N878AS
Service difficulty reports · 227
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N878AS' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N878AS' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA2021072159640Support · cracked*LEFT HAND WING TO BODY FAIRING SUPPORT STRUCTURE ON INTERCOSTAL IS CRACKED JUST AFT OF FS473.15. (MARKED & FLAGGED) (C-CHECK RO 7/18/2021) INSTALLED NEW SUPPORT ANGLE REF. CRJ200 SRM 51-42-06, CRJ200 SRM 51-42-13, CRJ200 SRM 51-45-00 AND DWG 601R-31037SDR SWIA2021072159624Floorbeam · corroded*CRACKED ANGLE ON OUTBOARD SIDE OF THE FLOORT BEAM RBL9 FS484.00. (MARKED) (C-CHECK RO 7/18/2021) REMOVED AND REPLACED 1EA NEW CLIP P/N 601R31171-9 ON OUTBOARD SIDE OF THE FLOOR BEAM AT FS 484.00 AND RBL 9.00. REF DWG 601R31171 REV-A, MHI REO 601R-53-41SDR SWIA2021072159623Floorbeam · cracked*CRACKED ANGLE ON OUTBOARD SIDE OF THE FLOORT BEAM LBL9 FS461.00. (MARKED) (C-CHECK RO 7/18/2021) INSTALLED NEW FLOOR BEAM ANGLE AT F.S. 461.00 AND LBL9 IAW DWG 601R31118 REV L AND CRJ200 SRM 51-42-21. COMPLIED WITH ATTACHED TASK 51-900-1003-SKYSDR SWIA2021072159622Skin · dented*NINE PROTRUDING DENTS BETWEEN FS672.00 AND FS718.00 STGR21R €“ STGR25R WITH A SEGMENTED CREASE RUNNING THRU FS682.00 €“ FS718.00 STGR21R €“ STGR22R. ALL MARKED IN RED. (C-CHECK RO 7/18/2021) REPAIRED DENTED AREAS BETWEEN FS672 AND FS718 STR21R-25R. SDR SWIA2021072159621Structure · corroded*CORROSION AROUND TWO FASTENER HOLES RBL42 FS427.00 & FS478.00. (MARKED) (C-CHECK RO 7/18/2021) REMOVED/BLENDED CORROSION FROM AROUND FASTENERS HOLES. NO DEFECTS NOTED AND FOUND TO BE WITHIN LIMITS AND COMPLIED WITH ALL APPLICABLE STEPS OF REO 601R-53-4SDR SWIA2021072159620Structure · corroded*CORROSION AROUND FASTENER LBL36 FS424.00. (MARKED) (C-CHECK RO 7/18/2021) REPAIRED CORROSION AROUND FASTENER LBL36 FS424.00 REF REO 601R-53-41-666 REV C DATE 2012-11-06 C/W 51-900-1003-SKYSDR SWIA2021072159619Lintel · cracked*FS280 LINTEL STGR 3L IS CRACKED (C-CHECK RO 7/18/2021) REPAIRED FS280 STR3L LINTEL AREA PER REO 601R-53-21-3463 (REV --) DATED 2021-07-05 (ALL STEPS COMPLIED WITH). / COMPLETED SKYWEST TASK CARD 51-900-1003-SKY.SDR SWIA2021072159618Skin · dented*DENT ON EXTERNAL FUSELAGE SKIN BETWEEN FS 589.00 €“ 605.00, STGR 25R €“ 26R (C-CHECK RO 7/18/2021) REPAIRED DENT AT FS589 - 605, STR25R - 26R. REF REO 601R-53-61-7663 (REV --) DATED 2021-06-29. NO LEAKS NOTED / COMPLETED SKYWEST TASK CARD 51-900-1003SDR SWIA2021072159617Window Post · cracked* R/H WIINDSHIELD SIDE POST SUPPORT CRACKED. REPLACED RH WINDSHIELD SIDE POST SUPPORT BRACKET PER DWG 601R34032 (REV V) AND CRJ200SRM 51-42-06. / COMPLETED SKYWEST TASK CARD 51-900-1003-SKY.SDR SWIA2021072159671Drag Angle · cracked*PASSENGER DOOR €“ RED DOT ON THE INNER SKIN AT THE LOWER END OF THE DRAG ANGLE. REMOVE THE RED DOT AND EVALUATE THE CRACK IN THE DRAG ANGLE. (C-CHECK RO 7/18/2021) - INSTALLED NEW SPLICE ON THE PASSENGER DOOR AFT DRAG BEAM IAW REO 601R-52-11-513 REV -SDR SWIA2021072159616Bracket · cracked* R/H MLG WHEEL WELL HAS BRAKE PRESSURE TRANSDUCER MOUNTING BRACKET CRACKED. (C-CHECK RO 7/18/2021) REMOVED AND REPLACED RH MLG WHEEL WELL BRAKE PRESSURE TRANSDUCER BRACKET REF CRJ200 SRM 51-42-06, CRJ200 SRM 51-41-00 AND DWG 601R75261, REV-N. NO LEAKS.SDR SWIA202159615Bracket · cracked* L/H MLG WHEEL WELL HAS BRAKE PRESSURE TRANSDUCER MOUNTING BRACKET CRACKED. (C-CHECK RO 7/18/2021) REMOVED AND REPLACED LH MLG WHEEL WELL BRAKE PRESSURE TRANSDUCER BRACKET REF CRJ200 SRM 51-42-06, CRJ 200 SRM 51-41-00 AND DWG 601R75261, REV-N. NO LEAKSSDR SWIA202159614Intercostal · corroded*INTERCOSTAL CORRODED AT THE AFT END FS349.00 €“ FS364.00. (MARKED) (C-CHECK RO 7/18/2021) REMOVED AND REPLACED INTERCOSTAL AT FS349-FS364 BETWEEN STR27-STR26L. REF CRJ200 SRM 51-42-06 AND CRJ200 SRM 51-42-21 AND DWG 601R31049, REV-G. COMPLIED WITH ATTSDR SWIA2021072159670Bolt · corroded*KEEPER HARDWARE CORRODED FOR L/H OTBD HINGE-BOX ASSY. AT WS 174.00 (C-CHECK RO 7/18/2021) ORDERED AND RECIEVED NEW FROM STOCK KEEPR HARDWARE (3EA BOLTS AND WASHERS) FOR THE LH OTBD HINGE BOX ASSY AT WS 174.00. INSTALLATION ACCOMPLISHED ON JOB 2759080 SDR SWIA2021072159669Bolt · corroded*KEEPER HARDWARE CORRODED FOR L/H OTBD HINGE BOX ASSY AT WS 264.00 (C-CHECK RO 7/18/2021) ORDERED AND RECIEVED NEW FROM STOCK KEEPER HARDWARE (1EA BOLT AND WASHER) FOR LH OTBD FLAP HINGE BOX ASSY AT WS 264.00. INSTALLATION ACCOMPLISHED ON JOB 2759080 SDR SWIA202159668Hinge · corroded*L/H OTBD HINGBOX SPRING IS CORRODED AT WS 264.00 (MARKED) (C-CHECK RO 7/18/2021) REMOVED AND REPLACED L/H OTBD FLAP HINGE BOX SPRING AT WS 264.00 WITH A NEW HINGE BOX SPRING REF CRJ200 AMM 27-54-25-000-801 AND CRJ200 AMM 27-54-25-400-801.SDR SWIA2021072159667Plate · corrodedLEFT AILERON HINGE FITTING, MIDDLE FITTING AILERON PLATE HAS A CORRODED FASTENER (C-CHECK RO 7/18/2021) ORDERED AND RECIEVED WITH NEW FROM STOCK (1 BOLT) FOR LEFT AILERON HINGE FITTING, MIDDLE FITTING PLATE. INSTALLATION ACCOMPLISHED ON JOB: 2759081 OPSDR SWIA2021072159666Nut · corrodedLEFT AILERON HINGE FITTING, MIDDLE HINGES HAVE CORRODED CASTLE NUTS (2) (C-CHECK RO 7/18/2021) ORDERED AND RECIEVED NEW FROM STOCK (2EA) NUTS AND COTTER PINS FOR THE LH AILERON MIDDLE HINGE FITTING. INSTALLATION ACCOMPLISHED ON JOB 2759080 OP 518 MX TSDR SWIA2021072159665Nut · corrodedLEFT AILERON HINGE FITTING OUTBD HAS (2) CORRODED CASTLE NUTS. (C-CHECK RO 7/18/2021) ORDERED AND RECIEVED NEW FROM STOCK (2EA) NUTS, WASHERS AND COTTER PINS FOR THE LH AILERON OTBD HINGE FITTING. INSTALLATION ACCOMPLISHED ON JOB 2759080 OP 518 MX TRSDR SWIA2021072159613Skin · gouged* GOUGES AROUND SCREW HOLE AT 1 O'CLOCK POSITION IN EXTERNAL SKIN CUT-OUT FOR PANEL 132AL (MARKED) (C-CHECK RO 7/18/2021) REPAIRED GOUGE DAMAGE TO ACCESS PANEL DOOR SURROUND DOUBLER BETWEEN FS220.00-FS235.00 AND STR19R-STR20R REF REO 601R-53-11-3695, RSDR SWIA2021072159612Angle · corroded*SERVICE DOOR €“ ANGLE CORRODED. AFT BOTTOM STOP FITTING, AFT ANGLE INSIDE DOOR, IS CORRODED. (MARKED & FLAGGED) (C-CHECK RO 7/18/2021) REMOVED CORROSION IS OUT OF LIMITS, REMOVED AND WET INSTALLED NEW REPLACEMENT SERVICE DOOR ANGLE AFT BOTTOM STOP FISDR SWIA2021072159611Skin · corroded* UNDER AFT CARGO PLATE, MULTABLE AREA'S OF CORROSION ON ACFT SKIN. FLAGGED (C-CHECK RO 7/18/2021) BLENDED CORROSION FROM AFT CARGO PLATE, MULTIPLE AREAS OF CORROSION ON AFCT SKIN. REF REO 601R-53-61-7683, REV--, DATED 2021-06-28. FOUND TO BE WITHIN LISDR SWIA2021072159610Handle · chafed* AFT CARGO DOOR HANDLE SURROUND CHAFED (MARKED). (C-CHECK RO 7/18/2021) REMOVED AND REPLACED AFT CARGO DOOR HANDLE HOUSING REF DWG 601R35027, REV-AY AND CRJ200 SRM 51-42-21. NO LEAKS NOTED. SEE CONTINUE CARD FOR DETAILS. COMPLIED WITH TASK 51-900-1003-SDR SWIA2021072159609Skin · dentedADM# N878AS-5073 DENT #1 1.5" AFT OF FS605 AND 18" BELOW CARGO DOOR OPENING. DENT #2 3.75" AFT OF FS605 AND 15" BELOW CARGO DOOR OPENING. (C-CHECK RO 7/18/2021) HAND DRESSED DENT #1 1.5" AFT OF FS605 AND 18" BELOW CARGO DOOR OPENING. DENT #2 3.75" AFTSDR SWIA2021072159672Hinge · damagedREMOVE AND INSTALL RT WING OTBD FLAP HINGE BOX ASSY WS178.00, WS220.00 AND WS264.00 TO FOM PER AMM (C-CHECK RO 7/18/2021) REMOVED AND REINSTALLED RT WING OTBD FLAP HINGE BOX'S WS178.00, WS220.00 AND WS264.00 REF. CRJ200 AMM 57-21-37-400-801SDR SWIA202159664Bearing · damagedROUTE LH AILERON TO BACK SHOP TO REMOVE AND REPLACE SWEDGED BEARINGS AND BUSHINGS AT HINGE POINTS (INBD, MID, OUTBD) ON LH AILERON PER AMM (C-CHECK RO 7/18/2021) INSTALLED 4EA. REPLACEMENT BUSHINGS IN LH AILERON REF CRJ 200 AMM 20-26-00-910-804, NO DEFESDR SWIA2021072159608Angle · damagedCOMPLY WITH REO 601R-53-41-1116 REPAIR & REINFORCEMENT FOR FS 559.00 LWR CAP ANGLES BL 9.00 & 18.00 LHS & RHS (C-CHECK RO 7/18/2021) COMPLIED WITH REO 601R-53-41-1116 REV-C DATED 2017-03-09 REPAIR & REINFORCEMENT FOR FS 559.00 LWR CAP ANGLES BL 9.00 & 1SDR SWIA2019112946799Vane · chafed* RIGHT INBD FLAP VANE MIDDLE LEADING EDGE CHAFFED (C-CHECK) RO: 11/27/2019 BLENDED OUT CHAFE DAMAGE ON THE R/H INBD FLAP VANE MIDDLE L/E VANE CAP. THE VANE CAP IS OUT OF LIMITS IAW REO. REMOVED AND INSTALLED NEW RH INBD FLAP, MIDDLE FLAP VANE CAP IAW SRM.SDR SWIA2019112946798Vane · chafed* RIGHT INBD FLAP VANE INBD LEADING EDGE CHAFFED (C-CHECK) RO: 11/27/2019 BLENDED OUT CHAFE DAMAGE ON THE R/H INBD FLAP VANE INBD L/E VANE CAP. THE VANE CAP IS OUT OF LIMITS IAW REO. REMOVED AND INSTALLED NEW RH INBD FLAP, INBD FLAP VANE CAP. IAW SRM.SDR SWIA2019112946797Vane · chafed* RIGHT INBD FLAP VANE OUTBD LEADING EDGE CHAFFED (C-CHECK) RO: 11/27/2019 BLENDED OUT CHAFE DAMAGE ON THE R/H I/B FLAP VANE O/B L/E VANE CAP. THE VANE CAP IS OUT OF LIMITS IAW REO. REMOVED AND INSTALLED NEW R/H I/B FLAP, O/B FLAP VANE CAP IAW SRM.SDR SWIA2019040545692Warning Message · false activationGEAR DISAGREE WARNING MSG WHEN SELECTING GEAR DOWN, SECONDS LATER GEAR DISAGREE MSG EXTINGUISHED, THE LH MAIN SHOWED DOWN AND LOCKED (GREEN). (FLT#4247) FO: 04/01.2019 WORK IN PROGRESSSDR SWIA2019022245563Pump · malfunctionedGEAR DISAGREE ON EXTENSION OF THE LANDING GEAR. NOSE WHEEL CAME DOWN VERY SLOWLY. (FLT#3854) REMOVED AND REPLACED #3B HYDRAULIC MOTOR ELECTRIC DRIVEN PUMP IAW AMM, OPS AND LEAK CHECK GOOD. PERFORMED FUNCTIONAL TEST OF THE EXTENSION/RETRACTION SYSTEM TEST WITSDR SWIA2018073044909Uplock · failedON APPROACH, SELECTED GEAR DOWN. MAINS EXTENDED NORMALLY, NOSE GEAR SHOWED YELLOW SLASHES. GEAR DISAGREE ANNUNCIATED. RAN QRH, ALL GEAR EXTENDED NORMALLY. (FLT 4556) CLOSED REMOVED AND REPLACED THE NLG UP LOCK PIN IAW AMM AND COMPLIED WITH ALIGNMENT OF THE NLGSDR ASOA201703157005Unknown · smokeCLIMBING THROUGH 6000-7000 FT, RECEIVED A SMOKE TOILET AMBER CAUTION MESSAGE. COMPLIED WITH QHR. PERFORMED AN OPS CHECK OF THE LAVATORY SMOKE DETECTOR IAW AMM 26-16-01. OPS CHECKED GOOD, MESSAGE NO LONGER EXISTS, ACFT RETURNED TO SERVICE. ON ANOTHER FLT,SDR ASOA201612101308Bulb · inoperativeRIGHT WING EMERGENCY EXIT AFT LIGHT OUT. REMOVED AND REPLACED THE BULB IAW AMM 33-51-27. OPS TESTED GOOD.SDR ASOA20161101147Bulkhead · crackedBS 202.75 BULKHEAD CRACKED. REPAIRED THE BULKHEAD IAW REO 601R=53-11-2976.SDR ASOA2015111014088Access Panel · corrodedPITTING CORROSION ON ACCESS OPENING, ACCESS PANEL 610AB, AREA IS MARKED. RECEIVED AND COMPLIED WITH ECTC EO600-57-81 C/W IAW REO 601R-57-21-030, REV L.SDR ASOA2015110314087Bulkhead · crackedAFT PRESSURE BULKHEAD IS CRACKED ABOVE CARGO DOOR AFT TRACK. COMPLIED WITH ECTC REO 601R-53-61-1541 AND GREO 601R-53-61-1541 AND MET ALL THE REQUIREMENTS OF REO 601R-53-61-1541, REV F, DATED 11/2/14.SDR ASOA2015110114116Floor Support · corrodedCORROSION FOUND AROUND SCREW HOLES UNDER FLOORBOARD 251ALF.SDR ASOA2015110114086Seat Track · corrodedRT SIDE SEAT TRACK CORRODED, FS449.85-499. REMOVED PASSENGER RT SIDE SEAT TRACK IAW AMM 53-01-11-000-802. FABRICATED SEAT RAIL IAW REO 601R-53-00-055. INSTALLED RT SIDE TRACK FS 449.84 - FS 499 IAW AMM 53-01-11-04, TASK 53-01-11-400-802. RECEIVED AND COMPLSDR ASOA2015110114085Floor Support · corrodedCORROSION ON LT PRESSURE FLOOR SILL SEVERAL PLACES, MARKED. REMOVED CORROSION FROM 5EA AREAS ON LT PRESSURE FLOOR IAW SRM 51-21-06 AND 53-41-45. BLEND AREA FOUND TO BE WITHIN THE ALLOWABLE DAMAGE LIMITS OF REO 601-53-41-666, REV C DATED 2012-11-06. COMPLIED SDR ASOA2015110114084Seat Track · corrodedSEAT TRACK CORRODED SEVERAL PLACES, RBL9 FS364-399. FOUND TO BE OUT OF LIMITS IA SR 53-00-49, 53-21-49. REMOVED SEAT TRACK IAW 53-01-11-000-802 AMM. FABRICATED NEW SEAT TRACK BR L9, FS 364-399 IAW REO 601R-53-00-485. INSTALLED NEW FABRICATED SEAT TRACK RBLSDR ASOA2015103114083Floor Support · corrodedR/T FLOOR SILL CORRODED OF FS 559.48 - FS 559.64. REMOVED CORROSION FROM RT FLOOR SILL AT FS 599+48-559+64 AND WAS FOUND THAT NO DAMAGE LIMITS ARE PROVIDED, FOUND TO BE OUT OF LIMITS IAW SRM 53-51-43. BLEND AREA FOUND TO BE WITHIN THE ALLOWABLE DAMAGE LIMITSSDR ASOA2015103114082Seat Track · corrodedSEAT TRACK CORRODED AT RBL 9, FS559 + 32 - 559 + 96. REMOVED SEAT TRACK IAW SRM 53-01-11-000-802. FABRICATED NEW SEAT TRACK IAW REO 601R-53-00-485. INSTALLED NEW FABRICATED SEAT TRACK IAW AMM 53-01-11-400-802.SDR ASOA2015103014075Crossbeam · corrodedCROSSBEAM CORRODED AT SERVICE DOOR, FS 349. CROSSBEAM AT SERVICE DOOR FS 349 OUT OF LIMITS IAW SRM 53-00-00-01. HEAT TREATED 1 REPAIR ANGLE WITH LIP AND -2 ANGLE FILLER IAW SRM 51-24-06 AND REO 601R-253-21-2672. HEAT TREATED -3 CLIP IAW SRM 51-24-06 AND REOSDR ASOA2015103014074Floor Support · corrodedFLOOR SILL CORRODED AFT OF SERVICE DOOR AT FS 349. FLOOR SILL AFT OF SERVICE DOOR AT FS 349 CORRODED OUT OF LIMITS IAW SRM 53-00-00-01. RECEIVED REO 601R-53-21-2670, REV DATED 2015-11-04, FORMED AND HEAT TREATED 1 REPAIR ANGLE AND 4 REPAIR ANGLE AS NEEDED RESDR ASOA2015103014073Floor Support · corrodedSERVICE DOOR THRESHOLD FLOOR SUPPORT CORRODED. BLENDED CORROSION IAW SRM 51-21-06-00, THRESHOLD FLOOR SUPPORT ANGLE FOUND TO BE OUT OF LIITS IAW SRM 53-00-00-01. REMOVED S/D THRESHOLD SUPPORT ANGLE IAW SRM TASK 31-42-06-00, 51-42-13-00, 51-42-21-00. LOCATED FSDR ASOA2015103014072Striker · corrodedSERVICE DOOR LOWER SEAL STRIKER CORRODED. EVALUATED AND FOUND SEVERE PITTING CORROSION OUT OF LIMITS IAW SRM 53-00-00. REMOVED DAMAGED SEAL STRIKER FITING BY REMOVING 26 ACH SCREWS. LOCATED FASTNER HOLES IN NEW SEAL STRIKER FITTING IAW RM 51-40-11. STARTEDSDR ASOA2015103014071Angle · corrodedSERVICE DOOR FWD ANGLE CORRODED AT FS 319.70. SERVICE DOOR FWD ANGLE FITTING CORRODED OUT OF LIMIT IAW SRM 53-00-00-01. R & R SERVICE DOOR FWD ANGLE AT FS 319.70, REF SRM 51-42-21 AND DWG 601R38335, REV E.SDR ASOA2015103014070Floor Support · corrodedRT FLOOR SILL CORRODED FWD OF FS 319.70. RT FLOOR SILL FWD OF FS 319.70 CORRODED OUT OF LIMITS IAW SRM 53-00-00-01. REMOVED ANGLE & SUPPORT PLATE ON RT FLOOR SILL FWD OF FS 319.70 IAW SRM 51-42-06. INSTALLED NEW ANGLE & NEW SUPPORT PLATE ON RT FLOOR SILL FW
Back to N878AS