N708EV
Service difficulty reports · 333
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N708EV' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N708EV' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA202161422None · none* R/H SLAT 2 TRACK 3 HAS MISSING PROTECTIVE COATING AND FRETTING TOP SIDE (C-CHECK RO 9/27/2021) REMOVED FRETTING FROM THE TOP SIDE OF RH SLAT TRACK 2-3. WITHIN LIMITS. REF REO-670-57-42-1140 REV -- DATED 2021-07-22 ALL STEPS COMPLIED WITH. COMPLIED WITSDR SWIA202161421None · none* R/H SLAT 2 TRACK 2 HAS MISSING PROTECTIVE COATING AND FRETTING TOP SIDE (C-CHECK RO 9/27/2021) REMOVED FRETTING FROM RH SLAT TRACK 2-2 TOP SIDE. WITHIN LIMITS. REF REO 670-57-42-1143 REV -- DATED 2021-07-22 ALL STEPS COMPLIED WITH. COMPLIED WITH 51-90SDR SWIA202161419None · none* R/H SLAT 2 TRACK 1 HAS MISSING PROTECTIVE COATING AND FRETTING TOP SIDE (C-CHECK RO 9/27/2021) REMOVED FRETTING FROM RH SLAT TRACK 2-1 TOP SIDE. WITHIN LIMITS. REF REO-670-57-42-1141 REV -- DATED 2021-07-22 ALL STEPS COMPLIED WITH. COMPLIED WITH 51-90SDR SWIA202161418None · none* R/H SLAT 1 TRACK 3 HAS MISSING PROTECTIVE COATING AND FRETTING TOP SIDE (C-CHECK RO 9/27/2021) BLENDED RH SLAT TRACK 1-3 TOP SIDE. WITHIN LIMITS. REF REO 670-57-42-1139 REV -- DATED 2021-07-26 ALL STEPS COMPLIED WITH. COMPLIED WITH 51-900-1002-SKY TOSDR SWIA202161416None · none* R/H SLAT 1 TRACK 2 HAS MISSING PROTECTIVE COATING AND FRETTING TOP SIDE (C-CHECK RO 9/27/2021) REMOVED FRETTING ON RH SLAT TRACK 1-2 TOP SIDE REF REO 670-57-42-1137 REV -- DATED 2021-07-26 ALL STEPS COMPLIED WITH. COMPLIED WITH 51-900-1002-SKY TOOL USDR SWIA202161415None · none* R/H SLAT 1 TRACK 1 HAS MISSING PROTECTIVE COATING AND FRETTING TOP SIDE (C-CHECK RO 9/27/2021) BLENDED RH SLAT TRACK 1-1 TOP SIDE WITHIN LIMITS REF REO 670-57-42-1138 REV -- DATED 2021-07-26 ALL STEPS COMPLIED WITH. COMPLIED WITH 51-900-1002-SKY TOOSDR SWIA202161413None · none* L/H SLAT 3 TRACK 2 HAS MISSING PROTECTIVE COATING AND FRETTING TOP SIDE (C-CHECK RO 9/27/2021) REMOVED FRETTING ON LH SLAT TRACK 3-2 TOP SIDE. WITHIN LIMITS. REF REO-670-57-42-1132 REV -- DATED 2021-07-23 ALL STEPS COMPLIED WITH. COMPLIED WITH 51-900-SDR SWIA202161411None · none* L/H SLAT 3 TRACK 1 HAS MISSING PROTECTIVE COATING AND FRETTING TOP SIDE (C-CHECK RO 9/27/2021) REMOVED FRETTING DAMAGE ON LH SLAT TRACK 3-1 BOTTOM SIDE. WITHIN LIMITS. REF REO 670-57-42-1131 REV -- DATED 2021-07-26 ALL STEPS COMPLIED WITH. COMPLIED WISDR SWIA202161410None · none* L/H SLAT 2 TRACK 3 HAS MISSING PROTECTIVE COATING AND FRETTING TOP SIDE (C-CHECK RO 9/27/2021) REMOVED FRETTING DAMAGE ON LH SLAT 2-3 TOP SIDE. WITHIN LIMITS. REF REO 670-57-42-1128 REV -- DATED 2021-07-26 COMPLIED WITH ALL STEPS. COMPLIED WITH 51-900SDR SWIA202161408None · none* L/H SLAT 2 TRACK 2 HAS MISSING PROTECTIVE COATING AND FRETTING TOP SIDE (C-CHECK RO 9/27/2021) REMOVED FRETTING ON THE TOP SIDE OF LH SLAT TRACK 2-2. WITHIN LIMITS REF REO-670-57-42-1129 REV -- DATED 2021-07-23 ALL STEPS COMPLIED WITH. COMPLIED WITH 5SDR SWIA202161406None · none* L/H SLAT 2 TRACK 1 HAS MISSING PROTECTIVE COATING AND FRETTING TOP SIDE (C-CHECK RO 9/27/2021) REMOVED FRETTING ON LH SLAT TRACK 2-1 TOP SIDE. WITHIN LIMITS REF REO 670-57-42-1127 REV -- DATED 2021-07-26 ALL STEPS COMPLIED WITH. COMPLIED WITH 51-900-1SDR SWIA202161405None · none* L/H SLAT 1 TRACK 3 HAS MISSING PROTECTIVE COATING AND FRETTING TOP SIDE (C-CHECK RO 9/27/2021) REMOVED FRETTING ON LH SLAT TRACK 1-3 TOP SIDE. WITHIN LIMITS. REF REO-670-57-42-1130 REV -- DATED 2021-07-23 ALL STEPS COMPLIED WITH. COMPLIED WITH 51-900-SDR SWIA202161403None · none* L/H SLAT 1 TRACK 2 HAS MISSING PROTECTIVE COATING AND FRETTING TOP SIDE (C-CHECK RO 9/27/2021) REMOVED LH SLAT TRACK 1-2 FRETTING ON THE TOP SIDE. WITHIN LIMITS. REF REO 670-57-42-1126 REV -- DATED 2021-07-26 ALL STEPS COMPLIED WITH. COMPLIED WITH 51-SDR SWIA202161398None · none* L/H SLAT 1 TRACK 1 HAS MISSING PROTECTIVE COATING AND FRETTING TOP SIDE (C-CHECK RO 9/27/2021) REMOVED FRETTING ON LH SLAT TRACK 1-1 FROM THE TOP SIDE. WITHIN LIMITS. REF REO-670-57-42-1125 REV -- DATED 2021-07-22 ALL STEPS COMPLIED WITH. COMPLIED WITSDR SWIA202161397None · none* L/H SLAT 3 TRACK 3 HAS MISSING PROTECTIVE COATING AND FRETTING BTM SIDE (C-CHECK RO 9/27/2021) REMOVED FRETTING ON LH SLAT TRACK 3-3. WITHIN LIMITS REO-670-57-42-1133 REV -- DATED 2021-07-23 ALL STEPS COMPLIED WITH. COMPLIED WITH 51-900-1002-SKY. TOOLSDR SWIA202161396None · none* L/H SLAT 3 TRACK 2 HAS MISSING PROTECTIVE COATING AND FRETTING BTM SIDE (C-CHECK RO 9/27/2021) REMOVED FRETTING ON LH SLAT TRACK 3-2 BTM SIDE. WITHIN LIMITS. REF REO-670-57-42-1132 REV -- DATED 2021-07-23 ALL STEPS COMPLIED WITH. COMPLIED WITH 51-900-SDR SWIA202161392None · none* L/H SLAT 3 TRACK 1 HAS MISSING PROTECTIVE COATING AND FRETTING BTM SIDE (C-CHECK RO 9/27/2021) REMOVED FRETTING DAMAGE ON LH SLAT TRACK 3-1 BOTTOM SIDE. WITHIN LIMITS. REF REO 670-57-42-1131 REV -- DATED 2021-07-26 ALL STEPS COMPLIED WITH. COMPLIED WISDR SWIA202161390None · none* L/H SLAT 2 TRACK 3 HAS MISSING PROTECTIVE COATING AND FRETTING BTM SIDE (C-CHECK RO 9/27/2021) REMOVED FRETTING DAMAGE ON LH SLAT 2-3 BTM SIDE. WITHIN LIMITS. REF REO 670-57-42-1128 REV -- DATED 2021-07-26 COMPLIED WITH ALL STEPS. COMPLIED WITH 51-900SDR SWIA202161389None · corroded* L/H SLAT 2 TRACK 2 HAS MISSING PROTECTIVE COATING AND CORROSION BTM SIDE (C-CHECK RO 9/27/2021) REMOVED CORROSION ON LH SLAT TRACK 2-2 BTM SIDE. WITHIN LIMITS. REF REO-670-57-42-1129 REV -- DATED 2021-07-23 ALL STEPS COMPLIED WITH. COMPLIED WITH 51-90SDR SWIA202161387None · none* L/H SLAT 1 TRACK 3 HAS MISSING PROTECTIVE COATING AND FRETTING BTM SIDE (C-CHECK RO 9/27/2021) REMOVED FRETTING FROM THE BOTTOM SIDE OF LH SLAT TRACK 1-3. WITHIN LIMITS. REF REO-670-57-42-1130 REV -- DATED 2021-07-23 COMPLIED WITH ALL STEPS. COMPLIED SDR SWIA202161385None · none* L/H SLAT 1 TRACK 2 HAS MISSING PROTECTIVE COATING AND FRETTING BTM SIDE (C-CHECK RO 9/27/2021) REMOVED FRETTING DAMAGE ON LH SLAT TRACK 1-2 BTM SIDE. WITHIN LIMITS. REF REO 670-57-42-1126 REV -- DATED 2021-07-26 ALL STEPS COMPLIED WITH. COMPLIED WITH SDR SWIA202161497None · corroded* L/H O/B GROUND SPOILER HAS CORRODED BOLT COMMON TO CENTER HINGE POINT ACTUATOR (C-CHECK RO 9/27/2021) REPLACED L/H O/B GROUND SPOILER OUTPUT LINK LOWER BOLT. REF CRJ 700 AMM 27-63-01-000-802-A01, AND 27-63-01-400-802-A01. / OPS TEST GOOD.SDR SWIA202161384None · none* L/H SLAT 1 TRACK 1 HAS MISSING PROTECTIVE COATING AND FRETTING BTM SIDE (C-CHECK RO 9/27/2021) REMOVED LH SLAT TRACK 1-1 FRETTING ON THE BOTTOM SIDE. WITHIN LIMITS REO-670-57-42-1125 REV -- DATED 2021-07-22 ALL STEPS COMPLIED WITH. COMPLIED WITH 51-90SDR SWIA202161382None · none* R/H SLAT 3 TRACK 3 HAS MISSING PROTECTIVE COATING AND FRETTING BTM SIDE (C-CHECK RO 9/27/2021) REMOVED FRETTING ON BOTTOM SIDE OF RH SLAT TRACK 3-3. WITHIN LIMITS. REF REO 670-57-42-1142 REV -- DATED 2021-07-22 ALL STEPS COMPLIED WITH. COMPLIED WITH 5SDR SWIA202161378None · none* R/H SLAT 3 TRACK 2 HAS MISSING PROTECTIVE COATING AND FRETTING BTM SIDE (C-CHECK RO 9/27/2021) REMOVED FRETTING ON BOTTOM SIDE OF RH SLAT TRACK 3-2. WITHIN LIMITS REF REO 670-57-42-1144 REV -- DATED 2021-07-22 ALL STEPS COMPLIED WITH. COMPLIED WITH 51SDR SWIA202161377None · none* R/H SLAT 3 TRACK 1 HAS MISSING PROTECTIVE COATING AND FRETTING BTM SIDE (C-CHECK RO 9/27/2021) REMOVED RH SLAT TRACK 3-1 FRETTING ON THE BOTTOM SIDE. REF REO 670-57-42-1146 REV -- DATED 2021-07-23 ALL STEPS COMPLIED WITH. COMPLIED WITH 51-900-1002-SKSDR SWIA202161376None · none* R/H SLAT 2 TRACK 3 HAS MISSING PROTECTIVE COATING AND FRETTING BTM SIDE (C-CHECK RO 9/27/2021) REMOVED FRETTING FROM BOTTOM SIDE OF RH SLAT TRACK 2-3. REF REO-670-57-42-1140 REV -- DATED 2021-07-22 ALL STEPS COMPLIED WITH. COMPLIED WITH 51-900-1002-SKSDR SWIA202161375None · corroded* R/H SLAT 2 TRACK 2 HAS MISSING PROTECTIVE COATING AND PITTING CORROSION BTM SIDE (C-CHECK RO 9/27/2021) REMOVED CORROSION ON BOTTOM SIDE OF RH SLAT TRACK 2-2. WITHIN LIMITS. REF REO 670-57-42-1143 REV -- DATED 2021-07-22 COMPLIED WITH ALL STEPS. COMPLSDR SWIA202161374None · none* R/H SLAT 2 TRACK 1 HAS MISSING PROTECTIVE COATING AND FRETTING BTM SIDE (C-CHECK RO 9/27/2021) REMOVED FRETTING FROM RH SLAT TRACK 2-1. WITHIN LIMITS. REF REO-670-57-42-1141 REV -- DATED 2021-07-22 COMPLIED WITH ALL STEPS. COMPLIED WITH 51-900-1002-SKSDR SWIA202161372None · none* R/H SLAT 1 TRACK 3 HAS MISSING PROTECTIVE COATING AND FRETTING BTM SIDE (C-CHECK RO 9/27/2021) BLENDED RH SLAT TRACK 1-3 BOTTOM SIDE. WITHIN LIMITS. REF REO 670-57-42-1139 REV -- DATED 2021-07-26 ALL STEPS COMPLIED WITH. COMPLIED WITH 51-900-1002-SKY.SDR SWIA202161370None · corroded* R/H SLAT 1 TRACK 2 HAS MISSING PROTECTIVE COATING AND PITTING CORROSION (C-CHECK RO 9/27/2021) REMOVED PITTING CORROSION ON RH SLAT TRACK 1-2. WITHIN LIMITS. REF REO 670-57-42-1137 REV -- DATED 2021-07-26 ALL STEPS COMPLIED WITH. COMPLIED WITH 51-900-SDR SWIA202161369None · none* R/H SLAT 1 TRACK 1 HAS MISSING PROTECTIVE COATING AND FRETTING ON BTM SIDE (C-CHECK RO 9/27/2021) BLENDED RH SLAT TRACK 1-1 BTM SIDE. REF REO 670-57-42-1138 REV -- DATED 2021-07-26 ALL STEPS COMPLIED WITH. COMPLIED WITH 51-900-1002-SKY TOOL USED TUC SDR SWIA202161368None · corroded*FLOOR SUPPORT PLATE HAS CORROSION. FS319.70 & STGR17R. (MARKED) (C-CHECK RO 9/27/2021) REPLACED FLOOR SUPPORT PLATE WITH NEW. REF CRJ-700 SRM 51-42-21-001-001-A01 REV 38 JUL 25/2020 AND DRAWING SH670-31950 REV Y COMPLIED WITH 51-900-1002-SKY. RESTORED SDR SWIA202161367None · corroded*FLOOR SUPPORT FITTING ON SUPPORT PLATE HAS CORROSION. FS319.70 & STGR17R. (MARKED) (C-CHECK RO 9/27/2021) REMOVED AND REPLACED FITTING. REF: CRJ-700 SRM 51-42-21-001-001-A01 AND DWG. SH670-31950 REV Y. RESTORED FINISH. REF: CRJ-700 [TR51-0068] SRM 51-SDR SWIA202161466None · bent* WHILE INSPECTING PASSENGER DOOR SURROUND STRUCTURE BELOW FLOOR DISCOVERED BENT FLOOR STRUCTURE INTERCOSTAL AT APPROX LBL 27 AND F/S 349 - 364 (C-CHECK RO 9/27/2021) REMOVED AND REPLACED PASSENGER DOOR SURROUND STRUCTURE BELOW FLOOR INTERCOSTAL AT APPSDR SWIA202161465None · none* WHILE INSPECTING PASSENGER DOOR SURROUND STRUCTURE BELOW FLOOR DISCOVERED BENT FLOOR STRUCTURE INTERCOSTAL AT APPROX LBL 27 AND F/S 333 - 349 (C-CHECK RO 9/27/2021) REMOVED AND REPLACED BENT FLOOR STRUCTURE INTERCOSTAL AT APPROX LBL 27 AND F/S 333 - 34SDR SWIA202161464None · bent* WHILE INSPECTING PASSENGER DOOR SURROUND STRUCTURE BELOW FLOOR DISCOVERED BENT FLOOR STRUCTURE INTERCOSTAL AT APPROX LBL 27 AND F/S 310-333 (C-CHECK RO 9/27/2021) REMOVED AND REPLACED PASSENGER DOOR SURROUND STRUCTURE BELOW FLOOR INTERCOSTAL AT APPROXSDR SWIA202161366None · corroded*CIRCUMFERENTIAL JOINT INTERFACE FS280.00 - FS282.86 HAS MULTIPLE AREAS OF CORROSION BETWEEN STGR27 €“ STGR18R. (C-CHECK RO 9/27/2021) BLENDED OUT CORROSION ON FS280 BUTTSTRAP (CIRCUMFERANTIAL JOINT) BETWEEN STRG26L AND STRG27 IAW CRJ700 SRM 51-21-06SDR SWIA202161365None · corroded* F/S 280 FLOOR PANEL SUPPORT ANGLE BETWEEN L & R 280 BULKHEADS IS CORRODED (C-CHECK RO 9/27/2021) REMOVED AND REPLACED FLOOR PANEL SUPPORT ANGLE P/N CC670-34095-1SB REF DWG NO. CC670-33052 REV -G AND CRJ700 SRM51-42-06-001-001-A01 AND SRM51-42-21-001-SDR SWIA2021100161364Stringer · corrodedEVIDENCE OF CORROSION IN MULTIPLE LOCATIONS ON STRING 20L BETWEEN FS 349.00 - 364.00 & 379.00 €“ 437.00 (C-CHECK RO 9/27/2021) COMPLIED WITH PERMANENT REPAIR 20L BETWEEN FS 349.00 - 364.00 & 379.00 €“ 437.00, SRM 51-42-21-001-001-A01, SRM 51-46-02-001SDR SWIA2021100161363Stringer · corrodedEVIDENCE OF CORROSION IN MULTIPLE LOCATIONS ON STRING 20R BETWEEN FS 364.00 €“ 394.00 (C-CHECK RO 9/27/2021) REPAIRED CORROSION ON STGR 20R BETWEEN F.S. 364.00 AND F.S. 394.00 PER MHIRJ REO 670-53-21-2082 REV -- DATED 2021-08-09, CRJ 700 SRM 51-42-06SDR SWIA202161362None · corrodedEVIDENCE OF CORROSION ON FRAME @ FS 333.00 BETWEEN STRINGERS 26R & 27 (C-CHECK RO 9/27/2021) REPAIRED FRAME FS333 FROM STGR 26R-STR 27. REF CRJ700 SRM 51-42-06-001-001-A01, CRJ700 SRM 51-42-21-001-001-A01,DWG SH670-32420 REV E,CRJ700 SRM 53-00-06-201-00SDR SWIA202161361None · corroded*STGR25R SPLICE ANGLE HAS CORROSION, FS333.00. (MARKED) (C-CHECK RO 9/27/2021) REPLACED STRINGER SPLICE LOCATED AT STR 25R AT FS333.00. REF CRJ700 SRM 51-42-06-001-001-A01,DWG SH670-32429 REV A. LEAK CHECK GOOD. COMPLIED WITH TASK CARD 51-900-1002-SKYSDR SWIA202161360None · corroded*STGR27 SPLICE ANGLE HAS CORROSION, FS333.00. (MARKED) (C-CHECK RO 9/27/2021) REPLACED STRINGER SPLICE AT STR 27 AT FS333.00 WITH NEW. REF CRJ700 SRM 51-42-06-001-001-A01,DWG SH670-32429 REV A, DWG SH670-32420 REV E. LEAK CHECK GOOD. COMPLIED WITHTASK CSDR SWIA202161359None · corroded*FRAME, FS295.00, LOWER FLANGE HAS CORROSION BETWEEN STGR26R - STGR25R. (MARKED) (C-CHECK RO 9/27/2021) REPAIRED FRAME LOCATED AT FS295.00 FROM STR 26R-STR 25R. REF DWG SH670-31630 REV. K, CRJ-700 SRM 53-00-06-201-006-A01 CRJ-700 SRM 51-42-06-001-001-ASDR SWIA202161463None · dentedL/H SLAT TRACK 2-1 HAS DENT ON OTBD LWR EDGE (MARKED IN RED) (C-CHECK RO 9/27/2021) REPLACED LH SLAT TRACK BRACKET WITH NEW. REF CRJ-700 SRM 51-41-02-001-001-A01SDR SWIA202161358None · corrodedL/H SLAT TRACK 2-1 HAS CORROSION (MARKED WITH RED) (C-CHECK RO 9/27/2021) REMOVED CORROSION ON LH SLAT TRACK 2-1. WITHIN LIMITS REF REO 670-57-42-1127 REV -- DATED 2021-07-26 ALL STEPS COMPLIED WITH. COMPLIED WITH 51-900-1002-SKY. TOOL USED TUC 4822 30SDR SWIA202161500None · corroded* RH INBD FLAP VANE ACTUATOR AT FLS24.0 UPPER MOUNT BOLTS CORRODED (MARKED) (C-CHECK RO 9/27/2021) INSTALLED 2EA NEW BOLTS ON THE VANE ACTUATOR AT FLS 24.0 REF CRJ 700 AMM 27-52-23-400-801-A01. OPS CHECK GOOD.SDR SWIA202161498None · corroded* RH INBD FLAP VANE ACTUATOR AT FLS65.5 UPPER MOUNT BOLTS CORRODED (MARKED) (C-CHECK RO 9/27/2021) INSTALLED 2EA NEW BOLTS ON THE VANE ACTUATOR AT FLS 65.5 REF CRJ 700 AMM 27-52-23-400-801-A01. OPERATIONAL TEST, CHECKED GOOD.SDR SWIA202161479None · worn*AFT CARGO DOOR HAS 3EA WORN RUBBER STOPS (C-CHECK RO 9/27/2021) REMOVED AND REPLACED 3EA WORN STOPS ON AFT CARGO DOOR TRACKS CRJ700 AMM 52-31-23-400-801-A01P/N CC670-39400-1 AND CC670-38798-5 AND 600-35166-3
Back to N708EV