N752RA
Service difficulty reports not matched to an aircraft · 54
They name N752RA, but no registry record covers the date, the aircraft registered then was built later, or the report describes another aircraft. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N752RA' AND registry_match IS NULL ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N752RA' AND registry_match IS NULL ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA006122Control Cable · brokenRNO - DURING INSPECTION OF THE MECHANICAL STOPS THE LOWER STOP LUG ON THE HORIZONTAL JACKSCREW BROKE, DUE TO THE LOWER LIMIT SWITCH NOT SHUTTING OFF PRIOR TO HITTING THE LOWER STOP. UPON FURTHER INVESTIGATION, IT WAS DISCOVERED THE HORIZONTAL STABILIZER SHUTOSDR AALA006094Connector · disconnectedSFO - THIRTY SECONDS AFTER TAKEOFF, LEFT AND RIGHT AIR COND TEMP HIGH. LIGHTS CAME ON. COMPLETED ABNORMAL, NO HELP. CONTINUED PER MANUAL WITH PACKS IN HP BLEED OFF. FOUND CANNON PLUG OFF AND RESECURED CANNON PLUG. OK FOR SERVICE. RUN ENGINE. OPS CHECK OSDR AALA006022Coalescer Bags · contaminatedSMOKE IN CABIN WHEN APU AIR TURNED ON. REMOVED AND REPLACED LT AND RT WATER SEPARATOR COALESCER BAGS AND REMOVED, CLEANED AND INSTALLED LT AND RT SCUPPER DRAIN ASSY'S IAW MM 21-20-02. OPS CHECK OK. (X)SDR AALA006058Wire · looseOKC - EMERGENCY SEAT LIGHT AT ROW 23 INOPERATIVE. REWIRED WIRING AT SEAT IAW MD80 MM 33-51-11. SYSTEM OPS CHECK PERFORMED IAW 33-53-0. OPS CHECK SATISFACTORY. (M)SDR AALA006002Slide · dislodgedNRO - FORWARD GALLEY DOOR SLIDE FELL OUT. CONTAINER HOLDING IT SOMETIMES WOULD NOT LATCH SHUT. RE-INSTALLED FORWARD GALLEY DOOR SLIDE. OPS CHECK GOOD. (X)SDR AALA996052Connected · disconnectedSJC - FLT 11D EMERGENCY LIGHT OUT. RECONNECTED CANNON PLUG AT BULKHEAD. OPS CHECK GOOD. (M)SDR AALA996015Power Supply · inoperativeRNO - O/H EMERGENCY LIGHTS OUT AT STATION 1113. REMOVED AND REPLACED POWER SUPPLY R5-27, OPS CHECK GOOD. ALL WORK DONE PER MM. (M)SDR ORJA99146Battery Pack · dischargedAT SJC, EMERGENCY LIGHT AT ROWS 1 THROUGH 5, RIGHT SIDE, ILLUMINATED WILL NOT TURN OFF. REMOVED AND REPLACED FORWARD BATTERY PACK PER MM 33-53-00. OPS CHECK NORMAL. (M)SDR ORJA99145Wire · failedAT SJC, EMERGENCY LIGHTS AT ROWS 1 THROUGH 5 ARE ON, WILL NOT TURN OFF. TROUBLESHOT EMERGENCY EXIT LIGHTING SYSTEM FORWARD GALLEY. RIGHT LIGHT WIRING TO SEATS AT ROW 8 DEF, GROUNDING OUT ON SEAT TRACK AND AIR GRILL. REPAIRED WIRING IAW 20-50-01 MM. OPS CHESDR ORJA99144Battery Pack · dischargedAT SJC, EMERGENCY LIGHTS AT ROWS 1, 2, 3, 8, RIGHT SIDE ONLY, ILLUMINATED DURING FLIGHT. REMOVED AND REPLACED FORWARD BATTERY PACK NEXT TO FORWARD GALLEY DOOR. OPS CHECK NORMAL PER MM 33-53-00. (M)SDR ORJA99143Fuse · failedAT PDX, FIRST ROWS 1 THROUGH 9, AIRCRAFT RIGHT, EMERGENCY LIGHTS CAME ON IN 'ARM' AND 'OFF' POSITION OF SWITCH. REMOVED AND REPLACED FUSE AT RIGHT EMERGENCY LIGHTS. OPS CHECK NORMAL PER BRUCE INDUSTRIES MM 400-883 AND MM 33-0. (M)SDR ORJA99137Battery Pack · dischargedAT LAX, EMERGENCY ROW LIGHTS, AIRCRAFT RIGHT, ROWS 1 THROUGH 9, ARE ON WITH SWITCH IN ARM AND OFF. REPLACED BATTERY PACK LIGHT ASSEMBLY, CHECKS NORMAL. (M)SDR ORJA99136Battery Pack · dischargedAT SJC, FORWARD GALLEY EMERGENCY EXIT BATTERY PACK INOPERABLE. REMOVED AND REPLACED GALLEY EMERGENCY EXIT BATTERY PACK IAW 33-21-00. OPS CHECK GOOD. (M)SDR ORJA99135Battery · dischargedAT SJC, FORWARD SECTION OF EMERGENCY LIGHTS CAME ON DURING FLIGHT. REMOVED AND REPLACED FORWARD BATTERY AT EMERGENCY LIGHT MODULE IAW MM 33-53-00. OPS CHECK GOOD. (M)SDR ORJA9998Battery Pack · dischargedAT SJC, EMERGENCY TRACK LIGHTING FORWARD PART OF CABIN CAME ON IN FLIGHT. COULD NOT BE TURNED OFF. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACK IN FORWARD GALLEY. OPS CHECK GOOD. DONE IAW 33-50 MM. (M)SDR ORJA9984Switch · out of adjustAT LAS, GATE RETURN, WHEN THROTTLES ADVACED FOR TAKEOFF, FORWARD CARGO COMPARTMENT DOOR LIGHT CAME ON. TAKEOFF DISCONTINUED AT LOW SPEED. LIGHT WENT OUT DURING TAXI IN. ADJUSTED FORWARD CARGO DOOR SWITCH. OPS CHECK OK. (M)SDR ORJA9985Wire · brokenAT SJC, EMERGENCY LIGHT AT SEAT ON ROW 1 INOPERABLE. FIXED BROKEN WIRE AT SEAT ON ROW 1 EMERGENCY LIGHT. OPS CHECK GOOD. (M)SDR ORJA9986Battery Pack · dischargedAT BUR, EMERGENCY AISLE LIGHT ON ROWS 1-9 WILL NOT GO OUT. REMOVED AND REPLACED BATTERY PACK. OPS CHECK NORMAL. (M)SDR ORJA9982Battery Pack · dischargedAT BUR, EMERGENCY AISLE LIGHTS ON ROWS 1-9 WILL NOT GO OUT. REMOVED AND REPLACED BATTERY PACK. OPS CHECK NORMAL. (M)SDR ORJA9981Battery Pack · dischargedAT SJC, FORWARD GALLEY EMERGENCY LIGHT FOR EXIT INOPERABLE. REMOVED AND REPLACED EMERGENCY EXIT BATTERY PACK FROM FORWARD GALLEY. OPS CHECKS NORMAL. (M)SDR ORJA9958Battery Pack · dischargedAT SJC, FORWARD EXIT BATTERY PACK (EMERGENCY) IS BAD. REMOVED AND REPLACED EMERGENCY BATTERY PACK. OPS CHECK GOOD. (M)SDR ORJA9957Light · inoperativeAT SJC, EMERGENCY LIGHT AT ROW 16 INOPERABLE. REMOVED AND REPLACED LIGHT ASSEMBLY. OPS CHECK GOOD. (M)SDR ORJA9944Slide · failedAT PHX, R-1 DOOR EMERGENCY SLIDE FAILS. SLIDE LIGHT BATTERY OK PER MM 25-62-05. REPLACED EMERGENCY SLIDE ASSY WITH SERVICEABLE SLIDE ASSY. (X)SDR ORJA9930Battery Pack · dischargedAT PHOENIX, ROWS 15 THROUGH 18 EMERGENCY SEAT LIGHT INOPERABLE. TROUBLESHOT SYSTEM, FOUND LOW VOLTAGE ON BATTERY PACK AND CHARGED SYSTEM USING A/C POWER PER MM 33-53-00. SYSTEM OPERATIONS CHECK GOOD PER MM 33-53-00. (X)SDR ORJA9929Battery Pack · dischargedAT PHOENIX ON ROWS 1 THROUGH 9, EMERGENCY SEAT LIGHTING IS INOPERABLE. TROUBLESHOT SYSTEM, FOUND LOW VOLTAGE ON EMERGENCY BATTERY PACK. CHARGED SYSTEM PER MM 33-53-00. OPS CHECKS GOOD PER MM 33-53-00. (X)SDR ORJA9928Battery Pack · dischargedAT PHOENIX, R-1 DOOR EMERGENCY EXIT IDENTIFIER INOPERABLE. TROUBLESHOT SYSTEM, FOUND LOW VOLTAGE ON EMERGENCY BATTERY PACK. CHARGED SYSTEM PER MM 33-53-00. OPS CHECKS GOOD PER MM 33-53-00. (X)SDR ORJA9919Battery Pack · dischargedAT PHOENIX, AT ROWS 15 THROUGH 18 EMERGENCY SEAT LIGHTING WAS INOPERABLE, NEEDED TROUBLESHOOTING AND REPAIRING. TROUBLESHOT SYSTEM, FOUND LOW VOLTAGE ON BATTERY PACKS. CHARGED SYSTEM, USING A/C POWER PER MM 33-53-00. SYSTEM OPS CHECKED GOOD PER MM 33-53-00.SDR ORJA9918Battery Pack · dischargedAT PHOENIX IN ROWS 1 THROUGH 9 EMERGENCY LIGHTING WAS INOPERABLE, NEEDS TROUBLESHOT AND REPAIRED. TROUBLESHOT SYSTEM, FOUND LOW VOLTAGE ON EMERGENCY BATTERY PACK. CHARGED SYSTEM PER MM 33-53-00. OPS CHECK GOOD PER MM 33-53-00. (M)SDR ORJA9927Frame · corrodedAT PHOENIX LEVEL 2 CORROSION ON CAP OF FRAME AT FS 1062 IN AFT BAGGAGE PIT ABOVE S30. REMOVED CORRODED CAP. FABRICATED REPLACEMENT, TREATED AND PRIMED BARE METAL SURFACES. INSTALLED CAP IAW SRM REF 51-30-2. VERIFIED NO FURTHER CORROSION. (M)SDR ORJA9926Angle · corrodedAT PHOENIX LEVEL 2 CORROSION, LOWER CHORD ANGLE, STATION 1002, HAS CORROSION BEYOND LIMITS. REMOVED LOWER CHORD ANGLE 24542 1002. REMOVED TRACK SUPPORT ANGLES FOM. INSTALLED SPLICE, P/N 3936445-1 PO NR X9S454606. TRACK SUPPORT ANGLES TO BE INSTALLED ON WO SDR ORJA9904Engine · malfunctionedAT LAS ON TAKEOFF FROM LAS, RIGHT ENGINE WOULD NOT PRODUCE TAKEOFF POWER. COULD ONLY GET 1.6 EPR. ABORTED TAKEOFF. RETURNED TO GATE. INSPECTED NR 2 ENGINE INLETS AND EXHAUST, NO DEFECTS NOTED. INSPECTED AND CLEANED MOISTURE TRAPS. PERFORMED PER MM 71-00-SDR ORJA98325Switches · contaminatedIN LAS - TAKEOFF DISCONTINUED FOR SPOILER DEPLOYED ANNUNCIATOR. THROTTLES WERE ADVANCED BUT TAKEOFF POWER NOT REACHED, SPEED APPROXIMATELY 20 KTS. CLEANED THROTTLE BANK SWITCHES SPOILER LIGHT SYSTEM. OPS CHECK OK. (M)SDR ORJA97188Pt2 Line · leakingAIR TURN BACK DUE TO NR 2 ENGINE NOT PRODUCING NORMAL CLIMB POWER. LARGE SPLIT IN EPR WITH ALL OTHER INDICATIONS NORMAL. FOUND PT2 FLEX LINE FROM APRON TO BULKHEAD WITH INTERNAL LEAK. MAINTENANCE REQUEST FOR CHECK FLIGHT TO FL330 TO VERIFY FIX OF CHRONIC PRSDR ORJA97186Transmitter · failedEPR SPLIT AT ALTITUDE AS CLIMB CONTINUED, LT EPR CLIMBED OFF SCALE. REMOVED AND REPLACED PT2 LINE IN PYLON. LEAK CHECK, OPS CHECK GOOD. REMOVED AND REPLACED NR 1 EPR TRANSMITTER AS PRECAUTION. TESTED GOOD PER MM 77-11-01. AIRCRAFT RETURNED TO SERVICE. (MSDR ORJA9810Doubler · corrodedLEVEL 2 CORROSION, FOUND ON INTERNAL SKIN DOUBLER AND SHEAR TIE AT STATION 1030 BETWEEN L30 AND L29R. FABRICATED AND INSTALLED INTERNAL DOUBLER IAW DC-9 SRM 53-04 FIG 38. (M)SDR ORJA97140Coalescer Bag · dirtyFLIGHT ATTENDANT REPORTED BURNED RUBBER AND PAPER ODOR IN AFT CABIN. REMOVED AND REPLACED COALESCER BAGS IAW MM 21-30-10. AIRCRAFT RETURNED TO SERVICE. (X)SDR ORJA9737Battery Pack · dischargedMID CABIN OVERHEAD EMERGENCY LIGHT INOP. REPLACED BATTERIES IN PACK. OPS CHECK GOOD. (M)SDR ORJA9733Wheel · failedTHROUGH BOLT ON NR 1 MAIN WHEEL BROKEN. REMOVED AND REPLACED NR 1 MAIN WHEEL TIRE ASSEMBLY. (M)SDR ORJA9672Ground · looseMID CABIN EMERGENCY CEILING LIGHT INOP. RELAMPED, NO HELP. FOUND LOOSE GROUND STUD AT 5225. TIGHTENED STUD. OPS NORMAL. (M)SDR ORJA9655Fuse · blewEMERGENCY LIGHTS ROWS 16-18 OUT. INSTALLED NEW FUSE IN EMERGENCY POWER PACK, ROW 20 DEF. OPERATIONAL CHECK NORMAL. (M)SDR ORJA9654Battery Pack · dischargedROWS 12-15 SEAT MOUNTED EMERGENCY EXIT LIGHTS INOP. REPLACED BATTERY PACK. OPS CHECK GOOD. (M)SDR ORJA9641Power Supply · inoperativeAFT CABIN EMERGENCY LIGHT INOPERATIVE. REPLACED EMERGENCY LIGHT BATTERY POWER SUPPLY. OPS CHECK NORMAL. (X)SDR ORJA96013Power Supply · inoperativeINTERMITTENT OPERATION OF FORWARD CABIN FLOOR TRACK POWER SUPPLY. REMOVED AND REPLACED FORWARD CABIN FLOOR TRACK POWER SUPPLY DUE TO SUSPECTED INTERMITTENT OPERATION. OPS CHECKS OK. (M)SDR ORJA96009Power Supply · inoperativeROW 23 TO EMP. FLOOR TRACK LIGHTING INOPERATIVE. INSTALLED NEW POWER SUPPLY. OPS CHECK NORMAL. (X)SDR ORJA96002Battery Pack · dischargedEMERGENCY LIGHTS IN EMPENNAGE INOP. REPLACED BATTERY PACK. (X)SDR ORJA9573Eel Battery · dischargedEMERGENCY LIGHTING TRACK FLOOR LAMPS WILL NOT ILLUMINATE AT ROW 3 AND ROW 25. RELAMPED BOTH. OPS CHECK GOOD. (M)SDR ORJA9548Eel Battery · dischargedFORWARD EMERGENCY DOORS OVERHEAD LAMPS DIM. REMOVED AND REPLACED FORWARD EMERGENCY OVERHEAD LAMPS BATTERY PER ATA 33. OPS CHECK GOOD. (X)SDR ORJA9546Subfloor · corrosionFUSELAGE STA 200, LBL 10-20 SUB-FLOOR STRUCTURE, HAS LEVEL 2 CORROSION AS SEEN FROM E AND E BAY. REMOVED CORRODED AREA, FAB, AND INSTALLED DOUBLER PER SRM 53-01, FIGURE 4.SDR ORJA9545Support · corrodedLEVEL 2 CORROSION, ON SUPPORT STA 160 LBL 14-44 WL 200. REMOVED CORROSION AND TREATED PER SRM 51-10-3. CUT AREA FABRICATED DOUBLER AND FILLER PER SRM 51-01 AND INSTALLED PER SRM 51-10-4. (Z)SDR ORJA9544Seat Track · corrodedLEVEL 2 CORROSION, ON SEAT TRACK LBL 7 STA 150-200. FABRICATED AND INSTALLED STRAP DOUBLERS PER DWG SKB009418N00132. (Z)
Back to N752RA