- Registered owner
- Bridge Funding Group Inc
- Location
- Hunt Valley, MD
- Owner type
- Corporation
- Serial number
- 920202
- Year built
- 2013
- Type
- Rotorcraft
- Engine
- Turbo-shaft
- Airworthiness
- Standard, transport
- Airworthiness date
- April 30, 2013
- Certificate issued
- January 4, 2016
- Expires
- January 31, 2029
- Mode S code
- AD0865
From the FAA registry file of October 24, 2026.
On this page
Airworthiness directives that may apply · 42
Matched by this aircraft’s airframe and engine models. Each AD’s applicability may narrow it by serial number, part number or equipment.
| 2005 | 1 |
|---|---|
| 2006 | 3 |
| 2007 | 1 |
| 2009 | 4 |
| 2010 | 3 |
| 2011 | 4 |
| 2012 | 4 |
| 2013 | 3 |
| 2014 | 3 |
| 2015 | 2 |
| 2016 | 3 |
| 2017 | 7 |
| 2018 | 1 |
| 2019 | 1 |
| 2020 | 1 |
| 2021 | 5 |
| 2022 | 4 |
| 2023 | 2 |
| 2024 | 2 |
See all 54 ADs
Information bulletins that may apply · 3
Advisory, not mandatory.
NTSB investigations
No NTSB investigations matched to N939PHMatched by N-number and event date, checked against the reported serial number, make and model. Investigations from before this aircraft carried the mark are under Earlier aircraft. Investigations on Sikorsky S-92A aircraft
FAA incident reports
No FAA accident or incident reports matched to N939PHMatched by N-number and event date, checked against the reported make and model. Reports from before this aircraft carried the mark are under Earlier aircraft. Reports on Sikorsky S-92A aircraft
Service difficulty reports · 4
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR 2023F00014Fan · inoperative#1 AC EVAPORATOR FAN FAILED WHICH SHOW UP ON THE MAINTENANCE PAGE AND THERE WAS A BURING SMELL IN THE COCKPIT. AIRCRAFT RETURNED TO HBP.SDR HEER20160912219Pump · failedHYDRAULIC NR 3 PUMP FAIL CAUTION AND RESERVOIR LOW DUE TO HYDRAULIC FLUID DUMPING OVERBOARD FROM APU DRAIN THROUGH FAILED APU STARTER SEAL. REPLACED APU HYDRAULIC STARTER FOR FAILED SEAL AND NR 3 HYDRAULIC PUMP DUE TO CAVITATING. ACFT RAN AND ALL SYSTEMS CHESDR HEER20160817059Fire Detector · failedFIRE LIGHT FLICKERED INTERMITTENTLY IN FLIGHT. NR 2 INBOARD FLAME DETECTOR FAILED TO TEST DURING TROUBLESHOOTING. REPLACED FLAME DETECTOR.SDR HEER20160813057Fire Detector · malfunctionedINTERMITTENT FIRE LIGHT AND WOULD NOT TEST. REPLACED FLAME DETECTOR NR 1 ENGINE OUTBOARD. FUNCTIONAL TESTED GOOD.
STCs that may be installed · 120
Approved for this aircraft’s airframe or engine model. The registry doesn’t record which STCs an aircraft has; its records do.