N774UA
Service difficulty reports · 245
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N774UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N774UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2012062903441Rub Strip · damagedNR 2 ENGINE ACCOUSTICAL PANEL MISSING POTTING COMPOUND AT PREVIOUS REPAIR, APPROX 1 1 BY- 69647 :ITEM SHOULD READ FAN BLADE RUBSTRIP MISSING POTTING COMPOUND CF 605. SEE MM72-33-01-801 FOR REPAIR AND MM 72-33-01-601 FOR INSPECTION CHECK. NEED PCN840-0440, 84SDR UALA2012062903431Rub Strip · damagedNR 2 ENGINE ACCOUSTICAL PANEL MISSING POTTING COMPOUND AT PREVIOUS REPAIR, APPROX 11. ITEM SHOULD READ FAN BLADE RUBSTRIP MISSING POTTING COMPOUND CF 605 ^24JUN ORD RCF-P :SEE MM72-33-01-801 FOR REPAIR AND MM 72-33-01-601 FOR INSPECTION CHECK. NEED PCN840-04SDR UALA2012062203393Acoustic Panel · damagedNR 2 ENGINE ACCOUSTICAL PANEL MISSING POTTING COMPOUND AT PREVIOUS REPAIR, APPROX 11. ITEM SHOULD READ FAN BLADE RUBSTRIP MISSING POTTING COMPOUND CF605.SDR UALA2012061503288Pin · not seatedENGINE IGNITOR L1 LEFT ENGINE FAILED TO IGNITE USING IGNITOR 1. STATUS MSG-7441471 INACTV ES MODE MSG-7451471 INACTV ES MODE.
REF FIM 74-11-809, FOUND PUSH BACK PIN CONNECTOR D71074P PIN 5, RESEATED PIN & LOCKED INTO CONNECTOR, ACCOMPLISHED MAT IGNITION TESSDR UALA2012053103036Skin · dentedDENT AT DOOR 4R. ACCOMPLISHED SKIN LAP REPAIR 13 PER SRM AND ERCRA 5330-04215 AT C-02 VISIT. REPAIR IS LOCATED AT BS 2125 AT S24R AFT OF DOOR 4R.SDR UALA2012041702310Connector · dirtyCREW REPORT RIGHT ENGINE GENERATOR CONTROL EICAS MESSAGE DISPLAYED FOR 30 SECONDS. AHM SHOWS MESSAGE 24-31552 & MESSAGE INACTIVE. ACCOMPLISHED FIM TASK 24-11T807, ALL READINGS NORMAL. CLEANED ALL INVOLVED CONNECTORS. RAN NR 2 ENGINE, ALL NORMAL.SDR UALA2012031601722Structure · dentedDAMAGE TO AFT FUSELAGE RIGHT SIDE AT APPROX STN 2129. INTERNAL INSPECTION TO BE ACCOMPLISHED WITHIN 5 FLIGHT CYCLES, FOR DAMAGE TO AFT FUSELAGE RIGHT SIDE AT APPROX STN 2129. PTC NOW 12455 INSP TO BE ACCOMPLISHED ON OR BEFORE PTC 12460. DENT IS AT STN 2125 SDR UALA2012030601420Connector · improper partINCORRECT CONNECTOR INSTALLED AT STA 1080 RBL 90 BIN, CONNECTOR DM330XXE. REF FCD 3321-01019 REV A PG 26 ITEM 25. REPLACED CONNECTOR AT LOCATION 1080 RBL 90, IAW 20-72-25.SDR UALA2012030601413Seal · missingFOUND LEFT WING UPPER INBOARD FLAPERON SEAL MISSING. FOUND ABOUT 4 FEET MISSING. REPLACED FLAPERON SEAL.SDR UALA2012021700966Indicator · faultyF/O TRIM INDICATOR HAS A DOUBLE IMAGE. REPLACED F/O STAB POSITION INDICATOR PER MM.SDR UALA2012021300849Receptacle · dirtyFOUND INTERMITTENT SHORT IN P105 INTERGRATION PANEL BETWEEN CONN D4828J PIN B14 AND D4967J PIN A2. FAULT WAS AT D4828J WHEN PLUG WAS CONNECTED. CLEANED RECEPTACLE AND SHORT WENT AWAY. CK'D INTEGRITY OF PIN AND SOCKET FOR RETENTION AND FOUND TO BE OK. CK'D FSDR UALA2012020900785Ignition Switch · faultyRPL L ENG START SW. DUE TO CONTINUED HISTORY OF NR 1 ENG EEC POWERED WITH ENGINE SHUT DOWN, REPLACE THE L ENG START-IGNITION SWITCH (S80100) P/N AD45-004-3. LOCATED ON THE P5 OVERHEAD PNL. L ENG START SWITCH IAW LM2949 CALL OUT. ACP L ENG RUN, SWITCH OPS CKSDR UALA2012021700967Heat Shield · wornNR 1 ENGINE, NR 1, 2, 3, 4, 5 HEAT SHIELDS ARE BAD. PER MM HEAT SHIELDS 2, 3, 4, 5 ARE WORN BEYOND .005 LIMITS ON NR 1 NACELLE. REPLACED NR 2, 3, 4, 5 HEAT SHIELDS. NEW HEAT SHIELDS HAVE BEEN INSTALLED BULB SEAL ON NR 1 HEAT SHIELD ON NR 1 NACELLE IS BADLY SDR UALA2012020900786Modulating Valve · faultyFAMV L EICAS MSG RETURNED. MAINT TO ACP MEL 3611E. DF LEFT FAMV IAW MEL 3611 E. -CQT- :THIS FAN MOD VALVE ISSUE CAUSES ONE SEC OF CABIN TO BE VERY COLD AND CKPT TEMP TO BE DIFF TO CNTL. REPLACED L FAMV PER MM. OPS CHK OKAY.SDR UALA2012011800379Display · inoperativeCAPT'S ND DISPLAY IS INOPERATIVE. REPLACED ND DISPLAY, NO HELP. SUSPECT BAD DISPLAY SELECT PANEL. PANEL IS ON AOG#4958 PART NUMBER 483-0002. ALSO CPM-GG(M010) AND CPM-GG(M011) PER MAIN MESS 31-80221 NEEDS TO BE CHECKED. REPLACED LOWER CENTER DISPLAY UNIT.SDR UALA2012011300272Connector · damagedLEFT ENGINE HAS INDICATIONS THAT IT SHOULDN'T HAVE PRIOR TO ENG START. ACCOMPLISHED TROUBLESHOOTING AS PER WDM 73-21-18 PG 2 SHEET 1. RESEATED & CLEANED CONNECTORS D11031P, D4828P, D4819P AND D4967P. LEFT ENGINE ALL INDICATION NORMAL. PERFORMED LEFT ENGINESDR UALA2012010300054Engine · malfunctionedNR 1 ENGINE ISSUE. FOUND ON EPDC THAT ENG NR 1 EEC SHOWS POWERED ON EICAS DISPLAY, ALL ENG INDICATIONS ARE ON, ON GROUND FOR LEFT ENG WITHOUT EEC TEST SWITCH ENGAGED. DEPOWERED ACFT. CIRCUT BREAKERS RESET FROM EEC CONTROL. EDIU LT & RT. SWAPPED LT & RT EDIUSSDR UALA2011122907160Fan · failedELECTRICAL TYPE BURNING ODOR IN COACH CABIN. CREW SELECTED BOTH RECIRC FANS OFF AND ODOR CLEARED. TURNED FANS BACK ON AND ELECT BURNING ODOR RETURNED. REPLACED LEFT LOWER RECIRC FAN, NO FAULTS AND OPERATION NORMAL.SDR UALA2011120506680Battery · faultyLOWER EICAS STATUS MSG BATTERY CHARGER APU. REPLACED APU BATTERY AND CHARGER, SYSTEM CHECKS OKAY.SDR UALA2011112706456Heat Shield · damagedNR 2 ENGINE PYLON HEAT SHIELD. REPAIRED IAW EVA 81257-C ISSUED WITH APPROVAL FOR REPAIRS.SDR UALA2011112206442Coax · looseCAPT'S NAV DISPLAY INOPERATIVE. SUSPECT COAX COUPLER AT FAULT. PERFORMED TROUBLE SHOOTING FOR FIM, CHECKED FOR LOOSE COAX CONNECTION ON LEFT COAX COUPLERS B31117 AND B31118. RESET COAX CONNECTIONS, CHECKED GOOD. POWER GOOD AT CAPT NAVIGATIONAL DISPLAY, ANDSDR UALA2011112106412Smoke Detector · faultyEICAS HAS A ZONE 2 AFT CARGO DET MESSAGE. REPLACED LOWER CARGO SMOKE DETECTOR PER AMM, OPS CHECKS GOOD.SDR UALA2011101305570Pbe · damagedPBE AT DOOR 4R IS SOFT. REPLACED PBE.SDR UALA2011101305565Isolation Valve · failedLEFT ISOLATION VALVE FAILED TEST. M MSG 36-10300 DISPLAYED, VALVE ON ORDER. REPLACED ISOLATION VALVE LEAK AND OPS CHECKED GOOD.SDR UALA2011101205547Generator · faultyAPU GENERATOR INOP ON PUSHBACK MNT MSG 24-31613 DISPLAYED. DEFERRED DUE TIME, APU GENERATOR PCN 661-9003 REQUIRED. -INF- :MESSAGE 24-31513 APU GEN EXCITER FIELD CURRENT OUT OF RANGE. (PARTS 661-9003 MR24223 GENERATOR ASSY). APU GENERATOR 2ND CONDUCTOR WISDR UALA2011093005294Bushing · out of positionLEFT MLG FWD DRAG BRACE UPPER SPINDLE BUSHING HAS ROTATED. A VISUAL INSPECTION HAS BEEN PERFORMED AND TORQUE STRIPE APPLIED TO BUSHING PER MM.SDR UALA2011091404975Charger · faultyEICAS MSG MAIN BATTERY DISC. FOUND P320 K9 TRIPPED, MAIN BATTERY CHARGER PWR CB. REPLACED MAIN SHIPS BATTERY AND BATTERY CHARGER.SDR UALA2011082904593Pbe · unserviceableFOUND PBE AT 4RT MED SEAL BROKEN. REPLACED PBE.SDR UALA2011080304046Battery · faultyAPU BATTERY APU BATTERY FAILURE. STATUS MSG01- ACTIVE CRUISE MODE DEPENDENT; APU BATTERY IS WEAK. DB- ELMS P310 ELECTRONICS UNIT MSG-2413047 ACTIVE ER MODE. MAT SHOWS MTC MSG 24-13047. APU BATTERY STS MSG SHOWING. APU BATTERY DEFERRED PER MEL 2431 C. RESDR UALA2011080304045Charger · faultyBAT CHARGER APU APU BATTERY CHARGER FAILURE. STATUS MSG01-ACTIVE CRUISE MODE DEPENDENT; APU BATTERY IS WEAK. DB- ELMS P310 ELECTRONICS UNIT MSG02- ACTIVE CRUISE MODE DEPENDENT; APU BATTERY IS WEAK. MSG-2413047 ACTIVE ER MODE MSG-2413047 ACTIVE ER MODE. STSDR UALA2011072703872Lens · unsecure8J CEILING LIGHT HANGING LOOSE. SECURED & REINSTALLED LENSE.SDR UALA2011072503810Lock · faultyDOOR 3L FWD LAV DOOR WILL NOT LOCK. REPLACED DOOR ASSY.SDR UALA2011072203731Pbe · damagedPBE DOOR 4L IS SOFT. REPLACED PBE DOOR.SDR UALA2011072203730Pbe · damagedPBE DOOR 4R IS SOFT. REPLACED PBE DOOR.SDR UALA2011070603351Pcu · faultyFLT CTL SYSTEM FAULT DISPLAYED ON STATUS. AHM SHOWS LEFT INBD FLAPERON PCU COMMAND ISSUE. REF MSG 27-10300 FIM TASK 27-11 TASK 814. REPLACED LEFT INBD FLAPERON PCU PER MM. OPS CHECK GOOD, LEAK CHECK GOOD & TEST PASSED. CYCLED FLAPS & AILERONS, NO MESSAGES SDR UALA2011070603344Relay · failedSTATUS MSG 'HEAT PITOT C' DISPLAYED AFTER GROUND POWER FELL OFF ACFT. REPLACED RELAY K3016 PROBE AIR HEAT CTRL PER FIM. MSG CLEARED, TEST PASS.SDR UALA2011060302708Drain Line · damagedLEFT PACK WATER EXTRACTOR WATER DRAIN LINE HAS PIN HOLE ON IT. DEFERRED PER MEL 2151B. LEFT PACK INOPERATIVE. REMOVED AND REPLACED DAMAGED LINE. LEAK CHECK C-OUT. NO LEAKS. PACK OPS SATISFACTORY.SDR UALA2011052302524Control Unit · malfunctionedEICAS MSG "HYD PRESS PRI C1" FAULT DISPLAYED. CREW CYCLED SW AND FAULT REOCCURED. DISCONNECTED CAP AND STOWED CONNECTOR J8, ON P100 PANEL PER MEL. MSG 2912015 HIT 2 LEGS BEFORE SYSTEM DEACTIVATED. REPLACED ELCU M29303 & TESTED REF MM, SYSTEM TESTS NORMAL.SDR UALA2011052302510Solenoid · malfunctionedENG CONTROL L EICAS MESSAGE. ACCOMPLISHED FIM 75-32 TASK 813. REPLACED 2.9 BLEED VLV SOLENOID PER MM. APPLIED 10 PSI TO 2.9 START BLD VALVE MUSCLE PRESS PORT AND VERIFIED VALVE OPENED AND CLOSED FREELY. ACP ENG TEST 12. ALL INDICATIONS WERE NORMAL. MSG CSDR UALA2011052302511Amplifier · failedSATCOM HI GAIN SATCOM HI GAIN IS FAILED. STATUS MSG01- ACTIVE ENGINE START HARD;SATELLITE DATA UNIT (LEFT) HAS NO INPUT FROM HIGH POWER AMPLIFIER FOR HGA (LEFT) ON BITE BUS. DB- SATELLITE DATA UNIT (LEFT) MSG-2360291 ACTIVE ES HARD. ITEM ALREADY DEFERRED SSDR UALA2011050202151Transducer · faultyFLT CTL SYS STATUS MSG SHOWN. REPLACED RT PRESSURE TRANSDUCER, NO HELP. REPLACED RIGHT ACMP PRESSURE TRANSDUCER. EICAS MESSAGE DID NOT RETURN AFTER RIGHT SYSTEM PRESSURIZED. REPLACED EDP PRESSURE TRANSDUCER. EICAS MESSAGE DID NOT RETURN.SDR UALA2011031801303Windshield · crackedCAPT WINDSCREEN DELAMINATING TOP RIGHT AND ALONG BOTTOM. SAMC TEXT: PER CREW, DELAMINATION AT L1 WINDOW IS 5X3 AND 1X6, DOES NOT AFFECT VISION. NEED TO CHECK PER MM. FOUND CRACKED ALONG TOP EDGE NEXT TO DELAM AREA. REMOVED AND REPLACED WINDSCREEN.SDR UALA2011030701092Light · inoperative1 SEAT MOUNTED EMERGENCY EXIT LIGHT AT SEAT 1F IS INOPERATIVE. RELAMPED, OPS CHECKS GOOD.SDR UALA2011012600423Circuit Card · malfunctionedFLT CONTROL SYS MESSAGE ON STATUS FOUND ON ETOPS CHECK. FLT CONTROL SYS MESSAGE APPEARS AND WILL DISAPPEAR BY TURNING ON AND OFF THE HYD SYS LT, CTR & RT. WHEN PRESSURE IS OFF MESSAGE APPEARS. WHEN PRESSURE IS ON MESSAGE GOES AWAY, REPLACED B31208 COUPLER IAWSDR UALA2011011200202Control Unit · faultySTATUS MESSAGE FLIGHT CONTROL SYS SHOWING ON LOWER EICAS. REPLACED RIGHT WING OUTBOARD AILERON POWER CONTROL UNIT AS PER AMM. AFTER AILERON ADJUSTMENT (RIGGING), OPERATIONAL TEST AND RIGHT AILERON ACTUATOR CONFIDENCE TEST, NO FURTHER MESSAGES PRESENT. ALL TESSDR UALA2010120204432Valve · faultySTATUS MESSAGE DISPLAYED BLEED FAMV R. DEFERED DUE TIME RT FAMV LOCKED IN THE OPEN POSITION. PRECAUTIONARY PAC ORDER PLACED FOR HIGH PRESSURE CONTROLLER 646-9027 - R5035. VALVE 646-9012 IS ALSO ON PRECAUTIONARY PAC ORDER - D4709 - NONE AVAILABLE STATESIDE. SDR UALA2010111904275Wedge · delaminatedNR 9 SLAT WEDGE DELAMINATED AT IB TRACK AREA. TEMP INJECTION REPAIR ACP AND ULTRASONIC VERIFIED NO DISBOND. REMOVED THE SLAT, BONDING REPAIRED PER SRM. TOUCH UP PAINT PER AMM. REINSTALLED THE SLAT PER AMM. ADJUSTED AND OPS TEST OKAY.SDR UALA2010111904276Battery Pack · brokenBATTERY PACK BROKEN AT LT NR 1 DOOR EPAS BATTERY PACK. REMOVED AND REPLACED BATTERY PACK IAW MM.SDR UALA2010081703010Line · leakingHYD LEAK IN RT MAIN WHEEL WELL, FOUND HYD LINE BURST AT RT ANTI-SKID SHUTTLE VALVE, FWD FLEX LINE JUST OTBD FROM RT MAIN GEAR TRUNNION. INSTALLED INTERIM REPAIR LINE IAW GNMM. LEAK CK OK. HYD SYS SERVICED. REPLACED PERMANENT HYD LINE, NO LEAKS NOTED.SDR UALA2010073002748Transducer · reads lowCREW OXYGEN LOW EICAS O2 PRESS FLUCTUATING FROM 0 TO +1600. CHECKED O2 VALVE IS OPENED AND PRESSURE IS 1750 PSI. INSTALLED NEW TRANSDUCER, READING ARE MATCHING TANK AND FILLER. NO FLUCTUATING.