N923AE
Service difficulty reports · 190
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N923AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N923AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA20210112001Lamp · inoperativeNR 1 AISLE EMERGENCY LIGHT INOPERABLE. C/A: R & R LAMP ON NR 1 AISLE EMERGENCY LIGHT, REF AMM 33-50-08. OPERATIONS CHECK GOOD.SDR SIMA20210110003Sensor · malfunctionedHIGH SPEED ABORT AT 90 KTS DUE TO OIL PRESS FLUX NR 1 OIL LEVEL DROPPED TO 2 QTS AT 90 KTS ABORTED THE T/O AND RTG. C/A: REMOVED AND REPLACED NR 1 ENGINE OIL LEVEL SENSOR, IAW ROLLS ROYCE MAINTENANCE MANUAL 79-35-20. PERFORMED OPERATIONAL CHECK, IAW 79-35-2SDR SIMA20201224002Power Supply · inoperativeOVERWING EMERGENCY LIGHTS INOPERABLE. C/A: R & R NR 4 EMERGENCY BATTERY POWER SUPPLY AND NR 4 EMERGENCY BATTERY, IAW ENOY W/C 33-700-19. OPERATIONS CHECK GOOD.SDR SIMA2020061005003Strut · low pressure"LG AIR/GND FAIL" EICAS MSG WHEN RAISING GEAR ON TAKEOFF. ON LANDING AIRCRAFT DIPPED RT WING LOW. INSPECTED AND FOUND RIGHT MLG STRUT TO HAVE LOW NITROGEN PRESSURE AND HIGH HYD FLUID, SERVICED IAW AMM 32-10-02 PERFORMED GEAR SWING IAW AMM 32-30-00 ALL CLEARANCSDR SIMA202005121002Warning System · false activationSUPPLEMENTAL DURING CLIMB WHILE PERFORMING THE ANTI-ICE CHECK BLD VLV FAIL #2 AND PACK 2 OVT CAME ON.-C/A-PERFORMED PNEU. A/I CHECK WITH CREW REF. AMM 30-00-00 OPS CHECK GOOD. CHECKED CMC AND FOUND 2 OCCURANCES OF PRECOOLR 1 SYS FAIL. DEFERRED PACK 1. MEL AUTHSDR SIMA202001221005Static Inverter · failedMECH. LANDED SAFELY NO EMERGENCY DECLARED. 115 VAC BUS OFF,GPWS INOP,WINDSHEAR INOP,TERR INOP ENROUTE FL320-C/A-RAR AC STATIC INVERTER IAW E 145 AMM 24-20-01.OPS CHECK GOOD IAW AMM 24-20-00.SDR SIMA201908221006Charger · failedL/H AND R/H OVER WING EMER. LIGHTS INOP. REMOVED AND REPLACED #4 EMERG. LIGHT CHARGER AND BATTERY ASSYS, OPC GOOD, IAW AMM 33-50-04.SDR SIMA20190401903Light · inoperativeAISLE EMERGENCY LIGHT AT 3A INOP.-C/A-REMOVED AND REPLACED AISLE EMERGENCY LIGHT AT 3A, OPC GOOD IAW AMM 33-50-08SDR SIMA2018100522005Door Sill · corrodedSSI 53-20-10; SERVICE DOOR CENTER SILL IS CORRODED-C/A-PERFORMED REPAIR,REWORKED AREAS ON SERVICE DOOR CENTER SILL. IAW SRM 53-21-02.SDR SIMA2018100510009Light · crackedLT NR 8 EMERGENCY LIGHT STRIP CRACKED-C/A-COMPLETE: REMOVED AND REPLACED LT NR 8 EMERGENCY LIGHT STRIP IAW AMM 33-50-12. SEE BOW304301 FOR OCKSDR SIMA2018100510012Floor Support · corrodedFWD DIGITAL IS CORRODED AT FRAME 15 AND CENTER FLOORBEAM-C/A-COMPLETE: REPAIRED FWD DIGITAL AT FRAME 15 AND CENTER FLOORBEAM IAW SRM 53-21-10, FIGURE 201, SHEET 5.SDR SIMA2018100510004Charger · defectiveNR 1 EPSU BATTERY AND CHARGER DEFECTIVE.-C/A-COMPLETE: R&R NR 1 EPSU BATTERY AND CHARGER IAW AMM 33-50-04. EASI 6488. OHM CHECK GOOD. OPERATIONAL CHECK GOOD.SDR SIMA2018100510011Charger · inoperativeNR 4 EPSU BATTERY AND CHARGER DEFECTIVE.-C/A-COMPLETE: REMOVED AND REPLACED NR 4 EPSU BATTERY AND CHARGER IAW AMM 33-50-04. EASI 6488. OHM CHECK GOOD. OPERATIONAL CHECK GOOD.SDR SIMA2018100510007Wire · brokenLT NR 4 EMERGENCY LIGHT STRIP WIRE IS BROKEN ON STRIP SIDE-C/A-COMPLETE:REMOVED AND REPLACED LT NR 4 CABIN FLOOR EMERGENCY LIGHT STRIP LIGHT STRIP IAW AMM 33-50-12. SEE BOW304301 FOR OPS CHECK.SDR SIMA2018100510008Housing · defectiveMAIN DOOR EMERGENCY LIGHT WORKS INTERMITTENTLY.-C/A-COMPLETE: R&R MAIN DOOR EMERGENCY LIGHT HOUSING ASSEMBLY IAW AMM 33-26-04. OPS CHECK GOOD.SDR SIMA2018100510010Fitting · crackedLT EMERGENCY LIGHT STRIP EXTRUSIONS NR 1, 3, 4, 6, 7 AND 8 ARE CRACKED-C/A-COMPLETE: REMOVED AND REPLACED LT EMERGENCY LIGHT STRIP EXTRUSIONS NR 1, 3, 4, 6, 7 AND 8 IAW AMM 33-50-12. SEE BOW304301 FOR OCKSDR SIMA2018100508005Power Supply · inoperativeFLOOR PROXIMITY LIGHTS 6-8 ARE INOPERATIVE-C/A-REMOVED AND REPLACED BATTERY POWER SUPPLY NR 4 IAW AMM-33-50-04. OPS CHECK GOODSDR SIMA201808154001Bulb · inoperativeRIGHT OVERWING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE BULB IAW AMM 33-50-10-04. OPS CHECKED GOOD.SDR SIMA201806075005Control Panel · malfunctionedFIRE DETECTOR TEST FAILED AT THE NR 2 FIRE HANDLE, LIGHT NOT COMING ON. REMOVED AND REPLACED FIRE DETECTION PANEL AND THE NR 2 FIRE HANDLE IAW AMM 26-00-01, AND 26-21-01. OPS CHECKED GOOD IAW AMM 26-10-00.SDR SIMA201804238006Lamp · inoperativeSERVICE DOOR EXTERNAL EMERGENCY LIGHT LAMP INOPERATIVE. REMOVED AND REPLACED THE LAMP IAW AMM 33-50-09-000-801-A, AND 33-50-09-400-801-A. OPS CHECKED GOOD.SDR SIMA20180312004Flashlight · intermittentFWD CABIN FLASHLIGHT SWITCH INTERMITTANT. R & R THE FLASHLIGHT IAW AMM 33-50-16-000-801-A, AND 33-50-16-400-801-A. OPS CHECKED GOOD.SDR SIMA20180302004Module · failedAFTER STARTING THE NR 1 ENGINE, THIN TRAIL OF SMOKE VISIBLE AND ODOR FROM BEHIND THE NR 2 LIGHTING PANEL. SMOKE STARTED WHEN FO CHART HOLDER LIGHT WENT OUT. FOUND THE CO PILOT`S LIGHTING CONTROL PANEL CHART HOLDER KNOB BURNED. REMOVED AND REPLACED CO PILOTSDR SIMA20180214002Light · inoperativeSEAT 12A OVERHEAD EMERGENCY LIGHT INOPERATIVE. R & R THE EMERGENCY LIGHT IAW AMM 33-50-07-000-801-A, AND 33-50-07-400-801-A, OPS CHECKED GOOD.SDR SIMA20170329002Battery · dischargedEMERG LIGHT INOP FLOOR. R&R NR 4 BATTERY AND BATTERY CHARGER AND INVERTER FOR EMERGENCY SEAT 15A,16A,17A AND 18A IAW AMM 33-50-04 AND AMM 33-50-11 OPS GOOD AT THIS TIME. CHARGER ASSY BATTERY P/N BA5-0933-901 S/N C02722. INVERTER P/N 7824-1SDR SIMA20170105002Light · inoperativeLT MAIN WING NAVIGATION LIGHT IS INOP. REMOVED AND REPLACED LT MAIN WING NAVIGATION LIGHT IAW 33-43-03. OPS CHECK GOOD. NO DEFECTS AT THIS TIME.SDR SIMA20161026005Hose · leakingBURNING ODOR IN COCKPIT WITH APU ON & PACK 2 ON. DUPLICATED ODOR WITH NR 2 PACK OPERATING. FOUND HOSE DISCONECTED ON NR 2 PACK FROM FRONT OF DUAL TEMP CONTROL VALVE TO HEAD EXCHANGER, REMOVED AND REPLACED HOSES AND HARDWERE IAW AMM 21-51-02 GROUND RAN LEAK SDR SIMA20160915001Fuse · blownMEL 33-29, EMERGENCY LIGHT ON PASSENGER DOOR INOPERATIVE. R & R FUSE FOR EMERGENCY LIGHT ON PASSENGER DOOR AT POWER SUPPLY. OPS CHECK GOOD MEL HAS BEEN RESTORED, REF CMM 25-60-03.SDR SIMA20160913003Fuse · inoperativeMAIN CABIN DOOR EXTERNAL EMERGENCY LIGHT INOPERATIVE. R & R FUSE FOR EMERGENCY LIGHT ON PASSENGER DOOR AT POWER SUPPLY. OPS CHECKED GOOD.SDR SIMA20160910001Brake · failedAFTER TAKEOFF, FLAPS WOULD NOT RETRACT FROM 9 DEGREES, FLAP FAIL MESSAGE ON EICAS, RAN QRH PROCEDURES, RETURNED TO DEPARTURE. R & R
FLAP TRANSMISSION BRAKE IAW AMM 27-51-01. OPS CHECK GOOD.SDR SIMA20160811001Flashlight · inoperativeCAPTAIN REPORTED FLASHLIGHT INOPERATIVE. R & R FLASHLIGHT STANDARD MAINTENANCE PRACTICE.SDR SIMA20160804002Flap System · failedFLAP FAIL DURING CLIMBOUT. PERFORMED ZERO DEGREE FLAP RIGGING IAW AMM 27-53-04 CKS GOOD, NO DEFECTS NOTED.SDR SIMA20160719002Door Sill · corrodedCARGO DOOR LOWER SILL CORRODED. PERFORMED REPAIR IAW SRM 53-31-15 ITEM 2 FIG 202.SDR SIMA20160718005Tee Fitting · corrodedCARGO DOOR LOWER SILL AFT TEE BRACKET CORRODED. REMOVED AND REPLACED THE TEE BRACKET IAW SRM 51-40-02, AND 51-20-03.SDR SIMA20160714004Yoke · crackedLEFT ENGINE PYLON FWD LOWER YOKE CRACKED. REMOVED AND REPLACED YOKE IAW EO EM-54MR-386SDR SIMA20160502003Hydraulic System · lowSYSTEM 1 HYD SYS LOW. SERVICED HYD 1 SYS IAW AMM 12-13-01, NO LEAKS NOTED. ACFT OK FOR SERVICE. PERFORMED OPERATIONS IAW AMM 29-10-00. NO DEFECTS NOTED. NO LEAKS NOTED. ACFT OK FOR SERVICE.SDR SIMA20151114004Cradle · crackedFOWARD CABIN FLASHLIGHT CRADLE IS CRACKED. R & R FWD FLIGHT ATTENDANT FLASHLIGHT HOLDER. OPERATIONS CHECKED GOOD IAW 33-50-06 AMM.SDR SIMA20150830002Switch · inoperativeBLEED 2 LOW TEMP IN ICING CONDITIONS, WHILE IN THE CLIMB WITH THRUST LEVERS IN THE THRUST SET POSITION, N2 WAS ABOVE 86%, N2 NR 2 BLEED TEMP POINTER WAS IN THE WHITE RANGE. TRANSFERRED TO NRWC 923-MIA-02210 ITEM 1. R & R NR 2 BLEED PUSHBUTTON IAW AMM 20-13-0SDR SIMA20150805002Flashlight · inoperativeCAPTAINS FLASHLIGHT BULB BURNED OUT. R & R CAPTAINS EMER FLASHLIGHT SYS IAW AMM 33-50-16. OPERATIONS CHECKED GOOD.SDR SIMA20150725001Light · not seatedRT WING AFT EMER EXIT LIGHT INOPERATIVE. RE-SEATED LAMP IN FIXTURE IAW AMM 33-50-10. OPERATIONS CHECKED GOOD.SDR SIMA20150518006Skin · delaminatedRIGHT INBD FLAP TOP SKIN DELAMINATED. ACCOMPLISHED TOP SKIN REPAIR ON RT INBD FLAP IAW ERS-EM-57MR-424.SDR SIMA20150423002Light · inoperativeSERVICE DOOR EMER LIGHT INOPERATIVE. R & R SERVICE DOOR EMER LAMP IAW AMM 33-50-10-000-801-A & 33-50-10-400-801-A. OPERATIONS CHECKED GOOD AT THIS TIME.SDR SIMA20141215001Starter Gen · failedTAXING FOR DEPARTURE WITH NR 2 ENGINE RUNNING & APU ON, A BURNING ODOR WAS OBSERVED ON THE FLIGHT DECK. AFTER DECIDING TO RETURN TO THE GATE, THE ODOR INTENSIFIED & WAS VERY STRONG IN THE CABIN & THE FLIGHT DECK. GROUND PERSONNEL SIGNALED TO SHUTDOWN & OBSERSDR SIMA20141202004Light · inoperativeFIRST OFFICER`S FLASHLIGHT INOPERATIVE. R & R FIRST OFFICER`S FLASHLIGHT LIGHT BULB AS REQUIRED. OPERATIONS CHECKED GOOD.SDR SIMA20141029005Light · inoperativeLEADING EDGE EMER LIGHT INOPERATIVE. R & R BULB IAW AMM 33-50-10. OPERATIONS CHECKED GOOD.SDR SIMA20141019010Flashlight · inoperativeCOCKPIT FLASHLIGHT INOPERATIVE. R & R IAW AMM 33-50-16.SDR SIMA20141017006Warning System · false activationHIGH SPEED ABORT ENG 1 REV DEPLOYED & REV DISAGREE MSG DISPLAYED. DEFERRED NR 1 THRUST REVERSER IAW MEL 78-2. M PROCEDURE COMPLIED WITH. NO INSPECTION REQUIRED FOR HIGH SPEED ABORT DUE TO NO MSGS RECEIVED IN AMM 5-50-16. TROUBLE SHOT IAW FIM 78-34-00-810-8SDR SIMA20140917006Inverter · inoperativeCOCKPIT STEP EMER LIGHT & FWD CEILING PANEL EMER LIGHT INOPERATIVE. R & R NR 1 INVERTER IAW AMM 33-50-11. PERFORMED OPERATIONS CHECK IAW AMM 33-50-00. OPERATIONS CHECKED GOOD.SDR SIMA20140626004Light · inoperativeMAIN ENTRY DOOR EMER LIGHT INOPERATIVE. R & R MAIN DOOR EXTERNAL EMER LIGHT IAW AMM 33-50-06. OPERATIONS CHECKED GOOD AT THIS TIME.SDR SIMA20140605009Battery · dischargedFOWARD THREE FLOOR EMERGENCY LIGHT STRIPS INOPERATIVE. R & R NR 2 EMER BATTERY POWER SUPPLY, BATTERY CHARGER & BATTERY HOLDER IAW AMM 33-50-04. OPERATIONS CHECK GOOD.SDR SIMA20140605010Skin · crackedRIGHT TOP FUSELAGE SKIN HAS 2 CRACKS AFT OF FRAME 75 & ABOVE STRINGER 2R. CRACK 1 APPROX 1/2 INCHES IN LENGTH AFT OF FRAME 75 & ABOVE STRINGER 2R. CRACK 2 IS APPROX 1/4 INCHES LONG ABOVE TOP MOST FRAME 75 FASTENER. PERFORMED PRIMARY REPAIR TO RT FUSELAGE TO
Back to N923AE