N784UA
Service difficulty reports · 181
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N784UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N784UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2016061395445Battery · dischargedDOOR 1R EPAS LIGHTS NOT FLASHING. REPLACED 2 EACH, 9 VOLT BATTERY IAW 51-11-20. LIGHTS OPS CK GOOD.SDR CALA2016020395073Receptacle · burnedLAVATORY 3L BURNING SMELL. ACCOMPLISHED INSPECTIONS IAW MM 05-51-50. FOUND MIRROR LIGHT FWD LAMP RECEPTACLE BURNT & CAUSING ODOR. REMOVED LAMP, DISCONNECTED & SAFETIED BALLAST M004 CONNECTOR IAW STANDARD PRACTICES. COMPLIED WITH MEL.SDR CALA2015030993406Skin · damagedFUSE BELLY SKIN PITTING DAMAGE FROM BS 332 TO 655, STRINGER 45L TO 45R. REPAIRED IAW ECRA 5330-05042. NO PITTING DAMAGE ON THE EXISTING DOUBLER ON BS 508,BETWEEN STRINGER 47R & 48R. THIS REPAIR HAS RECEIVED STAGE 1 APPROVAL VIA FORM 8100-9 DATED FEB 13TH 20SDR CALA2015030493204Skin · damagedFUSE BELLY SKIN PITTING DAMAGE FROM BS 332 TO 655, STRINGER 45L TO 45R. REPAIRED IAW ECRA 5330-05042. NO PITTING DAMAGE ON THE EXISTING DOUBLER ON BS 508, BETWEEN STRINGER 47R & 48R. THIS REPAIR HAS RECEIVED STAGE 1 APPROVAL VIA FORM 8100-9 DATED FEB 13TH 2SDR CALA2014102492561Unknown · odorAFT GALLEY HAS A SLIGHT SMOKEY ODOR. CLEANED ALL WARMING OVENS, COFFEEMAKERS, OVENS & COFFEE WARMERS. RAN ALL ABOVE PLUS CHILLERS. NO SMOKE NOTED OR CIRCUIT BREAKERS TRIPPED. PROCEDURES AMM 05-51-11 & 05-51-50.SDR CALA2014062791338Autopilot Sys · malfunctionedALL AUTO PILOTS DISCONNECTED & NO LAND 3 STATUS MSG. CMC FAULT DOWNLINKED AUTOPILOT BACKDRIVE RT. BACKDRIVE SYS INOPERATIVE OR DEGRADED DUE TO FAILURE IN RT COLUMN. CREW CYCLED CB AS NO AUTOPILOTS WOULD ENGAGE. THE CYCLING OF THE BREAKER ALLOWED THE AUTOPISDR CALA2014030390502Unknown · malfunctionedENG EEC C1 RT ENG CONTROL IS IN A TIME LIMITED DISPATCH CONDITION. ENG CONTROL SYS IS OPERATING WITH REDUCED REDUNDANCY. STATUS MSG 01- NOT ACTIVE CRUISE MODE DEPENDENT. EEC RT ENG T2 SIGNAL DOES NOT AGREE WITH TOTAL AIR TEMPERATURE SIGNALS FROM AIR DATA INSDR CALA2013121993795Fseu · failedSLAT PRIMARY FAIL EICAS ADVISORY MESSAGE, CYCLED FLAPS & MESSAGE RETURNED. SLATS RETRACTED IN THE SECONDARY MODE. REPLACED NR 2 FSEU IAW AMM, OPERATIONS CHECKED NORMAL. NO FAULTS OR EICAS MESSAGES.SDR CALA2013120293358Pump · arcedCTR LT OVRD JETTISON PUMP PIN C FOUND ARCING. CTR LT OVRD JETTISON PUMP REPLACED IAW B777 AMM 28-22-06 & CONNECTOR DM28103 REPLACED IAW SWPM 20-61-19 & WDM 28-22-13.SDR CALA2013111392891Charger · faultyEMERGENCY EXIT LIGHTS COME ON, BUT DO NOT STAY ON FOR ONE MINUTE. LOCATED AT LT & RT SIDES OF SEAT ROWS 19 THRU 30, & AT THE RT CEILING FROM ROWS 22 THRU 30. REPLACED BATTERY CHARGER.SDR CALA2013111392890Light · inoperativeONE EMERGENCY EXIT LIGHT NOT WORKING AT RT AISLE ON WALL SIDE OF THE FWD A4 AFT GALLEY AREA ACROSS THE AISLE FROM PASSENGER DOOR 4RT. RELAMPED, OPERATION CHECKED NORMAL.SDR CALA2013100891863Battery · faultyFUEL SHUTOFF VALVE BATTERY STATUS MSG. DEF IAW MEL. ACCOMPLISHED FIM 28-22 TASK 842, REPLACED ENG FUEL SPAR VALVE BATTERY IAW MM. OPERATIONS TESTED IAW MM, OPERATIONS NORMAL.SDR CALA2013092691491Position Sensor · faultySTATUS MESSAGE "FLAP-SLAT CONTROL 2" DISPLAYED. MAT MAINTENANCE MESSAGE 27-21172, SLAT POS SENSOR 2L, FAULTED. FOUND OPEN CKT ACROSS PINS J4 & K4 AT CONN DM27002AC. SUSPECT SENSOR M27203. ACP WIRE CONTINUITY CHECK BETWEEN FSEU 2 BENCH CONNECTOR DM27002 & SLSDR CALA2013082690738Coupler · faultyFLIGHT CONTROL SYSTEM ANY CONDITION OF THE FLIGHT CONTROL SYSTEM OR IT'S SYSTEM INTERFACES WHICH WOULD PREVENT DISPATCH. FLIGHT CONTROLS SYSTEM BELOW MINIMUM DISPATCH REQUIREMENTS. STATUS MSG01- ACTIVE CRUISE HARD;POWER SUPPLY ASSEMBLY (LEFT) HAS NO OUTPUT OSDR UALA2013071204891Valve · faultyAPU BLEED STATUS MESSAGE. REPLACED SURGE VALVE IAW MM 49-53-01. OPS CHECKED OK, NO LATCH MESSAGES. NO LEAKS.SDR UALA2013070104557Generator · inoperativeRIGHT BACKUP GENERATOR INOPERATIVE.SDR UALA2013061304051Skin · dentedR4 DOOR OUTER SKIN HAS A DENT LOCATED 25 INCHES UP FROM BOTTOM, 3 INCHES FROM AFT EDGE AND APPROX 8 INCHES LONG.SDR UALA2013052803700Control Panel · failedMODE CONTROL PANEL LANE 1 OF THE 2 LANES IN AUTOPILOT FLIGHT DIRECTOR SYS (AFDS) MODE CONTROL PANEL (MCP) OR ITS INTERFACE TO THE AFDC HAS FAILED. REPLACED MCP IAW MM, OPS TESTED OK.SDR UALA2013050903250Actuator · leakingNR 2 ENGINE STATOR VANE ACTUATOR LEAKING FUEL. REPLACED SVA PER AMM, OPS AND LEAK CHECK NORMAL.SDR UALA2013050303120Fseu · failedPRIMARY FLAPS FAILED. FAULT CODE 27-20371, REF 27-51 TASK 801. REPLACED NR 1 FSEU PER MM 27-51-01. PERFORMED TRAILING EDGE FLAP SYSTEM OPS TESTED AND RAN FLAPS TO FULL. MESSAGE DID NOT RETURN.SDR UALA2013041902704Fseu · faultedFLAP SLAT CONTROL 1 HIGH LIFT CONTROL LANE NR 1 HAS A FAULT. REPLACED FSEU 1. SYSTEM OPS CHECK NORMAL.SDR UALA2013041502571Warning System · activatedSTATUS MSG "ENGINE REVERSER R" DISPLAYED. STATUS MSG CAME BACK AGAIN AFTER R-ENG REVERSER OPS. RIGHT ENGINE REVERSER DEACTIVATED PER MEL.SDR UALA2013041502581Bolt · missingOXYGEN MASKS HAVE DROPPED AT SEATS 9CD. ARMING PINS ARE STILL INSTALLED ON O2 GENERATOR BOTTLES INDICATING THEY HAVE NOT BLOWN. FOUND LEFT CENTER STOW BIN FWD AND AFT PIVOT BOLTS MISSING CAUSING STOW BIN TO CATCH ON O2 DOOR. FORCING DOOR OPEN. REPLACED PIVSDR UALA2013041202500Bulb · looseR1 DOOR EXTERNAL EMERGENCY LIGHT INOPERATIVE. . BULB LOOSE IN SOCKET.SDR UALA2013041002435Lens · brokenR1 DOOR EMERGENCY EXIT FLOOR LIGHT LENS IS BROKEN. REPLACED LENS.SDR UALA2013041002431Housing · damagedAFT GALLEY CROSS AISLE LEFT EMERGENCY LIGHT INOPERATIVE ON FWD COUNTER UNIT AT FLOOR LEVEL. FOUND LEFT ASSY BROKEN. REPLACED LIGHT ASSY WITH NEW STYLE. CHECKED GOOD.SDR UALA2013041002430Battery Pack · inoperativeLEFT CEILING EMERGENCY LIGHTS FROM DOOR 3L TO ROW 36 ARE INOPERATIVE AND AFT EXIT SIGN ON DOOR 3L IS INOPERATIVE. REPLACED BATTERY PACK AT DOOR 3L, AFT POSITION.SDR UALA2013041002429Battery Pack · inoperativeEMERGENCY LIGHTS INOPERATIVE AT R1 & L3 DOORS. REPLACED BATTERY PACK. OPS CHECKED OK.SDR UALA2013022001017Ballast · failedDURING APPROACH, AN ELECTRICAL ODOR NEAR 1L AND LAV WAS DETECTED. FOUND SOURCE OF ODOR TO BE BALLAST AT CEILING LIGHT ABOVE SEAT 1A, FOUND FLUORESCENT TUBES AT 1A LOOSE AND INTERMITTENT, REMOVED TUBES FROM 1A & 2A CEILING LIGHTS, REMOVED BALLAST AT 1A DISCOSDR UALA2013010700101Wire Harness · wornGENERATOR DRIVE LIGHT OFF, FOUND WIRES CHAFED AT HARNESS CLAMPS ON WIRE BUNDLE DM24001B. REPLACED WORN WIRE HARNESS. RAN ENGINE, CHECKEDS OKAY.SDR UALA2013010700088Wire Harness · chafedGEN DRIVE LIGHT OFF, FOUND WIRES CHAFED AT HARNESS CLAMPS ON WIRE BUNDLE DM24001C. REPLACED WIRE HARNESS.SDR UALA2012122107341Rfu · malfunctionedSATCOM SYSTEM WILL STAY IN SEARCH MODE AFTER LOG OFF AND RE-LOG ON. REPLACED RFU-L M23107 REF WD 23-15-12 PG 5A SHEET 3. NEED OPS CHECK FOR SEVERAL HOURS. ACCOMPLISHED SATCOM SYSTEM OP CHECK REF AMM 23-15-00-501, OPS NORMAL.SDR UALA2012121407248Panel · faultySATVOICE LOST SATCOM VOICE SYSTEM LOGS OFF. ADVISORY CREW COMMENTS: NO SATCOM FOR ENTIRE FLT. NOW 1.5HRS OF FLT. CHRONIC+ETOPS RESTICTED. CENTER VHF TUNING PANEL WAS REPLACED. ACCOMPLISHED GND TEST PER MM, OPS CHECK OKAY.SDR UALA2012110506333Battery · dischargedSAT PHONE INOPERATIVE IN CABIN. ON START UP FAULT BALL DISPLAYED ON CTU. TEST EQUIPMENT CHECKED OUT TO RESET CTU AND TROUBLESHOT BUT LAPTOP BATTERY DEAD.SDR UALA2012101505882Clamp · leakingRIGHT PACK UPPER FLOW CONTROL VALVE LEAKING AT V-BAND CLAMP. REPLACED V-BAND CLAMP, NO LEAKAGE NOTED.SDR UALA2012100405638Unknown · odorSMELL EMANATING FROM LEFT PACK SMELL IS IN THE REAR OF THE AC AND COCKPIT. NO SMELL IN MID AND FIRST CLASS. IT IS 1HOUR AND 52 MIN SINCE T/O. THE SMELL IS COMING FROM THE LEFT PACK, WITH LEFT PACK OFF SMELL DISSIPATED. ITEM ROLLED FORWARD. POWER AT IDLE, SDR UALA2012100305622Generator · faultySTATUS MESSAGE ELEC BACKUP GENERATOR L AFTER SHUTDOWN. CYCLED BACKUP GENERATOR SWITCH, RAN ENGINE, BUG OPERATED NORMALLY MSG RETURNED AFTER SHUTDOWN. REPLACED LEFT ENGINE BACK UP GENERATOR.SDR UALA2012100305621Start Valve · faultyAPU AIR START VALVE CYCLES OFF AND ON WITH THE APU RUNNING AND APU BLEED VALVE OFF. THIS SHOWS ON THE AIR PAGE. REPLACED STARTER VALVE REF NEEDS OPS AND LEAK CHECKS. ACP OPS CHECK, NO LEAKS NOTED.SDR UALA2012092705456Bellows · tornODOR IN THE CABIN-FD. DUE TO HISTORY OF ODOR IN THE CABIN-FD. REPLACED TORN BELLOW ON FLEXIBLE SURGE DUCT. REF AMM FOR VALVE REMOVED AND REPLACED. REMOVED APU SOV & INSPECTED UPSTREAM & DOWNSTREAM OF VALVE. NO OIL CONTAMINATION NOTED, DUCT CLEAN. RE-INSTSDR UALA2012092005340Unknown · odorACRID SMELL IN COCKPIT GOING THRU 14000 DESCENT. ON ARRIVAL NO SMELL IN CABIN , NOR COCKPIT. NO MSG FOUND. ACPD FAULT ISOLATION PROCEDURE PER FIM 21-00 TASKS 808 FOUND ALL NORMAL. NO EVIDENCE OF BIRD STRIKE ON BOTH ENGINE. RUN APU AND PACKS FOR ONE HOUR NSDR UALA2012091005083A/C Pack · contaminatedFLIGHT CABIN CREW REPORTS ACRID SMOKEY SMELL IN THE FIRST CLASS GALLEY AREA FOR 5 MINS. FOUND STRONG SMELL COMING FROM FIRST CLASS OVEN R11. REPLACED OVEN. ON APPROACH INTO IAD, PURSER REPORTED STRONG ACRID SMELL IN FIRST CLASS AREA, F. FA OPENED OVERHEAD SDR UALA2012091005079Control Valve · faultyELECTRICAL ODOR IN GALLEY, FLIGHT DIVERTED. PILOT BUNK ROOM. TURNED OFF GALLEY POWER. ODOR WENT AWAY IN GALLEY AND BUNK AREA, THEN ADDITIONAL ODOR THROUGHOUT COCKPIT AND CABIN. RAN BLEED AIR, BOTH PACKS AND RECIRC FANS WITH NO ODOR. TURNED ON ALL GALLEY ESDR UALA2012040502112Module · faultyUNABLE TO CONTROL ZONE CABIN LIGHTING. SWAPPED ZMU NR 1 WITH ZMU NR 3 PER AMM, OK.SDR UALA2012032201824Oven · dirtyBURNING ODOR 2R, NO SMOKE. FOUND PLASTIC BUGS BURNT IN WARMING OVEN W31 CAUSED BURNING ODOR IN THE DOOR 2 AREA. REMOVED BUGS FROM OVEN. NEED TO CLEAN DEBRIS IN THE OVEN OR REPLACE ITSELF. CONSULTED WITH TOMC AND DEACTIVATED W31 OVEN PER MEL PROC. CREW ALSSDR UALA2012032301868Oven · dirtyBURNING ODOR 2R. NO SMOKE. ITEM ROLLED FORWARD. FOUND PLASTIC BUGS BURNT IN WARMING OVEN W31 CAUSED BURNING ODOR IN THE DOOR 2 AREA. REMOVED BUGS FROM OVEN. NEED TO CLEAN DEBRIS IN THE OVEN OR REPLACE ITSELF. CONSULTED WITH TOMC AND DE-ACTIVATED W31 OVENSDR UALA2012030801527Floor Panel · damagedFLOORBOARD IN FRONT OF LAV 131 IS SPONGY. REPLACED FLOOR PANEL REF SFOOV WRITE UP B3260X.SDR UALA2012022801213Toilet · odorDOOR 3 LAV ODOR. REPEAT FOUL STENCH FROM AREA OF DR 3 LAVS. FLT 804-27 REPORTS CROSS AISLE FLOOR BETWEEN LAVS AT DOOR 3 IS WET. NEED TO REMOVE TOILET SHROUDS IN LAVS 131 AND 133. CLEAN AREA, INSPECT WASTE LINES BENEATH TOILET ASSEMBLIES INCLUDING RMVL OF SDR UALA2012022301102Pseu · faultySTATUS R GEAR DOOR SENSOR. NOSE GEAR UP SENSOR+NOSE GEAR DOOR SENSOR. CMC MSG 1 TO 9 ARE SAME REASON. REPLACED PSEU PER MM. GROUND TEST PASS ALL MSG WAS DISAPPEAR. ALL TEST WITH HYD PRESSURE. NO HYD LEAK FOUND.SDR UALA2012021500928Heat Shield · wornFOUND NR 1 HEAT SHIELD GAP COVER WORN INTO HEAT SHIELD I/B EDGE AND NR 2 GAP COVER O/B EDGE WORN INTO HEAT SHIELD. REPLACED HEAT SHIELD ASSY.SDR UALA2012021000810Module · faultyON TAKEOFF GEAR HANDLE WOULDN'T RAISE FOR SEVERAL SECONDS.RAISED ON 3RD REPLACED ALT BRAKE PRESS TRANSDUCER M32225 PER FIM AND REPLACED LANDING GEAR HANDLE MODULE. ALL OPS CHECKS OKAY.
Back to N784UA