N802UA
Service difficulty reports · 124
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N802UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N802UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2008UALA02449Transducer · leakingDURING TOW TO GATE, NOTICED CREW OXYGEN PRESSURE DROPPING FROM 1580 TO 1500, FOUND LEAK TO BE AT SERVICE PORT. REPLACED PRESSURE REGULATOR/TRANSDUCER, NO LEAKS WERE NOTED AFTER SERVICING.SDR 2007UALA04963Battery · dischargedAFT JUMP SEAT EMERGENCY FLASH LIGHT RED STS LIGHT DOES NO BLINK. FOUND RECHARGEABLE BATTERY INOPERATIVE. REPLACED FLASH LIGHT BATTERY, OPS CHECKED GOOD.
SDR 2007UALA04538Oxygen System · reads low02 LOW REQUIRES SERVICING. SERVICED CREW O2 SYSTEMSDR 2007UALA04447Unknown · unknownDURING TAXI AIRCRAFT TENDS UNSAFELY TO THE RIGHT. ALSO BRAKE TEMP WENT UP TO 185 DEG VS 35 DEG ON OPPOSITE SIDE TO KEEP NOSE CENTERED ONLINE. REPLACED SEVERAL PARTS AND COMPONENTS, LASTLY A NOSE WHEEL STEERING SERVO CONTROL UNIT WHICH BROUGHT THE A/C BACK ISDR 2007UALA04303Battery · faultyDURING EMERGENCY LIGHT SYSTEM TEST ON PTP PANEL, TEST FAILED FAULTING LEFT AFT ESPU BATTERY. 11-01-07 REPLACED EPSU.SDR 2007UALA02737Power Supply · faultyWHILE PERFORMING CABIN EMERGENCY LIGHTING CHECK RECEIVED MESSAGE -EPSU INT LOAD AFT-L- ON FWD ATTENDANT PANEL. RESET AFT GALLEY CEILING AREA POWER SUPPLY. TEST PASS.SDR 2007UALA02592Smoke Detector · inoperativeFWD LAV SMOKE DETECTOR INOP (TEST INOP). REPLACED FWD LAVATORY SMOKE DETECTOR.SDR 2007UALA00939Power Supply · inoperativeDOOR 2R EMERGENCY EXIT LIGHT PLATE LOWER RIGHT SIDE INOP DURING TEST. SECURED & REPLACED POWER SUPPLY BATTERY. SYSTEM OPERATES NORMALLY.SDR 2007UALA00760Girt Bar · out of adjustAFT GIRT BAR FLOOR FITTING CLEARANCE OUT OF ADJUSTMENT. [SUP 06-01-07] FOUND THAT THE GIRT BAR FLOOR FITTINGS WERE OUT OF ADJUSTMENT AND NOT ALLOWING THE GIRT BAR TO FREELY MOVE FROM THE DOOR FITTINGS TO THE SILL FITTINGS. THE FLOOR STRUCTURE AROUND DOOR 2R SDR 2007UALA00707Sill · corrodedR-2 DOOR SILL PLATE HAS CORROSION AT CLIP NUT HOLE BETWEEN FR 65 AND 66. MAJOR REPAIR ACCOMPLISHED: REPLACED SILL PLATE.SDR 2007UALA00636Floor Support · corrodedCORROSION FOUND ON FLOOR STRUCTURE UNDER AFT GALLEY. (SUP 05-24-07] ATTEMPT TO BLEND OUT CORROSION RESULTED IN EXCESSIVE MATERIAL LOSS AND STRUCTURE OUTSIDE OF ALLOWABLE DAMAGE LIMITS. AFFECTED FLOOR STRUCTURE WAS CUTOUT AND REPAIRED IN ACCORDANCE WITH SRM. SDR 2006UALA02052Power Supply · faultyEMERGENCY EXIT LIGHT FLASHING ON AND OFF OVER DOOR 2R. REPLACED EPSU, OPS CHECKED OK.SDR 2006UALA02019Battery Pack · failedFWD FLIGHT ATTENDANT STATION CIDS FAILS EMERGENCY LIGHT TEST ON FWD L COMM. REPLACED BATTERY PACK FWD EMERGENCY LIGHT CONTROL. SYSTEM TESTS GOOD.SDR 2006UALA01460Light · inoperativeFOUND EMERGENCY ESCAPE PATH LIGHT INOP AT SEAT 9LT. RELAMPED LIGHT OK.SDR 2006UALA01429Power Supply · failedDURING 3 SVC CHECK, EMERGENCY LIGHTS CHECK FAILED. SHOWED EPSU INT LOAD AFT L.SDR 2006UALA01205Rod End · wornRANDOM DEEP SHUDDER FELT INFLIGHT THROUGHOUT ENTIRE AIRCRAFT. SHUDDER OCCURRED NUMEROUS TIMES IN CLIMB, CRUISE, AND DESCENT FROM 15,000' T0 23,000'. ACTUATOR ELEVATOR ROD ENDS OUT OF LIMITS. REPLACED WORN ROD ENDS. PERFORMED ADJUSTMENT AND TEST. BOTH LT ANDSDR 2006UALA00325Power Supply · failedEMERGENCY EXIT LIGHT TEST FAILED DURING TEST FOR 3SVC. REPLACED 10WL EMERGENCY LIGHT POWER SUPPLY. TESTED OK.SDR 2004UALA00002Bypass Valve · leakingFLIGHT DIVERTED DUE TO LOSS OF GREEN HYDRAULIC SYSTEM. FOUND NOSE LANDING GEAR BYPASS VALVE LEAKING, REPLACED BYPASS DOOR . ACCOMPLISHED GEAR SWING ALL GEAR OPERATIONS CHECK NORMAL.SDR 2002UALA01561Valve · leakingLOST GREEN HYDRAULIC PRESSURE AND QUANTITY ON TAXI OUT. RETURNED TO GATE UNDER TOW. SUPPLEMENTAL DATA UPDATE #2 MAIN LANDING GEAR DOOR GROUND OPENING BYPASS VALVE LEAKING. REPLACED VALVE ASSEMBLY.SDR 2000UALA00663Skin · puncturedDUE TO CONTACT WITH GROUND EQUIPMENT, THE VERTICAL STABILIZER LT SIDE SKIN SUSTAINED SCRATCH, PUNCTURE AND DELAMINATION DAMAGE FROM AFT OF S-2 TO S-4, AND OVER A 7 INCHES REGION UP FROM RIB 4. THE SKIN ATTACH AND BOUND FLANGES OF S-3 WERE DAMAGED ABOUT 6 INCHSDR 2000UALA00225Power Supply · failedEMERGENCY LIGHT TEST FAULT, EPSU COMM AFT L 33-51-38. *S/D* REPLACED AFT LEFT EMERGENCY POWER SUPPLY UNIT (P/N 3214-54-10), (S/N 1576).SDR 99UAL900463Engine · failedJUST PRIOR TO GEAR EXT, STRONG ODOR (LIKE HOT A-C DUCT) PERMEATED CABIN CAUSING BURNING EYES AND NOSE. AFTER EXTENSIVE TROUBLESHOOTING AND REPLACEMENT OF TWO ENGINES, AN OIL RESIDUE AND FINE WHITE METALLIC POWDER RESIDUE WAS FOUND IN THE NR 2 IAE V2500, ENGINSDR 99UAL900401Bearing · failedNR 1 ENG IN-FLIGHT SHUTDOWN. CREW REPORTS COMPRESSOR STALL, FOLLOWED BY VIBRATION. RETARDED THROTTLE AND EXPERIENCED ANOTHER COMPRESSOR STALL. *S/D* NR 3 BEARING FAILED, CAUSING SECONDARY DAMAGE TO THE INLET GEARBOX AND HIGH PRESSURE COMPRESSOR MODULE. INSDR 99UAL900021Metering Port · leakingNR 1 ENG LEAKING STREAM OF FUEL WHEN ENG RUNNING. APPEARS TO BE FROM FUEL METERING PORT ON BOTTOM DRAIN FIN. FUEL METERING UNIT LEAKING FROM DRAIN MAST. NOT A NEW PROBLEM. MRR NOT REQUIRED. COA IN PROCESS TO REDUCE FUEL LEAKS.
Back to N802UA