N742PS
Service difficulty reports · 263
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N742PS' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N742PS' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA201711019011Floor Panel · delaminatedDELAMINATION ON FLOOR PANEL 232EF. REPLACED THE FLOOR PANEL IAW SRM 53-12-00, AND IRM 9701 REVISION G.SDR AALA201711019010Floor Panel · delaminatedDELAMINATION ON FLOOR PANEL 221PF. REPLACED THE FLOOR PANEL IAW SRM 53-12-00-300-006, FIGURE 20106, AND IRM 9701 REVISION G.SDR AALA201711019006Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE. CORROSION ON AFT GALLEY FLOORBEAM AT Y1292, BETWEEN FR 64 AND FR 66. REPLACED FLOORBEAM PER SRM 51-72-11 AND DRAWING D53472815.SDR AALA201711019005Tray · crackedAIRCRAFT IN BASE MAINTENANCE. CRACK INDICATION ON AFT GALLEY TRAY AT STRINGER 23L, BETWEEN FR 60 AND FR 69. REPLACED TRAY PER SRM 51-72-11.SDR AALA201711079020Skin · saturatedAIRCRAFT IN BASE MAINTENANCE: LEFT HAND ELEVATOR UPPER SURFACE SKIN HAS TRAPPED WATER INDICATION ON ELEVATOR LOCATED AT 14.5 INCHES FROM RIB 1 AND 8 INCHES FROM THE TRAILING EDGE. REPAIRED ELEVATOR UPPER SURFACE SKIN PER SRM 55-21-11-300-005.SDR AALA201711079037Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE. DELAMINATION ON FLOOR PANEL 161NF. REPLACED FLOOR PANEL PER SRM 53-02-00 AND IRM 97010 REVISION G.SDR AALA201711019015Floor Panel · delaminatedDELAMINATION ON FLOOR PANEL 151CE. REPLACED THE FLOOR PANEL IAW SRM 53-02-00-300-011, FIGURE 20109, AND IRM 9701 REVISION G.SDR AALA201706279002Power Supply · faultyEMERGENCY LIGHTS POWER SUPPLY 11WL UNIT FAULTED.SDR AALA201705309003Line · dirtyDURING TAKE OFF ROLL, ENGINES STABILIZED AT 50% N1. ON SETTING THRUST TAKEOFF THE FLEX DETENT, THE NR 1 ENGINE SPOOLED NORMALLY TO TAKEOFF POWER. THE NR 2 ENGINE HESITATED CAUSING SEVERE YAW AND REJECTION OF TAKEOFF. BLEW OUT PS3 LINE. NO FOREIGN OBJECTS IN LISDR AALA201705229015Battery · dischargedFOWARD FLIGHT ATTENDANT BREAKAWAY FLASHLIGHT INOPERATIVE. REPLACED THE BATTERY .SDR AALA201705029027Cover · brokenR1 DOOR SLIDE COVER CRACKED. REPLACED R1 DOOR SLIDE COVER.SDR AALA201704219020Brake · weakRIGHT BRAKE VERY SPONGY, OK DURING TAXI, SPONGY ON LANDING ROLLOUT. MAINTENANCE CHECKED BRAKE SYSTEM IAW 32-42-00 AND BLED RIGHT VALVE IAW 870-052A. ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR AALA201703209034Damper · low pressureR2 DOOR DAMPER LOW PSI. SERVICED DOOR DAMPER IAW AMM 52-10-00.SDR AALA201703209033Damper · low pressureR1 DOOR DAMPER LOW PSI. SERVICED DOOR DAMPER IAW AMM 52-10-00.SDR AALA201703209031Damper · low pressureL2 DOOR DAMPER LOW PSI. SERVICED DOOR DAMPER IAW AMM 52-10-00.SDR AALA201703209029Damper · low pressureL1 DOOR DAMPER LOW PSI. SERVICED DOOR DAMPER IAW AMM 52-10-00.SDR AALA201701299010Fan · seizedAIRCRAFT WAS GROUNDED: FORWARD RECIRCULATION FAN IN AMBER ON CONDITION PAGE. ASO HAD A ELECTRICAL BURNING SMELL. MAINTENANCE FOUND LEFT RECIRCULATION FAN 15HG SEIZED AND EVIDENCE OF A BURNING SMELL. THE FAN WAS CONFIRMED TO BE THE SOURCE OF THE ODOR AND WAS RESDR AALA201608299006Floor Panel · crackedAIRCRAFT IN BASE MAINTENANCE: CABIN FLOOR PANEL 241MF CRACKED. REPLACED CABIN FLOOR PANEL 241MF IAW AMM 53-32-12.SDR AALA201608269006Box Beam · crackedAIRCRAFT IN BASE MAINTENANCE: LEFT SIDE BOX BEAM UPPER FLANGE 3RD FASTENER HOLE FROM THE FRONT HAS CRACK INDICATION AT FRAME 43 AND +Y1650. REPAIRED BOX BEAM IAW EO 5315Y066.SDR AALA201607259009Outflow Valve · faultedFLIGHT CREW REPORTED RECIEVEING A VENT SKIN VALVE ECAM FAULT AND WAS UNABLE TO PRESSURIZE THE AIRCRAFT. THE FLIGHT CREW DECLARED AN EMERGENCY AND AIRCRAFT LANDED SAFELY WITH NO FURTHER INCIDENT. MAINTENANCE ACCOMPLISHED A SUCCESSFUL AEVC SYSTEM TEST IAW AMMSDR AALA201504089015Door Frame · crackedC11 CHECK, EDDY CURRENT REVEALED 1.25" CRACK IN FRAME 68 AT STRINGER 8 IN THE FRAME WEB RADIUS ON RT AFT PAX DOOR FRAME. CRACK CUT OUT & REPLACED WITH FITTING IAW DWG R53420898 & EA 209678.SDR USAA2015032600003Slide · unserviceableC11 CHECK, SAFETY WIRE ON L1 DOOR SLIDE BAR BROKEN & RIVET SHEARED ON SLIDE BRACKET ATTACH POINT. R & R L1 DOOR ESCAPE SLIDE IAW JC 26L00025010.SDR USAA2015032500015Slide · unserviceableC11 CHECK, SAFETY WIRE BROKEN ON BACK OF THE L1 DOOR SLIDE. REPLACED THE L1 DOOR SLIDE IAW TASK CARD 26L00025010.SDR USAA2015030300004Lens · dislodgedFLOOR LIGHTING LENS AT SEAT 1C DISLODGED. REPLACED LENS.SDR USAA2015030100001Lens · missingEMERGENCY EXIT LENS AT ROW 1 LT MISSING. REPLACED EMER EXIT LENS AT ROW 1 LT.SDR USAA2015010500004Battery Pack · dischargedAFT RT FLIGHT ATTENDANT FLASHLIGHT BROKEN. REPLACED BATTERY PACK IN AFT RT FLIGHT ATTENDANT FLASHLIGHT ASSEMBLY.SDR USAA2014102100001Panel · faultyTHE OXYGEN PANEL AT ROW 2F WILL NOT DEPLOY MANUALLY. R & R PAX OXYGEN PANEL AT ROW 2DF. OPERATIONS CHECKED GOOD IAW AMM 35-21-41.SDR USAA2014061300015Lens · unsecureA RED LENS FOUND IN FWD GALLEY, LOOKS LIKE EMER TRACK LIGHTING. SECURED RED LENS ON FWD AISLE EMER TRACK LIGHTING.SDR USAA2014061100004Battery · dischargedCREW REPORTED THE FLIGHT ATTENDANT AFT FACING JUMP SEAT FLASHLIGHT INOPERATIVE. REPLACED AFT FLIGHT ATTENDANT FLASHLIGHT BATTERY, OPERATIONS CHECKED GOOD.SDR USAA2014053000004Lens · missingEMERGENCY LIGHT LENS MISSING AT ROW 1 LT. REPLACED EMER LIGHT LENS AT ROW 1 LT.SDR USAA2014022400021Lens · missingMAINTENANCE REPORTED THE WALL MOUNTED EMERGENCY EXIT LIGHT LENS BY R1 DOOR MISSING. MX REPLACED LENS IAW AMM 33-51-13, PB 401.SDR USAA2013121100007Coffeemaker · faultyAN ACRID ODOR COMING FROM FWD GALLEY, MAYBE COOLER FREON, SLIGHT EYE BURNING SENSATION. NOTICED ODOR AT IDLE THRUST IN DESCENT. ALL OTHER BLEED SYSTEMS CONFIGURED NORMAL. FLIGHT LANDED WITHOUT INCIDENT. ACCOMPLISHED JOB CARD 26L00021001, TROUBLE SHOT CABINSDR USAA2013121000011Unknown · odorAFTER LEVELING AT CRUISE LEAD FLIGHT ATTENDANT REPORTED A STRONG DIRTY SOCK CABIN ODOR LOCALIZED IN FWD CABIN FROM GALLEY BACK TO ROW 2. DURING DECENT LEAD CALLED AGAIN TO REPORT 2 FLIGHT ATTENDANT’S WITH HEADACHES & THE LEAD WAS FEELING DIZZY. ACCOMPLISHED SDR USAA2013120500006Light · shortedMAINTENANCE REPORTED THE MID LT EMERGENCY POWER SUPPLY UNIT FAULT DISPLAYED. FOUND LT OFF WING ESCAPE SLIDE LIGHTS SHORTED. REPLACED LT OVERWING ESCAPE SLIDE IAW AMM 25-62-42-401.SDR USAA2013120500005Power Supply · faultyMAINTENANCE COMPLETED SLIDE INSTALLATION UP TO STEP 6A, FOUND CIDS FAULT DURING TEST, LT FWD EMERGENCY POWER SUPPLY UNIT. REPLACED 11WL EMERGENCY POWER SUPPLY UNIT IAW AMM 33-51-13-401. OPERATIONS CHECKED OF EMERGENCY LIGHT SYS IAW AMM TASK 33-51-00-710-001-SDR USAA2013111800007Cover · missingCREW REPORTED ROW 22C, EMERGENCY EXIT LIGHT, FLOOR LEVEL, MISSING PLASTIC COVER. MAINTENANCE REPLACED ROW 22C EXIT LIGHT COVER.SDR USAA2013090900007Power Supply · inoperativeLEFT EMERGENGY EPSU FAULT. R & R LT EPSU IAW AMM 33-51-38.SDR USAA2013022700009Unknown · odorDURING CRUISE, EN ROUTE FROM LGA TO DCA, THE FLIGHT ATTENDANT'S REPORTED A DIRTY SOCK ODOR IN AFT GALLEY AREA. MAINTENANCE ACCOMPLISHED JOB CARDS. RAN ENGINES, APU AND CYCLED A/C PACK SYSTEMS. COULD NOT DUPLICATE. AIRCRAFT OK FOR SERVICE.SDR USAA2012122700006Oil System · lack of lubeFLIGHT CREW REPORTED A STRONG BURNING ODOR IN COCKPIT, FIRST CLASS CABIN AND REAR OF AIRCRAFT. MAINTENANCE CHECKED APU INLET, NO OBSTUCTIONS. FOUND NO LEAKS IN APU COMPARTMENT. PERFORMED OPERATIONAL CHECK OF APU. RAN APU WITH BLEED ON/OFF, APU GENERATOR ONSDR USAA2012121400005Cover · missingCREW REPORTED THE R2 DOOR EMERGENCY EXIT CHUTE BULBS ARE EXPOSED. MAINTENANCE INSTALLED LENS COVER.SDR USAA2012100100028Hinge Fitting · wornRON - RIGHT HORIZONTAL STABILIZER NR 6 ELEVATOR HINGE FITTING WORN. REMOVED AND REPLACED HINGE FITTING IAW B737 AMM 55-16-42-00-400-001A.SDR USAA2012100100027Hinge Fitting · wornRON - RIGHT ELEVATOR NR 1 HINGE FITTING WORN. REMOVED AND REPLACED FITTING IAW B737 AMM 55-16-42-00-001A.SDR USAA2011122100005Damper · out of adjust2S CHECK - OUT ADJUSTMENT DIMENSION "A" BETWEEN STRIKER LEVER & FINGER AT PASSENGER/CREW DOOR 831. PERFORMED ADJUSTMENT CLEARANCE J2 BETWEEN STRIKER LEVER & FINGER AT PASSENGER/CREW DOOR 831 IAW A319 AMM 52-13-14-820-002 ITEM 4.SDR USAA2011122800009Sill · corroded2S CHECK - CORROSION ON LOWER DOOR SILL BETWEEN FR66 TO FR68, S23R. REPAIRED LOWER DOOR SILL BETWEEN FR66 TO FR68, S23R IAW EA 133951.SDR USAA2011121400029Floor Panel · delaminated2S CHECK - DELAMINATION ON AFT CARGO FLOOR PANEL 151ZG BETWEEN FR56 TO FR58, BETWEEN Y765 TO -Y765. REPLACED AFT CARGO FLOOR PANEL 151ZG IAW A319 SRM 53-02-00, IRM 9701 REV G.SDR USAA2011121400028Floor Panel · delaminated2S CHECK - DELAMINATION ON AFT CARGO FLOOR PANEL 151VG BETWEEN FR53 TO FR56, BETWEEN Y765 TO -Y765. REPLACED AFT CARGO FLOOR PANEL 151VG IAW A319 SRM 53-02-00, IRM 9701 REV G.SDR USAA2011122000010Door Frame · cracked2S CHECK - CRACK INDICATIONS WERE FOUND IN THE EMERGENCY EXIT HATCH DOOR 834 SEGMENT NR 1 (BOTH FRAME SEGMENTS). REPLACED EMERGENCY EXIT HATCH DOOR 834 SEGMENTS IAW EO 5210Y228.SDR USAA2011121900029Angle · cracked2S CHECK - CRACK ON SEGMENT ANGLE OF DOOR 844 BETWEEN FR40 TO FR41 & BETWEEN BEAM 1 TO BEAM. REPLACED SEGMENT ANGLE OF DOOR 844 IAW EO 5210Y228.SDR USAA2011121600003Fitting · corroded2S CHECK - LEVEL 2 GALVANIC CORROSION ON UPPER SURFACE OF CENTER FITTING AT RIGHT FORWARD SERVICE DOORWAY BETWEEN FR16 TO FR20, S23R. REPLACED CENTER FITTING AT RIGHT FORWARD SERVICE DOORWAY IAW A319 SRM 51-72-11.SDR USAA2011120900019Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 231WG BETWEEN FR28 TO FR35 & BETWEEN Y254 TO Y765. REPLACED FLOOR PANEL 231WG IAW A319 SRM 53-12-00 & IRM 9701 REV G.