N813SK
Service difficulty reports · 300
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N813SK' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N813SK' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA2025112576491Hinge · wornFLOATATION VALVE IN THE AEB, HINGE IS WORN AND HINGE PIN HAS MIGRATED. REPLACED AND INSTALLED NEW HINGE, WATER ACTIVATED CHECK VALVE IAW DWG.BA690-95100, REV-B, AND SRM.51-42-06-001-001-A01 REV. 38 . LEAK CHECK GOOD. COMPLIED WITH TASK CARD 51-900-1002-SKY.SDR SWIA2025112576489Bracket · crackedRIGHT LWR TRANSCOWL INBD A BRACKET IS CRACKED. RT LWR TRANSCOWL I/B A BRACKET HAS BEEN REPLACED WITH A NEW BRACKET IAW REO# 670-54-21-971, REV B. COMPLIED WITH TASK CARD 51-900-1002-SKY.SDR SWIA2025112576483Stand Off · crackedLEFT UPPER TRANSCOWL INBD A BRACKET IS CRACKED. REMOVED CRACKED INBD A BRACKET STANDOFF FROM LT UPPER TRANSCOWL AND INSTALLED 1 EA NEW INBD A BRACKET STANDOFF ON L/H UPPER TRANSCOWL, REF. MHIRJ GREO #670-54-21-971 REV (-B) DATED 2023-11-28 STEPS 1-3. COMPLIED SDR SWIA2025112576471Rivet · shearedRIGHT LWR TRANSCOWL Z STIFFENER RIVETS ARE SHEARED. RT LWR TRANSCOWL ZEE STIFFENER HAS BEEN REPAIRED REF REO 690-54-21-612, REV --. COMPLIED FULLY W/SKYCARD 51-900-1002-SKY.SDR SWIA2025112576467Retainer · crackedPAX DOOR TOP CORNER AFT SEAL RETAINER CRACK. PERFORMED LOCATE AND DRILL NEW PAX DOOR TOP CORNER AFT SEAL RETAINER. IAW SRM 51-42-06-001-001-A01AND DWG 601R31871 REV. D. INSTALLED PAX DOOR TOP CORNER AFT SEAL RETAINER IAW SRM 51-42-06-001-001-A01. AND DWG 60SDR SWIA2025112476592Vane · wornRIGHT INBD FLAP VANE ACTUATOR BEAM WORN AT FLAP STATION 140.4. REPAIRED RIGHT INBD FLAP VANE ACTUATOR BEAM (OUTER TUBE) AT FLAP IAW REO 670-57-52-257, REV -B. COMPLIED WITH ALL STEPS OF REO 670-57-52-257 REV -B. OPS CHECK GOOD. COMPLIED WITH TASK CARD 51-9SDR SWIA2025112476579Bracket · corrodedFORWARD ECS COMPARTMENT, FS677 STGR19L HAS A BRACKET/CLIP WITH CORROSION, REMOVED AND REPLACED CORRODED CLEAT AT BS 677, S19L WITH NEW CLEAT IAW SRM 51-42-06-001-001-A01 REVISION 38 AND DWG SH690-35070 REV R. COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY.SDR SWIA2025112476577Frame · corrodedFS581.00 CORRODED AT STGR18L. INSTALLED NEW STUB FRAME AT FS581.00 AT STR18L IAW DWG SH690-33750 REV: AF AND SRM 51-42-06-001-001-A01 AND SRM 51-42-21-001-001-A01. COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY. LEAK CHECK GOOD.SDR SWIA2025112476532Stringer · corrodedMAIN AVIONICS BAY, FS364-FS379 STG21R HAS CORROSION, REMOVED CORRODED AND INSTALLED NEW MAIN AVIONICS STR 21R BETWEEN FS333 TO FS379. IAW SRM 51-42-06-001-001-A01 AND DWG SH690-31350 REV. M. LEAK CHECK GOOD COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY.SDR SWIA2025112476510Beam · damagedRIGHT INBOARD FLAP VANE ACTUATOR BEAM (OUTER TUBE) HAS WEAR DAMAGE AT FLAP STATION 24.0. REPAIRED RIGHT WING INBOARD FLAP VANE ACTUATOR BEAM (OUTER TUBE) AT FLAP STATION 24.0 IAW REO 670-57-52-257 REV -B. COMPILED WITH ALL STEPS OF REO 670-57-52-257 REV -B. SDR SWIA2026070606499Angle · corrodedRIGHT WHEEL WELL FORWARD TIRE BURST ANGLE CORRODED. REMOVED AND INSTALLED NEW RT WHEEL WELL FWD TIRE BURST ANGLE IAW SRM 51-42-21-001-001-A01 AND DWG CC670-10320, REV -F. COMPLIED WITH TASK CARD 51-900-1002-SKY.SDR SWIA2025112476485Beam · damagedRIGHT INBOARD FLAP VANE ACTUATOR BEAM (OUTER TUBE) HAS WEAR DAMAGE AT FLAP STATION 102.9. REPAIRED RIGHT HAND INBOARD FLAP VANE ACTUATOR BEAM (OUTER TUBE) AT FLAP STATION 102.9 IAW REO 670-57-52-257 REV -B DATED 2024-10-17. COMPLIED WITH ALL STEPS OF REO 670SDR SWIA2025112476468Tube · wornRIGHT INBD FLAP VANE ACTUATOR BEAM (OUTER TUBE) HAS WEAR DAMAGE AT FLAP STATION 65.5. REPAIRED RIGHT HAND INBOARD FLAP VANE ACTUATOR BEAM (OUTER TUBE) AT FLAP STATION 65.5 IAW REO 670-57-52-257 REV -B. COMPLIED WITH ALL STEPS OF REO 670-57-52-257 REV -B, COSDR SWIA2025112376575Frame · corrodedBS 613 CORRODED AT S18L. REPAIRED FRAME AT BS 613, S18L WITH NEW FRAME SECTOR IAW SRM 53-00-06-201-001-A03, SRM 51-42-06-001-001-A01, SRM 51-42-21-001-001-A01 AND DWG SH690-33100 REV N, COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY. LEAK CHECK GOOD.SDR SWIA2026070676563Frame · corrodedFS533.00 CORRODED AT STGR18L. REPAIRED CORRODED FRAME SECTOR ON FS533 AT STR18L USING NEW FABRICATED FRAME SECTOR, REF CRJ 900 SRM 53-00-06-201-001-A03; 51-42-21-001-001-A01; 51-42-06-001-001-A01 REVISION 38: JUL 25/2020 AND COMPLIED WITH ALL STEPS OF REO #SDR SWIA2025112376561Door Sill · corrodedR/H SILL TAB BETWEEN FS748.00 - FS785.00 HAS CORROSION. REMOVED CORROSION 3 LOCATIONS ON RT FLOOR ANGLE APPROX. BS 748- 785 REF: SRM 51-21-06-001-001-A01, COMPLIED WITH REO 690-53-41-575, REV--, COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY.SDR SWIA2025112376559Tab · corrodedR/H SILL TAB BETWEEN FS720.00 - FS744.00 HAS CORROSION AS MARKED (C-CHECK RO 07/02/2026)REMOVED CORROSION (3 LOCATIONS) ON RH FLOOR ANGLE FS720-FS744. REF: CRJ 900 SRM 51-21-06-001-001-A01 AND COMPLIED WITH REO 690-53-41-575, REV--, DATE:2026/01/01. COMPLIEDSDR SWIA2026070676551Tab · corrodedRT SILL TAB AT APPROXIMATELY BS 813 HAS CORROSION. REPAIRED RT SILL TAB AT APPROXIMATELY BS 813 IAW REO 690-53-41-575 REV --. COMPLIED WITH ALL STEPS OF REO 690-53-41-575 REV -- . COMPLIED WITH TASK CARD 51-900-1002-SKY.SDR SWIA2026060776549Frame · corrodedFS549.00 CORRODED AT STGR18L AS MARKED (C-CHECK RO 07/02/2026)PERFORMED FRAME SECTOR REPAIR TO FS 549 STR 18L TO STR 14L REF. CRJ900 SRM 51-42-06-001-001-A01 AND CRJ900 SRM 51-42-21-001-001-A01 AND CRJ 900 SRM 53-00-06-201-001-A03 AND DWG# SH690-33100 REV: SDR SWIA2026070676542Stringer · corrodedCORROSION ON STGR22L BETWEEN FS501.00 AND FS517. REMOVED AND INSTALLED NEW STGR AT 22L FS477.00 TO FS517.00 IAW SRM 51-42-21-001-001-A01, SRM 51-42-06-001-001-A01 AND DWG SH690-33200 REV: N. PERFORMED LEAK CHECK IAW SRM 51-23-03-001-001-A01. LEAK CHECK GOOD SDR SWIA2025112376530Angle · elongatedFS280.00 LH BULKHEAD, THE AFT BOTTOM ANGLE THAT IS ATTACHED TO THE CROSSBEAM, THE FASTENER HOLES ARE ELONGATED AND BENT. REMOVED AND REPLACED WITH NEW LT CORROSION CAP PART CC670-34096-1S AT FS 280.00 REF SRM 51-42-10-001-001-A01 AND DWG CC670-34010 REV -K, SDR SWIA2025112376525Hinge · chafedPAX DOOR SURROUND STRUCTURE HAS CHAFFING ON EXTERNAL SKIN FWD OF PIANO HINGE. BLENDED CHAFFING FROM PAX DOOR SURROUND STRUCTURE EXTERNAL SKIN FWD OF PIANO HINGE SRM 51-12-00-001-001-A01. PERFORMED REPAIR IAW ALL STEPS OF REO 690-53-21-2072 REV -. COMPLIED WITHSDR SWIA2026070676524Striker · gougedPAX DOOR SURROUND STRUCTURE SEAL STRIKER LOWER EDGE HAS MULTIPLE GOUGES/CHAFFING. REMOVED CHAFED SEAL STRIKER AND INSTALLED NEW PAX DOOR SURROUND STRUCTURE SEAL STRIKER LOWER. IAW SRM 51-42-06-001-001-A01. AND DWG SH670-31810 REV. AE. COMPLIED WITH SKYWEST TASDR SWIA2025112376505Stringer · corrodedCORROSION ON STRINGER 19R BETWEEN BS 469 AND 485. INSTALLED A NEW STRINGER IAW DWG SH670-31070, REV J AND SRM 51-42-06-001-001-A01. COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY, LEAK CHECK GOOD.SDR SWIA2025112376498Skin · chafedBS 913 - 927, STRINGER 27, THE AFT BODY FAIRING HAS CHAFED THE FUSELAGE EXTERIOR SKIN. REPAIRED FUSELAGE EXTERIOR SKIN AT BS 913 - 927 STRINGER 27 IAW REO 690-53-51-533 REV-. COMPLIED WITH ALL STEPS OF REO 690-53-51-533 REV-- AND REO 670-53-00-290 REV F. COMPSDR SWIA2025112376490Stringer · corrodedCORROSION ON S24L BETWEEN FS 501 AND 517. REMOVED AND INSTALLED NEW S24L BETWEEN BS 501 AND 517 IAW SRM 51-42-21-001-001-A01, SRM 51-42-06-001-001-A01 AND DWG SH690-33200 REV: N. COMPLIED WITH TASK CARD 51-900-1002-SKY. PERFORMED LEAK CHECK IAW SRM 51-23-03-SDR SWIA2025112376488Frame · corrodedCORROSION BS 501AFT SIDE BETWEEN S23L AND S26R. REMOVED AND INSTALLED NEW FRAME AT FS501.00 FROM STGR 25L TO STGR 19L IAW DWG SH690-33750 REV: AF, SRM 51-42-06-001-001-A01 AND SRM 51-42-21-001-001-A01. PERFORMED LEAK CHECK IAW SRM 51-23-03-001-001-A01. LEAK CSDR SWIA2025112376486Frame · corrodedFS280.00 STRG 24LH - 23RH CIRCUMFERENTIAL JOINT STRAP HAS AREAS OF CORROSION. REPAIRED CIRCUMFERENTIAL JOINT STRAP AT BS 280 S24L - 23R IAW REO 690-53-21-2075 REV -. COMPLIED WITH ALL STEPS OF REO 690-53-21-2075 REV -. PERFORMED LEAK CHECK IAW SRM 51-23-03-SDR SWIA2025112376484Crossbeam · gougedRIGHT CROSSBEAM HAS GOUGES AT FS 669. REMOVED DAMAGE FROM RT CROSSBEAM AT FS 669.00 IAW SRM 51-12-00-001-001-A01. OUT OF LIMITS IAW SRM 53-31-43-101-001-A06. RECEIVED AND COMPLIED WITH ALL STEPS OF REO 690-53-31-1103 REV: --. COMPLIED WITH SKYWEST TASKCARD 5SDR SWIA2025112376479Attach Angle · crackedBS 280, RBL 12, THE CROSSBEAM-TO-FLOOR BEAM OUTBD ATTACH ANGLE CRACKED IN THE UPPER RADIUS. REMOVED AND REPLACED WITH NEW OTBD ATTACH ANGLE AT BS 280, RBL 12 IAW SRM 51-42-21-001-001-A01 AND DWG CC670-34010 REV -K, AND LOCATED AND DRILLED NEW ATTACH ANGLE SRMSDR SWIA2025112376464Intercostal · corrodedINTERCOSTAL CORRODED BETWEEN STRINGER26 - 27L BETWEEN BS 501 AND 517. REMOVED AND INSTALLED NEW REPLACEMENT ANGLE FOR INTERCOSTAL ON S27-26L BETWEEN BS 501 - 517 IAW SRM 51-42-06-001-001-A01 AND DWG SH670-33399 REV -B. PERFORMED LEAK CHECK IAW SRM 51-23-03-00SDR SWIA2025112376462Structure · crackedLEFT FORWARD OVERWING EMERGENCY-EXIT DOOR TOP EDGE MEMBER SUSPECTED CRACKED AT AFT TANG FITTING. VERIFIED CRACK ON LEFT FORWARD EMERGENCY EXIT DOOR TOP EDGE MEMBER. PERFORMED ALL STEPS OF REO 670-52-21-103 REV-- FOR REPAIR. COMPLIED WITH SKYWEST TASK CARD 51-SDR SWIA2025112376460Floorbeam · corrodedBS 280, LBL 12 - RBL 12, THE COCPIT FLOOR PANEL AFT ATTACH ANGLE, ON THE BEAM, IS CORRODED. FOUND EXFOLIATED CORROSION 100% MATERIAL LOSS. FOUND OUT OF LIMITS IAW SRM 53-00-00-101-001-A01. REMOVED COCKPIT FLOOR SUPPORT ANGLE IAW SRM 51-42-21-001-001-A01 AND SSDR SWIA2025112376458Floor Support · corrodedPAX DOOR SURROUND STRUCTURE FLOOR SUPPORT ANGLE HAS MULTIPLE AREAS OF CORROSION BETWEEN APPROX. BS 310 - 349. INSTALLED NEW PAX DOOR SURROUND STRUCTURE FWD AND MID CAP ANGLES IAW SRM 51-42-06-001-001-A01, AND DWG SH670-31810, REV AE COMPLIED WITH TASK CARD 51SDR SWIA2025112376456Stringer · gougedPAX DOOR SURROUND STRUCTURE SEAL STRIKER HAS GOUGES & CHAFED AT APPROX. BS 310, STGR 5L - 7L. TRIMMED OUT DAMAGE ENSURED NO DAMAGE TO UNDERLYING STRUCTURE AND REMOVED ALL BURRS AND SHARP EDGES IAW REO 670-53-22-001, REV J. FABRICATED STRAP IAW REO 670-53-22-SDR SWIA2025112376448Fitting · corrodedPAX DOOR SURROUND STRUCTURE FWD HANDRAIL FITTING CORRODED. REMOVED AND INSTALLED NEW PAX DOOR SURROUND STRUCTURE FWD HANDRAIL FITTING IAW SRM 51-42-21-001-001-A01 AND DWG SH670-31810 REV. AE. COMPLIED WITH TASK CARD 51-900-1002-SKY.SDR SWIA2026070676451Frame · crackedFRAME, BS 333 CRACKED AT STRINGER 0. CRACK EXISTS ON WEB AT BS 333, STR 0 . DAMAGE IS OUT OF LIMITS DUE TO NO CRACKS ALLOWED IN WEB IAW SRM 53-21-06-101-004-A04. COMPLIED WITH ALL STEPS OF REO 690-53-21-2070 FOR REPAIR. SEE CONTINUE CARD FOR WORK PERFORMED. CSDR SWIA2025112176584Stringer Splice · corrodedSTRINGER SPLICE 25L AT FS333 HAS CORROSION MX. REMOVED AND INSTALLED NEW MAIN AVIONICS STR 25L SPLICE AT BS 333 IAW SRM 51-42-06-001-001-A01 AND DWG SH670-32420 REV E. PERFORMED PRESSURE LEAK CHECK IAW SRM 51-23-03-001-001-A01. LEAK CHKD GOOD. COMPLIED WITH SDR SWIA2025112176580Floor Support · corrodedRBL 9 BETWEEN BS 1000.00 TO 1060.00 CORRODED ON TOP SURFACE OF SUPPORT. REMOVED AND INSTALLED NEW FLOOR SUPPORT SECTION AT RBL 9 FROM BS 977 TO 1075 IAW SRM 53-00-41-201-001-A03 AND REO 690-53-61-1707, REV-. STEP 1, 2, 3, 4, 5. COMPLIED WITH TASK CARD 51-900-SDR SWIA2025112176573Floor Support · corrodedLBL9.00 BETWEEN BS 977.00 TO 1088.20 HAD CORROSION ON TOP SURFACE OF BEAM. REMOVED AND INSTALLED NEW LBL 9 FLOORBEAM SECTION FROM BS 977 TO 1081.5 IAW SRM 53-00-41-201-001-A03 AND REO 690-53-61-1707 REV.- STEPS 1, 2, 3, 4 AND 5. COMPLIED WITH TASK CARD 51-9SDR SWIA2025112176570Door Sill · corrodedLEFT SILL BETWEEN BS 1000 - 1047 HAS CORROSION. INSTALLED NEW AFT CARGO DOOR LOWER SILL, IAW SRM 51-42-06-001-001-A01, SRM 51-42-13-001-001-A01, SRM 51-42-21-001-001-A01 AND DWG MM670-35085, REV. L. LEAK CHECKED GOOD. COMPLIED WITH SKYWEST TASK CARD 51-900-1SDR SWIA2025112176543Vent · corrodedLEFT CABIN FLOOR VENT HAS CORROSION BETWEEN FS1088.20 - FS1098.20. LT CABIN FLOOR VENT BRACKETS CORROSION HAS BEEN REPAIRED BY PERFORMING ALL STEPS OF REO 690-53-61-1712 REV-- .COMPLIED WITH TASK CARD 51-900-1002-SKYSDR SWIA2025112176527Vent · corrodedRIGHT CABIN FLOOR VENT HAS CORROSION, BETWEEN BS 1088.20 - BS 1098.20. RIGHT CABIN FLOOR VENT BRACKET CORROSION HAS BEEN REPAIRED IAW ALL STEPS REO 690-53-61-1712 REV-. COMPLIED WITH TASK CARD 51-900-1002-SKY.SDR SWIA2025112176518Floor Support · corrodedLBL 27 BETWEEN BS 977 TO 1088.20 HAS CORROSION ON TOP SURFACE OF BEAM. REMOVED AND INSTALLED INSTALLED NEW FLOOR BEAM SECTON AT LBL 27 FROM BS 977 TO 1055 IAW SRM 53-00-41-201-001-A03 AND COMPLIED WITH TASK CARD 51-900-1002-SKY.SDR SWIA2020706076506Stringer Splice · corrodedSTRINGER SPLICE 26L AT BS 333 HAS CORROSION. REMOVED AND INSTALLED A NEW MAIN AVIONICS STRINGER SPLICE IAW SRM 51-42-06-001-001-A01 AND DWG SH670-32420 REV E. COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY. PERFORMED PRESSURE LEAK CHECK IAW SRM 51-23-03-001-SDR SWIA2025112176463Support · corrodedLT SILL BETWEEN BS 985 - 1000 HAS CORROSION. REMOVED CORROSION ON LT SILL BS 985 - 1000. IAW SRM 51-21-06-001-001-A01. EVALUATED OUT OF LIMITS IAW SRM 53-61-23-101-001-A01. PERFORMED ALL STEPS OF REO 690-53-61-1717 REV -. COMPLIED WITH TASK CARD 51-900-1002-SDR SWIA2025112176452Bracket · bentBRACKET ATTACHED TO INTERCOSTAL BETWEEN BS 1031 TO 1047 ABOVE STR 27 BENT. REMOVED THE DAMAGE BRACKET IAW SRM 51-42-06-001-001-A01. INSTALLED A NEW BRACKET IAW SRM 51-42-06-001-001-A01, AND DWG MM670-36084, REV D.SDR SWIA2025112076511Attach Angle · corrodedATTACH ANGLE AT STR 26L BETWEEN FS349 -FS364 HAS CORROSION. INSTALLED NEW MAIN AVIONICS ATTACH ANGLE STR 26L BETWEEN BS 333 - 364 IAW SRM 51-42-06-001-001-A01, SRM 51-42-21-001-001-A01 AND DWG SH670-32050, REV J. COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKSDR SWIA2025112076487Stringer · corrodedSTR 26L BETWEEN FS333 - FS364 HAS CORROSION. INSTALLED NEW MAIN AVIONICS STR 26L BETWEEN FS333 - FS364 REF CRJ-900 SRM 51-42-06-001-001-A01 AND DWG SH690-31350 REV M. LEAK CHECK GOOD, COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY.SDR SWIA2025112076469Web · crackedPOSSIBLE CRACK IN LT TRU BAY ON WEB FLOOR. PERFORMED REPAIR IN LT TRU BAY ON WEB FLOOR IAW REO 670-53-11-509, REV-E. COMPLIED WITH TASK CARD 51-900-1002-SKY.
Back to N813SK