N8309C
Service difficulty reports · 193
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N8309C' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N8309C' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2023121117297Floor Panel · frayedPASSENGER CABIN FLOOR - FRAYED FIBERS ON OUTER FACESHEET 241UF FLOOR PANEL (MARKED)<[01] FLOOR PANEL 241UF NEW PANEL WAS FABRICATED ON FAULT TTG8Q00PEADM;[02] VERIFIED CORRECTIVE ACTION 1 AND THE MEASUREMENT TABLE.SDR SWAA2023121116549Shield · corrodedREJECT: FWD CARGO BAY AFT SHEILD HAS CORROSION AT BS 480+15 - 500+16; RBL 23; WL 155; WILL BE COMPLETED ON THIS TASK CARD.<[01] REMOVED AND REPLACED FCB BAY AFT NEW SHIELD AT RBL 23 WL 155 BS 480+15 TO BS 500A IAW SRM 51-40-02 AND DWG 143A0080 REV: -;[02] VERISDR SWAA2023120816878Attach Angle · crackedMAIN EBAY OXYGEN BOTTLE FWD SUPPORT ATTACH ANGLE CRACKED BS362 RBL5 WL157.<[01] NO ALLOWABLE DAMAGED NOTED ON SRM. PART TO BE REPAIR BY REPLACEMENT I.A.W SRM 51-10-02-0G-0 PARA 9.<BR><BR>PROCURED NEW OXYGEN BOTTLE FWD SUPPORT; REMOVED AND REPLACED I.A.W SRM 51SDR SWAA2023120816775Intercostal · crackedCRACKED INTERCOSTAL AT FWD CABIN BS390 BL0 WL208.<[01] UPDATED MEASUREMENT TABLE;[02] CERTIFIED;[03] REMOVED AND REPLACED INTERCOSTAL AT BS380 TO BS 400 BL0; WL208 PER SRM 51-40-02-0G-0 AND DWG:143A5400.;[04] VERIFIED CORRECTIVE ACTION COMPLETE WITH MEASUREMENSDR SWAA2023120816778Intercostal · crackedCRACKED INTERCOSTAL AT FWD CABIN BS387 LBL13 WL208.<[01] UPDATE TABLE;[02] CERTIFIED;[03] REMOVED AND REPLACED INTERCOSTAL AT BS380 TO BS 400 LBL 13; WL208 PER SRM 51-40-02-0G-0 AND DWG:143A5400.;[04] VERIFIED CORRECTIVE ACTION COMPLETE WITH MEASUREMENTSSDR SWAA2023120816774Angle · crackedCRACKED ATTACH ANGLE AT FWD CABIN BS293 RBL54 WL208. MARKED.<[01] REMOVED AND REPLACED ANGLE AT BS 293 RBL54 WL208 PER SRM 51-40-02-0G-0 AND BOEING DWG 141A8310.;[02] VERIFIED CORRECTIVE ACTION COMPLETE WITH MEASUREMENTSSDR SWAA2023120816777Frame · crackedPASSENGER CABIN FED UPPER FRAME BS 312 STR 5L CRACKED<[01] UPDATED MEASUREMENT TABLE;[02] EDIT TO #3 STEP IN MEASUREMENT FIELD.;[03] CERTIFY TABLE EDIT CHANGE; ITEM 3;[04] VERIFIED MEASUREMENT TABLE.;[05] WORK ACCOMPLISHED ON TTG8Q00PD7SZ;[06] CORRECT FAULT FOSDR SWAA2023121116449Web · corrodedAFT CARGO DOOR CENTER THRESHOLD HAS CORROSION FROM BS 807+18 - BS 787+8; RBL 21-28; WL 157<[01] ACCOMPLISHED AND REPLACED THRESHOLD WEB AT ACB BETWEEN BS 794 TO BS 847 ; RBL 21 TO RBL 28; WL 157 IAW SRM 511-40-02 AND DWG:146A8340;ID:0028;REV:-.;[02] VERIFIED CSDR SWAA2023121116443Shield · corrodedAFT CARGO FWD SHEILD HAS CORROSION AT BS 767- 787; RBL 22; WL 156<[01] COMPLETED TASK CARD.;[02] VERIFIED COMPLETION OF CORRECTIVE ACTIONS 1 AND MEASUREMENT TABLE.SDR SWAA2023121116452Support · corrodedAFT CARGO AFT BULKHEAD SUPPORT HAS CORROSION AT BS 947; RBL 10-20; WL 178<[01] NO ALLOWABLE DAMAGE NOTED ON SRM. PART TO BE REPAIR BY REPLACEMENT. PER SRM 51-10-02-0G-0 PARA. 9.;[02] UPDATED STEPS 1-3. REQUESTING OKAY TO INSTALL NEW SUPPORT.;[03] VERIFIED CORRSDR SWAA2023121116453Sidewall Support · corrodedAFT CARGO FLOOR TO SIDEWALL SUPPORT HAS CORROSION AT BS 727C+9 - 727H+10; LBL 22; WL 154<[01] VERIFIED CORRECTIVE ACTION TO BE COMPLETED ON TTG8Q00PC7Y3SDR SWAA2023121116447Sidewall Support · corrodedAFT CARGO FLOOR TO SIDEWALL SUPPORT HAS CORROSION AT BS 727C+16 - 727F+3; RBL 22; WL 154<[01] WORK WILL ACCOMPLISH ON CUSTOMER CARD NBR:TTG800PC8QT;[02] VERIFIED CORRECTIVE ACTION STEP 1. VERIFIED MEASUREMENTS TABLE AND TASK CARD COMPLETE.SDR SWAA2023121116448Sidewall Support · corrodedAFT CARGO FLOOR TO SIDEWALL SUPPORT HAS CORROSION AT BS 727H+13 - 807+7; LBL 22; WL 155<[01] ACCOMPLISHED AND REPLACED SIDEWALL SUPPORT AT ACB BETWEEN BS 727 TO BS 847;LBL 22;WL 155 IAW SRM 51-40-02 ; SRM 53-00-53-2R-6 AND DWG:146A75000; ID:0213; REV:-;[02] VESDR SWAA2023121116454Sidewall Support · corrodedAFT CARGO FLOOR TO SIDEWALL SUPPORT HAS CORROSION AT BS 727F+13 - BS 747+19; RBL 22; WL 155<[01] ACCOMPLISHED AND REPLACED SIDEWALL SUPPORT AT ACB BETWEEN BS 727 TO BS 767;RBL 22;WL 155 IAW SRM 51-40-02 ; SRM 53-00-53-2R-6 AND DWG:146A75000; ID:0213; REV:-;[02SDR SWAA2023121116534Threshold · corrodedFWD CARGO BAY DOOR CENTER THRESHOLD HAS CORROSION AT BS 440+16 - 460+19; RBL 29; WL 155<[01] FAULT WRITTEN ON WRONG TASK CARD; CLOSING CARD;[02] FAULT WRITTEN ON WRONG TASK CARD; CLOSING CARDSDR SWAA2023121116544Support · corrodedFWD CARGO BAY FLOOR TO SIDEWALL SUPPORT IS CORRODED AT BS 500D+8 - 500A; LBL 22; WL 155<[01] UPDATED STEP 7.;[02] UPDATED STEP 8;[03] UPDATED STEP 9;[04] REMOVED DAMAGED FLOOR TO SIDEWALL SUPPORT BS 480+8' TO BS 500I; LBL 22;WL 155 INSTALLED NEW SIDEWALL SUPPOSDR SWAA2023121116530Support · corrodedFWD CARGO BAY FLOOR TO SIDEWALL SUPPORT IS CORRODED AT BS 500I - 500A; RBL 22; WL 155<[01] REMOVED DAMAGED FLOOR TO SIDEWALL SUPPORT BS 500A-500I ' THE DAMAGE WAS REPAIRED PER SRM 53-00-53-2R-5 (REPAIR 5) AND EA M-22-153-01550'. SPLICE INSTALLED BS 500B+5' TO SDR SWAA2023121116529Web · corrodedFWD CARGO BAY DOOR CENTER THRESHOLD HAS CORROSION AT BS 440+16 - 460+19; RBL 29; WL 155<[01] ACCOMPLISHED AND REPLACED THRESHOLD WEB AT FCB BETWEEN BS 440 TO BS 492.4;RBL 23 TO RBL 29; WL 155 IAW SRM 51-40-02 ;SRM 53-30-15-1A-1 AND DWG:143A8330;ID:0021;REV:-;[SDR SWAA2023121116531Sidewall Support · corrodedFWD CARGO BAY FLOOR TO SIDEWALL SUPPORT IS CORRODED AT BS 500I - 500D+12; LBL 22; WL 155<[01] SIDEWALL SUPPORT AT FCB BETWEEN BS 500D+12' TO 500I ;LBL 22; WL 155 WILL BE REPLACED ON TASK CARD: TTG8Q00PCE21.;[02] VERIFIED WILL BE REPLACED ON TASK CARD: TTG8Q00PSDR SWAA2023121116548Panel · crackedCRACKED PANEL BRAKE AT PASSENGER CABIN BS540 RBL1 WL208. MARKED.<[01] UPDATED MEASUREMENT TABLE;[02] UPDATED STEPS;[03] EDIT FROM COMPLETE TO PARTIAL;[04] CERTIFY;[05] COMPLETED INSTALL OF PANEL BREAK AT BS 540 RBL1 IAW SRM 51-40-02-0G-0; DWG 143A5240;[06] VERSDR SWAA2023121116547Panel · crackedCRACKED PANEL BRAKE AT PASSENGER CABIN BS540 LBL1 WL208. MARKED.<[01] INSTALLED NEW PANEL BRAKE AT PASSENGER CABIN AT BS540 LBL1 -LBL25 WL208 PER SRM 51-40-02-0G-0 AND 143A5240.;[02] VERIFIED CORRECTIVE ACTION COMPLETE.<BR>VERIFIED MEASUREMENT TABLE.SDR SWAA2023120816446Sidewall Support · crackedAFT CARGO FLOOR TO SIDEWALL SUPPORT IS CRACKED IN RADIUS AT BS 927+19; RBL 24; WL 177<[01] SRM 53-00-53-1A-2 IS APPLICABLE FOR THIS; AFT CARGO FLOOR TO SIDEWALL SUPPORT CRACK FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2; PART WILL BY REPLACEMENT; REMOVED INSDR SWAA2023121116116Web · crackedL-CLIP COMMON TO I/B SIDE OF DEFLECTION CONTROL RIB AND O/B END OF TRANSVERS WEB IS CRACKED RIGHT WING<[01] REMOVED AND REPLACED L-CLIP COMMON TO I/B SIDE OF DEFLECTION CONTROL RIB AND O/B END OF TRANSVERS WEB; P/N 115A6260-2 IAW SRM 51-40-02-0G-0 AND IPC 57-4SDR SWAA2023121116115Rib · crackedRIGHT HORIZONTAL STAB REMOVABLE L/E 341B RIB #5 CRACKED<[01] REMOVED RIB # 5 FROM R/H REMOVABLE L/E 341B IAW SRM 51-40-02-0G-0.;[02] REMOVED AND REPLACED RIB # 5 P/N 186A1305-2; PO # 945387/1 AT R/H REMOVABLE L/E 341B IAW SRM 51-40-02-0G-0 AND DWG. 186A1001.;[SDR SWAA2023121116114Rib · crackedRIGHT HORIZONTAL STAB REMOVABLE L/E 341B RIB #4 CRACKED<[01] REMOVED AND REPLACED R/H HORIZONTAL STAB REMOVABLE L/E 341B RIB #4 IAW SRM 51-40-02-0G-0;[02] TASK COMPLETE.SDR SWAA2023121116113Rib · crackedRIGHT HORIZONTAL STAB REMOVABLE L/E 341B RIB #3 CRACKED<[01] REMOVED RIB #3 FROM R/H REMOVABLE L/E 341B IAW SRM 51-40-02-0G-0.;[02] REMOVED AND REPLACED RIB # 3 P/N 186A1303-2; PO # 826596/1 AT R/H REMOVABLE L/E 341B IAW SRM 51-40-02-0G-0 AND DWG. 186A1001.;[0SDR SWAA2023121116112Rib · crackedRIGHT HORIZONTAL STAB REMOVABLE L/E 341B RIB #1 CRACKED<[01] REMOVED RIB #1FROM R/H REMOVABLE L/E 341B IAW SRM 51-40-02-0G-0.;[02] REMOVED AND REPLACED RIB #1 P/N 186A1301-2; PO # 945786/1 AT R/H REMOVABLE L/E 341B IAW SRM 51-40-02-0G-0 AND DWG. 186A1001.;[03]SDR SWAA2023121115964Slat · corroded#3 SLAT WEDGE CORRODED 50' FROM I/B END ON OPPER FWD SURFACE #3 SLAT WEDGE CORRODED 50' FROM I/B END ON UPPER SKIN AT FWD EDGE<[01] CERTIFY STEP 2;[02] REMOVED AND INSTALLED SLAT #3 ALL STEPS COMPLETED PER AMM 27-81-21-401 AND #3 SLAT REPAIRED ON ATS W/O # 565SDR SWAA2023121125658Slat · corrodedCORRROSION ON #6 SLAT WEDGE UPPER SURFACE FWD EDGE 45' FROM O/B EDGE<[01] REMOVED AND INSTALLED SLAT #6 ALL STEPS COMPLETED PER AMM 27-81-21-401 AND #3 SLAT REPAIRED ON ATS W/O#: 565077;[02] UPDATED INSTALLED PART;[03] VERIFIED CORRECTIVE ACTION 1SDR SWAA2023121115793Floorbeam · corrodedAFT WET AREA - CORROSION AT FLOOR BEAM BS 986.5 RBL 43 WL 208 (MARKED)<[01] REMOVED NUT PLATE AND FOUND CORROSION AT FLOOR BEAM AT BS 986; RBL 43; WL 208. REMOVED CORROSION WITH NEXT MEASUREMENTS L:1.20' W: 1' D: .060' AND FOUND FLOOR BEAM OUT LIMITS PER SRM 5SDR SWAA2023121115795Channel · corrodedAFT WET AREA - CORROSION AT LOWER MOP SILL BS 967+2.5; BS 967+6; BS 967+11; BS 967+13; BS 967+17 LBL 46 WL 208 (MARKED)<[01] UPDATED STEP 10;[02] CERTIFY STEP 10;[03] SUMMARY STATEMENT; REMOVED CORROSION ON MOP SILL BS 967 +25 TO BS 967+17 LBL 46; WL 208; FOUNSDR SWAA2023121115535Floor Support · crackedFLOOR STRUCTURE INTERCOSTAL CRACK; LOCATED AT BL 0.0 BWN STA.294.5 AND STA.277; WL 208<[01] INSTALLED NEW INTERCOSTAL AT BL 0.0 BWN STA.294.5 AND STA.277; WL 208 PER SRM 51-40-02-0G-0 AND DWG 141A5400.;[02] PART REPLACED; JOB COMPLETE.;[03] VERIFIED MEASUREMENSDR SWAA2023121115536Floor Support · crackedFLOOR STRUCTURE INTERCOSTAL CRACK; LOCATED AT LBL 45.5 BWN STA.312 AND STA.328; WL 208<[01] EVALUATED INTERCOSTAL LOCATED AT LBL 45.5 BS 312 TO BS 328 AND WL 208. FOUND INTERCOSTAL OUT LIMITS IAW SRM 53-10-51-1A-1 PAR. 4.B (1)(A) FIG. 105 DETAILS A; B; K AND NSDR SWAA2023121115534Panel · crackedRIGHT WING T/E PANEL 651FB FWD L-CLIP CRACKED ON FWD EDGE 27' FROM O/B EDGE<[01] REMOVED AND REPLACED NEW R/W T/E PANEL 651FB L-CLIP P/N 287A9152-24; PO # 813681/6; IAW SRM 51-40-02-0G-0 AND IPC 57-50-00-38.;[02] VERIFIED CORRECTIVE ACTION STEP 1. VERIFIED MEASDR SWAA2023120815789Floor Panel · frayedAFT. WET AREA FLOOR PANEL 241ABF TOP SURFACE MULTIPLE FRAYED SPOTS.<[01] AFT WET AREA FLOOR PANEL 241ABF TOP SURFACE WITH MULTIPLE FRAYED SPOTS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] PANELSDR SWAA2023120815788Floor Panel · frayedAFT. WET AREA FLOOR PANEL 241F TOP SURFACE MULTIPLE FRAYED SPOTS.<[01] AFT WET AREA FLOOR PANEL 241F WITH TOP SURFACE MULTIPLE FRAYED SPOTS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] PANEL REPSDR SWAA2023120815787Floor Panel · frayedAFT. WET AREA FLOOR PANEL 241E TOP SURFACE MULTIPLE FRAYED SPOTS.<[01] AFT. WET AREA FLOOR PANEL 241E TOP SURFACE WITH MULTIPLE FRAYED SPOTS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] PANEL RESDR SWAA2023120815786Floor Panel · frayedAFT. WET AREA FLOOR PANEL 242E TOP SURFACE MULTIPLE FRAYED SPOTS.<[01] AFT. WET AREA FLOOR PANEL 242E TOP SURFACE WITH MULTIPLE FRAYED SPOTS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] PANEL RESDR SWAA2023120815785Floor Panel · frayedAFT. WET AREA FLOOR PANEL 242VF TOP SURFACE MULTIPLE FRAYED SPOTS. PANEL IS ACTUALLLY 242UF.<[01] AFT WET AREA FLOOR PANEL 242UF WITH TOP SURFACE MULTIPLE FRAYED SPOTS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OSDR SWAA2023120815784Floor Panel · frayedAFT. WET AREA FLOOR PANEL 242D TOP SURFACE MULTIPLE FRAYED SPOTS.<[01] AFT WET AREA FLOOR PANEL 242D WITH TOP SURFACE MULTIPLE FRAYED SPOTS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] PANEL REPSDR SWAA2023120815783Floor Panel · frayedAFT. WET AREA FLOOR PANEL 241XF TOP SURFACE MULTIPLE FRAYED SPOTS.<[01] AFT. WET AREA FLOOR PANEL 241XF WITH TOP SURFACE MULTIPLE FRAYED SPOTS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.1.A DUE TO AMOUNT OF ALL DAMAGE.;[02] PANEL SDR SWAA2023120815791Floor Panel · frayedAFT. WET AREA FLOOR PANEL 241D TOP SURFACE MULTIPLE FRAYED SPOTS.<[01] AFT WET AREA FLOOR PANEL 241D WITH TOP SURFACE MULTIPLE FRAYED SPOTS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] PANEL REPSDR SWAA2023120815782Floor Panel · frayedFWD. WET AREA FLOOR PANEL 221FF TOP SURFACE MULTIPLE FRAYED SPOTS.<[01] FWD WET AREA FLOOR PANEL 221FF TOP SURFACE WITH MULTIPLE FRAYED SPOTS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] PANEL RSDR SWAA2023120815790Floor Panel · frayedFWD. WET AREA FLOOR PANEL 221EF TOP SURFACE MULTIPLE FRAYED SPOTS.<[01] REPAIRED WET AREA FLOOR PANEL 221EF IAW SRM 53-00-50-2R-1.;[02] VERIFIED CORRECTIVE ACTION ITEM 1. JOB COMPLETE.SDR SWAA2023120815542Floor Panel · frayedFWD. WET AREA FLOOR PANEL 222BF TOP SURFACE MULTIPLE FRAYED SPOTS.<[01] FRAYED SPOTS ON TOP SURFACE OF PANEL 222BF WAS REPAIRED IAW SRM 53-00-50-2R-1.;[02] VERIFIED CORRECTIVE ACTION ITEM 1. JOB COMPLETE.SDR SWAA2023120815541Floor Panel · frayedFWD. WET AREA FLOOR PANEL 222CF TOP SURFACE MULTIPLE FRAYED SPOTS.<[01] REPAIRED WET AREA FLOOR PANEL 222CF IAW SRM 53-00-50-2R-1;[02] VERIFIED CORRECTIVE ACTION ITEM 1. JOB COMPLETE.SDR SWAA2023120815540Floor Panel · frayedFWD. WET AREA FLOOR PANEL 222DF TOP SURFACE MULTIPLE FRAYED SPOTS.<[01] FWD WET AREA FLOOR PANEL 222DF WITH TOP SURFACE MULTIPLE FRAYED SPOTS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] PANEL RSDR SWAA2023120815539Floor Panel · frayedFWD. WET AREA FLOOR PANEL 222AF TOP SURFACE MULTIPLE FRAYED SPOTS<[01] FRAYED SPOTS ON TOP SURFACE OF FLOORBOARD 222AF WAS REPAIRED IAW SRM 53-00-50-2R-1.;[02] VERIFIED CORRECTIVE ACTION ITEM 1. JOB COMPLETE.SDR SWAA2023120815538Floor Panel · frayedFWD WET AREA FLOOR PANEL 221AF TOP SURFACE MULTIPLE FRAYED SPOTS<[01] FWD WET AREA FLOOR PANEL 221AF WITH TOP SURFACE HAVING MULTIPLE FRAYED SPOTS WAS REPAIRED PER SRM 53-00-50-2R-1.;[02] FINAL INSPECTION. JOB COMPLETE.SDR SWAA2023121115242Panel · delaminatedFAIRING PANEL 193CL HAS DELAMINATED PLIES ON INNER SURFACE FWD LEADING EDGE<[01] REPAIRED DELAMINATED PLIES ON INNER SURFACE FWD LEADING EDGE ON PANEL 193CL IAW SRM 51-70-05-2R-6;[02] FINAL INSPECTION. JOB COMPLETE.
Back to N8309C