N801SY
Service difficulty reports · 218
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N801SY' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N801SY' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SCNA20201008130Floorbeam · corrodedFLOOR BEAM AT BS 986.5 HAS CORROSION FROM LBL 43 TO RBL 47.5. ACCOMPLISHED FLOOR BEAM REPAIR STA 986.5 RBL 50-LBL 50, IAW ATS ER 20-03204 REV IR DATED 09/24/2020 AND SUN COUNTRY EA 53-0053 REV 00.SDR SCNA20201008129Mount · corrodedAFT GALLEY LT AND RT MOUNTS ARE CORRODED. INSTALLED NEW AFT GALLEY LT AND RT MOUNTS.SDR SCNA20201008128Floor Support · corrodedFLOOR STRUCTURE AT BS 947 + 11" RBL 25 HAS CORROSION AROUND HOLE. REMOVED FLOOR SUPPOT STRUCTURE AT BS 947+11 DUE TO BE OUT OF LIMITS, PER SRM 53-70-51-1A-1 FIG 104. LOCATED, DRILLED, AND INSTALLED NEW INTERCOSTAL ITEM NR 147A5660U3 PER DWG 47A5650 AND SRM 5SDR SCNA20201008127Channel · corrodedRT MOP SILL HAS CORROSION FROM BS 947.5 TO BS 986.5 RBL 56. CORROSION ON RT MOP SILL BS 947.5 TO 986.5 FOUND TO BE OUT OF LIMITS, IAW SRM 53-70-15-1A-1 FIG 103 DETAIL E. REMOVED AND REPLACED MOP SILL PO 801719, IAW SRM 51-40-02-0G-0 BOEING DWG 147A8501 REV BSDR SCNA20201008126Strap · corrodedAFT GALLEY FLOOR STRAP AT BS 1016 + 11" TO BS 1016 + 13", RBL 3 HAS CORROSION. REMOVED AND REPLACED AFT GALLEY FLOOR STRAP AT BS 1016+11-1016+13 RBL 3 WITH NEW REPLACEMENT PART PO NR 801412, IAW SRM 51-40-02 AND BOEING DWG 147A5700 57111U.SDR SCNA20201008125Channel · corrodedFORWARD CARGO BAY LEFT HAND Z CHANNEL MULTIPLE SPOTS OF CORROSION NEAR SCREW HOLES STA 500C-500I, MARKED. REMOVED FWD CARGO LT Z-CHANNEL FS 500B+10-500I DUE TO OUT OF LIMITS CORROSION, IAW SRM 51-40-02-0G-0 AND 53-00-53-1A-2. FABRICATED REPLACEMENT Z-CHANNESDR SCNA20201008124Frame · gougedGOUGE FOUND ON STA 986.5 FRAME AT RBL 46 WL 209. FOUND GOUGE TO BE OUT OF LIMITS, PER SRM 53-00-07-1A-1 4(A)1. REPLACED DAMAGED FRAME SECTION BS 986.5 JUST BELOW STRINGER 17 TO STRINGER 24 RH, PER SRM 51-40-02 AND DRAWING 147A1086 SHEET 29 AND DRAWING 147A00SDR SCNA20201008123Pan · corrodedAFT GALLEY FLOOR PAN AT BS 986.5 + 2", RBL 43.5 HAS CORROSION. CORROSION ON AFT GALLEY FLOOR PAN (SHEAR WEB) AT STA 986.5+2, RBL 43.5 IN AN AREA OF 1.5" X 1.0" FOUND TO BE OUT OF LIMITS, DUE TO NO SRM ALLOWABLE LIMITS FOUND. REMOVED AND REPLACED SHEAR WEB STSDR SCNA20201008122Channel · corrodedFORWARD CARGO BAY CORROSION ON INTERCOSTAL UNDER LEFT CARGO FLOOR Z CHANNEL STA 500F-500G LBL 25 WL 160 NEAR SCREW HOLES, MARKED. CORROSION ON FWD CARGO BAY INTERCOSTAL UNDER LEFT CARGO FLOOR Z-CHANNEL STA 500E TO 500G LBL 25 WL 160 FOUND TO BE OUT OF LIMITS,SDR SCNA20201008121Rib · crackedLT HORIZONTAL STABILIZER RIB AT STAB STA 92.7 HAS A CRACKED ON 2ND STIFFENER AT THE BOTTOM. REPAIRED LT HORIZ STAB AT STA 92.7 2ND STIFFENER, IAW SRM 55-10-09-2R-4.SDR SCNA20201008120Floor Support · corrodedFLOOR STRUCTURE AT BS 947.5+11" LBL 25 HAS CORROSION AROUND HOLES. REMOVED AND REPLACED FLOOR SUPPORT 947-967 LBL 25, DUE TO OUT OF LIMITS. CORROSION BLEND AREA 1" L X 1" W X .017" D, IAW SRM 53-70-51-1A-1, SRM 51-40-02-0G-0 AND DWG 147A5650 AND SRM 51-40-0SDR SCNA20201008119Rib · crackedRT HORIZONTAL STABILIZER RIB AT STAB STA 92.7, 2ND STIFFENER ARE CRACKED AT THE BOTTOM. REPAIRED RT HORIZ STAB RIB AT STAB STA 92.7, 2ND STIFFENER, IAW SRM 55-10-09-2R-4.SDR SCNA20201008118Mount · corrodedFORWARD CARGO BAY AFT LOWER WALL MOUNT STA 500I HAS MULTIPLE AREAS OF CORROSION BETWEEN STR 24L-24R, MARKED. REMOVED AND REPLACED FORWARD CARGO BAY AFT LOWER WALL MOUNT STA 500I, IAW SRM 51-40-02 AND DWGS 143A7902 AND 143A9481.SDR SCNA20201008117Cargo Track · corrodedFORWARD CARGO BAY LEFT HAND AFT CARGO WEBBING MOUNT 3" FORWARD OF STA 500I HAS CORROSION AROUND FLOOR BOLTS, MARKED. REMOVED AND INSTALLED NEW FORWARD CARGO BAY LEFT HAND AFT CARGO TRACK AT STA 500G+12-500I, IAW SRM 53-00-53-2R-3 AND DWG 143A7500.SDR SCNA20201008116Floor Splice · corrodedFORWARD CARGO BAY CORROSION ON INTERCOSTAL UNDER LEFT CARGO FLOOR Z CHANNEL STA 500G-500H LBL 25 WL 160 NEAR SCREW HOLES, MARKED. FORWARD CARGO BAY INTERCOSTAL FROM BS 500G TO 500H LBL 25 FOUND TO BE OUT OF LIMITS, IAW B737-800 SRM 53-00-53-1A-2 FIG 103. REMSDR SCNA20201008115Floor Support · corrodedFORWARD CARGO BAY CORROSION ON INTERCOSTAL UNDER LEFT CARGO FLOOR Z CHANNEL STA 500E-500F LBL 25 WL 160 NEAR SCREW HOLES, MARKED. FORWARD CARGO BAY INTERCOSTAL FROM BS 500E TO 500F LBL 25 UNDER Z CHANNEL FOUND TO BE OUT OF LIMITS, IAW B737-800 SRM NO ALLOWABLSDR SCNA20201008114Floor Support · corrodedCORROSION FORWARD CARBO BAY CORROSION ON INTERCOSTAL UNDER LEFT CARGO FLOOR Z CHANNEL STA 500D-500E LBL 25 WL 160 NEAR SCREW HOLES, MARKED. FORWARD CARGO BAY INTERCOSTAL AT BS 500D TO 500E LBL 25 UNDER Z-CHANNEL FOUND TO BE OUT OF LIMITS, IAW B737-800 SRM 53SDR SCNA20201008113Fitting · corrodedCORROSION FOUND AT STA 1016, STR 24R TERMINAL FITTING. CORROSION ON STR 24R TERMINAL FITTING BS 1016 FOUND TO BE OUT OF LIMITS, DUE TO NO SRM ALLOWABLE DAMAGE LIMITS FOR THIS PART. REMOVED TERMINAL FITTING. LOCATED, DRILLED AND INSTALLED NEW FITTING, PER SRSDR SCNA20201008112Channel · corrodedFORWARD CARGO BAY RIGHT HAND Z CHANNEL HAS MULTIPLE AREAS OF CORROSION STA 500C-500I, MARKED. FORWARD CARGO BAY RIGHT HAND Z-CHANNEL BS 500C TO BS 500I FOUND TO BE OUT LIMITS, IAW B737-800 SRM 53-00-53-1A-2 FIG 103 DETAIL D. REMOVED AND REPLACED Z CHANNEL, SDR SCNA20201008111Support · corrodedCORROSION FOUND ON AFT GALLEY WALL SUPPORT AT STA 1015 RBL 31 WL 208. REMOVED AND REPLACED DAMAGED AFT GALLEY WALL SUPPORT STA 991-1015 RBL 31 WL 208, IAW SRM 51-40-02-0G-0 AND BOEING DWG 147A5700.SDR SCNA20201008110Support · corrodedCORROSION ON GALLEY WALL SUPPORT WL 208 BS 993 RBL 34-RBL 47. CORROSION ON AFT GALLEY WALL SUPPORT STA 992 RBL 33-45 WL 208 FOUND TO BE OUT OF LIMITS, DUE TO NO SRM ALLOWABLE LIMITS FOUND. REPLACED PART NR 147A5710U2.SDR SCNA20201008109Floor Support · corrodedAFT GALLEY FLOOR STRUCTURE AT BS 1006 +8, LBL 31.5 HAS CORROSION. REMOVED AND REPLACED AFT GALLEY WALL SUPPORT FLOOR STRUCTURE STA 991-1015 LBL 31 WL 208, IAW SRM 51-40-02-0G-0 AND BOEING DWG 147A5700.SDR SCNA20201008108Vertical Support · crackedVERTICAL STIFFENER CRACKED AT BS 663 LBL 25 WL 150. REMOVED AND REPLACED VERTICAL STIFFENER AT BS 663 LBL 25 WL 150 WITH PO 802748, IAW SRM 51-40-02-0G-0 AND BOEING DWG 111A1000 REV B 57828U.SDR SCNA20201008107Stiffener · crackedRT HORIZONTAL STABILIZER RIB AT STAB STA 92.7, 3RD STIFFENER CRACKED. REPAIRED RT HORIZ STAB AT STAB STA 92.7, 3RD STIFFENER, IAW SRM 55-10-09-2R-4.SDR SCNA20201008106Web · corrodedLOWER MAIN SILL WEB STA 947 TO 992 WL 208 RT HAS MULTIPLE AREAS OF CORROSION. LOWER MAIN SILL WEB STA 947 TO 992 WL 208 RT FOUND TO BE OUT OF LIMITS, IAW SRM 53-70-15-1A-1 FIG 103 DETAIL (D). REMOVED SILL WEB, IAW SRM 51-40-02-0G-0. INSTALLED NEW WEB P/O 80SDR SCNA20201008105Channel · corrodedRT FWD SERVICE DOOR MOP SILL CORRODED BS 312 + 7.5" TO 328 + 5 " RBL 58. RT FWD SERVICE DOOR MOP SILL CORRODED BS 312 + 7.5" TO 328 + 5 " RBL 58.SDR SCNA20201008104Channel · corrodedLT AFT ENTRY DOOR MOP SILL CORRODED FROM BS 947.5 TO BS 986.5 LBL 56. CORROSION FOUND ON LT AFT ENTRY DOOR MOPSILL STA 947-986 LBL 56 FOUND TO BE OUT OF LIMITS, IAW SRM 53-70-15-1A-1 FIG 103 DET D. REMOVED AND REPLACED WITH NEW PART PO 801720, IAW SRM 51-40-SDR SCNA20201008103Attach Bracket · corrodedCORROSION FOUND ON BRACKET ATTACHED TO INTERNAL SURFACE OF FUSELAGE SKIN AT AFT SIDE OF OUTFLOW VALVE STA 981 BETWEEN S24R AND S25R. REMOVED AND REPLACED OUTFLOW VALVE MOUNT BRACKET STA 981 AFT INBOARD SIDE, IAW SRM 51-40-02 AND DWG 147A0002 REV.SDR SCNA20201008102Intercostal · corrodedFORWARD CARGO BAY CORROSION ON INTERCOSTAL UNDER LEFT CARGO FLOOR Z CHANNEL STA 500C-500D LBL 25 WL 160 NEAR SCREW HOLES, MARKED. REMOVED DAMAGED FWD CARGO BAY INTERCOSTAL UNDER LEFT CARGO FLOOR Z CHANNEL BS 500C-500D LBL25. LOCATED, DRILLED, AND INSTALLED NSDR SCNA20201008101Channel · corrodedFWD ENTRY DOOR MOP SILL CORRODED BS 312 + 5" TO BS 344 LBL 58. NDED CORROSION ON FWD ENTRY CHORD (MOPSILL) BS 312+5 TO 344 LBL 58 WL 208, FOUND OUT OF LIMITS DUE TO CROSSING OVER FASTENER HOLES, PER SRM 53-10-15-1A-2 (DETAIL D&G). REMOVED AND REPLACED INNER SDR SCNA20201008100Intercostal · corrodedFORWARD CARGO BAY INTERCOSTAL UNDER RIGHT HAND Z CHANNEL STA 500B+2 CRACKED AT SCREW HOLE, MARKED. REMOVED AND REPLACED FWD CARGO BAY INTERCOSTAL STA 500B TO 500C RBL 25 PO 802809, IAW SRM 51-40-02-0G-0 AND BOEING DWG 143A7505 REV B 57828U.SDR SCNA20201008099Intercostal · corrodedFORWARD CARGO BAY CORROSION ON INTERCOSTAL UNDER LEFT HAND CARGO FLOOR Z CHANNEL STA 500H-500I NEAR SCREW HOLES, MARKED. FOUND CORROSION ON FWD CARGO BAY INTERCOSTAL UNDER LT CARGO FLOOR Z CHANNEL BS 500H-500I TO BE OUT OF LIMITS, IAW SRM 53-00-53-1A-2 PARA 4SDR SCNA20201007098Support · chafedWING TO BODY SUPPORT HAS CHAFE DAMAGE BS 651-673 LBL 25 WL 150. WING TO BODY SUPPORT BS 651-673 LBL 25 WL 150 FOUND TO BE OUT OF LIMITS, IAW SRM 53-40-71-1A-1 FIG 103 DETAIL (C). REMOVED SUPPORT IAW SRM 51-40-02-0G-0. INSTALLED NEW WING TO BODY SUPPORT, IAWSDR SCNA20201007097Tail Cone · puncturedPUNCTURE IN LT SIDE OF APU TAILCONE 22 INCHES FROM LEADING EDGE, STA 1178 APPROXIMATELY 16.5 INCHES FROM BOTTOM CENTERLINE. REPAIRED PUNCTURE IN LT SIDE OF APU TAIL CONE 22" FROM LEADING EDGE, STA 1178 AND APPROXIMATELY 16.5" FROM BOTTOM CENTER LINE, PER SRMSDR SCNA20201007096Floorbeam · corrodedFLOOR BEAM CORRODED BS 328 RBL 39 TO RBL 58. CORROSION ON FS 328 FLOOR BEAM RBL 39-58 UPPER CHORD FOUND TO OUT OF LIMITS, DUE TO EXISTING REPAIR. REMOVED AND REPLACED UPPER CHORD OF FS 328 FLOOR BEAM, IAW SRM 53-10-51 REF EA 15794.SDR SCNA20201007095Strap · corrodedAFT GALLEY FLOOR STRAP AT BS 1016 + 4" TO BS 1016 + 14.5" LBL 3 HAS CORROSION. REMOVED AFT GALLEY FLOOR STRAP AT BS 1016+4" TO 1016+14.5" LBL 3 AND FOUND TO BE OUT OF LIMITS. RECEIVED NEW GALLEY STRAP PN 147A5714YR AND LOCATED, DRILLED, AND INSTALLED NEW PASDR SCNA20201007094Attach Bracket · crackedINTERCOSTAL ATTACH BRACKET TO FRAME BS 500H RBL 25 CRACKED ON AFT SIDE OF FRAME. REMOVED AND REPLACED ATTACH BRACKET BS 500H RBL 25, IAW SRM 51-40-02-0G-0 DRG 143A7505 PO 801210 57309U.SDR SCNA20201007093Baffle · crackedFWD CARGO, RT ZEE CHANNEL BAFFLE CRACKED WHERE IT ATTACHES TO CLIP, INBOARD SIDE, STA 500A+1 RBL 24. REMOVED CRACKED BAFFLE AT BS 500A TO 500B RBL 24. FOUND TO BE OUT OF LIMITS, IAW SRM 51-10-02-0G-0. INSTALLED REPLACEMENT BAFFLE PO 802809 FROM BS 500A TO 5SDR SCNA20201007092Channel · corrodedCORROSION FORWARD CARBO BAY CORROSION ON INTERCOSTAL UNDER RIGHT HAND CARGO FLOOR Z CHANNEL STA 500H-500I NEAR SCREW HOLES, MARKED. REMOVED AND REPLACED INTERCOSTAL STA 500H-500I RBL 25 WITH REPLACEMENT PO 801182, IAW SRM 51-40-02-0G-0 DRG 143A7505 57309U.SDR SCNA20201007091Channel · corrodedCORROSION FORWARD CARGO BAY CORROSION ON INTERCOSTALS UNDER LEFT CARGO FLOOR Z CHANNEL STA 500B-500C LBL 25 WL 160 NEAR SCREW HOLES, MARKED. REMOVED FWD CARGO BAY INTERCOSTAL UNDER LEFT CARGO FLOOR 2 CHANNEL BS 500B-500C LBL 25. LOCATED AND DRILLED NEW INTERSDR SCNA20201007090Floor Support · crackedINTERCOSTAL CRACKED BETWEEN BS 312 AND BS 328 RBL 31. REMOVED CRACKED INTERCOSTAL BETWEEN BS 312 TO BS 328 RBL 31 FOUND TO BE OUT OF LIMITS, PER SRM 53-10-51-1A-1. INSTALLED REPLACEMENT INTERCOSTAL PO 801703, IAW SRM 51-40-02 AND BOEING DWG 141A5400 REV - IDSDR SCNA20201007089Channel · corrodedAFT CARGO BAY RIGHT HAND Z CHANNEL HAS MULTIPLE AREAS OF CORROSION STATION 727B-767, MARKED. CORROSION ON AFT CARGO BAY RT Z CHANNEL FOUND TO BE OUT OF LIMITS DUE TO PROXIMITY OF FASTENER HOLES, IAW SRM 53-00-53-1A-2 FIG 103 DETAIL D. REMOVED Z CHANNEL, IAW SDR SCNA20201007088Angle · corrodedFWD CARGO, Z CHANNEL BAFFLE CLIP HAS CORROSION AT 500C 25LBL OUTBOARD OF S-26L. REMOVED FWD CARGO 2 CHANNEL BAFFLE CLIP BS 500C LBL 25 OUTBOARD OF S-26L. LOCATED, DRILLED, AND INSTALLED NEW BAFFLE CLIP, IAW SRM 51-40-02-0G-0, SRM 51-40-05-0G-0 AND DWG 143A7SDR SCNA20201007087Intercostal · corrodedCORROSION FOUND ON OUTBOARD SIDE OF INTERCOSTAL STA 991 S21L LBL 39 WL 185. REMOVED AND REPLACED DAMAGED INTERCOSTAL AT STA 991 STR 21L LOL 39 WL 185 WITH NEW PART NR 147A8801U85 IAW SRM 51-40-02-0G-0 AND DWG 147A8801.SDR SCNA20201007086Support · damagedTOOLING DAMAGE ON LAV HARD POINT SUPPORT BS 294.5 TO 312 LBL 11.16 WL 208. TOOLING DAMAGE ON LAV HARD POINT SUPPORT BS 294.5-312 LBL 11.16 WL 208 FOUND TO BE OUT OF LIMITS DUE TO NO ALLOWABLE LIMITS, PER SRM. REMOVED AND REPLACED LAV HARD POINT SUPP BS 294.5SDR SCNA20201007085Support · brokenWASTE TANK ENCLOSURE LOWER STANCHION SUPPORT BROKEN BS 867 LBL 10 WL 160. REMOVED BROKEN STANCHION SUPPORT AT BS 867 LBL 10 WL 160, IAW SRM 51-40-02-0G-0. INSTALLED NEW STANCHION P/O 802020/1, IAW SRM 51-40-02-0G-0 AND BOEING DWG 149A8102 REV C.SDR SCNA20201007084Floorbeam · damagedFOUND TOOLING DAMAGE ON SURFACE OF UPPER CHORD AT STA 312 LBL 10 TO LBL 53 WL 208. TOOLING DAMAGE FOUND ON SURFACE OF UPPER CHORD STA 312 FLOOR BEAM LBL 12 1" L X .7" W X .011" D LBL 16.5 1" L X .7" W X .013" D BOTH FOUND TO BE OUT OF LIMITS, IAW SRM 53-10-51SDR SCNA20201007083Floor Support · crackedINTERCOSTAL BETWEEN BS 312 AND BS 328 LBL 11 CRACKED. REMOVED AND REPLACED CRACKED INTERCOSTAL STA 312-328 LBL 11, IAW SRM 51-40-02-0G-0, SRM 51-40-05-0G-0 AND DWG 141A5400 SHEET 27 REV- 57901U.SDR SCNA20201007082Floor Support · damagedTOOLING MARK ON FLOOR STRUCTURE BS 277 TO BS 294.5 LBL 11. TOOLING MARK ON FLOOR STRUCTURE BS 277-294.5 LBL 11 FOUND TO BE OUT OF LIMITS, DUE TO NO ALLOWABLE LIMITS, PER SRM. REMOVED AND REPLACED INTERCOSTAL, IAW SRM 51-40-02-0G-0, SRM 51-40-05-0G-0 AND DWG SDR SCNA20201007081Floor Support · damagedTOOLING MARKS ON FLOOR STRUCTURE BS 328 TO BS 344 LBL 11. REMOVED TOOLING MARKS ON FLOOR STRUCTURE STA 328-344 LBL 11 IN AN AREA OF L 2" X W .6" X D .017", IAW SRM 51-10-02-0G-0. DAMAGE FOUND TO BE OUT OF LIMITS, IAW SRM 53-10-51-1A-1 FIGURE 105 DETAIL C. R