N8644C
Service difficulty reports · 156
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N8644C' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N8644C' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2026082090493Light · out of limitsFSD EXIT LIGHT INDICATOR NOT PER CONFIGURATION REMOVED AND REPLACED FSD EMERGENCY EXIT LIGHT TO A/C CONFIGURATION IAW AMM 33-51-01-960-802 AMM 33-51-00-710-801 AMM 33-51-00-720-801. INSTALLED EMERGENCY EXIT LIGHT ASSEMBLY P/N: 702409DME-1007. ALL OPERATIONALSDR SWAA2026082514389Battery Pack · inoperativeALL EMERGENCY LIGHTS ASSOCIATED WITH BATTERY PACK M1694 INOPERATIVE. R & R THE BATTERY PACK, PERFORMED A GOOD OPS TEST IAW AMM 33-51-06-960-805.SDR SWAA2026082572025Support Angle · corrodedCORROSION FOUND ON FWD CARGO BAY AFT BULKHEAD SUPPORT ANGLE, BS 500I, LBL 31, WL 163. R & R THE BULKHEAD SUPPORT ANGLE, BS 500I, LBL 25 - 45, WL 163 IAW SRM 51-40-02, & DWG 143A9481, REV -.SDR SWAA2026082591219Scuff Plate · crackedFORWARD CARGO BAY AFT CORNER SCUFF PLATE CRACKED. R & R THE AFT CORNER SCUFF PLATE IAW SRM 51-40-02,SDR SWAA2026082541242Baffle · crackedBAFFLE FROM BS 500D - 500E, RBL 25 WAS CRACKED. R & R THE RT FCB BAFFLE BS 500D - 500E, RBL 25, WL 156 IAW SRM 51-40-02, & DWG 143A7505 REV -.SDR SWAA2026082081258Elevator · unbalancedBALANCE LT ELEVATOR AND TAB AFTER PAINT. BALANCED LT ELEVATOR IAW SRM 51-61-04-0G-0, & EA M-22-155-03766 .SDR SWAA2026082549898Handle · crackedFWD LT OVERWING EMERGENCY EXIT DOOR, FOUND GRIP ASSY ACCESS CRACKED, R & R A NEW FWD LT OVERWING EMERGENCY EXIT DOOR GRIP ASSY ACCESS IAW AMM 52-22-51-000-801, STEP 2.C.(1).(B), AMM 52-22-51-400-801, STEP 3.D.(2).(D), & AIPC 52-22-51-02A.SDR SWAA2026082577344Web · crackedFWD CARGO BAY FLOOR SUPPORT CRACKED BTWN BS 440 - 460, LBL 25, WL 156. R & R LT FLOOR SUPPORT IAW SRM 51-40-02, & DWG 143A7505, REV -.SDR SWAA2026082589157Frame · crackedBS 312 FRAME UPPER ANGLE CRACKED AT LBL 33 BETWEEN S5L & S6L., PERFORMED EA M-22-153-01244 IN CC TTG8Q01DDXQX.SDR SWAA2026082570278Handle · damagedFORWARD ENTRY DOOR UPPER ASSIST HANDLE LINING DAMAGED. R & R WITH A SERVICEABLE FWD ENTRY DOOR UPPER ASSIST HANDLE LINING IAW AMM 52-11-31-000-802, STEP 2.F.(3), & AMM 52-11-31-400-802, STEP 3.G.(2).SDR SWAA2026082529749Sidewall Support · corrodedCORROSION ON LT FLOOR TO SIDEWALL SUPPORT FROM BS 787 - 727D, WL 162.64. R & R THE SIDEWALL SUPPORT IAW SRM 51-40-02-0G-0, & DWG 146A7500, REV -.SDR SWAA2026082565214Sidewall Support · corrodedCORROSION ON RT FLOOR TO SIDEWALL SUPPORT, BS 787 - 727D, WL 157.79. R & R WITH A NEW SIDEWALL SUPPORT IAW SRM 51-40-02-0G-0, AND DWG 146A7500, REV -.SDR SWAA2026082574208Scuff Plate · crackedFWD SERVICE DOOR SCUFF PLATE WAS CRACKED.SDR SWAA2026082591739Support Angle · corrodedCORROSION FOUND IN TWO FASTENER HOLES IN LT AFT CABIN FLOORBEAM, WL 208.1, BS 992.8, FROM LBL 37 - 43. R & R SUPPORT ANGLE IAW SRM 51-10-02, PARA 9.C.SDR SWAA2026082533026Floor Panel · pulledFLOOR PANEL 231YF UPPER SKIN HAS AREAS OF PULLED STRANDS. FABRICATED A NEW FLOOR PANEL. REPLACEMENT ACCOMPLISHED IAW SRM 53-00-50-2R-0.SDR SWAA2026082595278Floorbeam · corrodedCORROSION FOUND ON RT AFT CABIN FLOORBEAM ANGLE AT WL 208.1, BS 992.8, RBL 41. R & R THE FLOORBEAM ANGLE AT BS 992.8 RBL 37 - 43 IAW SRM 51-10-02, PARA 9.C.SDR SWAA2026082555230Floor Panel · pulledFWD FLOOR PANEL 221EF UPPER SKIN HAS AREAS OF PULLED STRANDS. THE FLOOR PANEL WAS REPLACED WITH A SERVICEABLE FLOOR PANEL IAW SRM 51-10-02-0G-0, PARA 9.A.1, DUE TO AMOUNT OF DAMAGE.SDR SWAA2026082594553Floorbeam · corrodedCORROSION FOUND IN ONE FASTENER HOLE IN THE AFT CABIN FLOORBEAM, WL 208.1, BS 986.5, LBL 43. THE FLOORBEAM FASTENER HOLE WAS REPAIRED IAW SRM 53-70-51-2R-6.SDR SWAA2026082594600Floorbeam · corrodedCORROSION FOUND ON RT AFT FLOORBEAM AT WL 208.1, BS 947, RBL 52. PERFORMED A REPAIR ON THE FLOORBEAM IAW SRM 53-70-51-2R-5, REPAIR 5.SDR SWAA2026082574640Intercostal · crackedFWD CARGO BAY INTERCOSTAL ANGLE CRACKED AT STR 25R, FWD SIDE OF BS 500G WL 156. R & R THE INTERCOSTAL ANGLE IAW SRM 51-40-02, & DWG 143A7505, REV -.SDR SWAA2026082596920Intercostal · crackedFWD CARGO BAY INTERCOSTAL ANGLE CRACKED AT STR 25L, FWD SIDE OF BS 500H. R & R THE INTERCOSTAL ANGLE, FWD SIDE OF FS500H LBL25 WL156 IAW SRM 51-40-02 DWG: 143A7505 ID:0137 REV: - VERIFIED ITEM 1SDR SWAA2026082534542Floor Panel · pulledFLOOR PANEL 231EF, UPPER SKIN HAS AREAS OF PULLED STRANDS. THE FLOOR PANEL WAS REPLACED WITH A SERVICEABLE FLOOR PANEL IAW SRM 51-10-02-0G-0, PARA 9.A.1, DUE TO AMOUNT OF DAMAGE.SDR SWAA2026082561590Floor Panel · pulledFLOOR PANEL 231XF UPPER SKIN HAS AREAS OF PULLED STRANDS. REPLACED THE FLOOR PANEL IAW SRM 51-10-02-0G-0, PARA 9, & AIPC 53-21-00-42A, ITEM 165.SDR SWAA2026082547147Floor Panel · pulledFLOOR PANEL 231DF, UPPER SKIN HAS AREAS OF PULLED STRANDS. THE FLOOR PANEL WAS REPLACED WITH A SERVICEABLE FLOOR PANEL IAW SRM 51-10-02-0G-0, PARA 9.A.1, DUE TO AMOUNT OF DAMAGE.SDR SWAA2026082546027Sidewall Support · corrodedCORROSION FOUND ALONG RT SIDE OF FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT, WL 156, BS 500A+7 - 500D+2. R & R THE SIDEWALL SUPPORT BTWN BS 500A TO BS 500I IAW SRM 51-40-02, & DWG 143A7500 REV -.SDR SWAA2026082525793Floor Panel · pulledFLOOR PANEL 231FF UPPER SKIN HAS AREAS OF PULLED STRANDS. THE FLOOR PANEL WAS REPLACED WITH A SERVICEABLE FLOOR PANEL IAW SRM 51-10-02-0G-0, PARA 9.A.1. DUE TO AMOUNT OF DAMAGE.SDR SWAA2026082593458Floor Panel · pulledFLOOR PANEL 242CF UPPER SKIN HAS AREAS OF PULLED STRANDS. THE FLOOR PANEL WAS REPLACED WITH A SERVICEABLE FLOOR PANEL IAW SRM 51-10-02-0G-0, PARA 9.A.1. DUE TO AMOUNT OF DAMAGE.SDR SWAA2026082534550Shield · corrodedCORROSION FOUND ALONG RT FWD CARGO BAY, AFT SHIELD AT WL 156, BS 500+2 - 500+14. R & R THE SHIELD BTWN BS 492 - 500A, RBL 25, WL 156 IAW SRM 51-40-02, & DWG 143A0080 REV -.SDR SWAA2026082514695Intercostal · crackedFWD CARGO BAY INTERCOSTAL ANGLE CRACKED AT STR 25R AFT SIDE OF BS 440 WL 156. R & R THE INTERCOASTAL ANGLE IAW SRM 51-40-02 & DWG 143A7505, REV -.SDR SWAA2026082573350Floor Panel · pulledFWD FLOOR PANEL 221GF UPPER SKIN HAS AREAS OF PULLED STRANDS. THE FLOOR PANEL WAS REPLACED WITH A SERVICEABLE FLOOR PANEL IAW SRM 51-10-02-0G-0, PARA 9.A.1. DUE TO AMOUNT OF DAMAGE.SDR SWAA2026082555707Intercostal · crackedFWD CARGO BAY INTERCOASTAL ANGLE CRACKED AT STR 25R FWD SIDE OF BS 500F. R & R THE INTERCOSTAL ANGLE IAW SRM 51-40-02, & DWG 143A7505, REV -.SDR SWAA2026082574525Attach Angle · crackedCRACKED COMPOSITE BULKHEAD ATTACH ANGLE AT BS 663, RBL 35, WL 166. R & R THE UPPER ATTACH ANGLE BS 663, RBL 6 - 63, WL 166 IAW SRM 51-40-02, & DWG 111A1000 REV -.SDR SWAA2026082513775Support · corrodedCORROSION FOUND ALONG FWD CARGO BAY, END WALL SUPPORT AT WL 156, RBL 25, BS 500I. R & R THE RT BULKHEAD SUPPORT ANGLE IAW SRM 51-40-02, & DWG 143A9481, REV -.SDR SWAA2026082513307Floor Panel · pulledFLOOR PANEL 242AF UPPER SKIN HAD AREAS OF PULLED STRANDS. FABRICATED A NEW FLOOR PANEL, REPLACEMENT ACCOMPLISHED IAW SRM 53-00-50-2R-0.SDR SWAA2026082514145Floor Support · corrodedCORROSION FOUND ON LT FLOOR SUPPORT, BS 947+2, LBL 52, WL 208. R & R FLOOR SUPPORT BTWN BS 947 - 967, LBL 52, WL 208 IAW SRM 51-40-02, & DWG 147A5650, REV A.SDR SWAA2026082573053Intercostal · crackedFCB INTERCOSTAL WEB CRACKED IN TWO PLACES AT STR 25L, BTWN BS 500 - 500A, WL 156. R & R THE INTERCOSTAL WEB IAW SRM 51-40-02, & DWG 143A7505 REV -.SDR SWAA2026082556444Floor Panel · pulledFLOOR PANEL 231GF UPPER SKIN HAS AREAS OF PULLED STRANDS. THE FLOOR PANEL WAS REPLACED WITH A SERVICEABLE FLOOR PANEL IAW SRM 51-10-02-0G-0, PARA 9.A.1, DUE TO AMOUNT OF DAMAGE.SDR SWAA2026082591911Floor Panel · pulledFWD FLOOR PANEL 231AF UPPER SKIN HAS AREAS OF PULLED STRANDS. THE FLOOR PANEL WAS REPLACED WITH A SERVICEABLE FLOOR PANEL IAW SRM 51-10-02-0G-0, PARA 9.A.1, DUE TO AMOUNT OF DAMAGE.SDR SWAA2026082593043Web · corrodedCORROSION ON AFT CARGO BAY SUB THRESHOLD WEB AT BS 796 - 842, RBL18 -28, WL 160. R & R THE SUB-THRESHOLD WEB IAW SRM 51-40-02-OG-0, AND DWG 146A8120, REV A.SDR SWAA2026082532311Sidewall Support · corrodedCORROSION FOUND ALONG LT SIDE OF FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT, WL 156, BS 500D+9 - 520. R & R THE FLOOR TO SIDEWALL SUPPORT, BS 396 - 500I & SPLICES, LBL 23, WL 153 IAW SRM 51-40-02, DWG 143A7501, REV -, SRM 53-00-53-2R-6, REPAIR 6, & TASK M-22-SDR SWAA2026082532496Support · corrodedCORROSION FOUND ALONG FWD CARGO BAY END WALL SUPPORT AT WL 156, RBL 18 - 19, BS 500I. REMOVED AND REPLACED BULKHEAD SUPPORT AT WL 156 RBL 18 -19, BS 500I IAW SRM 51-40-02 AND DWG 143A9481 REV -.SDR SWAA2026082589829Floor Panel · pulledFLOOR PANEL 242HF UPPER SKIN HAD AREAS OF PULLED STRANDS. FLOOR PANEL 242HF WAS REPLACED WITH A SERVICEABLE FLOOR PANEL IAW SRM 51-10-02-0G-0, PARA 9,.A.1. DUE TO AMOUNT OF DAMAGE.SDR SWAA2026082553413Floor Panel · pulledAFT FLOOR PANEL 242UF UPPER SKIN HAS AREAS OF PULLED STRANDS. REPLACED AFT FLOOR PANEL 242UF IAW SRM 51-10-02-0G-0, PARA 9, & AIPC 53-21-51-46, ITEM 250.SDR SWAA2026082512308Floor Panel · pulledFWD FLOOR PANEL 222DF UPPER SKIN HAS AREAS OF PULLED STRANDS. THE FLOOR PANEL WAS REPLACED WITH A SERVICEABLE FLOOR PANEL IAW SRM 51-10-02-0G-0, PARA 9.A.1.SDR SWAA2026082589679Floor Panel · pulledFLOOR PANEL 241BF UPPER SKIN HAS AREAS OF PULLED STRANDS. FABRICATION OF NEW 241BF FLOOR PANEL, REPLACEMENT WAS ACCOMPLISHED IAW SRM 53-00-50-2R-0.SDR SWAA2026082594075Floor Panel · pulledFLOOR PANEL 241GF UPPER SKIN HAS AREAS OF PULLED STRANDS. REPAIRED BY FABRICATING A NEW FLOOR PANEL IAW SRM 53-00-50-2R-0-B00275.SDR SWAA2026082589825Floor Panel · pulledFLOOR PANEL 231PF UPPER SKIN HAS AREAS OF PULLED STRANDS. THE FLOOR PANEL WAS REPLACED WITH A SERVICEABLE FLOOR PANEL IAW SRM 51-10-02-0G-0, PARA 9.A.1.SDR SWAA2026082531157Floor Panel · pulledFLOOR PANEL 241DF UPPER SKIN HAS AREAS OF PULLED STRANDS. THE FLOOR PANEL WAS REPLACED WITH A SERVICEABLE FLOOR PANEL IAW SRM 51-10-02-0G-0, PARA 9.A.1.SDR SWAA2026082510179Floorbeam · corrodedCORROSION FOUND IN FASTENER HOLES 10 EA ON AFT PAX CABIN FLOORBEAM, WL 208.1, BS 986.5, RBL 43. THE FLOORBEAM WAS REPAIRED IAW SRM 53-70-51-2R-6.SDR SWAA2026082588354Floor Panel · pulledFLOOR PANEL 231KF UPPER SKIN HAD AREAS OF PULLED STRANDS. THE FLOOR PANEL WAS REPLACED WITH A SERVICEABLE FLOOR PANEL IAW SRM 51-10-02-0G-0, PARA 9.A.1.
Back to N8644C