AR FR 18-23 IS CORRODED WITH 100% MATERIAL LOSS. REMOVED AND REPLACED THE OMEGA BEAM IAW SRM 51-40-02.SDR SIMA20170909006Wire · broken1ST EMERGENCY LIGHT STRIP WIRES BROKEN AT STRIP. NR 1 EMERGENCY LIGHT OPS TESTED IAW AMM 33-50-12 AND ETN EM-33-058SDR SIMA20170909008Bracket · crackedNOSE LANDING GEAR UP LOCK BRACKET IS CRACKED. REMOVED AND REPLACED THE LT AND RT SUPPORTS FOR NLG UPLOCK BOX IAW SRM 51-40-02 AND AMM 20-10-01SDR SIMA20170717001Light · inoperativeSERVICE DOOR EXIT EMERGENCY LIGHT FOUND INOPERATIVE. REMOVED AND REPLACED THE EMERGENCY LIGHT IAW AMM 33-50-10-000-801, AND 33-50-10-400-801. OPS CHECKED GOOD.SDR SIMA20170302003Light · inoperativeDURING PS-1, FOUND PROXIMITY LIGHT STRIP FOR ROWS 8 AND 9 INOPERATIVE. REMOVED AND REPLACED THE EMERGENCY LIGHT IAW AMM 33-50-12. OPS CHECKED GOOD.SDR SIMA20170215001Charger · failedSERVICE DOOR EMERG LT INOP. T/S PER WM 33-50-50 FOUND NR 2 EMERGENCY BATTERY AND CHARGER TO BE BAD. REMOVED AND REPLACED NR 2 BATTERY AND CHARGER IAW WC N697AB. OPC GOOD, NO DEFECTS END. EMERGENCY LIGHTING BATTERY P/N 2013-1A S/N 68423SDR SIMA20170215002Light · inoperativeROW 6 3RD BACK FROM FRONT EMERG FLOOR STRIP INOP. THIS FLOOR STRIP IS NOT AND EXIT IDENTIFIER. R&R NR 3 FLOOR PROXIMITY STRIP IAW AMM 33-50-12-000-801-A AND 33-50-12-400-801-A. OPS GOOD.SDR SIMA20170207002Battery Pack · inoperativeFWD CABIN FLOOR PROXIMITY STRIP LIGHT AND EXTERIOR FWD EMERGENCY LIGHT INOPERATIVE. TROUBLESHOT IAW FIM 33-50-00-810-804-A FOUND NR 2 EMERGENCY BACKUP BATTERY BECAME DISCONNECTED FROM BATTERY HOLDER ASSY AND BENT BATTERY CONNECTIONS. R & R NR 2 EMERGENCY BACKSDR SIMA20161211002Pump · failedHYD 1 LOW QTY IN FLIGHT ON EICAS FOLLOWED BY E1 HDY PUMP FAIL. FOLLOWED BY HYD 1 SYSTEM FAIL. AFTER LANDING NO OUTBOARD BRAKES, NO STEERING. REMOVED AND REPLACED THE NR 1 HYDRAULIC PUMP IAW AMM 29-10-03. OPS AND LEAK CHECKED GOOD.SDR SIMA20160828004Lamp · inoperativeCOCKPIT EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE LAMP IAW AMM 33-50-05-000-801-A AND 33-50-05-400-801-A. OPS CHECKED GOOD.SDR SIMA20160414003Pressure Switch · faultyWHILE IN CRUISE WE RECEIVED HYD PUMP 1 FAIL ADVISORY, IT WAS INTERMITTENTLY, COME OFF & THEN ON, DIVERTED. R & R EDP PRESS SWITCH IAW AMM 29-10-19. OPERATIONS CHECKED GOOD.SDR SIMA20160404002Power Supply · inoperativeLOWER RT OVERWING EMER LIGHT INOPERATIVE. R & R NR 2 EMER LIGHT POWER SUPPLY. OPERATIONS CHECKED GOOD EMB AMM 33-50-04.SDR SIMA20160120004Wire · brokenSERVICE DOOR EXTERNAL EMERGENCY EXIT LIGHT INOPERATIVE. REPAIRED BROKEN WIRE 716-0007-20 & 716-008-20 AT SERVICE DOOR IAW SWPM 20-21-00. OPERATIONS CHECKED GOOD IAW MM 33-50-00.SDR SIMA20160110002Flashlight · brokenFIRST OFFICERS FLASHLIGHT ON & OFF SWITCH BROKE OFF. R & R FIRST OFFICERS FLASHLIGHT AS REQUIRED.SDR SIMA20151208001Display · failedNUMBER 1 PFD FAILED, WENT BLACK, ASSOCIATED ELEC BURNING SMELL, NO VISIBLE SMOKE. R & R NR 1 PFD, DU-1, IAW AMM 34-22-01. OPERATIONS CHECKED GOOD.SDR SIMA20151115003Light · inoperativeSERVICE DOOR EMER LIGHT INOPERATIVE. R & R SERVICE DOOR EMER LIGHT LAMP IAW AMM 33-50-09. OPERATIONS CHECKED GOOD IAW AMM 33-50-00.SDR SIMA20151003002Engine · smoke20 MIN AFTER SHUTDOWN, NR 1 ENG SMOKING. PERFORMED SMOKE ON SHUTDOWN ETN-EM-79-015. NO PRIOR OCCURRENCE NOTED. IAW ETN NO MX REQUIRED, ACFT OK TO RETURN TO SERVICE.SDR SIMA20150717004Holder · defectiveFLOOR EMER LIGHT STRIPS AT SEATS 9BC - 18BC ARE INOPERATIVE. R & R BATTERY HOLDER & BATTERY CHARGER ASSEMBLY IAW AMM 33-50-04. OPERATIONALLY CHECKED GOOD.SDR SIMA20150716002Skin · crackedFRAME 75 SKIN CRACK AT FASTENER AREA BELOW STRINGER 2L. PERFORMED PERMANENT REPAIR OF LT REAR FUSELAGE I SKIN AT FRAME 75 BELOW STRINGER 2L IAW ERS-EM-53MR-1491.SDR SIMA20150716001Light · inoperativeEMERGENCY LIGHT STRIP AT 9BC INOPERATIVE. REPLACED EMER LIGHT STRIP AT 9BC IAW AMM 33-51-10.SDR SIMA20150712008Connector · missingEMERGENCY LIGHT STRIPS NR 3 & 5 MISSING FLOOR CONNECTORS. INSTALLED CONNECTORS PN MS39029-31-229 & 48-7191 ON WIRE NRS, W192-8678-22 NR 3 & W192-8760-22 NR 5 IAW SWPM 20-21-00.SDR SIMA20150712007Connector · missingEMERGENCY LIGHT STRIP NR 6, ACFT SIDE, MISSING CONNECTOR. INSTALLED CONNECTORS PN MS39029-31-229 & 48-7191 ON WIRE NUMBERS W192-8830-22 IAW SWPM 20-21-00.SDR SIMA20150708007Wire · cutWIRES AT FRAME 25, STRINGER 15L ARE CUT. REPAIRED FRAME 25 FLOOR PROXIMITY LIGHT WIRES, W192-8680-22 & W192-8681-22, IAW SWPM 20-00-03, 20-00-05, 20-21-00 & AWM 91-10-02.SDR SIMA20150706004Connector · brokenFRAME 20 FLOOR PROXIMITY LIGHT WIRES BROKEN CONNECTORS. REPAIRED FRAME 20 FLOOR PROXIMITY LIGHT WIRES IAW SWPM 20-21-00. FOUND DURING OPEN UP.SDR SIMA20150701007Connector · brokenFOUND NR 8 FLOOR PROXIMITY LIGHT WIRES BROKEN CONNECTORS. REPLACED NR 8 FLOOR PROXIMITY LIGHT WIRES STRIP IAW AMM 33-50-12. FOUND DURING OPEN UP.SDR SIMA20150701006Wire · brokenAT FRAME NR 33, BROKEN WIRE FOR EMER LIGHT STRIP. BROKEN WIRE REPAIRED IAW SPWM 20-21-00. SEE NRTC BOW 194910 TASK 1 FOR OPERATIONS CHECK.SDR SIMA20150624002Structure · crackedRIGHT OVERWING UPPER FLANGE AFT AREA IS CRACKED. COMPLIED WITH ERS-EM-53MR-1482 RT OVERWING UPPER FLANGE REPAIR.SDR SIMA20150624007Structure · crackedRIGHT NR 1 FLOOR EXTRUSION CRACKED. R & R RT NR 1 FLOOR EXTRUSION IAW AMM 33-50-12.SDR SIMA20150624004Crossbeam · corrodedCENTER AISLE CROSSBEAM BETWEEN FRAME 24 - 25 IS CORRODED. R & R CTR AISLE CROSSBEAM IAW ETN-EM-53-139 & SRM 51-40-02.