N844UA
Service difficulty reports · 98
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N844UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N844UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2014060991229Angle · crackedNR 2 PYLON HAS A CRACKED ANGLE OTBD SIDE NEAR RIB 6. CUT OUT CRACKED SPAR OTBD SIDE NEAR RIB 6 IAW SRM 54-52-12 FIG 211 SH 2. FABRICATED REPAIR SPLICE & INSTALLED SPLICE REPAIR IAW SRM 54-52-12. THIS REPAIR DOES NOT REQUIRE SRI INSPECTIONS IAW ABOVE SRM.SDR CALA2014060291184Stringer · corrodedAFT PIT HAS CORROSION LOCATED AT FRAME 61 - 64 STRINGER 41. R & R STRINGER LOCATED AT FRAME 61 - 64 STRINGER 41R PN D53476433200 IAW SRM 51-72-11. NO FURTHER ACTION REQUIRED.SDR CALA2014060291183Door Sill · corrodedAFT CABIN R2 DOOR SILL HAS CORROSION FRAME 66 - 68, STRINGER 23R - 23R. R & R R2 DOOR SILL PN 5348004320701 & PN D5348004220701 IAW SRM 51-72-11. NO ADDITIONAL ACTIONS REQUIRED.SDR CALA2014060291182Lug · gougedLT FWD PIT DOOR LATCH FITTINGS NR 2 FWD & AFT LUG & NR 3 FWD LUG WERE GOUGED ON THE RADIUS EDGE IN ZONE A. LUGS REWORKED IAW SRM 53-26-00 PAR 4 A. REMAINING MATERIAL THICKNESS IS FTG NR 2 FWD LUG 0.471 INCHES, AFT LUG 0.483 INCHES & FTG NT 3 FWD LUG 0.478 INSDR CALA2014031090558Wire Harness · brokenFOUND ON 2 SERVICE, EMERGENCY EXIT LIGHT IN SEAT ARMREST SIDE PANEL AT 31C IS OUT. FOUND HARNESS BROKEN AT CONNECTOR.SDR CALA2013122793981Connector · shortedLGCIU FAULT, MULTIPLE PROBLEMS AFTER. FOUND 23GA SENSOR CONNECTOR ON LT GEAR SHORTED. REPLACED CONNECTOR, CHECKED GOOD IAW TSM 32- 31-00-810-814-A. MESSAGE CLEARED & BITE CHECKED GOOD.SDR CALA2013120593486Nose Cowl · delaminatedFOUND LARGE AREA OF DELAMINATION ON ENG 1 INLET COWL PANEL DURING WALK AROUND INSPECTION. THE FOLLOWING DIMENSIONS APPLY FOR DAMAGED AREAS, BETWEEN 6 & 7 O'CLOCK 20" X16", DELAMINATION BETWEEN 7 & 8 O'CLOCK 11" X 12", DELAMINATION BETWEEN 8 & 9 O'CLOCK 10" X SDR CALA2013111292873Battery · faultyEPSU EMERGENCY AFT LEFT DISPLAYED AFTER EMERGENCY LIGHT TEST. INSTALLED NEW EPSU BATTERY POS LEFT AFT, OPERATIONS TESTED NORMAL.SDR CALA2013111292853Hook · faultyR2 DOOR HANDLE WILL NOT LOCK IN THE OPEN POSITION WHEN THE DOOR IS OPEN. REMOVED THE DOOR GEARBOX, REPLACED THE HOOK & REINSTALLED IAW AMN. OPERATIONS CHECKED OK.SDR CALA2013093091564Liner · damagedREPAIRED AREA OF RT ENGINE ACOUSTIC LINER HAS GASPER REPAIR FAILURE. LCL MX REPORTED FAN CASE ATTRITION LINER APPROXIMATELY 9"0 CLK ON ENGINE 2, MISSING MATERIAL APPROXIMATELY 1.5 INCH BY 0.5 INCH, WITHIN CARRY FORWARD LIMITS OF AMM MT72-017. TO BE REPAIRED SDR CALA2013082090602Battery Pack · faultyEPSU BITE FAULTS BATTERY EMERGENCY LEFT. REPLACED BATTERY PACK LEFT OVERWING LOWER SIDEWALL, CHECKED GOOD.SDR UALA2013070204618Light · unsecureNOSE TAKEOFF LIGHT HANGING FROM WIRES. SEAL MISSING, CAUSING LAMP TO HANG DOWN. REPLACED ASSY IAW AMM.SDR UALA2013070104567Sliding Window · delaminatedL2 WINDOW HAS EXTENSIVE DELAMINATION. IMPAIRS VISIBILITY. R & R LT SLIDING WINDOW PANEL IAW MM 561211400002A UP TO STEP 4DL2.SDR UALA2013052303592Pedal · lack of lubeF/O RUDDER PEDALS FAILED TO SPRING FWD FROM THE EXTENDED POSITION WHEN LEVER PULLED. RUDDER PEDAL ADJUSTMENT IS SERVICEABLE BUT REQUIRES UPGRADE. F/O PEDALS MOVE SLOWER THAN EXPECTED TO THE RETRACTED POSITION. LUBED AND OPS CHECKED OK IAW AMM.SDR UALA2013040402210Tire · damagedNR 2 TIRE HAS A CHUNK MISSING ON SIDE OF TIRE. REMOVED AND REPLACED TIRE IAW MM.SDR UALA2012111906669Door · bindsCOCKPIT DOOR DIFFICULT TO CLOSE WHILE AIRBORNE EASY TO CLOSE ON GROUND. DOOR POSITION PER MT 52-018. LATCH OPS CHECKED GOOD.SDR UALA2012082004609Battery · faultyEMERGENCY LIGHT TEST FAULTED THE LEFT OVER WING BATTERY. REPLACED LEFT OVERWING EMERGENCY BATTERY. OP CHECK NORMAL. BATTERY P/N IS AD-3224-30.SDR UALA2012032601930Interphone · inoperativeCAPTAIN'S OXYGEN MASK INTERPHONE NOT WORKING. REPLACED MASK ASSY, OPS CHECK NORMAL. REF MM 35-12-41-401.SDR UALA2012022001042Connector · disconnectedPER 3 SERVICE CHECK, CABIN EMERGENCY LIGHT TEST FAILED. EPSU BATTERY FWD LEFT AND EPSU COMM AFT LEFT. FOUND CONNECTOR DISCONNECTED AT ROW 22ABC, RECONNECTED CABIN EMERGENCY LIGHTS TESTED GOOD.SDR UALA2012012600552Wedge · dentedLT WING LT O/B FLAP T/E HAS LARGE DENT OTBD OF ENGINE. WEDGE IS REMOVED AND ROUTED TO SHOP 273, UNDER R29994. DAMAGE PRECISE LOCATION IS APPROX 20" OUTBOARD OF GAP SEAL ON TRAILING EDGE OF OUTBOARD FLAP, IN ZONE 2 AS IDENTIFIED IN FIGURE 101 OF SRM 57-53-00 SDR UALA2011120106615Microphone · inoperativeF/O'S OXYGEN MASK MICROPHONE IS INOPERATIVE. REPLACED FIRST OFFICERS FULL FACE MASK PER MM.SDR UALA2011110906114Liner · damagedNR 2 ENG INLET ATTRITION LINER HAS MISSING MATERIAL FROM PREVIOUS REPAIR AT 12 O'CLOCK. DAMAGE LESS THAN 20 PER, MUST BE REPAIRED WITHIN 20 CYC PER MT 72-017. RECOMMEND REPAIR BE DONE IN HANGER DUE TO EXTENT OF DAMAGE AREA, ATTRITION LINER MAY NEED TO BE REMSDR UALA2011080103958Idg · malfunctionedNR 1 GEN FELL OFFLINE, RTFL. NR 1 ENG IDG CHG'D, RUN ENG & CONFIRMED OPERATION OF NR 1 ENG IDG. RAN NR 1 ENG TO VERIFY NR 1 ENG IDG OPS, IDG. FREQ'S & VOLTS GOOD, HOWEVER NR 1 IDG DOES NOT PICK UP BUS AUTOMATICALLY.SDR UALA2011061702971Actuator · failedFUEL TRANSFER VALVES OPENED AFTER POWER CHANGE AFTER PLANE WAS FINISHED BEING FUELED. FOUND LEFT INNERCELL FUEL TRANSFER VALVE ACTUATOR (9QP) FAILED THE OPEN POSITION. REPLACED LEFT ACTUATOR 9QP.SDR UALA2011042902104Smoke Detector · faultyUPPER ECAM MSG: SMOKE LAV + CRG DET FAULT. ACPED MEL. LAV 1L INOP. NEXT MTC STA CONFIRM DOOR 1L LAV AT ISSUE AND UPDATE WITH POSS PARTS. REPLACED LAV SMOKE DETECTOR, OPS TEST NORMAL.SDR UALA2010121604597Skin · damagedFOUND 9 RIVETS WITH LIGHTENING STRIKE DAMAGE ON PANEL FWD OF WINDSHIELD LT SIDE. FRAMES 0 THROUGH 4, CL THROUGH Y-675. REPAIRED IAW ALL SRM AND DRAWINGS.SDR UALA2010040701161Smoke Detector · faultyLAV N CRG DET FAULTAND SCDU INOP HISTORY. TROUBLESHOOT REF MT26-002. ATTEMPT TO ID SPECIFIC SMOKE DETECTOR(S) FOR REPLACEMENT OR INOP SDCU CHANNEL. IF NO FAULTS ARE FOUND OR SPECIFIC ITEM(S) CAN NOT BE IDENTIFIED, REPLACE ALL LAV, CARGO SMOKE DETECTORS AND SDSDR UALA2010040601157Smoke Detector · faultyLAVATORY DET FAULT DISPLAYED ON UPPER ECAM SCREEN. LAV SMOKE DETECTOR FAULT ECAM. ACCOMPANYING CIDS CAUTION LIGHTS ILLUMINATED. ACCOMPLISH CHRONIC REVIEW. CIDS PANEL SHOWING LAV A 1WQ SMOKE DETECTION FAIL. LAV DEFERRED INOPERATIVE. REPLACED SMOKE DETECTOSDR UALA2009112503663Skin · damagedSEVERAL AREAS OF DAMAGE NOTED DURING LIGHTNING STRIKE INSPECTION. DAMAGE IS LOCATED ON FWD FUSE LT SIDE BETWEEN FRAMES 1 AND 4 JUST BELOW AIRCRAFT CENTERLINE. FOUND NUMEROUS RIVETS BURNED AND 1 STRIKE IN OPEN BAY. REPAIRED LIGHTNING STRIKES IN RVSM AREA OF SDR UALA2009090402779Oxygen System · defectiveCREW 02 CHECK. DUE TO REPETITIVE CREW 02 SERVICING WITH NO LEAKS ISOLATED ACCOMPLISH LEAK CHECK OF CREW 02 SYSTEM. REPLACED F/O 02 MASK BOX. FOUND TEST AND RESET SWITCH STUCK AND NOT WORKING. ALSO LEAKED CHECK LINES BELOW PILOT AND F/O 02 BOXES. NO LEAKS SDR UALA2009061801732Slide · crackedRAMP REPORTED CRACK IN RT OVERWING SLIDE PACK AT DEPARTURE TIME (APPROX 8 INCHES LONG). REPLACED OFF WING SLIDE.SDR UALA2009052901538Lever · frozenFOUND AFT RT MED AFT GIRT BAR FITTING SPRING LOADED LOCK LEVER FROZEN DOWN IN THE UNLOCKED POSITION. SLIDE WOULD HAVE BEEN NOT LOCKING. CLEANED AND LUBED LEVER. OP CHECKED GOOD. WORK ACCOMPLISHED ON WRITE UP J4412D.SDR 2008UALA04153Oxygen System · lowCREW OXYGEN SYSTEM LOW. RECORD PRESSURE PRIOR TO SERVICING. SERVICED TO 1840 PSI. OKAY FOR SERVICE.SDR 2008UALA00163Proximity Sensor · intermittentTHREE RED WITH NO ECAM ON FINAL. GEAR NOT DOWN RECYCLE OK GEAR DOWN. PROX SENSOR INTERMITTENT (38GA). REPLACED PROX SENSOR 38GA, PERFORMED GEAR SWINGS, ALL NORMAL, NO REPEATS.SDR 2008UALA00077Smoke Detector · malfunctionedCARGO SMOKE DETECTOR FAILS TO TEST. FAILS LOOP-A FWD PIT. ALSO HAD CIDS LAV SMOKE DET FAIL MSG. RESET C/B'S FOR SDCU (C6 AND T18) AND PERFORMED CARGO SMOKE DET TEST. ALL PASSED AND ALL MESSAGES CLEARED AFTER RESET. NO REPEATS SINCE ORIGINAL.SDR 2007UALA04535Seat Track · wornLT INBD AND OTBD AND RT INBD AND OTBD OVERWING SEAT TRACKS ARE WORN OUT OF LIMITS FROM WHERE FWD SEAT LUGS LOCK INTO TRACKS BETWEEN FRAMES 41 AND 47 MAJOR REPAIR ACCOMPLISHED. DURING HMV VISIT.
SDR 2007UALA02956Oxygen Mask · faultyF/O OXYGEN MASK DOES NOT FULLY INFLATE. SHOP FINDINGS INDICATE A CRACKED MAIN CASE WHICH WILL ALLOW LEAKAGE TO OCCUR. MASK REMOVED AND SENT TO SHOP FOR COMPLETE OVERHAUL. NEW MASK INSTALLED ON A/C.SDR 2007UALA02734Steering Sys · failedNOSE WHEEL STEERING FAILED ON TAXI OUT. FOUND SERVO 6GC FAILURE. REPLACED SERVO 6GC. OPS CHECK GOOD.SDR 2007UALA02634Unknown · odorFLIGHT ATTENDANT REPORTING ELECTRICAL ODOR AROUND ROW 20, COOLED DOWN THE TEMP AND SHUT OFF LIGHTS AND ODOR IS DISSIPATING. INSPECTION DONE OF AREA, TURNING OFF AND ON LIGHTS AND AIR. NO ODORS NOTED. NO REPEATS SINCE ORIGINAL.SDR 2007UALA02453Sensor · malfunctionedNO NOSE WHEEL STEERING ON TAXI OUT. PROXIMITY SENSOR 28GA FAILURE. REPLACED PROXIMITY SENSOR 28GA.SDR 2007UALA00904Battery · inoperativeEMERGENCY LIGHTS INOPERATIVE AT SEAT ROWS 8, 9 AND 10. [SUP 4-17-07] REPLACED PSEU AND BATTERY ON RT SIDE AT SEATS 9 AND 10. OPS CKD EMERGENCY LITE SYSTEM. CKD OK AND REPLACED EMERGENCY LIGHT CABLE AT SEAT 8 ABC LIGHT.SDR 2007UALA00723Power Supply · no testRIGHT OVERWING FAILS EMERGENCY LIGHT TEST. REPLACED POWER SUPPLY AND BATTERY.SDR 2006UALA01581Light · faultyEMERGENCY SYSTEM WILL NOT TEST. CIDS PANEL GIVES -TEST ABORTED. NO COMM-. RESET CIDS SYSTEM 4 TIMES AND REPOWERED A-C 3 TIMES, ALL NO HELP. RESEATED CIDS CARDS, EMERGENCY SYSTEM TEST PASSED.SDR 2006UALA00476Connector · disconnectedEMERGENCY LIGHT CHECK FAILS -EPSU EXT LOAD FWD L-. PERFORMED TROUBLE SHOOTING. FOUND DOOR 2R SLIDE BATTERY CONNECTOR DISCONNECTED. SECURED AND PERFORMED TEST, TESTED OK.SDR 2006UALA00415Bottle · dischargedSLIDE DOOR 1R BOTTLE PRESSURE LOW. REPLACED DOOR 1R SLIDE.SDR 2005UALA01303Slide · lowDOOR SLIDE PRESSURE LOW AT DOOR 1L. SLIDE PACK ASSY FELL APART IN CONTAINER. MR TIME DATED 20SEP2005 SHOWED THAT ACFT-4044 HAD MR25611-109 INSTALLED ON 1L. MR25611-109 HAD BEEN SCHEDULED TO BE REMOVED DUE TO TIME ON 19NOV2005. MRTIME DATED 28NOV2005 AND 23DESDR 2005UALA00594Door · openPILOTS REPORTED LT OVERWING DOOR OPEN ECAM MESSAGE. LATCH COVER (PLASTIC PART) FELL OFF IN FLIGHT (REMOVED?). PART SHOULD HAVE BEEN REINSTALLED AND WARNING WOULD HAVE GONE OUT. COVER HAS PROXIMITY SWITCH TO ENSURE CLOSED. THIS PROXIMITY SWITCH, IN ADDITIONSDR 2003UALA00986Lens · missingFIRST CLASS CLOSET EEL LIGHT IS MISSING LENS ASSY. REPLACED LIGHT ASSY.