N108PH, cancelled Aug 16, 2010
Service difficulty reports · 22
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N108PH' AND deregistration_id = 'N108PH-2010-08-16' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N108PH' AND deregistration_id = 'N108PH-2010-08-16' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HEEA088455Gearbox · corrodedTAIL ROTOR GEARBOX HAS CORROSION ON INSIDE DIAMETER OF OUTPUT SHAFT; BINDING. REPLACED OUTPUT SHAFT 206-040-439-001, S/N A-FS6642 DUE TO EXCESSIVE CORROSION; CONTROL TUBE 206-011-724-109 DUE TO EXCESSIVE CORROSION. REPAIRED.SDR HEEA083406Battery · weakMAIN BATTERY WEAK.SDR HEEA083054Gps · malfunctionedGPS INTERNAL BATTERY LOW. SLOW TO ACQUIRE STATIONS.SDR HEEA075534Crosstube · corrodedCORRODED BEYOND LIMITS IN SADDLE AREA. SCRAPPED AND REPLACED WITH SERVICEABLE PART.SDR HEEA075508Crosstube · corrodedCROSSTUBE CORRODED BEYOND LIMITS. SCRAPPED.SDR HEEA060955Dc Converter · failedNO POWER OUT WHEN USING A/C GENERATOR.SDR HEEA060883Torquemeter · fluctuatesTORQUEMETER FLUCTUATES AND NEEDLE STICKS AT 50 PERCENT.SDR HEEA060873Indicator · sticksNEEDLE STICKS THROUGHOUT SCALE ON DUAL TACHOMETER.SDR HEEA060799Float · leakingFLOAT BAG ASSEMBLY'S CHECK VALVE LEAKING.SDR HEEA060135Gps · failedGPS 150 WILL NOT HOLD MEMORY AND INTERNAL BATTERY IS DEAD.SDR HEEA0013805Indicator · fluctuatesDUAL TACH N2 NEEDLE FLUCTUATES.SDR HEEA0013786Power Supply · failedSTROBE POWER SUPPLY INOPERATIVE.SDR HEEA0013764Indicator · failedINDICATOR STAYS 1/2 BALL OFF.SDR HEEA0013754Tach Gen · failedTACH GENERATOR FLUCTUATES 4% TO 10%.SDR HEEA0012687Indicator · failedINDICATOR TURN NEEDLE IS INOPERATIVE.SDR HAIHEEA9507Gps 150 · defectiveGPS DISPLAY FADED.SDR HAIHEEA9504Gps 150 · failedGPS DOES NOT ACQUIRE ANY SATELLITES.SDR HEEA968531Antenna · defectiveGPS CANNOT FIND SATELLITE AND ANT ATTACH FITTING IS LOOSE.SDR HEEA968441Indicator · sticksINDICATOR NEEDLE STICKS ON FIRST START OF DAY.SDR HEEA967693Liner · mis mfgRECEIVING INSPECTION REVEALED: ALIGNMENT 1/2 HOLE OFF TO RIGHT ON COMB LINER PIN. LINER TRIED ON SEVERAL TURBINES AND UNABLE TO INSTALL FUEL NOZZLE WITH IGNITOR AND DUMMY PLUG IN PLACE. UNABLE TO INSTALL IGNITOR PLUG WITH FUEL NOZZLE AND DUMMY PLUG INSTALLEDSDR HEEA967665Crosstube · mis drilledTWO HOLES ON LEFT SIDE AFT ARE MISSED DRILLED. REPLACED WITH SERVICEABLE CROSSTUBE.SDR HEEA967277Indicator · defectiveINDICATES 3% HIGH OUT OF TOLERANCE AND SLUGGISH OPERATION.
Back to N108PH, cancelled Aug 16, 2010