What was found
BS 280, LBL 12 - RBL 12, THE COCPIT FLOOR PANEL AFT ATTACH ANGLE, ON THE BEAM, IS CORRODED. FOUND EXFOLIATED CORROSION 100% MATERIAL LOSS. FOUND OUT OF LIMITS IAW SRM 53-00-00-101-001-A01. REMOVED COCKPIT FLOOR SUPPORT ANGLE IAW SRM 51-42-21-001-001-A01 AND SRM 51-42-06-001-001-A01. INSTALLED NEW COCKPIT FLOOR SUPPORT ANGLE IAW SRM 51-42-21-001-001-A01, SRM 51-42-06-001-001-A01 AND DWG CC670-34010, REV -K. COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY.