N913WN
Service difficulty reports · 248
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N913WN' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N913WN' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2021072695942Wire · damagedR/H OVERWING EMERGENCY EXIT LIGHT (FWD LOWER ASSY.) INOP ; / [01] REPAIRED JIFFY SPLICE ON LIGHT ASSY. AS PER SWPM 20-30-12 AND PERFORMED GOOD FUNCTIONAL AS PER AMM 33-51-01-960-801 STEP 2.(2)<BR>TERM KIT:<BR>ID: T800-004<BR>S/N: E-3166; [02] VERIFIED REPAIREDSDR SWAA2021072693100Splice Strap · corrodedCORROSION BS727D LBL19- RBL1 9SPLICE STRAP HAS SEVERAL AREAS OF CORROSION AROUND FASTENER HOLES / [01] REMOVED AND REPLACED ACB SPLICE STRAP AT BS 727D LBL 19 TO RBL 19 DUE TO NO ALLOWABLE LIMIT IN THE SRM FOR THIS PART ; IAW SRM 51-10-02-0G-0 ; STEP 9 (C) ANDSDR SWAA2021072690716Skin · debondedLEFT HAND WING INBOARD SPOILER LOWER SURFACE SKIN IS DISBONDED AT THE INBOARD FORWARD CORNER. / [01] IDENTIFIED I/B SPOILER IAW SRM 57-70-01-0I-1.FIG 2; ITEM[1]. REMOVED FINISH IAW AMM 51-21-99-300-802.PARA 3.C.(3).(A)-(D). FOUND DAMAGE WAS UNBONDED FILLER. OKSDR SWAA2021072689889Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 410.5; RBL 25; WL 157, VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53--1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FCB FLOOR TO SIDEWALL SUPPORT BS410.5; RBL25; WL157; SDR SWAA2021072689890Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 407; RBL 24; WL 156.5 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53--1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FCB FLOOR TO SIDEWALL SUPPORT BS407; SDR SWAA2021072689893Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 454.5; LBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS454.5'';LSDR SWAA2021072689894Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 514.25; LBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS514.25''SDR SWAA2021072689895Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 500A+6.5; LBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS500A+6SDR SWAA2021072689896Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 500A+14.5; LBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS500A+SDR SWAA2021072689897Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 500B+10.5; LBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS500B+SDR SWAA2021072689898Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 500C+2; LBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS500C+2;LSDR SWAA2021072689899Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 500C+6.5; LBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS500C+6SDR SWAA2021072689900Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 500C+12; LBL 24; WL 156.5 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS500C+SDR SWAA2021072689904Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 470.5; LBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS470.5;LBLSDR SWAA2021072689905Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 474.5; LBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS474.5;LBLSDR SWAA2021072689906Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 505; LBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS505;LBL25;WSDR SWAA2021072689907Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 510.25; LBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS510.25''SDR SWAA2021072689908Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 517; LBL 24; WL 156.5 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS517'';LBLSDR SWAA2021072689909Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 518.5; LBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS518.5'';LSDR SWAA2021072689910Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 500A+10.5; LBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS500A+SDR SWAA2021072689911Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 500B+14.5; LBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS500B+SDR SWAA2021072689912Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 500B+17.75; LBL 24; WL 156.5 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS50SDR SWAA2021072689913Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 500C+14.5; LBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FLOOR TO SIDEWALL SUPPORT BS500C+14.5SDR SWAA2021072689901Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 500A+14.5; RBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 500SDR SWAA2021072689902Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 500C+13; RBL 24; WL 156.5 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 500SDR SWAA2021072689903Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 500C+14.5; RBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 500SDR SWAA2021072690673Support · corrodedCORROSION ON ACB R/H FLOOR-TO-SIDEWALL SUPPORT; BS 727D+6; RBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB R/H SIDEWALL SUPPORT AT BS 727D+6 RBL 21 WL 157; REWORKED AREA; L: 4' W: 0.800' ORIGINAL THICKNESS 0.040' REMOVED MAT. 0.008' REMAINING MAT. 0.SDR SWAA2021072690675Support · corrodedCORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 727D+7; LBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 727D+7; LBL 21; WL 157 WITH FOLLOWING MEASURES L= 0.7OO' W= 0.0670' D= 0.017' ALLOWABLE MATERIAL REMAINING ISSDR SWAA2021072690676Support · corrodedCORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 747+11; LBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 747+11; LBL 21; WL 157 WITH FOLLOWING MEASURES L= 0.900' W= 0.0750' D= 0.016' MATERIAL REMAINING IS 0.024' FOSDR SWAA2021072690677Support · corrodedCORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 767+7; LBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 767+7; LBL 21; WL 157 WITH FOLLOWING MEASURES L= 1.125' W= 0.0750' D= 0.013' MATERIAL REMAINING IS 0.027' FOUNSDR SWAA2021072690701Support · corrodedCORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 727D+15; LBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 727D+15; LBL 21; WL 157 WITH FOLLOWING MEASURES L= 1`' W= 0.600' D= 0.018 ALLOWABLE MATERIAL REMAINING IS 0.SDR SWAA2021072690702Support · corrodedCORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 727D+19; LBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 727D+19; LBL 21; WL 157 WITH FOLLOWING MEASURES L= 1' W= 0.0580' D= 0.018' ALLOWABLE MATERIAL REMAINING IS 0SDR SWAA2021072690703Support · corrodedCORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 747+11; LBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 747+11; LBL 21; WL 157 WITH FOLLOWING MEASURES L= 0.900' W= 0.0750' D= 0.016' MATERIAL REMAINING IS 0.024' FOSDR SWAA2021072690679Support · corrodedCORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 807+15; LBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 807+15; LBL 21; WL 157 WITH FOLLOWING MEASURES L= 1' W= 0.700' D= 0.004' MATERIAL REMAINING IS 0.036' FOUND TSDR SWAA2021072690705Support · corrodedCORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 767+15; LBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 767+15; LBL 21; WL 157 WITH FOLLOWING MEASURES L= 1.400' W= 1' D= 0.002' MATERIAL REMAINING IS 0.038' FOUND TSDR SWAA2021072690678Support · corrodedCORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 807+11; LBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 807+11; LBL 21; WL 157 WITH FOLLOWING MEASURES L= 0.980' W= 0.750' D= 0.007' MATERIAL REMAINING IS 0.033' FOUSDR SWAA2021072689886Shield · corrodedCORROSION ON FCB AFT SHIELD BS 514; RBL 24; WL 156.5 (MARKED). ; / [01] NOT HAVE ENTRIES FOR ALLOWABLE DAMAGE IN SRM. THE PART MUST BE REPAIRED BY REPLACEMENT PER SRM. 51-10-02 ITEM 9.C.; [02] VERIFIED PART WILL BE REPLACE PER SRM 51-10-02 STEP 9.; [03] LOCATESDR SWAA2021072689887Shield · corrodedCORROSION ON FCB FORWARD SHIELD BS 433; RBL 25; WL 157 (MARKED). ; / [01] NOT HAVE ENTRIES FOR ALLOWABLE DAMAGE IN SRM. THE PART MUST BE REPAIRED BY REPLACEMENT PER SRM. 51-10-02 ITEM 9.C.; [02] VERIFIED PART WILL BE REPLACE PER SRM 51-10-02 STEP 9; [03] LOCATSDR SWAA2021072690681Shield · corrodedCORROSION ON ACB FWD SHIELD; BS 767+4; RBL 23; WL 157 (MARKED) ; / [01] THIS ITEM DOES NOT HAVE ALLOWABLE DAMAGE THEREFORE HAVE TO BE REPAIRED BY REPLACEMENT PER SRM 51-10-02-0G-0 STEP 9; [02] THIS ITEM DOES NOT HAVE ALLOWABLE DAMAGE THEREFORE HAVE TO BE REPAISDR SWAA2021072690682Shield · corrodedCORROSION ON ACB FWD SHIELD; BS 767+8; RBL 22; WL 157 (MARKED) ; / [01] THIS ITEM DOES NOT HAVE ALLOWABLE DAMAGE THEREFORE HAVE TO BE REPAIRED BY REPLACEMENT PER SRM 51-10-02-0G-0 STEP 9; [02] LOCATED AND DRILLED NEW ACB FWD SHIELD BS 767-794 RBL 22 WL 157 IAWSDR SWAA2021072690699Support · corrodedCORROSION ON ACB R/H FLOOR-TO-SIDEWALL SUPPORT; BS 727C+18; RBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB R/H SIDEWALL SUPPORT AT BS 727C+18 RBL 21 WL 157; REWORKED AREA; L: 1.4' W: 0.700' ORIGINAL THICKNESS 0.040' REMOVED MAT. 0.008' REMAINING MATSDR SWAA2021072690698Support · corrodedCORROSION ON ACB R/H FLOOR-TO-SIDEWALL SUPPORT; BS 727C+14; RBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB R/H SIDEWALL SUPPORT AT BS 727C+14 RBL 21 WL 157; REWORKED AREA; L: 1.1' W: 0.600' ORIGINAL THICKNESS 0.040' REMOVED MAT. 0.009' REMAINING MATSDR SWAA2021072690697Support · corrodedCORROSION ON ACB R/H FLOOR-TO-SIDEWALL SUPPORT; BS 727C+10; RBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB R/H SIDEWALL SUPPORT AT BS 727C+10 RBL 21 WL 157; REWORKED AREA; L: 1.2' W: 0.650' ORIGINAL THICKNESS 0.040' REMOVED MAT. 0.010' REMAINING MATSDR SWAA2021072690696Support · corrodedCORROSION ON ACB R/H FLOOR-TO-SIDEWALL SUPPORT; BS 727C+6; RBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB R/H SIDEWALL SUPPORT AT BS 727C+6 RBL 21 WL 157; REWORKED AREA; L: 1.3' W: 0.750' ORIGINAL THICKNESS 0.040' REMOVED MAT. 0.008' REMAINING MAT. SDR SWAA2021072690695Support · corrodedCORROSION ON ACB R/H FLOOR-TO-SIDEWALL SUPPORT; BS 727C+2; RBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB R/H SIDEWALL SUPPORT AT BS 727C+2 RBL 21 WL 157; REWORKED AREA; L: 1.4' W: 0.650' ORIGINAL THICKNESS 0.040' REMOVED MAT. 0.010' REMAINING MAT. SDR SWAA2021072690694Support · corrodedCORROSION ON ACB R/H FLOOR-TO-SIDEWALL SUPPORT; BS 727B+13 - 727B+18; RBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB R/H SIDEWALL SUPPORT AT BS 727B+13 - 727B+18 RBL 21 WL 157; REWORKED AREA; L: 5'' W: 0.700' ORIGINAL THICKNESS 0.040' REMOVED MAT. 0SDR SWAA2021072690693Support · corrodedCORROSION ON ACB R/H FLOOR-TO-SIDEWALL SUPPORT; BS 727B+10; RBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB R/H SIDEWALL SUPPORT AT BS 727B+10 RBL 21 WL 157; REWORKED AREA; L: 1.1' W: 0.550' ORIGINAL THICKNESS 0.040' REMOVED MAT. 0.007' REMAINING MATSDR SWAA2021072690692Support · corrodedCORROSION ON ACB R/H FLOOR-TO-SIDEWALL SUPPORT; BS 727E+2; RBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON SIDEWALL SUPPORT AT BS 727B+2 RBL 21 WL 157; REWORKED AREA; L:1.1' W: 0.700' ORIGINAL THICKNESS 0.040' REMOVED MAT; 0.009' REMAINING MAT; 0.031 FOUSDR SWAA2021072690687Support · corrodedCORROSION ON ACB R/H FLOOR-TO-SIDEWALL SUPPORT; BS 747+6; RBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON SIDEWALL SUPPORT AT BS 747+6 RBL 21 WL 157; REWORKED AREA; L:1.2' W: 0.750' ORIGINAL THICKNESS 0.040' REMOVED MAT; 0.008' REMAINING MAT; 0.032 FOUNDSDR SWAA2021072690691Support · corrodedCORROSION ON ACB R/H FLOOR-TO-SIDEWALL SUPPORT; BS 747+18; RBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON SIDEWALL SUPPORT AT BS 747+18 RBL 21 WL 157; REWORKED AREA; L:1.5' W: 0.650' ORIGINAL THICKNESS 0.040' REMOVED MAT;0.008 ' REMAINING MAT; 0.032 FOU
Back to N913WN