SDR RRXA002281Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES IN THE INTERCOSTALS AT FS 1800 - 1200, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. HOLES WITHIN ALLOWABLE LIMITS IAW EO NR 00-047 WITH APPROVED 8110-Apr 11, 2000 · N995CF · Doug DC862 · Fuselage Miscellaneous StructureSDR RRXA002224Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM 1160 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLERS IAW DC-8 SRM 51-1-21, 51-1-20Apr 11, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002479Frame · misdrilledDURING A MAINTENANCE VISIT FOUND A MISDRILLED HOLE IN THE FRAME RADIUS AT STA 920 AND L12R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-20D, 51-1-4 AApr 10, 2000 · N995CF · Doug DC862 · Fuselage Main, FrameSDR RRXA002381Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM INTERCOSTALS AT FS 420 - 440, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITApr 10, 2000 · N995CF · Doug DC862 · Fuselage Miscellaneous StructureSDR RRXA002379Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM INTERCOSTALS AT FS 440 - 460, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITApr 10, 2000 · N995CF · Doug DC862 · Fuselage Miscellaneous StructureSDR RRXA002378Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM INTERCOSTALS AT FS 380 - 400, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITApr 10, 2000 · N995CF · Doug DC862 · Fuselage Miscellaneous StructureSDR RRXA002377Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM INTERCOSTALS AT FS 360 - 380, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITApr 10, 2000 · N995CF · Doug DC862 · Fuselage Miscellaneous StructureSDR RRXA002376Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM INTERCOSTALS AT FS 340 - 360, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITApr 10, 2000 · N995CF · Doug DC862 · Fuselage Miscellaneous StructureSDR RRXA002375Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM INTERCOSTALS AT FS 320 - 340, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITApr 10, 2000 · N995CF · Doug DC862 · Fuselage Miscellaneous StructureSDR RRXA002328Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL DRILLED HOLES IN FLOORBEAM AT FS 740, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-21 AND EO NR 00-047 WITH APPROVED 8110-Apr 10, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002308Floor Support · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED FLOORBEAM SUPPORT AT STA 520 XCW 6 INCHES LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW ANGLE IAW DC-8 SRM 51-1-21, 53-2-0 ANApr 10, 2000 · N995CF · Doug DC862 · Fuselage Miscellaneous StructureSDR RRXA002292Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM INTERCOSTALS AT FS 460 - 480, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. HOLES WITHIN ALLOWABLE LIMITS IAW EO NR 00-047 WITApr 10, 2000 · N995CF · Doug DC862 · Fuselage Miscellaneous StructureSDR RRXA002291Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM INTERCOSTALS AT FS 400 - 420, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. HOLES WITHIN ACCEPTABLE LIMITATIONS IAW EO NR 00-0Apr 10, 2000 · N995CF · Doug DC862 · Fuselage Miscellaneous StructureSDR RRXA002266Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL DRILLED HOLES IN THE FLOORBEAM AT FS 760, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 51-1-21, 51-1-4, 51-1-20D Apr 10, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002344Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM AT FS 840, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED MISDRILLED HOLES PER EO NR 00-047 WITH APPROVED 8110-3 DATED Apr 8, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002235Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM 1280 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 51-1-4, 51-1-21 AApr 8, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002226Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM 1200 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLERS IAW DC-8 SRM 51-1-21, 51-1-4,Apr 8, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002463Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM AT STA 480 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW DC-8 SRM 51-1-4, 51-1-2Apr 7, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002359Angle · crackedDURING A MAINTENANCE VISIT FOUND A 6 INCH CRACK TO THE LT WING I/B SLOT UPPER O/B CUTOUT ANGLE AT STA XFS 250.000, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED PART IAW DC-8 SRM 51-1-21.Apr 7, 2000 · N995CF · Doug DC862 · Wing Miscellaneous StructureSDR RRXA002343Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM AT FS 830, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 51-1-4, 51-1-21 AND EO Apr 7, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002279Rib · crackedDURING A MAINTENANCE VISIT FOUND A 2.5 INCH CRACK TO THE UPPER RIB ON THE NR 2 STUB WING AT STA XFS 250.000, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 5Apr 7, 2000 · N995CF · Doug DC862 · Wing, Rib/BulkheadSDR RRXA002252Web · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE WEB ON BOX AREA ON L2 DOOR AREA STA 1460 LT BETWEEN L21L AND L22L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-Apr 7, 2000 · N995CF · Doug DC862 · Fuselage Miscellaneous StructureSDR RRXA002653Skin · dentedDURING A MAINTENANCE VISIT FOUND THE D PIT DOOR DENTED, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 51-1-4, 52-2-0, 52-2-3 AND 51-1-21.Apr 6, 2000 · N995CF · Doug DC862 · Cargo/Baggage DoorsSDR RRXA002411Web · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE MEMBRANE IN THE MAIN CABIN INTERIOR UPPER CUSP LINE AT STA 1080 AND L21R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IApr 5, 2000 · N995CF · Doug DC862 · Fuselage Miscellaneous StructureSDR RRXA002369Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND CRACKS AT SCREW HOLES ON NR 2 STUB WING UPPER SURFACE AT STA XS 233 TO 220, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED Apr 4, 2000 · N995CF · Doug DC862 · Wing, Plate/SkinSDR RRXA002297Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TOP OF LONGERON AND A WEAR SPOT ON THE LIGHT HOLE IN THE FWD LWR CARGO BILGE AT STA 544 AND L33R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. BLENDEDApr 4, 2000 · N995CF · Doug DC862 · Fuselage Main, Longeron/StringerSDR RRXA002278Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT WING NR 2 STUB WING UPPER RIB, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED ANGLE IAW EO NR 00-047 WITH APPROVED 8110-3 DATEApr 4, 2000 · N995CF · Doug DC862 · Wing, Rib/BulkheadSDR RRXA002247Attach Angle · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED ATTACH ANGLE FRAME AT STA 1480 RT AT L2R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW ANGLE IAW DC-8 SRM 51-1-21 AND 51-1-4.Apr 3, 2000 · N995CF · Doug DC862 · Fuselage Main, Attach FittingsSDR RRXA002326Intercostal · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED INTERCOSTAL AND MISSING FASTENERS AT FS 1300 TO 1320 AND L4R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-21Apr 1, 2000 · N995CF · Doug DC862 · Fuselage Miscellaneous StructureSDR RRXA002405Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE LONGITUDINAL FLOORBEAM BETWEEN STA 270 - 225 AND RBL 45.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAWMar 31, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002372Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE LONGITUDINAL FLOORBEAM BETWEEN STA 270 - 225 AND RBL 28.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAWMar 31, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002371Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE LONGITUDINAL FLOORBEAM AT STA 270 - 225 RT AND RBL 45.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DMar 31, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA02256Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE LONGITUDINAL FLOORBEAM AT RBL 28 1/2 10 BETWEEN STA 270 - 225 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED MISDRILLED HOLES IMar 31, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002313Web · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED INTERIOR WEB ON THE R-1 DOOR AT STA 395 RT AND L18R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 52-2-0, 51-1-Mar 31, 2000 · N995CF · Doug DC862 · Passenger/Crew DoorsSDR RRXA002329Attach Fitting · gougedDURING A MAINTENANCE VISIT FOUND A GOUGED FLOORBEAM ATTACH FITTING AT FS 798 AND XCW 23 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED REPAIR IAW DC-8 SRM 51-3-0 AND 51-1-20D.Mar 30, 2000 · N995CF · Doug DC862 · Fuselage Main, Attach FittingsSDR RRXA002230Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM 1060 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED L ANGLE IAW EO NR 00-047 WITH APPROVEDMar 30, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002319Panel · crackedDURING A MAINTENANCE VISIT FOUND MULTIPLE DRILLED HOLES AND CRACKS TO THE L2 CUSP PANEL AT STA 1480 TO 1520, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW PANEL IAW DC-8 SRMar 29, 2000 · N995CF · Doug DC862 · Fuselage Miscellaneous StructureSDR RRXA002267Attach Fitting · gougedDURING A MAINTENANCE VISIT FOUND A GOUGE TO THE RT TANK EXTERIOR TO FLOORBEAM ATTACH FITTING AT FS 760=XCW 46, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 5Mar 27, 2000 · N995CF · Doug DC862 · Fuselage Main, Attach FittingsSDR RRXA002387Attach Angle · brokenDURING A MAINTENANCE VISIT FOUND A BROKEN ATTACH ANGLE AT STA 1568 AND L24L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21, 51-1-4 AND 51-3-0.Mar 14, 2000 · N995CF · Doug DC862 · Fuselage Main, Attach FittingsSDR RRXA002386Attach Angle · brokenDURING A MAINTENANCE VISIT FOUND A BROKEN ATTACH ANGLE AT STA 1568 AND L24R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21, 51-1-4 AND 51-3-0.Mar 14, 2000 · N995CF · Doug DC862 · Fuselage Main, Attach FittingsSDR RRXA002337Attach Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FRAME ATTACH ANGLE TO FWD RT OVERWING EXIT DOOR AT FS 717 - 740 AND L19R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW FITTING Mar 13, 2000 · N995CF · Doug DC862 · Fuselage Main, Attach FittingsSDR RRXA002304Skin · tornDURING A MAINTENANCE VISIT FOUND FUSELAGE SKIN TORN AWAY BY GROUND PNEUMATIC CONNECTOR DOOR CUTOUT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 51-1-21 AMar 13, 2000 · N995CF · Doug DC862 · Fuselage Main, Plate/SkinSDR RRXA002481Floor Support · gougedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE AFT FLOORBEAM SUPPORT AROUND BOLT HEADS AND A DEEP GOUGE AT FS 960 XCW 0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DMar 10, 2000 · N995CF · Doug DC862 · Fuselage Miscellaneous StructureSDR RRXA002403Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE LONGITUDINAL FLOORBEAM AT STA 270 - 225 AND RBL 10, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SMar 10, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002385Panel · damagedDURING A MAINTENANCE VISIT FOUND DAMAGE TO THE C PIT DOOR FILLET PANEL, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21 AND 51-1-4.Mar 10, 2000 · N995CF · Doug DC862 · Cargo/Baggage DoorsSDR RRXA002373Attach Angle · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED ATTACH ANGLE IN THE MAIN CABIN INTERIOR AT STA 1586 AND L31L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-3-Mar 10, 2000 · N995CF · Doug DC862 · Fuselage Main, Attach FittingsSDR RRXA002384Attach Angle · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED DOOR SCUFF PLATE ATTACH ANGLE AT STA 1140 AND L34R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21 AND 51-Mar 9, 2000 · N995CF · Doug DC862 · Fuselage Miscellaneous StructureSDR RRXA002357Structure · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AT SCREW HOLES ON THE RT O/B HORIZONTAL STAB LEADING EDGE I/B AT STA XFS 185 TO 187, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTAMar 9, 2000 · N995CF · Doug DC862 · Horizontal Stabilizer StructureSDR RRXA002336Tie Clip · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED INTERCOSTAL FRAME TIE AT FS 760 AND L3R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED GUSSET IAW DC-8 SRM 51-1-21 AND 51-1-4.Mar 9, 2000 · N995CF · Doug DC862 · Fuselage Miscellaneous StructureSDR RRXA002334Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND HOLES IN THE INTERCOSTAL AT FS 900 - 920 AND L21R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES IAW DC-8 SRM 53-2-0 AND 51-1-21.Mar 9, 2000 · N995CF · Doug DC862 · Fuselage Miscellaneous Structure
Back to N995CF