N12064, cancelled Jun 5, 2002
Service difficulty reports · 31
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N12064' AND deregistration_id = 'N12064-2002-06-05' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N12064' AND deregistration_id = 'N12064-2002-06-05' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA0100926Warning System · malfunctionedA FORWARD CARGO FIRE WARNING WAS INDICATED AT 10,000 FEET ON APPROACH TO HNL. BOTH FIRE BOTTLES WERE DISCHARGED AND THE AIRCRAFT LANDED AT HNL WITHOUT INCIDENT. MAINTENANCE FOUND NO EVIDENCE OF FIRE. THE FIRE WARNING SYSTEM WAS TROUBLESHOT AND NO FAULTS WERE FSDR CALA0100806Fuse · blownINSPECTION FOUND L-4 AND R-4 DOOR LOWER EXIT LIGHT INOPERATIVE. THE FUSE IN EMERGENCY LIGHT BATTERY PACK U1-165 WAS REMOVED AND REPLACED IAW WDM 33-52-04 AND OPERATION CHECKED GOOD.SDR CALA0001635Air Box · crackedINSPECTION FOUND A 2 INCH CRACK IN LOWER CENTER PYLON AIR BOX WHERE THE PRECOOLER AIR DUCT ATTACHES (I/B SIDE). THE CRACKED AREA WAS CUT OUT AND A REPAIR WAS INSTALLED IAW SRM 54-20-00, FIGURE 19A.SDR CALA9901718Flashlight · inoperativeINSPECTION FOUND TWO EACH EMERGENCY PORTABLE FLASHLIGHTS INOPERATIVE. THE FLASHLIGHTS WERE REPLACED AND TESTED IAW MM 25-60-00.SDR CALA9901600Spar · crackedINSPECTION FOUND A 3 INCH CRACK IN LEFT HORIZONTAL STABILIZER PANEL SIDE UPPER CHORD. THE CHORD WAS REMOVED AND A REPAIR WAS INSTALLED IAW SRM 51-33-01.SDR CALA9901599Support · corrodedINSPECTION FOUND LAV SUPPORT CORRODED AT STA 1860-1889, BL 0. THE LAV SUPPORT WAS REMOVED AND A NEW SUPPORT WAS INSTALLED IAW SRM 51-31-01.SDR CALA9901598Channel · corrodedINSPECTION FOUND CENTER CARGO COMPARTMENT LEFT CHANNEL CORRODED UNDER OMNI ROLLERS. A NEW CHANNEL WAS INSTALLED IAW SRM 53-42-01.SDR CALA9901563Support · corrodedINSPECTION FOUND LAV SUPPORTS CORRODED AT STA 1860-1887, RBL 47 AND AT STA 1850-1890, LBL 47. THE SUPPORTS WERE REMOVED AND NEW SUPPORTS WERE INSTALLED IAW SRM 51-31-01.SDR CALA9901553Support · corrodedINSPECTION FOUND GALLEY FLOOR SUPPORT CORRODED BETWEEN STA 785 AND 789, RBL 47. THE FLOOR SUPPORT WAS REMOVED AND A NEW FLOOR SUPPORT WAS INSTALLED IAW SRM 53-70-00, FIGURE 13 AND 51-31-01.SDR CALA9901552Support · corrodedINSPECTION FOUND CABIN FLOORBEAM SUPPORT CORRODED BETWEEN STA 460 AND 515, LBL 33. THE FLOOR SUPPORT WAS REMOVED AND A NEW SUPPORT WAS INSTALLED IAW SRM 51-31-01.SDR CALA9901551Frame · corrodedINSPECTION FOUND CENTER CARGO COMPARTMENT LOWER FRAME CORRODED AT STA 1780 BETWEEN LONGERON 50L - 50R AND AT STA 1841, L49R - 50L. THE CORRODED AREAS WERE TRIMMED OUT AND REINFORCED WITH SHEAR CLIPS AND SPLICES IAW SRM 53-30-00, FIGURES 9 AND 10, AND SRM 51-3SDR CALA9901550Frame · corrodedINSPECTION FOUND CENTER CARGO COMPARTMENT LOWER FRAME CORRODED FROM STA 1660-1680, LONGERON 51L - 51R. THE CORRODED AREA WAS TRIMMED OUT AND REINFORCED WITH SHEAR CLIP AND SPLICE IAW SRM 53-30-00, FIGURE 10 AND SRM 51-31-01.SDR CALA9901543Support · crackedINSPECTION FOUND FLOOR SUPPORT CRACKED AT UPPER LOBE CABIN FLOOR STA 495-615, RBL 14. THE CRACKED AREA OF FLOOR SUPPORT WAS TRIMMED OUT. A NEW SECTION WAS INSTALLED IAW SRM 51-31-01 AND 51-21-01.SDR CALA9901542Support · corrodedINSPECTION FOUND FLOOR SUPPORT CORRODED AT UPPER LOBE CABIN FLOOR AT STA 395-457, RBL 28-33 AND STA 420-475, LBL 27. THE FLOOR SUPPORTS WERE REMOVED AND NEW SUPPORTS WERE INSTALLED IAW SRM 51-31-01.SDR CALA9900196Frame · crackedTHE NR 3 ENGINE A AND B FIRELOOP LIGHTS ILLUMINATED AND THE FIRE HANDLE FLASHED AFTER TAKEOFF FROM HNL. CHECKLIST PROCEDURES WERE COMPLIED WITH AND THE AIRCRAFT WAS RETURNED TO HNL WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE FOUND THE NR 3 ENGINE 13TH STAGSDR CALA9802049Skin · dentedINSPECTION FOUND THE LT OUTBOARD TRAILING EDGE FLAP INBOARD SKIN DENTED AT LOWER FLAP 29 INCHES FROM INBOARD END. THE DENTED AREA WAS TRIMMED OUT AND REINFORCED WITH DOUBLER IAW SRM 57-10-00, FIGURE 7, 51-21-01, AND 51-31-01.SDR CALA9802048Channel · crackedINSPECTION FOUND A 1 INCH CRACK IN HORIZONTAL CHANNEL OF OUTBOARD AFT FAIRING AT RT MLG WHEEL WELL. THE CRACKED TEE WAS REMOVED AND A NEW TEE WAS INSTALLED IAW SRM 53-53-01, FIGURE 4, 51-21-01, AND 51-31-01.SDR CALA9802047Light · inopINSPECTION FOUND THE EMERGENCY EXIT LIGHT AT SEATS 21B, 34K, AND 36B INOPERATIVE. THE EMERGENCY LIGHT IN SEATS 21B, 34K, AND 36B WERE REPLACED IAW MM 33-50-00.SDR CALA9802046Seat Track · corrodedINSPECTION FOUND SEAT TRACK CORRODED AT STA 1289, RBL 107. THE CORRODED SECTION OF SEAT TRACK WAS REMOVED AND A NEW SECTION WAS INSTALLED IAW SRM 53-70-00, FIGURE 18 AND 51-21-01.SDR CALA9802045Skin · dentedINSPECTION FOUND RT FUSELAGE SKIN DENTED AT STA 1942, STRINGERS 51-52. THE DENTED AREA WAS TRIMMED OUT AND REINFORCED WITH INNER AND OUTER DOUBLERS IAW SRM 53-20-00, FIGURE 6, 51-21-01, AND 51-31-01.SDR CALA9802042Skin · dentedINSPECTION FOUND FUSELAGE SKIN DENTED AT STA 515 TO 535, S28L. THE DENTED AREA WAS TRIMMED OUT AND REINFORCED WITH DOUBLER AND FINGER DOUBLER IAW SRM 53-20-00, FIGURE 6, 51-21-01, AND 51-31-01.SDR CALA9802041Doubler · crackedINSPECTION FOUND A 2.7 INCH CRACK AND DELAMINATION ON RT WING MLG SUPPORT DOUBLER. THE CRACKED AND DELAMINATED AREAS WERE TRIMMED OUT AND REINFORCED WITH DOUBLER AND FILLER IAW SRM 53-45-01, FIGURE 1, 51-21-01, AND ECRA 5730-01595.SDR CALA9802009Door · crackedINSPECTION FOUND A 1.75 INCH CRACK AT AFT LOWER CORNER OF RT MLG WHEEL WELL DOOR. THE AREA WAS REINFORCED WITH A DOUBLER IAW SRM 51-21-01 AND 51-35-02.SDR CALA9802008Battery Pack · dischargedTHE EMERGENCY LIGHT SYSTEM IN A ZONE FAILED AFTER SIX MINUTES. THE BATTERY PACKS WERE REPLACED AND OPERATION CHECKED GOOD IAW MM 33-50-00.SDR CALA9802007Floorbeam · crackedINSPECTION FOUND A 1 INCH CRACK IN FLOORBEAM AT STA 1275, RBL 104. REPAIRED IAW ECRA 5316-01000.SDR CALA9701595Thrust Reverser · crackedINSPECTION FOUND A CRACK ON INNER SKIN ADJACENT TO OPEN CLOSE ACTUATOR OF #2 ENGINE C DUCT RH. THE #2 ENGINE R/H THRUST REVERSER WAS REPLACED IAW MM 78-32-11.SDR CALA9701594Thrust Reverser · delaminatedINSPECTION FOUND #2 ENGINE L/H THRUST REVERSER UPPER AFT SIDEWALL DELAMINATED. THE #2 ENGINE L/H THRUST REVERSER WAS REPLACED IAW MM 78-32-11.SDR CALA9701593Exhaust Nozzle · crackedINSPECTION FOUND A 5 CRACK IN #2 ENGINE EXHAUST NOZZLE. THE #2 ENGINE EXHAUST NOZZLE WAS REPLACED IAW MM 78-11-08.SDR CALA9701525Fasteners · shearedINSPECTION FOUND SIX FASTENER HEADS SHEARED AT LOWER AFT FACE OF NR 4 BANJO FITTING, NR 2 PYLON. THE FASTENERS WERE REMOVED AND REPLACED WITH NEW FASTENERS IAW SRM 51-42-00.SDR CALA9701524Bulkhead · holeINSPECTION FOUND A .5625 DIAMETER HOLE IN AFT PRESSURE BULKHEAD BETWEEN FLOOR SUPPORT BEAM AND LONGERON 41L AT STA 2007. REPAIRED IAW SRM 53-40-00.SDR CALA9701512Angle · corrodedINSPECTION FOUND FLOORBEAM HORIZONTAL ATTACHMENT ANGLE CORRODED AT THIRD FLOORBEAM RT FROM O/B SIDE, STA 2007, AFT CARGO LAV AREA. THE AREA WAS REPAIRED IAW SRM 53-40-00 FIGURE 16 PAGE 93.
Back to N12064, cancelled Jun 5, 2002