N784UA
Service difficulty reports · 181
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N784UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N784UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026031814638Engine · abnormalLEFT ENGINE EGT EXCEEDANCE ON TAKE OFF. MAX EGT 700 CONFIRMED IAW AMM 72-00-00-290-828-N02, ENGINE EGT EXCEEDANCE TO 700C FALLS IN ZONE C PER FIGURE 603 SHEET 2. ZONE C EXCEEDANCE DIRECTS TO REMOVE ENGINE WITH NO BORESCOPE NEEDED. NR 1 ENG REMOVED FROM ACFT. SDR CALA2026012813403Wire · brokenSEAT 41G TRIM PIECE FELL OFF WITH BROKEN WIRE. REPLACED THE LIGHT AND INSTALLED THE TRIM PIECE. THE LIGHT OPS CK GOOD IAW AIPC 33-51-05-16.SDR CALA2026011612994Battery · dischargedCABIN EMERGENCY LIGHT FOUND INOP ON DOOR 3 ATTENDANT CREW REST CLOSET REF HAECO NON-ROUTINE 9493192, SUPPORT TASK. BATTERY LOW VOLTAGE, REPLACED THE POWER SUPPLY (M33099) BATTERY AND BATTERY CHARGER, THEN CARRIED OUT INSTALLATION TEST AND OPERATIONAL TEST, THSDR CALA2026011312919Battery · dischargedM/D L2 DOOR FWD EMERGENCY POWER SUPPLY (M33096) BATTERY PACK FOUND LOW CAPACITY REF HAECO NON-ROUTINE 9490429, REPLACED M/D L2 DOOR FWD EMERGENCY POWER SUPPLY (M33096) BATTERY PACK AND PERFORMED NEW BATTERY PACK TEST & CAPACITY CHECK, THE TEST RESULT NORMAL ISDR CALA2026011312918Battery · dischargedLLAR EMERGENCY POWER SUPPLY BATTERY PACK FOUND LOW CAPACITY REF HAECO NON-ROUTINE NO.9490431, REPLACED LLAR EMERGENCY POWER SUPPLY BATTERY PACK AND PERFORMED NEW BATTERY PACK TEST & CAPACITY CHECK, THE TEST RESULT NORMAL IAW AMM 33-51-06-960-802 & AMM 33-51-0SDR CALA2026011312917Battery · dischargedMAIN DECK R1 DOOR EMERGENCY POWER SUPPLY M33094 BATTERY PACK FOUND TO HAVE LOW CAPACITY IAW HAECO NON-ROUTINE 9490428, REPLACED MAIN DECK R1 DOOR EMERGENCY POWER SUPPLY M33094 BATTERY PACK AND PERFORMED NEW BATTERY PACK TEST & CAPACITY CHECK, THE TEST RESULTSDR CALA2025070106116Bottle · no discrepancyDR 3L SLIDE GAUGE IN RED INSPECTED DR ASSIST SLIDE BOTTLE GAUGE. ARM IS STILL LOCATED IN GREENSDR CALA2024101702670Battery Pack · dischargedM/D R2 DOOR EMERGENCY LIGHT BATTERY PACK M33098 FOUND LOW CAPACI TY DURING CAPACITY CHECK REFER HAECO NON-ROUTINE LOG PAGE:949659 1,ORIGINATED BY EMP:V903218,SPEC NO.B777-33-3-7019. PERFORMED BY EMP:V903218,REPLACED THE M/D R2 DOOR M33098 EMERGEN CY LIGHT BATTSDR CALA2024101702669Battery Pack · dischargedR4 DOOR M33409 BATTERY PACK FOUND LOW CAPACITY DURING TEST REFER HAECO NON-ROUTINE LOG PAGE:9496593,ORIGINATED BY EMP:V903218,SPE C NO.B777-33-3-7019. PERFORMED BY EMP:V903218,REPLACED R4 DOOR M33409 BATTERY PACK AN D C/O NEW BATTERY PACK TEST. THE RESULT NORMSDR CALA2024071800242Access Panel · missingPDA 2 R/H ENGINE STRUT PRESSURE RELIEF DOOR/ACCESS PANEL 443CL FOUND MISSING ON ARRIVAL. PHOTO ADDED. NIL STOCK LHR. CDL APPLIED. DISPATCH DESK: 67 NAME: AC DATE: 19-MAR-24- OK TO PLACE PDA 2 R/H ENGINE STRUT PRESSURE RELIEF DOOR/ACCESS PANEL 443CL FOUND MISSDR CALA2024032200832Access Panel · missingPDA, R/H ENGINE STRUT PRESSURE RELIEF DOOR/ACCESS PANEL 443CL FOUND MISSING ON ARRIVAL. PHOTO ADDED. NIL STOCK LHR. CDL APPLIED. CDL APPLIED. SDR RAISED #1035496 DISPATCH DESK: 67 NAME: AC DATE: 19-MAR-24- OK TO PLACE PDA 2 R/H ENGINE STRUT PRESSURE RELIEF DOOSDR CALA2023122603724Circuit Card · failedAI CARD EICAS STATUS WING ANTI-ICE (WAI) CONTROL CARD FAILURE. FIM TASK REF : FIM TASK REFERENCE NOT FOUND CMC MSG# 3018893 FLIGHT STATUS: A INTERMITTENCE CODE: H PH: CRUISE NARRATIVE: ARINC SIGNAL GATEWAY (L EFT), RSCF CARD, ASSY, AIR OFF 27-3011-9-0001 0122 SDR CALA2023051501497Fairing · brokenENGINE 1, LPC 1ST STAGE FAN BLADE FAIRING (AFT HALF), IN BETWEEN FAN BLADE 20 AND 21, WITH A WHITE DOT ON THE AIRFLOW SURFACE HAS DEPARTED AIRCRAFT. NO EVIDENCE OF FOD, AS INSPECTED FROM OUTSIDE WITH A FLASHLIGHT HAS ENTERED THE CORE. FOUND 3 DAMAGES ON RUBSTRSDR CALA2023040401019Battery · failedB777-33-3-7019 LLAR EMER LIGHT BATTERY CAPACITY CHECK FAIL. TRANSFER REF. NON-ROUTINE HX NRC WO.1582466 AND ORIGINATED BY EMP V898181. LLAR EMER LIGHT BATTERY REPLACED AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECHANIC V898181 INSPECTED BY SDR CALA2023040300997Battery · failedB777-33-3-7019 DR R3 EMER LIGHT BATTERY M33404 CAPACITY CHECK FAIL. TRANSFER REF. NON-ROUTINE HX NRC WO.1582473 AND ORIGINATED BY EMP V898181. DR R3 EMER LIGHT BATTERY M33404 REPLACED AND TESTED NORMAL AS PER AMM33-51-06. WORK ACCOMPLISHED BY MECHANIC V898181SDR CALA2023040300996Charger · failedB777-33-3-7019 DR R2 EMER LIGHT BATTERY CHARGER M33097 TEST FAIL. TRANSFER REF. NON-ROUTINE HX NRC WO.1591852 AND ORIGINATED BY EMP V898181. DR R2 EMER LIGHT BATTERY CHARGER M33097 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06. ATTACH FORM 44-0008 ITEM 1 TO SDR CALA2023040300995Charger · failedB777-33-3-7019 DR R1 EMER LIGHT BATTERY CHARGER M33094 TEST FAIL. TRANSFER REF. NON-ROUTINE HX NRC WO.1668731 AND ORIGINATED BY EMP V898181. DR R1 EMER LIGHT BATTERY CHARGER M33094 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECHANIC SDR CALA2023040300994Battery · failedB777-33-3-7019 DR R1 EMER LIGHT BATTERY M33094 CAPACITY CHECK FAIL. TRANSFER REF. NON-ROUTINE HX NRC WO.1582468 AND ORIGINATED BY EMP V898181. DR R1 EMER LIGHT BATTERY M33094 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.WORK ACCOMPLISHED BY MECHANIC V89818SDR CALA2023040300993Battery · failedB777-33-3-7019 DR R3 EMER LIGHT BATTERY M33401 CAPACITY CHECK FAIL. TRANSFER REF. NON-ROUTINE HX NRC WO.1582469 AND ORIGINATED BY EMP V898181. DR R3 EMER LIGHT BATTERY M33401 REPLACED AND TESTED NORMAL AS PER AMM33-51-06. WORK ACCOMPLISHED BY MECHANIC V898181SDR CALA2023040300992Battery · failedB777-33-3-7019 DR L3 EMER LIGHT BATTERY M33400 CAPACITY CHECK FAIL. TRANSFER REF. NON-ROUTINE HX NRC WO.1582476 AND ORIGINATED BY EMP V898181. DR L3 EMER LIGHT BATTERY M33400 REPLACED AND TESTED NORMAL AS PER AMM33-51-06. WORK ACCOMPLISHED BY MECHANIC V898181SDR CALA2023040300991Battery · failedB777-33-3-7019 DR L1 EMER LIGHT BATTERY M33424 CAPACITY CHECK FAIL. TRANSFER REF. NON-ROUTINE HX NRC WO.1582477 AND ORIGINATED BY EMP V898181. DR L1 EMER LIGHT BATTERY M33424 REPLACED AND TESTED NORMAL AS PER AMM33-51-06. WORK ACCOMPLISHED BY MECHANIC V898181SDR CALA2022093002582None · failed*EMERGENCY DECLARED *OUTFLOW VALVE AFT EICAS ADVISORY AUTO CONTROL ON AFT OUTFLOW VALVE FAILED OR MANUAL MODE FOR AFT OUTFLOW VALVE SELECTED. FIM TASK REF : FIM TASK REFERENCE NOT FOUND CMC MSG# 2139040 FLIGHT STATUS: A INTERMITTENCE CODE: M PH: CLIMB. NARRATSDR CALA2022092302488None · nonePANAL 511AB NEEDS ALUMINUM FOIL TAPE REPAIR IAW AMM TASK 51-27-01-340-801 IN COMPLIANCE WITH SRM 51-70-14-2R AND RII CLEAR TO INSTALL REPAIR IN COMPLIANCE WITH REF SRM 51-70-14-2R-3 AND RII. CLEAR REPAIR TO INSTALL PANAL 511AB TAPE AND ADHESIVE REMOVED IN REF.SDR CALA2022092302487None · noneWING L/E FOIL MESH INSPECTION TO BE ACCOMPLISHED PRIOR TO DEPARTURE. LOCKED UNLOCKED BY TOMC FOR DISPOSITION ITEMS CLEARED IAW WORK CARD 27-0520-8-0021 ITEMS HAVE BEEN REPAIRED AND ARE IN COMPLIANCE WITH SRM51-70-14-1A-0 AND RIISDR CALA2022092302486None · nonePANAL 511MB NEEDS ALUMINUM FOIL TAPE REPAIR IAW AMM TASK 51-27-01-340-801 IN COMPLIANCE WITH SRM 51-70-14-2R AND RII CLEAR TO INSTALL ACP RII INSPECTION OF REPAIR AND EDGE SEAL OK TO INSTALL PANEL REPAIR PANEL TAPE AND ADHESIVE REMOVED IN REFERENCE WITH SRM ASDR CALA2022092302485None · nonePANAL 511LB NEEDS ALUMINUM FOIL TAPE REPAIR IAW AMM TASK 51-27-01-340-801 IN COMPLIANCE WITH SRM 51-70-14-2R AND RII CLEAR TO INSTALL ACP RII INSPECTION OF REPAIR AND EDGE SEAL OK TO INSTALL PANEL REPAIR REMOVED OLD TAPE AND CLEANED PANEL. AWAITING INSPECTIONSDR CALA2022092302484None · nonePANAL 511NB NEEDS ALUMINUM FOIL TAPE REPAIR IAW AMM TASK 51-27-01-340-801 IN COMPLIANCE WITH SRM 51-70-14-2R AND RII CLEAR TO INSTALL ACP RII INSPECTION OF REPAIR AND EDGE SEAL OK TO INSTALL PANEL REPAIR PANEL TAPE AND ADHESIVE REMOVED IN REFERENCE WITH SRM ASDR CALA2022092302483None · nonePANAL 511EB NEEDS ALUMINUM FOIL TAPE REPAIR IAW AMM TASK 51-27-01-340-801 IN COMPLIANCE WITH SRM 51-70-14-2R AND RII CLEAR TO INSTALL ACP RII INSPECTION OF REPAIR AND EDGE SEAL OK TO INSTALL PANEL REPAIR PANAL TAPE AND ADHESIVE REMOVED IN REFERENCE WITH SRM PSDR CALA2022092302482None · noneRII INSPECTION REQUIRED REFERENCE CARD 27-0520-8-0018 LH WING LEADING EDGE PANELS FOIL MESH INSPECTION REQUIRES INSPECTION BY BACK PER GMM - 03-20-20. ITEMS CLEARED IAW WORK CARD 27-0520-8-0021 . ITEMS HAVE BEEN REPAIRED AND ARE IN COMPLIANCE WITH SRM51-70-14SDR CALA2021080401250Battery Pack · dischargedLLAR BACK-UP LIGHT BATTERY PACK DOESN''T OPERATE DURING FUNCTIONA L TEST REF HAECO NON-ROUTINE NO.9446466,ORIGINATED BY EMP V90535 9,SPEC NO.B777-33-3-7024. PERFORMED BY EMP V905359,REPLACED LLAR POWER SUPPLY BATTERY PACK AND CARRIED OUT LIGHT TEST,THE RESULT SDR CALA2021080401249Battery Pack · dischargedLLAR BACK-UP LIGHT BATTERY PACK DOESN''T OPERATE DURING FUNCTIONA L TEST REF HAECO NON-ROUTINE NO.9450068,ORIGINATED BY EMP V90535 9,SPEC NO.B777-33-3-7024. PERFORMED BY EMP V905359,REPLACED LLAR POWER SUPPLY BATTERY CHAR GER AND CARRIED OUT LIGHT TEST,THE RESSDR CALA2021080401248Battery Pack · dischargedDOOR R1 EMERGENCY LIGHTING BATTERY PACK M33094 CAPACITY LOW DURI NG FUNCTIONAL TEST REF HAECO NON-ROUTINE NO.9446470,SPEC NO.B777 -33-3-7015. PERFORMED BY EMP V905359,REPLACED DOOR R1 M33094 BATTERY PACK AN D PERFORMED LIGHT TEST,THE RESULT WAS NORMAL REF AMM SDR CALA2021080401247Battery Pack · dischargedDOOR L3 EMERGENCY LIGHTING BATTERY PACK M33405 DOESN''T OPERATE D URING FUNCTIONAL TEST REF HAECO NON-ROUTINE NO.9446468,ORIGINATE D BY EMP V905359,SPEC NO.B777-33-3-7015. PERFORMED BY EMP V905359,REPLACED DOOR L3 BATTERY PACK M33405 AN D PERFORMED LIGHT TEST,SDR CALA2021080401246Charger · no testDOOR L3 EMERGENCY LIGHTING BATTERY PACK M33405 DOESN''T OPERATE DURING FUNCTIONAL TEST REF HAECO NON-ROUTINE NO.9450069,ORIGINAT ED BY EMP V905359,SPEC NO.B777-33-3-7015. PERFORMED BY EMP V905359,REPLACED DOOR L3 M33405 BATTERY CHARGER AND CARRIED OUT LIGHT TESDR CALA2019051700781Battery · inoperativeTEST FOUND RT DOOR 3 EMER BATTERY DM33401 INOP REF NON-ROUTINE NO.9481334 - EA 2500-04866D OP021. REPLACED RT DOOR 3 EMERGENCY LT BATTERY, C/OUT INSTALLATION TEST OF THE NEW BATTERY, THE RESULT FOUND ''NORMAL'' REF AMM 33-51-06- 960-802 REV.86.SDR CALA2019051700780Battery · dischargedTEST FOUND EMERGENCY LIGHT M33097 CAPACITY LOW REF NON-ROUTINE NO.9479212 - EA 2500-04866D OP021. REPLACED EMERGENCY LT BATTERY M33097, C/OUT INSTALLATION TEST OF THE NEW BATTERY, THE RESULT FOUND ''NORMAL'' REF AMM 33-51-06-960- 802 REV.86.SDR CALA2018020200430Latch · unlatchedR4 DOOR SLIDE PACK COVER UNLATCHED ON ONE SIDE. SECURED THE LATCH.SDR CALA2018020200397Engine · malfunctionedON ARRIVAL, RAMP REPORTED SEEING FLAMES AND SMOKE FROM THE LEFT ENGINE ON SHUTDOWN . THE ENGINE FUEL VALVE LT STATUS MESSAGE, FIM PROCEDURE CARRIED OUT IAW 73-22-00-810-801-N00, THE LEFT ENGINE WIRING CHECKED IAW WDM 76-21-71, CHECKED NORMAL. RELAY K76104, RSDR CALA2018011900216Power Supply · dischargedL4 DOOR EMERGENCY LIGHT POWER SUPPLY M33407, FOUND CAPACITY LOW THE POWER PACK WAS REPLACED, TESTED NORMAL IAW AMM 33-51-06.SDR CALA2018011200131Bulkhead Web · crackedHORI ZONTAL PRESSURE BULKHEAD WEB BS 1287 BETWEEN RBL18.3 & 25.7. FOUND CRACKED. AREA TRIMMED OUT IAW DWG 524W0008, SHT 8, HFEC IN SPECTION CARRIED OUT IAW NTM PT6 51-00-01, PROC 2, REV 71. NO CRACK WAS FOUND AT TRIMMED AREA, PLUG INSTALLED IAW DWG 624W000SDR CALA2018011200130Bulkhead · crackedHORIZONTAL BULHEAD WEB BS 1287 BETWEEN LBL 18.3, AND 25.7 FOUND CRACKED, THE BULKHEAD WEB FOUND CRACKED. TRIMMED OUT AREA IAW DRAWING 624W0008, SHT 8. HFEC INSPECTION CARRIED OUT IAW NTM PART 6, 51-00-01 PROC 2, REV 71, REV, NO CRACK WAS FOUND AT TRIMMESDR CALA2018011200129Frame · crackedRIGHT BS 2370 PIVOT BULKHEAD FORWORD FRAME FOUND CRACKED, ACCOMPLISHED OP 14 OF EA 5380-01113.SDR CALA2018011200127Bulkhead Web · crackedPRESSURE BULKHEAD WEB BS 1287 BETWEEN RBL 11 TO 18.3 FOUND CRACKED. PRESSURE BULKHEAD WEB TRIMMED OFF AND FABRICATED A FILLER IAW ECRA 5310-07340, REV-. HFEC INSPECTION CARRIED OUT IAW NTM INSPECTION CARRIED OUT IAW NTM PART 6,51-00-01 PROC 2 REV 7 REV, NO SDR CALA2018011200126Frame · crackedLEFT BS 2370 PIVOT BULKHEAD FORWARD FRAME FOUND CRACKED, INSPECTED IAW EA 5380-01113, OP 13.SDR CALA2018011200116Battery Pack · dischargedL1 DOOR EMERGENCY LIGHT BATTERY PACK M33093, FOUND CAPACITY LOW. REPLACED THE BATTERY PACK. TEST CARRIED OUT AND OPS NORMAL IAW AMM 33-51-06.SDR CALA2018011200115Battery Pack · dischargedR4 DOOR EMERGENCY LIGHT POWER PACK M33408 FOUND CAPACITY LOW. THE BATTERY PACK WAS REPLACED. TEST CARRIED OUT, AND OPS NORMAL IAW AMM 33-51-06.SDR CALA2018010500024Skin · dentedBULK CARGO DOOR DENTED. HF EC ACCOMPLISHED AND FOUND TO BE SMOOTH AND CRACK FREE, WITHIN LIMITS IAW 52-30-01 P112.SDR CALA2017092503325Cover · detachedSLIDE COVER DETACHED AT THE R4 DOOR, SLIDE COVER INSTALLED.SDR CALA2017091003117Light · damagedEMERGENCY LIGHT IS DAMAGED ON RT AISLE DIVIDER AFT OF BUSINESS CLASS. REPLACED EMERGENCY LIGHT ON RT AISLE DIVIDER AFT OF BUSINESS CLASS. OPS CHECK NORMAL.SDR CALA2017042101091Cover · missingEMERGENCY EXIT LIGHTS DAMAGED 121-22B DR-2L FWD LAV 121 2L EXIT LIGHT COVER MISSING. REPLACED EXIT INDICATOR ASSY.
Back to N784UA