Service difficulty reports · 6
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR AALA20030300Connector · looseDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR LIGHTS ROW 11-13 INOPERATIVE. SECURED EMERGENCY EXIT LIGHT BATTERY CONNECTOR AT SEAT ROW 11. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20020593Light · defective(LIGHT) DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT TRACK LIGHT AFT OF ROW 11, INOPERATIVE. CYCLES FROM DIM TO OFF. REPLACED 4 FOOT SECTION OF EMERGENCY EXIT FLOOR PATH LIGHTING IN FORWARD ZONE. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20000858Light · inoperativeATL - ON OVERNIGHT CHECK, FORWARD LAVATORY EMERGENCY LIGHT INOPERATIVE. REPLACED FORWARD LAVATORY EMERGENCY LIGHT. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR AALA20000008Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHT AFT OF AIRCRAFT INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT STRIP AFT OF AIRCRAFT. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR AALA981353Apu · failedYYZ - FLT 1084 - AFTER TAKEOFF YYZ EN ROUTE TO LGA ON CLIMB-OUT, SMOKE WAS OBSERVED IN COCKPIT WITH BURNING SMELL. SMOKE APPEARED AFTER APU WAS SHUT DOWN IN-FLIGHT. AIRCRAFT RETURNED AND LANDED YYZ WITHOUT INCIDENT. REPLACED APU PER MM. ACCOMPLISHED OPERATSDR AALA951056B-Nut · looseBNA - FLT NR 2092 - EN ROUTE DFW/BNA, DURING CRUISE HYDRAULIC SYSTEM 1 LOW QUANTITY INDICATED ON MFDU. HYDRAULIC SYSTEM 1 QUANTITY INDICATED BETWEEN 35 AND 36 PERCENT. DEACTIVATED SYSTEM 1 PUMP 1 AND 2, AND AIRCRAFT PROCEEDED TO BNA. ACCOMPLISHED ALTERNATE
Other aircraft with N1406A · 3
The FAA can assign a mark to another aircraft once a registration is cancelled. No aircraft carries N1406A now.