N995CF
Service difficulty reports · 505
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N995CF' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N995CF' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RRXA002321Skin · damagedDURING A MAINTENANCE VISIT FOUND SCREWS LOOSE AND PULLING BELOW SKIN ON THE RIGHT I/B SLOT DOOR LEADING EDGE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRMSDR RRXA002277Skin · damagedDURING A MAINTENANCE VISIT FOUND SCREWS PULLING THROUGH SKIN LT WING I/B SLOT LEADING EDGE VANE AT STA XS 220.000, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-SDR RRXA002241Skin · crackedDURING A MAINTENANCE VISIT FOUND A CRACK ON THE NR 1 STUB WING MOUNTING SHIM AT LWR FRONT SPAR CAP AT STA XW 454, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED SHIM IAW DC-8 SRSDR RRXA002216Skin · chafedDURING A MAINTENANCE VISIT FOUND CHAFING TO THE L1 DOOR SKIN AT EXTERIOR DOOR HANDLE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RETURNED TO SERVICE IAW EO NR 00-0047 WITH APPROVED 8110-3 DATED 4-17SDR RRXA002199Plate · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED LWR FRONT SPAR CAP ON THE NR 4 STUB WING I/B MOUNT SHIM, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. BLENDED EDGES SMOOTH AND RETURNED TO SERVICE IAW EO NR SDR RRXA002465Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM AT STA 540 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW DC-8 SRM 51-1-21 AND EOSDR RRXA002419Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND HOLES IN THE INTERCOSTAL AT FS 798 - 822 AND L5L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-4 AND 51-1-21.SDR RRXA002400Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM AT FS 680, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-20D AND EO NR 00-04SDR RRXA002383Threshold · crackedDURING A MAINTENANCE VISIT FOUND CRACKED AND DRILLED OFF SCREWS ON THE R1 DOOR SILL, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 51-3-0, 51-1-21 AND EO NR 0SDR RRXA002302Stiffener · crackedDURING A MAINTENANCE VISIT FOUND A 5 TO 6 INCH CRACK ON I/B SIDE VERTICAL STIFFENER RT TRAILING EDGE AT STA XRS 107, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED STIFFENER IAW DC-8 SRM 51-SDR RRXA002274Spoiler Panel · delaminatedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND A HOLE IN THE RT WING NR 1 GROUND SPOILER, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 57-2-3, PARA 22, FIG 4K ANSDR RRXA002270Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE LONGERON AT STA 1545 AND L8L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 51-1-21, 53-2-0 AND EOSDR RRXA002260Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE FLOORBEAM 1400 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES IAW EO NR 00-047 WITH APPROVED 8110-3 SDR RRXA002259Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE FLOORBEAM 1380 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLERS IAW DC-8 SRM 51-1-21, 51-1-4 SDR RRXA002237Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM 1300 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 51-1-21 AND EO NRSDR RRXA002232Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM 1100 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PLUGS/STRAPS IAW DC-8 SRM 51-1-20D ANDSDR RRXA002231Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM 1080 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PLUGS/STRAPS IAW EO NR 00-047 WITH APPSDR RRXA002229Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM 1260 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED STRAPS/FILLERS IAW DC-8 SRM 51-1-21, 5SDR RRXA002209Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE FLOORBEAM IN THE UPPER CARGO COMPT AT FS 650, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED STRAPS/FILLERS AND INSTALLED IAW SDR RRXA002480Skin · crackedDURING A MAINTENANCE VISIT FOUND A CRACK EMANATING FROM SCREW HOLE ON THE RIGHT I/B SLOT LEADING EDGE BOTTOM SIDE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-7SDR RRXA002466Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM AT STA 560 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW DC-8 SRM 51-1-21 AND EOSDR RRXA002462Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM AT STA 460 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW EO NR 00-047 WITH APPROSDR RRXA002461Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE FLOORBEAM AT FS 940, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW EO NR 00-047 WITH APPROVED 8110-3SDR RRXA002416Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE FLOORBEAM INTERCOSTALS AT FS 660 - 680, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITSDR RRXA002350Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM AT FS 980, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES IAW DC-8 SRM 51-1-21 AND EO NR 00-047 WITH ASDR RRXA002348Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM AT FS 940, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 51-1-21 AND EO NR 00-04SDR RRXA002347Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM AT FS 900, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES IAW DC-8 SRM 51-1-21 AND EO NR 00-047 WITH ASDR RRXA002346Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM AT FS 878, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES IAW DC-8 SRM 51-1-21 AND EO NR 00-047 WITH ASDR RRXA002345Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM AT FS 857, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES IAW DC-8 SRM 51-1-21 AND EO NR 00-047 WITH ASDR RRXA002265Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE FLOORBEAM AT STA 1440 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 51-1-21 ANSDR RRXA002257Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE FLOORBEAM 1340 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES IAW DC-8 SRM 51-1-21 AND EO NR 00-047 SDR RRXA002236Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM 1320 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES IAW EO NR 00-047 WITH APPROVED 8110-3 SDR RRXA002223Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE FLOORBEAM 1140 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES IAW EO NR 00-047 WITH APPROVED 8110-3 SDR RRXA002204Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE FLOORBEAM IN THE UPPER CARGO COMPT FS 1520, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES IN FLOORBEAM IAW EO NSDR RRXA002472Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM AT STA 360 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW DC-8 SRM 51-1-21 AND EOSDR RRXA002415Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM INTERCOSTAL AT FS 500 - 520, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITHSDR RRXA002406Threshold · crackedDURING A MAINTENANCE VISIT FOUND CRACKED AND DRILLED OFF SCREWS ON THE L1 DOOR SILL, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-21 AND EO NR 00-047 WITH APPROVEDSDR RRXA002380Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM INTERCOSTALS AT FS 480 - 500, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED REPAIR IAW EO NR 00-047 WITSDR RRXA002374Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM INTERCOSTALS AT FS 300 - 320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITSDR RRXA002340Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM AT FS 798, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 51-1-20D AND EO NR 00-0SDR RRXA002311Intercostal · tool damageDURING A MAINTENANCE VISIT FOUND DRILL MARKS BETWEEN STA 620 - 640 XCW 0 CENTER LINE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED CHANNEL IAW DC-8 SRM 51-1-24, 53-2-0 AND 51-SDR RRXA002290Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE INTERCOSTALS AT FS 1220 - 1240, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. HOLES WITHIN ACCEPTABLE LIMITATIONS IAW EO NR 00-047 WITH SDR RRXA002289Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE FLOORBEAM INTERCOSTALS AT FS 280 - 300, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. HOLES WITHIN ACCEPTABLE LIMITATIONS IAW EO NR 00-0SDR RRXA002288Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE INTERCOSTALS AT FS 1360 - 1380, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. HOLES WITHIN ALLOWABLE LIMITS IAW EO NR 00-047 WITH APPROVSDR RRXA002287Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE INTERCOSTALS AT FS 1400 - 1420, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM 51-1-8. HOLES WITHIN ALLOWABLE LIMITS IAW EO NR 00-047 WITH APPROVED 8110-3 DATED 3-26-00.SDR RRXA002286Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE INTERCOSTALS AT FS 980 - 1000, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. HOLES WITHIN ACCEPTABLE LIMITATIONS IAW EO NR 00-047 WITH ASDR RRXA002285Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE INTERCOSTALS AT FS 1100 - 1120, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. HOLES WITHIN ALLOWABLE LIMITS IAW EO NR 00-047 WITH APPROVSDR RRXA002284Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE INTERCOSTALS AT FS 1120 - 1140, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. HOLES WITHIN ALLOWABLE LIMITS IAW EO NR 00-047 WITH APPROVSDR RRXA002283Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE INTERCOSTALS AT FS 1280 - 1300, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. HOLES WITHIN ALLOWABLE LIMITS IAW EO NR 00-047 WITH APPROVSDR RRXA002282Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE INTERCOSTALS AT FS 1160-1180, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. HOLES WITHIN ALLOWABLE LIMITS IAW EO NR 00-047 WITH APPROVED