What was found
* WHILE INSPECTING PASSENGER DOOR SURROUND STRUCTURE BELOW FLOOR DISCOVERED BENT FLOOR STRUCTURE INTERCOSTAL AT APPROX LBL 27 AND F/S 333 - 349 (C-CHECK RO 9/27/2021) REMOVED AND REPLACED BENT FLOOR STRUCTURE INTERCOSTAL AT APPROX LBL 27 AND F/S 333 - 349. REF CRJ700 SRM 51-42-06-001-001-A01. LEAK CHECK GOOD