N839EX
Service difficulty reports · 123
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N839EX' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N839EX' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HNAA2017052200177Bulb · burned outRED EMERGENCY LIGHT IN AISLE INOPERATIVE AT ROW 4 AND 2ND RED BULB AFT AT THAT LOCATION. R & R RED EMERGENCY LIGHT BULB AT ROW 4 AND 2ND RED BULB AFTSDR HNAA2017030600073Bulb · dimLOWER EMERGENCY PAX DOOR LIGHT IS DIM. REMOVED AND REPLACED THE BULBS. OPS CHECKED GOOD.SDR HNAA2016092100289Battery Pack · inoperativeTW0 MOST FORWARD FLOOR EMERGENCY LIGHTS ARE INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY AT ROW 3, RIGHT HAND CEILING LOCATION. OPS CHECKED GOOD.SDR HNAA2016082500258Indicator · malfunctionedWITH FLAPS OUT OF ZERO DETENT, LT RUDDER TRAVEL IS ONLY 10 DEGREES AND RT IS 16 DEGREES. R & R PFCS INDICATOR GROUND RAN ACFT, OPS CHECK GOOD IAW 27-05-00.SDR HNAA2016021700035Switch · malfunctionedLT ELEVATOR HORN HEAT CAUTION LIGHT ILLUMINATED WITH NO LOADS. SWAPPED ELEVATOR HORN HEAT SWITCH 3015-S4 AND 3015-S5 TO ALTERNATE POSITION. GROUND RAN ACFT WITH CREW. OPS CHECKED GOOD IAW SRT MANUAL.SDR HNAA2016011800011Bulb · inoperativeEMERGENCY OVERHEAD LIGHT IS INOPERATIVE. R & R BULBS IN OVERHEAD EMERGENCY LIGHT . OPS CHECKED GOOD.SDR HNAA2016011500006Inverter · odorFISH ODOR STRONG IN GALLEY AREA. R & R PRIMARY INVERTER IAW 24-22-00. OPS CHECKED GOOD.SDR HNAA2015120700363Bulb · inoperativeCABIN FLOOR EMERGENCY LIGHT IS INOPERATIVE, 6TH FROM FRONT. R & R BULBS FOR EMERGENCY LIGHT. OPS CHECKED GOOD.SDR HNAA2015120700360Wire · brokenEMERGENCY LIGHT IS INOPERATIVE AT ROW 8DF. REPAIRED EMERGENCY FLOOR PATH LIGHT WITH NEW WIRE SPLICE IAW MM 20-45-07. OPS CHECKED GOOD.SDR HNAA2015101600298Bulb · inoperativeFORWARD LT FUSELAGE EMERGENCY LIGHT IS INOPERATIVE. , R & R THE BULB. OPS CHECKED GOOD.SDR HNAA2015070800220O-Ring · damagedNR 1 HYDRAULIC ISOLATION VALVE CAUTION LIGHT ILLUMINATED, ROLL SPOILER INBD HYD CAUTION LIGHT CAME ON AND OFF SEVERAL TIMES, BUT EXTINGUISHED. HYDRAULIC PRESSURE WAS GOOD FOR THE FLIGHT, BUT QUANTITY WAS LOW. ALL OTHER INDICATIONS NORMAL. R & R O-RING ON PRSDR HNAA2015060300179Bulb · inoperativeROW 1 EMERGENCY FLOOR PATH LIGHT IS INOPERATIVE. R & R BULB AT ROW 1 EMERGENCY FLOOR PATH LIGHTS. OPS CHECKED GOOD.SDR HNAA2015022700064Bulb · burned outF/A EMERGENCY SWITCH LIGHT GREEN BULB INOPERATIVE ON F/A SWITCH PANEL ABOVE WARDROBE. REMOVED COVER LENS R & R BULB AND REINSTALLED COVER LENS.SDR HNAA2014120300340Warning Horn · false activationDURING TAKEOFF ROLL, TAKEOFF WARNING HORN SOUNDED. RETURNED TO GATE. RAN ACFT IN PROPER CONFIGURATION AND NO DISCREPANCIES NOTED.SDR HNAA2014092400274Bulb · failedEMERGENCY EXIT SIGN ON FLOOR BESIDE PASSENGER DOOR IS DIM. R & R BULB. OPS CHECKED GOOD.SDR HNAA2014081100227Line · leakingHYDRAULIC LEAK IN NOSE WHEEL WELL. INSTALLED NLG DRAG STRUT ACTUATOR BLUE FLEX LINE. CYCLED GEAR. NO LEAKS NOTED. CHECKED GOOD.SDR HNAA2014060200169Contactor · burnedAPU FAIL LIGHT ILLUMINATED DURING START. AUX AND MAIN CIRCUIT BREAKERS TRIPPED. SMOKE, FIRED BOTTLE. FOUND APU START CONTACTOR WELDED. COLLARED CIRCUIT BREAKER. R & R APU START CONTACTOR AND SMALL CABLE ASSY, EGT, SWAP HARNESS IAW BULLETIN 49-8. OPS CHECSDR HNAA2014041600132Transceiver · malfunctionedWEATHER RADAR NOT PAINTING CORRECTLY. R & R RADAR TRANSCEIVER IAW MM 34-41-04 AND BULLETIN 34-18. OPS CHECKED GOOD. OK FOR SERVICE.SDR HNAA2014040200117Bulb · inoperativeFORWARD EMERGENCY FLOOR PATH LIGHT IS INOPERATIVE AT ROW 1DF. R & R BULBS AT EMERGENCY FLOOR PATH LIGHT IN ROW 1DF. OPS CHECKED GOOD.SDR HNAA2013121600616Brush Block · dirtyNR 1 AC GENERATOR CAUTION LIGHT ILLUMINATED ON TAKEOFF RUN. CREW ABORTED TAKEOFF. CYCLED NR 1 AC GENERATOR SWITCH IAW CHECKLIST. CAUTION LIGHT EXTINGUISHED. OPS NORMAL. R & R NR 1 BRUSH BLOCK ASSEMBLY AND CLEANED BRUSH BLOCK CONNECTOR. SEATED CONNECTOR. GROSDR HNAA2013120600599Generator · malfunctionedAFTER DEPARTURE, NR 1 AC GENERATOR CAUTION LIGHT ILLUMINATED AND WILL NOT RESET. R & R NR 1 AC GENERATOR AND NR 1 AC GCU IAW WC 24-20-11R. GROUND RAN AIRCRAFT. OPS CHECKED GOOF AT THIS TIME. OK FOR SERVICE.SDR HNAA2013082200471Socket · overheatedHOT ELECTRICAL ODOR OVER ROW 4. INSPECTED AND FOUND OVERHEAD LIGHT 3DF OVERHEATING AT SOCKET AND BASE. REMOVED BULB, PULLED AND COLLARED CIRCUIT BREAKERS S1, S2 AND R2. CABIN INTERIOR NORMAL LIGHTING SYS, R & R SOCKET AT LAMP ASSY ON ROW 3DF. OPS CHECKED GSDR HNAA2013071000407Windshield · failedSMOKE COMING FROM TOP OD F/O'S WINDSHIELD IN WARM UP MODE. CREW TURNED OFF WINDSHIELD HEAT AND SMOKE DISSIPATED. R & R F/O'S WINDSHIELD IAW WC 56-00-00R. OPS CHECKED GOOD.SDR HNAA2013071000406Contactor · failedAPU FAILED. CIRCUIT BREAKER N-8 TRIPPED. R & R APU START CONTACTOR. RESET CIRCUIT BREAKER N-8. OPS CHECKED GOOD.SDR HNAA2013070900402Windshield · burnedSMOKE COMING FROM TOP OF F/O WINDSHIELD IN WARM UP MODE. CREW TURNED OFF WINDSHIELD HEAT SMOKE DISSIPATED. R & R F/O WINDSHIELD IAW W/C 56-00-00R. OPS CHECKED GOOD.SDR HNAA2013070900401Contactor · shortedAPU FAILED AUX CIRCUIT BREAKER N-8 TRIPPED. MX INSPECTED FIRE BOTTLE STILL CHARGED. NO OBVIOUS DEFECTS OR DAMAGE NOTED. R & R APU START CONTACTOR, RESET CIRCUIT BREAKER N8. OPS CHECKED GOOD. FOUND CONTACTOR SHORTED.SDR HNAA2013070100386Stiffener · crackedRIGHT VERTICAL STIFFENER IS CRACKED AT UPPER MOST RIVET. REPAIRED IAW RD8-53-7275 AND EO8-53-13-0416.SDR HNAA2013070100385Firewall · chafedNR 2 ENGINE FIREWALL IS CHAFED ON OTBD SIDE. REPAIRED NR 2 NACELLE FIREWALL IAW RD8-54-991.SDR HNAA2013070100384Seat Track · corrodedSEAT TRACK SECTION AT LAV AND GALLEY AREA ARE CORRODED. R & R SPLICED SECTION OF SEAT TRACK AT LAV AND GALLEY AREA IAW RD8-53-3074.SDR HNAA2013070100383Bolt · misinstalledIMPROPER JO-BOLT INSTALLATION IN COCKPIT BELOW LT WINDSCREEN SIDE POST AT WINDSCREEN DRAIN LINE. REMOVED JO-BOLT. PERFORMED HFEC INSPECTION. NO DEFECTS NOTED REPAIRED MISDRILLED FASTENER HOLE IAW RD8-53-13-4.SDR HNAA2013070100382Connector · unsecureNR 2 AC GENERATOR CAUTION LIGHT CAME ON DURING CLIMB OUT, CREW PERFORMED CHECKLIST AN TURNED GENERATOR OFF. ACFT RETURNED TO DEPARTURE. FOUND CONNECTOR PLUG ON GENERATOR LOOSE. RESECURED CONNECTOR PLUG. GROUND AIRCRAFT. OPS CHECKED GOOD.SDR HNAA2013070100381Spoiler Sys · out of rigRIGHT HAND INBOARD ROLL SPOILER DOES NOT INDICATE STOWED PRIOR TO TAKEOFF. REMOVED FLAP WELL PANELS 632BB,CB DB ON RT WING, R & R RT INBD FLIGHT SPOILER IAW MM 27-14-06. RIGGED AND OPS CHECKED GOOD IAW MM 27-14-00. REINSTALLED ALL FLAP WELL PANELS.SDR HNAA2013062800376Plate · cracked2.5" LONG CRACK AT CORNER OF LADDER PLATE FOR PANEL 522AT AT STA YW139.000, AFT OTBD CORNER. REPAIRED CRACK AT CORNER OF LADDER PLATED FOR PANEL 522AT AT STA YW139.000 IAW EO8-57-13-0398.SDR HNAA2013062800375Plate · cracked1" LONG CRACK AT FWD INBD CORNER OF STRESS PANEL 522AT LADDER PLATE. REPAIRED CRACK AT FWD INBD CORNER OF LADDER PLATE AT STRESS PANEL 522AT IAW EO8-57-13-0394A.SDR HNAA2013062800374Plate · crackedLADDER PLATE UNDER STRESS PANEL 622AT IS CRACKED AT THE FWD INBD CORNER. REPAIRED LADDER PLATE UNDER STRESS PANEL 622AT AT FWD INBD CORNER IAW EO8-57-13-039.SDR HNAA2013062400356Lamp · burned outMOST AFT CENTER EMERGENCY CEILING LIGHT IS INOPERATIVE. R & R BULB IN MOST AFT CENTER EMERGENCY CEILING LIGHT.SDR HNAA2013053100317Seat Track · corrodedCORROSION AT LT INBD SEAT TRACK BETWEEN BS 222 AND 242 UNDER WATER DRAIN DRIP TRAY. CUT SEAT TRAC IAW RD8-53-3074. SECURED WITH NEW SECTION OF SEAT TRACK ASSEMBLED AND INSTALLED FASTENERS IAW RD8-53-3074.SDR HNAA2013053100316Threshold · corrodedAIRSTAIR DOOR THRESHOLD IS CORRODED AROUND MOUNTING SCREW HOLES. R & R THRESHOLD IAW DWG 85321241.SDR HNAA2013051000264Structure · chafedINBD ZEE MEMBER CHAFED ON NR 1 NACELLE. REPAIRED FIREWALL ZEE MEMBER IAW EO 8-54-13-0268.SDR HNAA2013051000263Angle · crackedFIREWALL ANGLE CRACKED IN NR 1 NACELLE ABOVE JET PIPE. R & R FIREWALL ANGLE IAW DWG NR 85410024.SDR HNAA2013021900081Bulb · weakSIDE WALL EMERGENCY EXIT SIGN IS DIM AT PAX DOOR. R & R BULBS IN SIDE WALL EMERGENCY EXIT SIGN. OPS CHECKED GOOD.SDR HNAA2013011400006Line · rupturedNR 2 HYD QTY AT .5 WITH FLUID LEAKING IN NR 2 NACELLE WITH RUDDER ISOLATION VALVE CAUTION LIGHT ILLUMINATED. INSPECTED NR 2 WHEEL WELL AND FOUND HYD LINE FOR AFT GEAR DOOR FROM ELECTRIC SEQUENCE VALVE ACTUATOR RUPTURED. INSTALLED TEMP FLEX LINE IAW SP20.1 SSDR HNAA201301100004Light · failedFLOOR EMERGENCY LIGHT IS INOPERATIVE AT ROW 7. R & R LIGHT ASSY IAW MM 33-52-00. OPS CHECKED GOOD.SDR HNAA2013010900001Inverter · failedOILY BURNING SMELL AROUND FORWARD CABIN AREA AND FLIGHT DECK. FOUND AUX INVERTER FAILED. R & R AUX INVERTER. OPS CHECKED GOOD.SDR HNAA2012112901078Control Box · malfunctionedEMERGENCY LIGHTS FLICKERED ENROUTE. R & R EMERGENCY LIGHT CONTROL BOX IAW 61-10-11. OPS CHECKED GOOD. EMERGENCY LIGHTS DID NOT ILLUMINATED.SDR HNAA2012112901079Brush Block · inoperativeR & R NR 2 PROP BRUSH BLOCK IAW 61-10-11. OPS CHECKED GOOD.SDR HNAA2012112601071Brush Block · failedIN FLIGHT, RT AC BUSS CAUTION LIGHT ILLUMINATED WITH FAILURE OF ASSOCIATED SYS. REMOVED NR 2 PROP BRUSH BLOCK ASSY IAW AMM 61-10-11. OPS CHECKED SLIP RINGS ON NR 2 PROP IAW AMM 61-10-00. GROUND RAN ACFT. OPS CHECKED GOOD.SDR HNAA2012111401043Unknown · malfunctionedON CLIMBOUT, RT AC BUSS, RT STALL WARNING, RT TRU AND ELEVATOR HORN HEAT CAUTION LIGHTS ILLUMINATED. CLEANED CONNECTOR PLUGS AT NR 2 AC GEN. R & R NR 2 AC GCU. OPS CHECKED GOOD IAW MM 24-21-00. OK FOR SERVICE. ON CLIMB OUT, RT AC BUSS, RT STALL WARNING, RTSDR HNAA2012111201039Brush Block · dirtyON CLIMB OUT, EMERGENCY LIGHTS FLICKERED MOMENTARILY. OPS NORMAL AT THIS TIME. INSPECTED AND CLEANED BRUSH BLOCK AND CONNECTOR PLUGS. GROUND RAN ACFT. PROPELLER HEAT AND EMERGENCY LIGHTS OPS CHECKED GOOD AT THIS TIME. OK FOR SERVICE.SDR HNAA2012110501034Warning Light · illuminatedRT AC BUSS C/L ILLUMINATED INFLIGHT. WITH ASSOCIATED C/L. CONFIRMED OK WITH RT TRU DISABLED.
Back to N839EX