N709EV
Service difficulty reports · 197
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N709EV' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N709EV' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASOA2014102411486Skin · dentedDENT ON LEFT NR 1 SLAT SS 135.75. FOUND TO BE OUT OF LIMITS IAW SRM 57-42-01-101-001-A01. REPAIRED IAW EA 25-2014-275 ITEM 3 COMPLIED WITH ITEM 4 .SDR ASOA2014082211132Angle · chafedFOUND CHAFING DAMAGE AT FS 1144.00 STR 9R CAUSED BY WATER SENSE LINE BONDING CLAMP. RECEIVED AND COMPLIED DISPOSITION REO 670-53-61-1084. THIS IS CLASSIFIED AS A MAJOR REPAIR, ALL STEPS ARE CONSIDERED RII. CUT AWAY DAMAGE AT FRAME 1144 BETWEEN STR8R AND STSDR ASOA2014082211131Battery Pack · inoperativeF/A FLASHLIGHT INOPERATIVE. R & R FLASHLIGHT BATTERIES AND OPS CHECKED IAW AMM 25-61-00.SDR ASOA2014071810894Megaphone · inoperativeMEGAPHONE DOESN'T WORK. R & R MEGAPHONE IAW AMM 25-61-14 5. OPS CHECKED GOOD.SDR ASOA2014071110852Lamp · burned outSIDE WALL LIGHT AT RT EMERGENCY EXIT IS OUT. R & R SIDE WALL LIGHT LAMP AT RT EMERGENCY EXIT IAW 33-21-07.SDR ASOA2014070710825Lamp · burned outOVERHEAD EMERGENCY LIGHT AT ROW 7 INOPERATIVE. REPLACED THE LAMP AT ROW 7 EMERGENCY LIGHT IAW AMM 33-51-09. OPS TESTED GOOD.SDR ASOA2014010309735Lamp · burned outINTERIOR CEILING EMERGENCY LIGHT AT 7 ABCD IS OUT. REPLACED LAMPS AND OPS CHECKED GOOD IAW AMM 33-51-00.SDR ASOA2013081408868Floor Panel · damagedDURING INSPECTION OF PRESSURE FLOOR PANEL AWL7 53-41-117. FOUND EXISTING DAMAGE AND BLEND OUT AROUND HYD UNION NR 3 ON LT SIDE UPPER SURFACE BETWEEN LBL 9.00 AND LBL 18.00 AND BETWEEN FS 693.00 AND 847.00. REPAIRED IAW REO 670-53-41-186. THIS IS CLASSIFIED SDR ASOA2013080508825Battery · dischargedON ARRIVAL TO THE ACFT WITH GROUND POWER DISCONNECTED, FOUND EMERGENCY LIGHTS SWITCH IN ARMED POSITION, EMERGENCY LIGHTS INOP. CHARGED EMERGENCY LIGHTS, OPS TEST GOOD IAW AMM 33-51-00. AC OK FOR SERVICE.SDR ASOA2013071708693Lens · crackedEMERGENCY LIGHT LENS ENTRY DOOR CRACKED. REPLACED EMERGENCY LIGHT LENS IAW AMM 33-51-15. ACFT OK FOR SERVICE.SDR ASOA2012113002584Warning Light · false activationAFT LAVATORY SMOKE WARNING ON APROACH, WARNING EXTINGUISHED AFTER APROX 4 MINUTES. INSPECTED AFT LAVATORY, NO SMOKE FOUND, TESTED LAVATORY SMOKE DETECTOR, OPS CHECKED GOOD IAW AMM 26-16-00. ACFT OK FOR SERVICE.SDR ASOA2012102302387Channel · corrodedFOUND LT LOWER FLIGHT DECK ENTERANCE JAMB AT LBL 9 CORRODED. FOUND CORROSION OUT OF LIMITS. COMPLIED WITH REO 670-53-11-745 IAW NDTM PT01, 51-20-006-250-A01 AND IAW NDTM PT01, 51-20-008-230-A01. FOUND TO BE SATISFACTORY.SDR ASOA2012101002341Doubler · crackedDURING REPLACEMENT OF FS 280 TRANSVERSE BEAM, FOUND BOTH LT & RT UPPER ANGLE DOUBLERS TO BE CRACKED APPROX 1 INCH LONG. LOCATED & DRILLED FASTENER HOLES FOR SERVICEBLE ANGLE DOUBLERS IAW SRM 51-40-11-001-001-A01. INSTALLED IAW SRM 51-42-06-001-001-A01 AND SSDR ASOA2012101002340Channel · corrodedFS 280 FWD "J" CHANNEL IS CORRODED BEYOND REPAIR. CORROSION GOES ALL THE WAY THROUGH THE PART. REMOVED CHANNEL IAW SRM 51-42-06-001-001-A01 & SRM 51-42-21-001-001-A01. LOCATED & DRILLED NEW CHANNEL IAW SRM TASK 51-40-00-001-001-A01. INSTALLED CHANNEL IAW SDR ASOA2012101002339Angle · corrodedPAX DOOR FWD CORNER CORRODED BEYOND LIMITS. REMOVED DAMAGED FWD CORNER IAW SRM 51-42-06-001-001-A01 AND 51-42-21-001-001-A01. INSTALLED PAX DOOR FWD CORNER IAW SRM 51-42-21-001-001-A01 & SRM 51-42-06-001-001-A01.SDR ASOA2012102302386Crossbeam · corrodedFS 280.00 CROSSBEAM CORRODED IN NUMEROUS AREAS. REMOVED CROSSBEAM IAW SRM 51-42-06-001-001-A01 & SRM 51-42-21-001-001-A01 & SRM 51-42-10-001-001-A01.SDR ASOA2012102302385Floor Support · corrodedRT FLOOR SUPPORT CORRODED FROM FS 280 - 319. REMOVED RT FLOOR SUPPORT FROM FS 280 TO 319 IAW SRM 51-42-06 & 51-42-21. LOCATED, DRILLED & INSTALLED NEW FLOOR SUPPORT IAW SRM 51-40-11-001-001-A01, SRM 51-42-06-001-001-A01 & SRM 51-42-13-001-001.SDR ASOA2012102302384Angle · corrodedSERVICE DOOR LOWER SILL AND ANGLE HAVE SEVERAL AREAS OF CORROSION. REMOVED SERVICE DOOR LOWER SILL AND ANGLE IAW SRM 51-42-06-001-001-A01. LOCATED, DRILLED AND SUBASSEMBLED THE NEW SILL ANGLE TO THE NEW UPPER ANGLE IAW THE SRM 51-40-11-001-001, 51-42-06-001-SDR ASOA2012101102342Sill · corrodedPAX DOOR SILL ANGLE HAS CORROSION AROUND FASTENER HOLES. REMOVED CORRODED PAX DOOR SILL ANGLE. LOCATED DRILLED NEW PARTS IAW SRM 51-40-11-001-001-A01, INSTALLED NEW PARTS IAW SRM 51-42-06-001-001-A01, 51-42-21-001-001-A01, 51-45-00-001-001-A01.SDR ASOA2012100502324Finger Doubler · corrodedRT FLOOR SILL FINGER DOUBLER FROM FS 295 TO FS 310 IS CORRODED. LOCATED AND INSTALLED NEW FINGER DOUBLER ON NEW RT FLOOR SILL IAW SRM 51-42-06-001-001-A01.SDR ASOA2012091402216Connector · disconnectedEMERGENCY LIGHT OVER GALLEY SERVICE DOOR INOPERATIVE. FOUND CONNECTOR AT GALLEY SERVICE LIGHT HAD PUSHED OUT. ATTACHED AND FUNCTION TESTED IAW AMM 33-50-00. NO FURTHER DEFECT NOTED.SDR ASOA201201701Glowstrip · missingF/A REPORTS PHOTOLUMINESCENT STRIPS MISSING IN FRONT OF FIRST CLASS CLOSET. INSTALLED LT AND RT PHOTOLUMINESCENT STRIPS IN FRONT OF FIRST CLASS CLOSET IAW AMM 33-51-01.SDR ASOA201002001Battery · weakAFT F/A FLASHLIGHT WEAK & INTERMITTENT. R & R AFT F/A FLASHLIGHT BATTERIES REF AMM 25-60-00.SDR ASOA201002000Battery · weakFWD F/A FLASHLIGHT WEAK & INTERMITTENT. R & R FWD F/A FLASHLIGHT BATTERIES, REF AMM 25-60-00.SDR ASOA201001999Battery · weakCAPT FLASHLIGHT WEAK & INTERMITTENT. R & R CAPT FLASHLIGHT BATTERIES REF AMM 25-60-00. (CLOSED)SDR ASOA201001634Crossbeam · corrodedCROSSBEAM FOUND TO BE CORRODED AT RT AND LT SIDE PANEL NUTPLATE LOCATIONS. INSTALLED 5 EA RIVETS CROSSBEAM IAW SRM 51-42-06-001-001-A01. RESTORED A023 FINISH IAW SRM 51-21-16-001-001-A01. APPLIED CIC AT REPAIRED AREA IAW SRM 51-21-11-001-001-A01.SDR ASOA201001580Lens · crackedBOTH EMERGENCY EXIT LIGHT LENS COVERS CRACKED ON WARDROBE AT ASD ENTRANCE. ( OPEN )SDR ASOA201001579Cover · crackedEMERGENCY EXIT LIGHT COVER CRACKED AT SERVICE DOOR (GALLEY ACCESS PANEL). (OPEN)SDR ASOA201001569Angle · corrodedSERVICE DOOR LOWER SILL ANGLE IS CORRODED OUT OF LIMITS. (OPEN)SDR ASOA201001561Seat Track · corrodedSIDE WALL SEAT TRACK HAS CORROSION JUST FWD OF RT EMERGENCY EXIT. REMOVED SEAT TRACK IAW AMM 53-00-000-801. INSTALLED SIDE WALL SEAT TRACK IAW AMM 53-00-49-400-801.SDR ASOA201001733Floorbeam · corrodedFS 349.00 BETWEEN RBL 9.00 AND RBL 18.00 FLOORBEAM HAS 1EA BROKEN AND CORRODED SCREW. R & R NUTPLATE AND SCREW IAW SRM CH 51-42-15-001-001. (CLOSED)SDR ASOA201001557Shim · corrodedFS 333.00, RBL 9.00, FLOORBEAM SHIM INBD AND OTBD ATTACH POINTS CORRODED. (OPEN)SDR ASOA201001556Floor Support · corrodedBETWEEN FS 319.00 AND FS 333.00, RBL 36.00 FLOOR SUPPORT HAS CORROSION. (OPEN)SDR ASOA201001555Floor Support · corrodedBETWEEN FS 349.00 AND FS 364.00 AT RBL 36.0, FLOOR SUPPORT SILL PLATE HAS CORROSION. (OPEN)SDR ASOA201001554Sill · corrodedBETWEEN FS 280.00 AND FS 319.70 AT RBL 36.00 FLOOR SUPPORT SILL PLATE HAS CORROSION. (OPEN)SDR ASOA201001553Bulkhead · corrodedFS 280.00 BULKHEAD LT AFT SIDE AT WL73.50 JUST ABOVE FLOOR SUPPORT STRUCTURE BETWEEN LBL9.00 AND LBL18.00 HAS CORROSION.SDR ASOA201001732Seat Track · corrodedSEAT TRACK 9R AT FS 581 TO FS 677 HAS MINOR SURFACE CORROSION. REMOVED SEAT TRACK AT 9R, FS 581 TO FS 697 IAW SRM51-41-02-001-001-A01. INSTALLED NEW SEAT TRACK. FABRICATED NEW SEAT TRACK USING SEAT TRACK EXTRUSTION PN N126-2075 6, TRIMED BACK UPPER FLANGE SDR ASOA201001731Floorbeam · corrodedLIGHT CORROSION ON THE FLOOR SUPPORT CHANNEL WHICH IS MOUNTED TO FS 280 FRAME BETWEEN STGR 26L AND 26R. R & R FLOORBOARD SUPPORT ANGLE AT FS280 BETWEEN STGR 26L AND 26RT PN CC670-34-256-3 IAW SRM 53-11-10-991-803 AND 51-42-06-001-001-A01 AND REAPPLIED A023 FISDR ASOA201001643Stringer Splice · corrodedREMOVED STRINGER SPLICE 25R AT FS 333 IAW SRM 51-42-06-001-001-A01. SPLICE WAS REMOVED AND FOUND TO BE CORRODED A SPLICE ORDERED AND RECEIVED. LOCATED AND DRILLED EXISTING HOLES IN NEW STRINGER SPLICE. INSTALLED NEW STRINGE SPLICE WET IAW SRM 51-42-06-00SDR ASOA201001543Floor Support · corrodedFLOOR SUPPORT CAP CORRODED UNDER SEAT TRACK FROM FS 698 TO FS 830.4. BLENDED CORROSION IAW SRM 51-12-00-001-001-A01. NO DAMAGE ALLOWED ON FLOOR SUPPORT CAP IAW SRM 51-41-00-001-001-A01.SDR ASOA201001542Floor Support · corrodedFLOORBEAM CAP CORRODED UNDER SEAT TRACK FROM APPROX FS 686 TO FS 698. REPAIRED IAW REO 670-53-41-109.SDR ASOA201001541Floorbeam · corrodedCORROSION ON TOP OF FLOORBEAM 9L AROUND SEAT TRACK AND FLOOR PANEL NUTPLATE HOLES AT FS 479. BLENDED CORRODED AREA. COMPLIED WITH NDT STEP 2 OF REO 670-53-31-177, NO INDICATIONS NOTED. COMPLIED WITH STEPS 3-5 OF REO 670-53-31-177.SDR ASOA201001540Crossbeam · corrodedBS 280 CROSSBEAM FOUND TO BE CORRODED AT RT AND LT SIDE FLOOR PANEL NUTPLATE LOCATIONS. FOUND DAMAGED AREA TO BE OUT OF LIMITS IAW SRM. REMOVED CROSSBEAM IAW SRM 51-42-06-001-001-A01, 51-42-21-001-001-A01, 51-42-13-001-001-A01. INSTALLED NEW CROSSBEAM IAW SRMSDR ASOA201001539Seat Track · corrodedSEAT TRACK 9L AT FS 379 TO FS 485 HAS CORROSION ON SIDE OF TRACK AND IS UNSERVICEABLE. REMOVED SEAT TRACK IAW AMM 53-00-49-000-801. INSTALLED SEAT TRACK IAW AMM 53-00-49-400-801.SDR ASOA201001538Seat Track · corrodedSEAT TRACK 9R AT FS 485 TO FS 581 CORRODED AND UNSERVICEABLE. REMOVED SEAT TRACK IAW SRM 51-47-02-001-0001-A01. INSTALLED NEW SEAT TRACK IAW AMM 53-00-49-400-801.SDR ASOA201001537Seat Track · corrodedSEAT TRACK 9 R AT FS 677 TO 83.40 IS CORRODED. REMOVED UNSERVICEABLE SEAT TRACK & INSTALLED IAW AMM 53-00-49-400-801.SDR ASOA201001536Lens · crackedRT FUSELAGE AFT EMERGENCY LIGHT LENS IS CRACKED. INSTALLED NEW LENS IAW AMM 33-51-15-400-801.SDR ASOA201001535Lens · crackedLT FUSELAGE AFT EMERGENCY LIGHT LENS IS CRACKED. R & R EMERGENCY LIGHT LENS IAW AMM 20-21-00-910-801.SDR ASOA201001038Lamp · inoperativeLT AFT EXT EMERGENCY LIGHT INOP. RELAMPED LT AFT EXT EMERGENCY LIGHT IAW AMM 33-51-15, OPS CHECK GOOD. (CLOSED)SDR ASOA201000711Seat Track · corrodedMAIN PASSENGER CABIN RT FLOOR SEAT TRACK STA 364 TO 549 HAS CORROSION. SEAT TRACK FOUND TO BE OUT OF LIMITS REMOVED SEAT TRACK RT STA 364 TO STA 485 RCVD NEW RT SEAT TRACK PN SHO670-32159-1, PO 30340005 AND INSTALLED RT SEAT TRACK IAW SRM 51-41-02. BLENDED RT
Back to N709EV