N910AW
Service difficulty reports · 157
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N910AW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N910AW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AWXA9500293Intercostal · corrodedPHX - DURING C-6 INSPECTION, FOUND INTERCOSTAL AT FWD LAV THRESHOLD CORRODED, BS 310 TO 325. REMOVED, FABRICATED AND INSTALLED NEW INTERCOSTAL PER SRM 51-40-02. (Z)SDR AWXA9500292Angle · crackedPHX - DURING C-6 INSPECTION, FOUND MID CABIN FLOOR STABILIZER BEAM ANGLE FITTING CRACKED BETWEEN STA 780 AND 800. REMOVED, FABRICATED AND INSTALLED NEW ANGLE PER SRM 51-40-02. (Z)SDR AWXA9500249Connector · loosePHX - DURING ROUTINE MAINTENANCE CHECK, FOUND RT AISLE OVERHEAD EMERGENCY EXIT LIGHTS INOPERATIVE AT R2 AND R3 DOORS. RESEATED CONNECTORS AT M732, M734, AND M735. OPS CHECK GOOD. (X)SDR AWXA9500246Battery Assembly · inoperativePHX - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR PATH EMERGENCY EXIT LIGHTS INOPERATIVE, ROWS 20 THROUGH 25 AND FROM THE L3 DOOR THROUGH ROW 32. REMOVED AND REPLACED BATTERY ASSEMBLY AT M734, OPS CHECK GOOD. (X)SDR AWXA9500240Eel Wire · failedPHX - DURING ROUTINE MAINTENANCE CHECK, SEVERAL AREAS OF EMERGENCY EXIT LIGHTS FAILED TEST. FLOOR MOUNTED LIGHTS BETWEEN ROWS 18 AND 24, AND BOTH FLOOR AND OVERHEAD LIGHTS BETWEEN ROWS 27 AND 32. REPAIRED WIRES, OPS CHECK GOOD. (W)SDR AWXA9500105Eel Connector · loosePHX - DURING ROUTINE MAINTENANCE CHECK, FOUND EMERGENCY EXIT LIGHTS INOPERATIVE ROWS 15 THROUGH 18. RECONNECTED EMERGENCY LIGHTS AT ROW 16, OPS CHECK GOOD. (X)SDR AWXA9500074Eel Wire · brokenPHX - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR PATH EMERGENCY EXIT LIGHTS INOPERATIVE, ROWS 5 THROUGH 7 AND ROW 33 TO AFT. RECONNECTED WIRING AND RESECURED LIGHTS AS REQUIRED, OPS CHECK GOOD. (W)