N802UA
Service difficulty reports · 124
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N802UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N802UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2017091803248Power Supply · failedAFT, LEFT CABIN EMERGENCY LIGHT EPSU FAILED. REPLACED THE EPSU IAW 33-51-38SDR CALA2017091803247Connector · shortedEMERGENCY LIGHT TEST FAILED, LEFT AFT POSITION WITH INTERNAL LIGHT FAILED. SEVERAL SEATS IN AFT CABIN TURN ON AND THEN OFF WHEN COMMANDED ON. ISOLATED TO SHORTED CONNECTOR 7260V6 IAW WD33-51-08. REPLACED THE CONNECTOR, OPS CHECKED NORMAL. NO DEFECTS NOTED.SDR CALA2017013000216Power Supply · faultyWHEN PERFORMING EMERGENCY LIGHT CK ON 2 SERVICE GOT FAULT EPSU UNIT EMER L MESSAGE. UNABLE TO CLEAR. REPLACED EMERGENCY POWER SUPPLY UNIT AND BATTERY AT 11WL PER 33-51-38AMM. OPS CK GOOD.SDR CALA2016083095701Warning Light · false activationRETURN TO FIELD DUE TO REAR CARGO DOOR OPEN INDICATION. UPON ARRIVAL FOUND DOOR COMPLETELY LOCKED IN CLOSED POSITION IN DETENT. AFT CARGO DOOR FUNCTIONAL CHECK, ALL CHECKS OK.SDR CALA2015100594571Charger · inoperativeEMERGENCY LIGHTS OPERATIONAL TEST FAILED IAW 2 SVC. REPLACED AFT BATTERY CHARGER & BATTERY PACK. OPERATIONS NORMAL IAW MM33-51-38.SDR CALA2013112793304Interface Unit · faultyLGCIU 2 FAULT DISPLAYED ON UPPER ECAM SCREEN LG. COMPLIED WITH MT 32-002, NO FAULT CODES FOUND. REPLACED NR 2 LGCIU IAW MM, TESTED OKAY.SDR CALA2013112093142Structure · damagedFWD GALLEY FLOOR IS AN AREA 1 FT SQ SECTION. AREA IS APPROXIMATELY 7 INCH BY 5 INCH. MADE TEMP REPAIR IAW SRM 53-02-00.SDR CALA2013112093109Coupling · misalignedFUEL CAP MISSING ON WALK AROUND. FUEL SHEET WAS ALREADY ON BOARD. REFUEL-DEFUEL COUPLING ELEMENT ASSEMBLY MISALIGNED. REALIGNED COUPLING IAW AMM. REPLACED FUEL COUPLING CAP.SDR CALA2013102392322Warning System · activatedFUEL HEAT SYSTEM DISPLAYED ON UPPER ECAM SCREEN. FUEL RETURN VLV OPEN. ENG 1 MAINT TEXT IAW TSM 73-00-00-810-809B FADEC FLIGHT DATA SHOWS FAULT CODE SPVFO IN FADEC 1A. FAULT CONFIRMATION REQUIRES HIGH POWER ASSURANCE TEST TO SEE IF THE FAULT IS PRESENT. IASDR CALA2013090991148Tire · vibrationSTRONG NOSE WHEEL VIBRATION AT 90 KTS UNTIL AFTER RETRACTION. CHECK NR 2 NOSE TIRE. R&R BOTH NOSE TIRES IAW AMM. SN OFF RT TIRE B2732P & SN OFF LT TIRE 8734P.SDR CALA2013090691078Seat · looseSEAT 28C IS LOOSE IN TRACK. SECURED LOOSE SEAT INTO PLACE, AC OKAYED FOR SERVICE.SDR CALA2013090290918Oven · fireGALLEY OVEN 105R11 TOO HOT. FIRE IN OVEN WAS PUT OUT BY FLIGHT ATTENDANT. COMPLETED FORM 46-6020 FOR SMOKE-ODOR QUESTIONNAIRE. CARDBOARD TOP FOR THE COOKIE TIN THE COOKIES CAME IN CAUGHT FIRE. REMOVED DEBRIS FROM OVEN & PLACED NR 1 OVEN IN FIRST CLASS ON MESDR CALA2013082690760Audio Panel · defectiveFIRST OFFICERS MICROPHONE HOT AT ALL TIMES. SWAPPED FIRST OFFICERS AUDIO CONTROL PANEL WITH 3RD OBSERVERS AUDIO CONTROL PANEL. REPLACED AUDIO CONTROL PANEL.SDR CALA2013082690733Seat · looseSEAT 28C LOOSE. SECURED SEAT ASSEMBLY.SDR CALA2013082690762Battery · faultyREPEAT BCL 1 FAULTS. DUE TO REPEAT BCL 1 FAULTS WITH SYSTEM BEING RESET& BITE CHECKED GOOD. REPLACED BCL 1 & 6PB1 CONTACTOR, OPERATION NORMAL.SDR UALA2013071705028Computer · malfunctionedRT OUTER TANK HI TEMP DISPLAYED ON UPPER ECAM SCREEN. FUEL LT OUTER TANK TEMP 22 RT OUTER TANK TEMP 64 BOTH NORMAL AFTER 30 SECS. RETURNED AGAIN. ACCOMPLISH CHRONIC REVIEW. R & R FUEL QTY COMPUTER AND OPS CK NORMAL ON AMM 28-42-34-400-001-A.SDR UALA2013070904793Galley Mat · unsecureFWD GALLEY FLOORING LOOSE, TRIM MISSING. PERFORMED REPAIR IAW ECRA 2533-01004.SDR UALA2013062704495Radome · damagedRADOME HAS MULTIPLE AREAS PEELING.SDR UALA2013062604469Oxygen Mask · unwanted deploy25 ABC, OXYGEN MASKS DROPPED. COMPLIED WITH MT 35-003. INSPECTED LATCH PIN HINGE. ALL GOOD. PERFORMED DROP CHECK IAW MT 35-003.SDR UALA2013022001039Converter · faultyCAPT WINDSHIELD WIPER ONLY OPERATES IN SLOW SPEED. REMOVED AND REPLACED CAPTS WIPER MOTOR CONVERTER ASSY IAW MM. OPERATED CAPTAIN'S WIPER, CHECKS GOOD.SDR UALA2013012500473Servo Valve · malfunctionedRIGHT ELEVATOR INBD SERVO VALVE FAILED OPS CHECK OF NEW UNIT. REMOVED AND REPLACED SERVO VALVE, OPS CHECKED GOOD.SDR UALA2013012400439Screw · missingSCREW MISSING AT FWD CORNER OF PANEL 424CR ON OTBD SIDE NR 2 ENGINE PYLON. REPLACED MISSING SCREW.SDR UALA2013011800324Striker · faultedCOCKPIT DOOR 'FAULT' LIGHT AND DOOR CONTROLLER 'TOP STRIKE' OR 'LOWER STRIKE' LIGHT IS ON.SDR UALA2013011600263Computer · faultyPILOT REPORTS RT BLUE ELEVATOR SERVO BOXED WITH ELEV SERVO FAULT. REPLACED SEC 1 FOR FAULT "SEC 1 OR WIRING FROM R Y ELEVATOR MODE TRANSDUCER 34CE2", OPS CHECKED GOOD.SDR UALA2012111606588Seat · defectiveF/O SEAT RECLINE DEFECTIVE. SEAT FALLS AFT RATHER THAN SPRING FWD. REPLACED 1ST OFFICER'S SEAT PER MM, OPS CHECKED NORMAL.SDR UALA2012111206504Strap · tornLEATHER TIE-DOWN STRAP ON COCKPIT CRASH AXE IS TORN. REPLACED STRAP WITH NEW ONE.SDR UALA2012101705917Battery · failedCABIN EMERGENCY LIGHT CHECK EPSU BATTERY AFT L FAILED. REPLACED BATTERY AT AFT LEFT POWER SUPPLY UNIT AND OPS CHECKED OK.SDR UALA2012101505877Drain · cloggedAFT GALLEY CARPET SOAKED. SOURCE UNKNOWN. INSPECTED FOR LEAKS AROUND NR 3 GALLEY, FOUND THE DRAIN FOR THE G3 CHILLER CLOGGED AND LEAKING IN COMPARTMENTS 301, 302, 303, THE CENTER AISLE, AND AFT RIGHT ROW OF SEATS. CLEANED CARPETS WITH WET-VAC AND MOPPED UP SDR UALA2012080904336Bottle · low pressureCOCKPIT FIRE EXTINGUISHER NOT IN THE GREEN. REPLACED BOTTLE.SDR UALA2012051102758Computer · faultyAIRCRAFT HAS NOSE-UP PITCH TENDENCY WHILE HAND FLYING. EITHER SIDESTICK. NO ECAMS. REPLACED ELAC 2 AND OPS CHECKED OK IAW MM.SDR UALA2011112906563Oxygen Mask · leakingSUSPECT CREW OXYGEN LEAK. AIRCRAFT LOSES ABOUT 600 LBS OF PRESSURE EVERY 4-6 DAYS. REPLACED F/O OXYGEN MASK PER MM. SERVICED O2.SDR UALA2011082904615Control Panel · failedEMERGENCY LIGHTS COME ON WHEN EXT POWER IS REMOVED & EMERGENCY LIGHT SWITCH IS IN THE OFF POSITION. EMERGENCY LIGHT TEST SHOWS 33-51-38 EPSU COMM FWD L, EPSU COMM EMERGENCY R, AFT L. REPLACED AFT ATTEND CONTROL PANEL AT 2L, OPS CHECKS GOOD, NO FAULTS WITH ACSDR UALA2011082904608Wire Harness · brokenFOUND SEAT 29C EMER AISLE LIGHT INOP. FOUND CONNECTION ON SEAT SIDE BROKEN OFF AND BARE WIRES HANGING UNDERNEATH SEAT 29C. REPLACED BROKEN HARNESS. LIGHT CHECKS GOOD.SDR UALA2011080304043Control Unit · faultyWHEEL BRAKES GRABBING-LEFT SIDE CREW COMMENTS: LEFT BRAKE GRABBING BETWEEN 60 AND 80 KNOTS. AFTER BSCU REPLACEMENT. BRAKES OP CHECK NORMAL.SDR UALA2011062403101Oxygen Mask · inoperativePAX O2 MASKS DOWN AT 27 ABC. SEAT ROW 27ABC PAX O2 STORAGE RENDERED INOPERATIVE PER MEL 35060. MASK'S HAVE BEEN REPACKED. RAN TEST ON SYSTEM RESET OPS CHECKED NORMAL IAW AMM.SDR UALA2011060302719Door · out of adjustCABIN - PAX SEAT ROW 2R O2 COMPT DOOR DID NOT OPEN DURING DROP TEST. FROM W-U S8125M. ADJUSTED CONTAINER DOOR. DOOR OPS GOOD.SDR UALA2011060302718Door · out of adjustCABIN - FWD LAV O2 COMPT DOOR DID NOT OPEN DURING DROP TEST. ON BASE W-U E6624G. ADJUSTED CONTAINER DOOR. DOOR OPS GOOD.SDR UALA2011040601659Fire Bottle · emptyFIRE EXTINGUISHER IN LAV IN THE RED. AFT LAV 136 WASTE BIN FIRE EXT INOP. REPLACED AFT LAV FIRE BOTTLE REF MM.SDR UALA2011032501438Hydraulic System · leakingHYDRAULIC FLUID ON UNDERSIDE OF ACFT WHEEL WELLS AFT. REPLACED BOBBIN (110-1939) ASSY ON THE GREEN HYDRAULIC SYSTEM HP MANIFOLD IAW MM & FILTER IAW MM LEAK CHECKS GOOD.SDR UALA2011032101332Computer · faultySUDDEN RUDDER MOVEMENT WITH YAW. WHILE TRYING TO CHECK RUDDER OPS USING SINGLE HYD, IT APPEARS THAT THE RUDDER IS OUT OF NEUTRAL. FOUND RUDDER NEUTRAL POSITION REFERENCE TRIANGLE TOO FAR AFT OF POINTER TO BE USED FOR RUDDER NEUTRAL POSITION VERIFICATION. RSDR UALA2011032101336Control Unit · faultySDCU FAULT DISPLAYED ON UPPER ECAM - WILL NOT CLEAR. REPLACED SDCU. OPS CHECKED GOOD.SDR UALA2011030201023Window · delaminated1ST OFFICER'S FIXED SIDE WINDOW'S VISIBILITY IS AFFECTED BY DEFECTS, DELAMINATION ON F-O FIXED SIDE WINDOW. REPLACED WINDOW.SDR UALA2011022500940Slide · out of toleranceREPLACED BOTH LT & RT OVERWING SLIDES DUE TO PAINT COVERING THE BALL LOCK ASSY. REPLACED LT & RT OVERWING SLIDE IAW MM. LIGHT CHECKED GOOD.SDR UALA2011011000129Control Panel · erraticL2 DOOR F/A LIGHTING CONTROL PANEL ACTING ERRATIC OR UNRESPONSIVE. REPLACED CONTROL PANEL. TESTED OKAY.SDR UALA2010101103763Engine · making metalNR1 ENGINE STALL, RTFL. FOUND METAL IN TAIL PIPE AND IN 7TH STAGE BLEED VALVE SCREEN. REPLACED ESN V10165 WITH ESN V10323 IN POS 01.SDR UALA2010062802273Girt Bar · out of toleranceDOOR 1RT GIRT BAR MISSING ARMING INDICATOR SUPPORT AND INDICATOR. REPLACED GIRT BAR. DOOR ARMING CHECKED NORMAL. ACP INSP OF INSTALLATION.SDR UALA2010050601548Smoke Detector · faultyECAM DISPLAYS SMOKE LAV + CRG DET FAULT. REPLACED SDCU PER MM. RESET CIDS AND SYSTEM TESTS NORMAL.SDR UALA2009060801623Warning System · activatedAFT CARGO DISPLAYED ON UPPER ECAM SCREEN.SDR UALA2009032700905Actuator · faultyCREW REPORTS LEFT PACK IS OVERHEATING AND HAVING MULTIPLE PROBLEMS. REPLACED LEFT PACK AIR OUTLET FLAP ACTUATOR REPLACED RT PACK INLET DOOR ACTUATOR BECAUSE RT INLET DOOR ACTUATOR WAS CYCLING BACK AND FORTH. INSTALLED NEW AIR INLET DOOR (FLAP) ACTUATOR, OPS SDR 2008UALA03459Rod End · wornAIRFRAME VIBRATION ON CLIMBOUT. *S/D* LEFT OUTBOARD BLUE ELEVATOR ACT ROD END HAS PLAY. REPLACED LT OUTBOARD ELEV ROD.